Search NASA⌕ Search

SEARCH · Search NASA

Results for “absorbed power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Assessment of the Free-piston Stirling Convertor as a Long Life Power Convertor for Space

There is currently a renewed interest in the use of free-piston Stirling power convertors for space power applications. More specifically, the Stirling convertor is being developed to be part of the Stirling Radioisotope Power System to supply electric power to spacecraft for NASA deep space science missions. The current development effort involves the Department of Energy, Germantown, MD, the NASA Glenn Research Center, Cleveland, OH, and the Stirling Technology Company, Kennewick, WA. The Stirling convertor will absorb heat supplied from the decay of plutonium dioxide contained in the General Purpose Heat Source modules and convert it into electricity to power the spacecraft. For many years the "potentials" of the free-piston Stirling convertor have been publicized by it's developers. Among these "potentials" were long life and high reliability. This paper will present an overview of the critical areas that enable long life of the free-piston Stirling power convertor, and present some of the techniques that have been used when long life has been achieved.

Schreiber, Jeffrey G.↗

Mass transfer intensification through increased surface wetting and liquid turbulence using 3D printing structured packing for CO2 capture

The absorber column is one of the most expensive pieces of equipment to construct in the solvent-based post-combustion carbon capture unit. In order to decrease the absorber size and reduce capital costs, novel polymer packings were proposed by enhancing surface wettability and local turbulence within liquid solvent. The novel packings intensify the mass transfer in CO2 absorption and show better separation efficiency than traditional structured packings. In this work, the economic influence of applying the more efficient packing with a shorter absorber column is studied in a techno-economic analysis for a carbon capture unit at a coal-fired power plant. The baseline case includes CO2 capture unit in a supercritical pulverized coal power plant to generate 650 MWe (net) of electricity, where the additional CO2 capture unit leads to 63.4% increase of LCOE. While implementing UK PCC with traditional and novel packings, there will be 47.2% and 46.4% LCOE increase separately, both of which are lower than the baseline value. Applying more efficient packing and smaller absorber could further lessen the LCOE increase. The UK PCC with traditional packings reduces CO2 capture cost by 23.4% and the application of the advanced packings allows to the reduction increases to 24.4%.

60 APPLIED LIFE SCIENCES↗

Fabrication of neutron absorbing metal hydride entrained ceramic matrix shield composites

With significant improvement in High Temperature Superconductors (HTS), several projects are adopting HTS technology for fusion power systems. Compact HTS tokamaks offer potential advantages including lower plant costs, enhanced plasma control, and ultimately lower cost of electricity. However, as compact reactors have a reduced radial build to accommodate shielding, HTS degradation due to radiation damage or heating is a significant and potentially design limiting issue. Shielding must mitigate threats to the superconducting coils: neutron cascade damage, heat deposition and potentially organic insulator damage due x-rays. Unfortunately, there are currently no hi-performance shielding materials to enable the potential performance enhancement offered by HTS. In this work, we present a manufacturing method to fabricate a new class of composite shields that are high performance, high operating temperature, and simultaneously neutron absorbing and neutron moderating. The composite design consists of an entrained metal-hydride phase within a radiation stable MgO ceramic host matrix. We discuss the fabrication, characterization, and thermophysical performance data for a series of down-selected composite materials inspired by future fusion core designs and their operational performance metrics. To our knowledge these materials represent the first ceramic composite shield materials containing significant metal hydrides.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mg II absorption in the spectra of 103 QSOs - Implications for the evolution of gas in high-redshift galaxies

Spectra of 103 low- and intermediate-redshift QSOs with a resolution of 4-6 A were obtained in order to investigate the statistics of the M II 2796, 2803 absorption systems over the redshift range of 0.2-2.2. New emission-line redshifts, based mostly on Mg II 2800 and semiforbidden 1909, were determined for the QSOs. The mean number density of Mg II absorbers per unit redshift range decreased from 0.97 +/-0.10 for a rest equivalent width threshold of 0.3 A to 0.27 +/-0.05 for a threshold of 1.0 A. The results are in agreement with comparable previous work. The observed equivalent width distribution could be fitted with either exponential or power-law analytic distributions, with parameters in line with those found in earlier studies. Statistical tests show that the Mg II absorbers are uniformly distributed in both comoving coordinates and velocity relative to the QSO.

