Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

PHARAO laser source flight model: Design and performances

In this paper, we describe the design and the main performances of the PHARAO laser source flight model. PHARAO is a laser cooled cesium clock specially designed for operation in space and the laser source is one of the main sub-systems. The flight model presented in this work is the first remote-controlled laser system designed for spaceborne cold atom manipulation. The main challenges arise from mechanical compatibility with space constraints, which impose a high level of compactness, a low electric power consumption, a wide range of operating temperature, and a vacuum environment. We describe the main functions of the laser source and give an overview of the main technologies developed for this instrument. We present some results of the qualification process. The characteristics of the laser source flight model, and their impact on the clock performances, have been verified in operational conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparative analysis of GPS range, Doppler and interferometric observations for geodetic positioning

Geodetic positioning accuracies obtained from range, integrated Doppler and double differenced interferometric phase observations from a constellation of twenty-four Global Positioning System satellites are presented. It is demonstrated the GPS range and Doppler observations will provide sufficient accuracy for the estimation of geodetic coordinates. However the instability of the receiver atomic oscillator will limit the usefulness of these observations in providing rapid first-order baseline determination. Interferometric phase measurements twice differenced to eliminate clock error appear as an alternate procedure for providing such accuracies.

Fell, P. J.↗

Progress Report on the Improved Linear Ion Trap Physics Package

This article describes the first operational results from the extended linear ion trap frequency standard now being developed at JPL. This new design separates the state selection/interrogation region from the more critical microwave resonance region where the multiplied local oscillator (LO) signal is compared to the stable atomic transition. Hg+ ions have been trapped, shuttled back and forth between the resonance and state selection traps. In addition, microwave transitions between the Hg+ clock levels have been driven in the resonance trap and detected in the state selection trap.

Linear Ion Trap↗

Transverse-Field Ising Dynamics in a Rydberg-Dressed Atomic Gas

Here, we report on the realization of long-range Ising interactions in a cold gas of cesium atoms by Rydberg dressing. The interactions are enhanced by coupling to Rydberg states in the vicinity of a Förster resonance. We characterize the interactions by measuring the mean-field shift of the clock transition via Ramsey spectroscopy, observing one-axis twisting dynamics. We furthermore emulate a transverse-field Ising model by periodic application of a microwave field and detect dynamical signatures of the paramagnetic-ferromagnetic phase transition. Our results highlight the power of optical addressing for achieving local and dynamical control of interactions, enabling prospects ranging from investigating Floquet quantum criticality to producing tunable-range spin squeezing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thorium-doped CsI: Implications for the thorium nuclear clock transition

For 229m Th isomer nucleus with an anomalously low nuclear excitation energy, E$\star$ (currently accepted value of 7.8 ± 0.5 eV), the bound internal conversion (BIC) decay process is caused by the excitation of a valence electron that is sensitive to the electronic structure of the atomic-sized neighborhood. For this, we analyze an experiment where an impacting Th ion is neutralized by a negatively charged ion-receiving cesium iodide (CsI) surface, to obtain the minimal nuclear excitation energy E$\star\atop{min}$ necessary for BIC promotion of a Th-impurity valence electron in a CsI matrix. We analyze two cases: CsI with Th deposited into the bulk and with Th deposited on the CsI surface. In the bulk we consider band gap effects while on the surface we consider the work function. The energy to pull the electron to the surface is 1.5 – 2.2 eV depending on the surface plane, while to promote to the conduction band in the bulk it is 1.5 eV. Therefore we conclude that the Th-surface interaction can significantly reduce the lower E$\star$ bound of 6.3 eV, as estimated from the direct observation of the Th-clock transition [von der Wense et al., Nature (London) 533, 47 (2016)]. We suggest coating the multichannel plate with differing materials leading to different Th-impurity gaps and work functions can further narrow the E$\star$ uncertainty interval.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

F-state quenching with CH{sub 4} for buffer-gas cooled {sup 171}Y b{sup +} frequency standard

We report that methane, CH{sub 4}, can be used as an efficient F-state quenching gas for trapped ytterbium ions. The quenching rate coefficient is measured to be (2.8 ± 0.3) × 10{sup 6} s{sup −1} Torr{sup −1}. For applications that use microwave hyperfine transitions of the ground-state {sup 171}Y b ions, the CH{sub 4} induced frequency shift coefficient and the decoherence rate coefficient are measured as δν/ν = (−3.6 ± 0.1) × 10{sup −6} Torr{sup −1} and 1/T{sub 2} = (1.5 ± 0.2) × 10{sup 5} s{sup −1} Torr{sup −1}. In our buffer-gas cooled {sup 171}Y b{sup +} microwave clock system, we find that only ≤10{sup −8} Torr of CH{sub 4} is required under normal operating conditions to efficiently clear the F-state and maintain ≥85% of trapped ions in the ground state with insignificant pressure shift and collisional decoherence of the clock resonance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical Frequency Stabilization and Optical Phase Locked Loops: Golden Threads of Precision Measurement

