Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Soft x-ray array system with variable filters for the DIII-D tokamak

Recent upgrades to the soft x-ray (SXR) array system on the DIII-D tokamak are described. The system consists of two 32-channel arrays at one toroidal location and three toroidally distributed 12-channel arrays. The 32-channel arrays have been completely rebuilt to allow the switching of SXR filters without breaking vacuum. The 12-channel arrays have had upgrades performed to detectors, view slits, and data acquisition. Absolute extreme ultraviolet (AXUV) photodiodes are used as detectors in all arrays, allowing detection of photons ranging in energy from 2 eV to 10 keV. In the fixed-filter arrays, 127 {mu}m Be filters are used. In the variable-filter arrays, filter wheels are used to switch between five different possible pinhole/filter combinations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ablation dynamics in coiled wire-array Z-pinches

Experiments to study the ablation dynamics of coiled wire arrays were performed on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and on the COBRA generator at Cornell University's Laboratory of Plasma Studies (1 MA, 100 ns). The MAGPIE generator was used to drive coiled wires in an inverse array configuration to study the distribution of ablated plasma. Using interferometry to study the plasma distribution during the ablation phase, absolute quantitative measurements of electron line density demonstrated very high density contrasts between coiled ablation streams and inter-stream regions many millimetres from the wire. The measured density contrasts for a coiled array were many times greater than that observed for a conventional array with straight wires, indicating that a much greater axial modulation of the ablated plasma may be responsible for the unique implosion dynamics of coiled arrays. Experiments on the COBRA generator were used to study the complex redirection of plasma around a coiled wire that gives rise to the ablation structure exhibited by coiled arrays. Observations of this complex 3D plasma structure were used to validate the current model of coiled array ablation dynamics [Hall et al., Phys. Rev. Lett. 100, 065003 (2008)], demonstrating irrefutably that plasma flow from the wires behaves as predicted. Coiled wires were observed to ablate and implode in the same manner on both machines, indicating that current rise time should not be an issue for the scaling of coiled arrays to larger machines with fast current rise times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanoindentation study of the mechanical behavior of TiO{sub 2} nanotube arrays

Titanium dioxide (TiO{sub 2}) nanotube arrays are attracting increasing attention for use in solar cells, lithium-ion batteries, and biomedical implants. To take full advantage of their unique physical properties, such arrays need to maintain adequate mechanical integrity in applications. However, the mechanical performance of TiO{sub 2} nanotube arrays is not well understood. In this work, we investigate the deformation and failure of TiO{sub 2} nanotube arrays using the nanoindentation technique. We found that the load–displacement response of the arrays strongly depends on the indentation depth and indenter shape. Substrate-independent elastic modulus and hardness can be obtained when the indentation depth is less than 2.5% of the array height. The deformation mechanisms of TiO{sub 2} nanotube arrays by Berkovich and conical indenters are closely associated with the densification of TiO{sub 2} nanotubes under compression. A theoretical model for deformation of the arrays under a large-radius conical indenter is also proposed.

36 MATERIALS SCIENCE↗

Conformal array design on arbitrary polygon surface with transformation optics

A transformation-optics based method to design a conformal antenna array on an arbitrary polygon surface is proposed and demonstrated in this paper. This conformal antenna array can be adjusted to behave equivalently as a uniformly spaced linear array by applying an appropriate transformation medium. An typical example of general arbitrary polygon conformal arrays, not limited to circular array, is presented, verifying the proposed approach. In summary, the novel arbitrary polygon surface conformal array can be utilized in array synthesis and beam-forming, maintaining all benefits of linear array.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DETECTION OF FAST TRANSIENTS WITH RADIO INTERFEROMETRIC ARRAYS

Next-generation radio arrays, including the Square Kilometre Array (SKA) and its pathfinders, will open up new avenues for exciting transient science at radio wavelengths. Their innovative designs, comprising a large number of small elements, pose several challenges in digital processing and optimal observing strategies. The Giant Metre-wave Radio Telescope (GMRT) presents an excellent test-bed for developing and validating suitable observing modes and strategies for transient experiments with future arrays. Here we describe the first phase of the ongoing development of a transient detection system for GMRT that is planned to eventually function in a commensal mode with other observing programs. It capitalizes on the GMRT's interferometric and sub-array capabilities, and the versatility of a new software backend. We outline considerations in the plan and design of transient exploration programs with interferometric arrays, and describe a pilot survey that was undertaken to aid in the development of algorithms and associated analysis software. This survey was conducted at 325 and 610 MHz, and covered 360 deg{sup 2} of the sky with short dwell times. It provides large volumes of real data that can be used to test the efficacies of various algorithms and observing strategies applicable for transient detection. We present examples that illustrate the methodologies of detecting short-duration transients, including the use of sub-arrays for higher resilience to spurious events of terrestrial origin, localization of candidate events via imaging, and the use of a phased array for improved signal detection and confirmation. In addition to demonstrating applications of interferometric arrays for fast transient exploration, our efforts mark important steps in the roadmap toward SKA-era science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization with dense array data of seismic sources in the shallow part of the San Jacinto fault zone