Steidel, Charles C.↗

Spectral emittance measurements of micro/nanostructures in energy conversion: a review

Micro/nanostructures play a key role in tuning the radiative properties of materials and have been applied to the high-temperature energy conversion systems for improved performance. Among the various radiative properties, spectral emittance is of integral importance for the design and analysis of materials that function as radiative absorbers or emitters. This article presents an overview of the spectral emittance measurement techniques using both the direct and indirect methods. Several micro/nanostructures are also introduced, and a special emphasis is placed on the emissometers developed for characterizing engineered micro/nanostructures in high-temperature applications (e.g., solar energy conversion and thermophotovoltaic devices). Both experimental facilities and measured results for different materials are summarized. Future prospects in developing instrumentation and micro/nanostructured surfaces for practical applications are also outlined. This study provides a comprehensive source of information for the application of micro/nanostructures in high-temperature energy conversion engineering.

14 SOLAR ENERGY↗

PVwindow (Photovoltaic Window Simulator) [SWR-22-01]

PVwindow simulates photovoltaic window properties by allowing the user build stacks of thin film materials that compose the window layers. The only needed inputs are the complex refractive indices and thicknesses of the materials. The software will simulate the optical transmission, front reflection, and back reflection of the stack using the transfer matrix method. Properties specific to PV window optics such as visible transmittance and color are also calculated. The optics code extracts the number of absorbed photons in the PV absorber layer and solves the single diode equation to yield theoretical photovoltaic metrics such as power conversion efficiency, fill factor, open circuit voltage, and short circuit current of the PV window when illuminated at an arbitrary angle or from either side of the stack. The software tool ultimately allows researchers to design photovoltaic windows and simulate their properties. The software also exports files that can be read into LBL Window software or into the EnergyPlus and Open Studio building energy modeling software to determine larger scale energy impacts of PV window integration.

Wheeler, Lance↗

Load cell for thermionic converter tests

Stable, low duty cycle transistorized emitter follower load cell controls and absorbs large currents at low voltages. The use of energy storage in capacitors reduces auxiliary power source requirements. Low duty cycle pulse mode of operation reduces the average power handling requirement of all components.

Breitwieser, R.↗

Active mode-coupling phenomena in pulsed and continuous lasers

An optical modulator inside a laser cavity, if driven at the cavity c/2L frequency or a harmonic, will produce a variety of mode-coupled short-pulse and FM-laser phenomena. This paper reviews the kinds of CW and transient mode-coupling phenomena that can occur in CW lasers and in selected lower-power pulsed lasers using either an active optical modulator or in some cases passive saturable absorbers.

Siegman, A. E.↗

X-ray and UV observations of two radio-bright quasars

The two quasars PKS 10004 + 13 (4C 13.41, V about equal to 15.2, z = 0.140) and PKS 0637 - 75 (V = 15.75, z = 0.651) were observed in December 1980 with IUE. Both were detected in the short-wavelength region. The present X-ray upper limit for PKS 1004 + 13 gives the lowest L-x/L-opt measured in quasars. PKS 0637 - 75 was observed nearly simultaneously with the Einstein Observatory and a spectrum obtained with the IPC. The UV and soft X-ray data have been combined and are discussed together with the optical and infrared data for both objects. The extreme L-x/L-opt ratio of PKS 1004 + 13 may be the result of an exceptionally large blackbody UV excess superposed on a power-law continuum of slope about 1.1. An alternative would be a large hydrogen column absorbing low-energy X-rays although this is unlikely. PKS 0637 - 75 shows no evidence for any UV excess. The two quasars seem to be at opposite ends of the degree of dominance of the UV spectrum by a blackbody component. The lack of a Lyman limit discontinuity in PKS 0637 - 75 at the redshift of an intervening galaxy implies that the optically detected, intervening hydrogen is ionized.

Elvis, M.↗

Advances toward high spectral resolution quantum X-ray calorimetry

Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

Moseley, S. H.↗

Two dimensional analysis of a high temperature gaseous radiation receiver

The characteristics of the Flowing Gas Radiation Receiver (FGRR), a device that absorbs solar radiation volumetrically in a gas to produce high temperatures for space propulsion and power applications, are analyzed using a two-dimensional axisymmetric numerical model of the flow and radiation fields within a diffusely reflecting channel. The results show that an FGRR system is capable of generating temperatures in excess of 3000 K with collection efficiencies of approximately 75 percent for a channel with a reflectivity of 0.9. For a collinear radiation source, outflow temperatures of 3193 and 3092 K were achieved for axial and radial flow inputs, respectively, with receiver efficiencies of 0.82 and 0.76.