Stabilization of lasers through locking to optical cavities, atomic transitions, and molecular transitions has enabled the field of precision optical measurement since shortly after the invention of the laser. Recent advances in the field have produced an optical clock that is orders of magnitude more stable than those of just a few years prior. Phase locking of one laser to another, or to a frequency offset from another, formed the basis for linking stable lasers across the optical spectrum, such frequency chains exhibiting progressively finer precision through the years. Phase locking between the modes within a femtosecond pulsed laser has yielded the optical frequency comb, one of the most beautiful and useful instruments of our time. This talk gives an overview of these topics, from early work through to the latest 1E-16 thermal noise-limited precision recently attained for a stable laser, and the ongoing quest for ever finer precision and accuracy. The issues of understanding and measuring line widths and shapes are also studied in some depth, highlighting implications for servo design for sub-Hz line widths.

Golden Threads↗

The cosmic-ray age deduced from the Be-10 abundance

Satellite measurements of the radioactive cosmic-ray species Be-10 are reported. The abundance was measured near 100 MeV per nucleon with high-resolution solid-state telescopes on the IMP-7 and IMP-8 satellites during 1973 and 1974. These two independent measurements yield Be-10/Be ratios of less than 10 percent. Taken together with a galactic propagation model, these results show that the cosmic-ray 'clock' lifetime (most probable value of the order of 20 million years) is significantly greater than that deduced for a nominal interstellar gas density of the order of 1 to 3 atoms per cu cm.

Garcia-Munoz, M.↗

Speedup of UEDGE Parameter Scans Using Machine-Learning Optimized OpenMP Parallelization and a Continuation Solver

This article presents the OpenMP parallelization of the preconditioning Jacobian assembly and right‐hand side residual evaluation in UEDGE. A continuation algorithm, utilizing the internal NKSOL implicit Jacobian‐Free Newton‐Krylov solver to efficiently scan physical parameters, is also presented. The implemented parallelization reduces the computational time for a benchmark scan run on 32 threads by compared to the serial version when using trained random forest regression models to identify the optimal decomposition of the system of equations. Random forest regression models applied to the UEDGE time‐dependent and continuation solver algorithms did not yield meaningful improvement in computational performance. A benchmark DIII‐D gas injection rate scan in the 0.35–0.75 kA interval, performed on a test cluster using the parallelized code and continuation solver, produced 1066 steady‐state solutions with a 22 s average wall‐clock computational time per steady‐state solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Closely spaced nanomagnets by dual e-beam exposure for low-energy nanomagnet logic

The effect of nanomagnet spacing on required clock field has been studied by micromagnetic simulation for supermalloy (Ni{sub 79}Fe{sub 16}Mo{sub 5}) dots with dimensions 90 Multiplication-Sign 60 Multiplication-Sign 20 nm{sup 3} and 120 Multiplication-Sign 60 Multiplication-Sign 20 nm{sup 3}. Reduction of the inter-magnet spacing for both dimensions has resulted in reduction of the required clock field in the simulation. A dual e-beam exposure technique has been developed to allow fabrication of ultra dense features using conventional poly(methylmethacrylate) e-beam resist. Nanomagnet logic (NML) datalines of supermalloy dots with {approx}10 nm and {approx}15 nm spacing have been fabricated using dual e-beam exposure with a 3{sigma} overlay accuracy of {approx}4 nm. Fabricated NML datalines have been characterized using magnetic force microscopy for various clock fields. Datalines of both spacing have shown proper NML functionality with a clock field as low as 60 mT.

36 MATERIALS SCIENCE↗

Classical analog of quantum models in synthetic dimensions

We introduce a classical analog of quantum matter in ultracold molecule-synthetic or Rydberg atom-synthetic dimensions, by extending the Potts model to include interactions J 1 between atoms adjacent in both real and synthetic space and studying its finite-temperature properties. For intermediate values of J 1 , the resulting phases and phase diagrams are similar to those of the clock and Villain models, in which three phases emerge. There exists a sheet phase analogous to that found in quantum synthetic dimension models between the high-temperature disordered phase and the low-temperature ferromagnetic phase. Furthermore, we also employ machine learning to uncover nontrivial features of the phase diagram using the learning by confusion approach, which is able to discern several successive phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum arrival and dwell times via idealized clocks

A number of approaches to the problem of defining arrival- and dwell-time probabilities in quantum theory makes use of idealized models of clocks. An interesting question is the extent to which the probabilities obtained in this way are related to standard semiclassical results. In this paper, we explore this question using a reasonably general clock model, solved using path-integral methods. We find that, in the weak-coupling regime, where the energy of the clock is much less than the energy of the particle it is measuring, the probability for the clock pointer can be expressed in terms of the probability current in the case of arrival times, and the dwell-time operator in the case of dwell times, the expected semiclassical results. In the regime of strong system-clock coupling, we find that the arrival-time probability is proportional to the kinetic-energy density, consistent with an earlier model involving a complex potential. We argue that, properly normalized, this may be the generically expected result in this regime. We show that these conclusions are largely independent of the form of the clock Hamiltonian.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spaceborne clock system: Some alternatives for a proposed NASA experiment