SUMMARY We analyse dominant sources identified in a catalogue of more than 156 000 localizations performed using a 26-d data set recorded by a dense array set on the San Jacinto fault near Anza, in California. Events were localized using an array processing technique called Match Field Processing. As for all array processing techniques, the quality of the event position decrease when the events are outside of the array. We thus separate localizations in and outside the array using simple geometrical conditions. We compare the time distribution of the localization to additional data such as meteorological data, day of human activity as well as existing catalogues to determine the nature of the dominant events located using our method. We find that most of the events located outside of the array could be attributed to a surface structure excited by wind. On the other hand, part of the localizations under the array occur during regional earthquakes and could correspond to diffraction on the fault's heterogeneities. The rest of the localizations inside the array could be generated by the fault itself.

Geochemistry & Geophysics↗

Real-time scintillation array dosimetry for radiotherapy: The advantages of photomultiplier detectors

Purpose: In this paper, a photomultiplier tube (PMT) array dosimetry system has been developed and tested for the real-time readout of multiple scintillation signals from fiber optic dosimeters. It provides array dosimetry with the advantages in sensitivity provided by a PMT, but without the need for a separate PMT for each detector element. Methods: The PMT array system consisted of a multianode PMT, a multichannel data acquisition system, housing and optic fiber connections suitable for clinical use. The reproducibility, channel uniformity, channel crosstalk, acquisition speed, and sensitivity of the PMT array were quantified using a constant light source. Its performance was compared to other readout systems used in scintillation dosimetry. An in vivo HDR brachytherapy treatment was used as an example of a clinical application of the dosimetry system to the measurement of dose at multiple sites in the rectum. The PMT array system was also tested in the pulsed beam of a linear accelerator to test its response speed and its application with two separate methods of Cerenkov background removal. Results: The PMT array dosimetry system was highly reproducible with a measurement uncertainty of 0.13% for a 10 s acquisition period. Optical crosstalk between neighboring channels was accounted for by omitting every second channel. A mathematical procedure was used to account for the crosstalk in next-neighbor channels. The speed and sensitivity of the PMT array system were found be superior to CCD cameras, allowing for measurement of more rapid changes in dose rate. This was further demonstrated by measuring the dose delivered by individual photon pulses of a linear accelerator beam. Conclusions: The PMT array system has advantages over CCD camera-based systems for the readout of scintillation light. It provided a more sensitive, more accurate, and faster response to meet the demands of future developments in treatment delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-639: A Study On the Response of 2D Array Detector for VMAT Delivery for a Period of Two Years

Purpose: To evaluate the 2D array for radiation response for a period of 2 years. Methods: 45 VMAT plans already treated and quality assured before 2 years, 1.5 years and 1 year were selected for the study. Quality assurances of the plans were done using 2D array combined with Octavius phantom. Verification plans were recalculated without changing any parameters in Eclipse 10.0 TPS using the AAA algorithm. Response of 2D array to the plans treated before 2 years, 1.5 years and 1 year where evaluated. The results were analyzed using the Gamma analysis method with the standard gamma passing criteria of 3mm distance to agreement (DTA) and 3% dose difference (DD). Results: All the plans evaluated passed the gamma analysis with a percentage greater than 95, except for three cases. Higher gamma passing criteria where observed for all the analyzed plans, when analysis done before 2 years, 1.5 years and 1 year. The standard deviation of ± 1.38, ± 1.40,± 0.97 where observed between the plans when verification plans did before 2 years, 1.5 years and 1 year respectively. Same set of plans shows a standard deviation of ± 0.70, ± 1.36, and ± 1.18, when analysis done recently. A significance difference in response of the array when analysis done recently for the verification plans treated and quality assured before 2 years.This indicates a slightly reduced response of 2D array towards radiation response as the array gets older. Conclusion: It is found that 2D array shows a reduced response against radiation detection over a period of years. An onsite calibration of the instrument is recommended before the measurements. A dose correction factor can be applied if necessary to the results if the radiation response and efficiency of the array is very poor.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance

Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and off axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.