Mcfall, K. A.↗

Multiple Hollow Cathode Wear Testing

A hollow cathode-based plasma contactor has been baselined for use on the Space Station to reduce station charging. The plasma contactor provides a low impedance connection to space plasma via a plasma produced by an arc discharge. The hollow cathode of the plasma contactor is a refractory metal tube, through which xenon gas flows, which has a disk-shaped plate with a centered orifice at the downstream end of the tube. Within the cathode, arc attachment occurs primarily on a Type S low work function insert that is next to the orifice plate. This low work function insert is used to reduce cathode operating temperatures and energy requirements and, therefore, achieve increased efficiency and longevity. The operating characteristics and lifetime capabilities of this hollow cathode, however, are greatly reduced by oxygen bearing contaminants in the xenon gas. Furthermore, an optimized activation process, where the cathode is heated prior to ignition by an external heater to drive contaminants such as oxygen and moisture from the insert absorbed during exposure to ambient air, is necessary both for cathode longevity and a simplified power processor. In order to achieve the two year (approximately 17,500 hours) continuous operating lifetime requirement for the plasma contactor, a test program was initiated at NASA Lewis Research Center to demonstrate the extended lifetime capabilities of the hollow cathode. To date, xenon hollow cathodes have demonstrated extended lifetimes with one test having operated in excess of 8000 hours in an ongoing test utilizing contamination control protocols developed by Sarver-Verhey. The objectives of this study were to verify the transportability of the contamination control protocols developed by Sarver-Verhey and to evaluate cathode contamination control procedures, activation processes, and cathode-to-cathode dispersions in operating characteristics with time. These were accomplished by conducting a 2000 hour wear test of four hollow cathodes with different xenon gas purities and activation processes. The following will be presented: a description of the facility and test hardware, testing procedures and operating conditions, a discussion of test results, and conclusions.

Soulas, George C.↗

Gas Sensor

High Technology Sensors, Inc.'s Model SS-250 carbon dioxide detector uses a patented semiconductor optical source that efficiently creates infrared radiation, which is focused through an airway on a detector. Carbon dioxide passing through the airway absorbs the radiation causing the detector to generate a signal. The small size and low power requirements of the SS-250 make it attractive for incorporation in a variety of medical instruments.

Source record↗

Heat Entrapment Effects Within Liquid Acquisition Devices

We introduce a model problem to address heat entrapment effects or the local accumulation of thermal energy within liquid acquisition devices. We show that the parametric space consists of six parameters, namely the Rayleigh and Prandtl numbers, the aspect ratio, and heat flux ratios for the bottom, side, and top boundaries of the enclosure. For the range of Ra considered 1 to 10(sup 9), beyond Ra on the order of 10(sup 5), convective instability is the dominant mode of convection in comparison to natural convection. The flow field transitions to asymmetric modes at Ra on the order of 10(sup 7). Direct numerical simulation of a large geometric length scale prototype for Ra on the order of 10(sup 9) shows that the flow field evolves from small wavelength instability which gives rise to nonlinear growth of thermals, propagation of the instability occurs via growth of secondary and tertiary modes, and a travelling wave mode occurs prior to asymmetry. The effect of a large aspect ratio is to increase the number of modes in the vertical direction. Due to the slow diffusion of heat in the prototype, asymptotic states are not readily attained, we show that dynamical similarity can be used for a model which allows the attainment of asymptotic states and that transition to a chaotic state occurs for Ra on the order of 10(sup 9) via a broadband power spectrum. These dynamical events show that for the baseline condition in which heat is absorbed from background laboratory environment, higher heat flux is absorbed at the top and bottom boundaries of the enclosure than a nominal value of 34.9 ergs per square centimeter -second.

Duval, W. M. B.↗

Nickel-Tin Electrode Materials for Nonaqueous Li-Ion Cells

Experimental materials made from mixtures of nickel and tin powders have shown promise for use as the negative electrodes of rechargeable lithium-ion electrochemical power cells. During charging (or discharging) of a lithium-ion cell, lithium ions are absorbed into (or desorbed from, respectively) the negative electrode, typically through an intercalation or alloying process. The negative electrodes (for this purpose, designated as anodes) in state-of-the-art Li-ion cells are made of graphite, in which intercalation occurs. Alternatively, the anodes can be made from metals, in which alloying can occur. For reasons having to do with the electrochemical potential of intercalated lithium, metallic anode materials (especially materials containing tin) are regarded as safer than graphite ones; in addition, such metallic anode materials have been investigated in the hope of obtaining reversible charge/discharge capacities greater than those of graphite anodes. However, until now, each of the tin-containing metallic anode formulations tested has been found to be inadequate in some respect.