A spaceborne clock experiment is proposed with the objectives of improving international time and frequency comparisons, studying precise one-way Doppler tracking and one-way ranging techniques, performing relativistic studies, and developing new atomic frequency standards technology. Various alternatives are considered for accomplishing these goals, including the use of existing satellite and earth-based time dissemination systems as well as the development of a new frequency standard for this specific application. One conclusion is that several attractive alternatives already exist for meeting the goal of improved time and frequency dissemination. However, to achieve all the other 4 goals at the NASA-stated levels of accuracy, a spaceborne atomic frequency standard may be required. An analysis of achievements to date with quartz oscillators, rubidium standards, cesium beam standards, hydrogen masers, and several other possibilities leads to the conclusion that cesium and rubidium standards offer the best choices for the experiment as proposed by NASA. The greatest obstacle to a spaceborne atomic standard appears to be its electrical power requirements.

Beehler, R. E.↗

GPS Monitor Station Upgrade Program at the Naval Research Laboratory

One of the measurements made by the Global Positioning System (GPS) monitor stations is to measure the continuous pseudo-range of all the passing GPS satellites. The pseudo-range contains GPS and monitor station clock errors as well as GPS satellite navigation errors. Currently the time at the GPS monitor station is obtained from the GPS constellation and has an inherent inaccuracy as a result. Improved timing accuracy at the GPS monitoring stations will improve GPS performance. The US Naval Research Laboratory (NRL) is developing hardware and software for the GPS monitor station upgrade program to improve the monitor station clock accuracy. This upgrade will allow a method independent of the GPS satellite constellation of measuring and correcting monitor station time to US Naval Observatory (USNO) time. THe hardware consists of a high performance atomic cesium frequency standard (CFS) and a computer which is used to ensemble the CFS with the two CFS's currently located at the monitor station by use of a dual-mixer system. The dual-mixer system achieves phase measurements between the high-performance CFS and the existing monitor station CFS's to within 400 femtoseconds. Time transfer between USNO and a given monitor station is achieved via a two way satellite time transfer modem. The computer at the monitor station disciplines the CFS based on a comparison of one pulse per second sent from the master site at USNO. The monitor station computer is also used to perform housekeeping functions, as well as recording the health status of all three CFS's. This information is sent to the USNO through the time transfer modem. Laboratory time synchronization results in the sub nanosecond range have been observed and the ability to maintain the monitor station CFS frequency to within 3.0 x 10 (sup minus 14) of the master site at USNO.

Galysh, Ivan J.↗

The elemental and isotopic composition of galactic cosmic rays

Galactic cosmic rays represent samples of matter from areas outside the solar system. New information regarding the elemental composition of cosmic rays has been obtained in connection with the French-Danish experiment on HEA0-3 and recent balloon experiments. The energy dependence of the source composition is considered along with a comparison of cosmic ray and solar system abundances, and the N-14 source abundance. Attention is given to cosmic ray clocks and the Mn-54 problem, advances concerning cross section measurements, and cosmic ray isotopes. The considered new observations suggest that cosmic ray elemental abundance differences from the solar system continue to be ordered by atomic parameters such as first ionization potential, at least up through Z equals 40. The isotopic composition of the cosmic ray source is found to be unlike that of the solar system.

Mewaldt, R. A.↗

Electron-ion coincidence measurements of molecular dynamics with intense X-ray pulses

Molecules can sequentially absorb multiple photons when irradiated by an intense X-ray pulse from a free-electron laser. If the time delay between two photoabsorption events can be determined, this enables pump-probe experiments with a single X-ray pulse, where the absorption of the first photon induces electronic and nuclear dynamics that are probed by the absorption of the second photon. Here we show a realization of such a single-pulse X-ray pump-probe scheme on N 2 molecules, using the X-ray induced dissociation process as an internal clock that is read out via coincident detection of photoelectrons and fragment ions. By coincidence analysis of the kinetic energies of the ionic fragments and photoelectrons, the transition from a bound molecular dication to two isolated atomic ions is observed through the energy shift of the inner-shell electrons. Via ab-initio simulations, we are able to map characteristic features in the kinetic energy release and photoelectron spectrum to specific delay times between photoabsorptions. In contrast to previous studies where nuclear motions were typically revealed by measuring ion kinetics, our work shows that inner-shell photoelectron energies can also be sensitive probes of nuclear dynamics, which adds one more dimension to the study of light-matter interactions with X-ray pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