60 APPLIED LIFE SCIENCES↗

SU-F-T-321: The Effect of an Electromagnetic Array Used for Patient Localization and Tumor Tracking On OSLD in Vivo Dosimetry

Purpose: The purpose of this study was to observe the effect of an electromagnetic array used for patient localization and tumor tracking on optically-stimulated luminescent in-vivo dosimetry. Methods: A linear accelerator equipped with four photon energies was used to irradiate optically stimulated luminescent dosimeters (OSLDs) at the respective dmax depths and in the buildup region, with and without the presence of an electromagnetic array used for tumor tracking and patient localization. The OSLDs were placed on solid water slabs under 5 mm bolus and on each face of an octagonal phantom, and irradiated using both static beam and arc geometry, with and without the electromagnetic array under our setup. The electromagnetic array was placed 6 cm above the phantom to coincide with similar distances used during patient treatment. Ionization chamber measurements in a water phantom were also taken initially for comparison with the simple geometry OSLD measurements and published data. Results: Under simple geometry, a negligible change was observed at dmax for all energies when the electromagnetic array was placed over the setup. When measuring at five millimeter depth, increases of 1.3/3.1/16/18% were observed for energies 4X/6X/10X/15X respectively when the electromagnetic array was in place. Measurements using the octagonal phantom yielded scattered results for the lateral and posterior oblique fields, and showed increases in dose to the OSLDs placed on the anterior and lateral anterior faces of the phantom. Conclusion: Placing the electromagnetic array very close to the patient’s surface acts as a beam spoiler in the buildup region (at 5 mm depth), which in turn causes an increase in the measured dose reading of the OSLD. This increase in dose is more pronounced when the OSLD is placed directly underneath the electromagnetic array than off to one side or the other.

43 PARTICLE ACCELERATORS↗

Study of Implosion of Combined Nested Arrays

New experimental data on the implosion of plasma of nested kapron−tungsten arrays are obtained at the Angara-5-1 facility. The mode of plasma implosion is implemented in which a shock wave region forms in the space between the inner and outer arrays where a transition from the super-Alfvénic (V{sub r} > V{sub A}) to sub-Alfvénic (V{sub r} < V{sub A}) plasma flow takes place. Specific features of the formation and decay of the shock region are studied using laser shadow imaging and X-ray frame photography. The plasma density in the transition region is estimated. By comparing the experimental data with the results of simulations of quasi-steady implosion of a nested array with allowance for extended plasma production, the physical conditions are determined at which the implosion mode with the formation the shock region takes place. Stable compression of the plasma of the inner array was observed during the implosion of combined nested arrays with a fiber outer array and tungsten inner array. Suppression of magnetic Rayleigh-Taylor instability during the compression of the inner array plasma results in the formation of a compact radiating Z-pinch and generation of a soft X-ray pulse with a peak power of 4 TW and duration of about 5 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large-scale cascading of first-order FBG array in a highly multimode coreless fiber using femtosecond laser for distributed thermal sensing

This research focuses on the performance analysis and characterization of a fiber Bragg gratings (FBGs) array, consisting of 10 first-order FBGs inscribed by a femtosecond (FS) laser in a highly multimode coreless fiber. The study evaluates the FBG array's ability to function as a distributed thermal sensing (DTS) platform, with the coreless fiber chosen as the sensing element due to its immunity to dopant migration at high temperatures. The design of a large cascaded first-order FBG array effectively eliminates unwanted harmonic peaks across a wide spectrum range. In contrast, higher-order FBGs introduce limitations due to the overlapping of Bragg peaks with harmonics. The FBG array's performance is evaluated by measuring the reflection spectrum of each grating at different temperatures, showing a high temperature sensitivity of 15.05 pm/°C at a Bragg wavelength of 1606.3 nm, with a linear response in the temperature range of 24 - 1100 °C. The FBG array was designed for a spatial resolution of 5 mm. A mode scrambler in the sensing network is employed, which suppresses multimodal interference, characterizes FBG peak visibility, and stabilizes the interference spectrum. The stability of the FBG array is also assessed over 24 hrs at 1100 °C, and it is observed to be stable during thermal treatment. Heat treatment at 1100°C improves the signal to noise ratio of the FBG array, demonstrating the robustness and suitability of the proposed FBG array on highly multimode coreless fiber as a potential sensing platform for DTS applications in harsh environmental conditions, overcoming the issues of dopant migration presented by dopes silica optical fibers at high temperatures.