Ehrlich, Grant M.↗

NASA Tech Briefs, January 2003

Topics covered include: Optoelectronic Tool Adds Scale Marks to Photographic Images; Compact Interconnection Networks Based on Quantum Dots; Laterally Coupled Quantum-Dot Distributed-Feedback Lasers; Bit-Serial Adder Based on Quantum Dots; Stabilized Fiber-Optic Distribution of Reference Frequency; Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System; Ladar System Identifies Obstacles Partly Hidden by Grass; Survivable Failure Data Recorders for Spacecraft; Fiber-Optic Ammonia Sensors; Silicon Membrane Mirrors with Electrostatic Shape Actuators; Nanoscale Hot-Wire Probes for Boundary-Layer Flows; Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing; Efficient Coupling of Lasers to Telescopes with Obscuration; Aligning Three Off-Axis Mirrors with Help of a DOE; Calibrating Laser Gas Measurements by Use of Natural CO2; Laser Ranging Simulation Program; Micro-Ball-Lens Optical Switch Driven by SMA Actuator; Evaluation of Charge Storage and Decay in Spacecraft Insulators; Alkaline Capacitors Based on Nitride Nanoparticles; Low-EC-Content Electrolytes for Low-Temperature Li-Ion Cells; Software for a GPS-Reflection Remote-Sensing System; Software for Building Models of 3D Objects via the Internet; "Virtual Cockpit Window" for a Windowless Aerospacecraft; CLARAty Functional-Layer Software; Java Library for Input and Output of Image Data and Metadata; Software for Estimating Costs of Testing Rocket Engines; Energy-Absorbing, Lightweight Wheels; Viscoelastic Vibration Dampers for Turbomachine Blades; Soft Landing of Spacecraft on Energy-Absorbing Self-Deployable Cushions; Pneumatically Actuated Miniature Peristaltic Vacuum Pumps; Miniature Gas-Turbine Power Generator; Pressure-Sensor Assembly Technique; Wafer-Level Membrane-Transfer Process for Fabricating MEMS; A Reactive-Ion Etch for Patterning Piezoelectric Thin Film; Wavelet-Based Real-Time Diagnosis of Complex Systems; Quantum Search in Hilbert Space; Analytic Method for Computing Instrument Pointing Jitter; and Semiselective Optoelectronic Sensors for Monitoring Microbes.

Source record↗

Tracking Critical Thermal Metrics throughout the Life Cycle of a Large Observatory Thermal Model

Observatory thermal models for large, complex missions, such as the Wide Field InfraRed Survey Telescope (WFIRST) mission, produce an immense amount of data to be processed. Configuration management of the model throughout the project life cycle has mainly focused on which versions of the subsystem models form the current observatory level configuration. However, the results produced by the model are not nearly as well tracked and traceable. Given the various states of design maturity for each of the components in the WFIRST design, an updated component model is nearly ready to be integrated at the next higher level of assembly about every month or two. With each subsystem model delivery, the observatory model needs to remove the old component, integrate the new one, execute the model, and inspect the results. Usually, this inspection focuses primarily on the newly integrated component. Recently, a Metric Tracking Spreadsheet was developed to help provide a “big picture” view of the entire observatory highlighting key parameters critical to mission performance. This spreadsheet helps track impacts on subsystems by updates of other subsystems that were not intuitively obvious. Metrics tracked include: absorbed environmental loading (to determine effectiveness of sunshield), temperatures of critical avionics, electrical dissipations, heater power predictions, stability of critical optics, parasitic heat leaks in cryogenic region, high level heat flows between elements, and model run time. Producing this data for the same operational configuration with each model update has helped produce a trail of data to evaluate the impact of model updates. While the metrics selected are specific for WFIRST, other large, complex observatories could be well served to establish their own metrics early in the project life cycle to track to quickly assess the impact of any subsystem on other subsystems or the overall system itself.

Thermal Desktop↗

Lignin as a bioactive polymer and heavy metal absorber- an overview

As a pulping and bio-refinery by-product with phenolic chemical structure, lignin indicated high potential as natural antioxidant activity, UV blocker, antibacterial and toxic material absorbent properties. Presence of phenolic hydroxyl groups in lignin structure plays the main role of its antioxidant activity. However, lignin antioxidant power can change depending on its other structural features and functional groups like ortho-methoxy groups, –OCH 3 groups, the α-CH 2 groups, the aliphatic carbonyl groups, and the size of π-conjugated systems. Lignin in mixture with synthetic polymers, improved their thermal stability. Lignin has high UV light absorbing potential in broad-spectrum (UVA, UVB). Adding 1–5% of lignin into hand cream indicated excellent range of sun protection factor (SPF) with more than 95% UV light absorption. Lignin also indicated strong UV light protection when applied in different transparent film and protect paint, oil, and varnish from UV degradation. Further, lignosulfonate and other modified lignin including chemically modification, nano-particles and lignin hydrogel indicated high potential as heavy metal absorber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