47 OTHER INSTRUMENTATION↗

Collective photonic-plasmonic resonances in noble metal - dielectric nanoparticle hybrid arrays

Coherent scattering of gold and silver nanoparticles (NPs) in regular arrays can generate Surface Lattice Resonances (SLRs) with characteristically sharp spectral features. Herein, we investigate collective resonances in compositionally more complex arrays comprising NP clusters and NPs with different chemical compositions at pre-defined lattice sites. We first characterize the impact of NP clustering by exchanging individual gold NPs in the array through dimers of electromagnetically strongly coupled gold NPs. Then, we analyze hybrid arrays that contain both gold metal NP dimers and high refractive index dielectric NPs as building blocks. We demonstrate that the integration of gold NP clusters and dielectric NPs into one array enhances E-field intensities not only in the vicinity of the NPs but also in the ambient medium of the entire array. In addition, this work shows that the ability to integrate multiple building blocks with different resonance conditions in one array provides new degrees of freedom for engineering optical fields in the array plane with variable amplitude and phase.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evaluation of Potential DAS Array Geometries for the Source Physics Experiment, Phase III

Distributed Acoustic Sensing (DAS) is a rapidly developing technology that can record acoustic wavefields at high sampling rates and with dense spatial spacing difficult to achieve with seismometers. However, the geophysical community has not fully explored DAS survey parameters to characterize the ideal array design. A better quantitative understanding of DAS array behavior prior to SPE Phase III acquisition can help improve the quality of the data recorded by guiding the DAS array design. Here we use array response functions as well as beamforming and backprojection results from forward modelling calculations to assess the performance of varying DAS array geometries to record regional and local sources. A seven-sided polygon DAS array demonstrated improved capabilities for recording regional sources over segmented linear arrays, with potential improvements in recording and locating local sources. These results help reveal DAS array performance as a function of geometry.

58 GEOSCIENCES↗

Performance of synthetic DAS as a function of array geometry

Distributed Acoustic Sensing (DAS) can record acoustic wavefields at high sampling rates and with dense spatial resolution difficult to achieve with seismometers. Using optical scattering induced by cable deformation, DAS can record strain fields with spatial resolution of a few meters. However, many experiments utilizing DAS have relied on unused, dark telecommunication fibers. As a result, the geophysical community has not fully explored DAS survey parameters to characterize the ideal array design. This limits our understanding of guiding principles in array design to deploy DAS effectively and efficiently in the field. A better quantitative understanding of DAS array behavior can improve the quality of the data recorded by guiding the DAS array design. Here we use steered response functions, which account for DAS fiber’s directional sensitivity, as well as beamforming and back-projection results from forward modelling calculations to assess the performance of varying DAS array geometries to record regional and local sources. A regular heptagon DAS array demonstrated improved capabilities for recording regional sources over other polygonal arrays, with potential improvements in recording and locating local sources. These results help reveal DAS array performance as a function of geometry and can guide future DAS deployments.

58 GEOSCIENCES↗

Casimir-Polder potential on an excited atom near an atomic array

We develop a microscopic description of the fluctuation-mediated Casimir-Polder (CP) shifts on a 'test' two-level atom placed near a two-dimensional atomic array of two-level atoms. We derive the resonant and off-resonant CP potentials experienced by the excited test atom using fourth-order perturbation theory, under the assumption that the test atom resonance is far detuned from those of the array atoms. The total potential on the test atom can be described as the sum of the pairwise resonant and off-resonant potentials resulting from its interaction with the individual atoms of the array. We analyze the asymptotic scaling of CP shifts as a function of the test atom-array separation, and its dependence on various system parameters: array spacing and size, and dipole orientation of the array atoms. Our results bridge the description of CP potential across two distinct regimes: (i) from a single-atom limit where we recover the well-known two-atom Van der Waals potential, (ii) to a macroscopic boundary limit, where we demonstrate new asymptotic scaling laws. We demonstrate that these scaling laws can be tuned via the microscopic parameters of the atomic array, establishing atomically-controlled arrays as a versatile platform for tailoring fluctuation-induced QED phenomena.

FOS: Physical sciences↗

SEPS solar array design and technology evaluation

The technology developments required and a preliminary design of a lightweight 25 kW solar array for the solar electric propulsion stage (SEPS) have been defined. The requirements for a 65 W/Kg SEPS solar array system requires significant component weight reductions over present state-of-the-art flexible solar arrays in both electrical and structural-mechanical designs. A requirement for operation from 0.3 au to 6.0 au presents a wide range of temperature environments as well as severe combined thermal/vacuum/UV radiation environments. Additional requirements are capability for partial array retraction operation, and capability for full retraction and automatic preloading for survival of the Shuttle reentry environment. An assessment of current lightweight flexible solar array technology is made against the SEPS solar array requirements and new technology requirements are defined. A preliminary design and the operating characteristics of a flat-fold solar array system meeting the SEPS requirements is presented. A full-width, 10-ft-tall functional array model, including representative welded electrical modules and a model astromast, was fabricated and tested.

Elms, R. V., Jr.↗