Search NASASearch

SEARCH · Search NASA

Results for “battery storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

554 records · Page 27

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery

Battery/Ultracapacitor Evaluation for X-38 Crew Return Vehicle (CRV)

This presentation reported on the evaluation of the battery/ultracapacitor for the crew return vehicle (CRV). The CRV, as part of the international space station (ISS) planning, will be available to return to earth an ill or injured crew person, or if the ISS becomes unsafe, and the shuttle is not available. The requirements of the X-38 CRV are reviewed, and in light of the power requirements, the battery's required performance is reviewed. The ultracapacitor bank, and its test method is described. The test results are reviewed. A picture of the test set up is displayed showing the ultracapacitor bank and the NiMH battery. The presentation continues by reviewing tests of 5 available trade high power cell designs: (1) Hawker lead acid, (2) Bolder lead acid, (3) Energizer NiMH, (4) Sanyo NiCd, and (5) Energizer NiCd. The test methods and results are reviewed. There is also a review of the issues concerning lead acid batteries and conclusions.

Darcy, Eric

AUSSAT battery life test program

AUSSAT Pty. Ltd., the Australian National Satellite organization, has contracted with the Hughes Aircraft Company (HAC) for the construction of 3 satellites based on the now familiar HS-376 product line. As part of the AUSSAT contract, HAC is conducting an extensive NiCd battery life test program. The life test program, objectives and test results to date are described. Particular emphasis is given to the evaluation of the FS2117 separator as a future replacement for the Pellon 2505 separator of which only a very limited quantity remains.

Gorian, P. W.

A review of nickel hydrogen battery technology

This paper on nickel hydrogen batteries is an overview of the various nickel hydrogen battery design options, technical accomplishments, validation test results and trends. There is more than one nickel hydrogen battery design, each having its advantage for specific applications. The major battery designs are individual pressure vessel (IPV), common pressure vessel (CPV), bipolar and low pressure metal hydride. State-of-the-art (SOA) nickel hydrogen batteries are replacing nickel cadmium batteries in almost all geosynchronous orbit (GEO) applications requiring power above 1 kW. However, for the more severe low earth orbit (LEO) applications (greater than 30,000 cycles), the current cycle life of 4000 to 10,000 cycles at 60 percent DOD should be improved. A NASA Lewis Research Center innovative advanced design IPV nickel hydrogen cell led to a breakthrough in cycle life enabling LEO applications at deep depths of discharge (DOD). A trend for some future satellites is to increase the power level to greater than 6 kW. Another trend is to decrease the power to less than 1 kW for small low cost satellites. Hence, the challenge is to reduce battery mass, volume and cost. A key is to develop a light weight nickel electrode and alternate battery designs. A common pressure vessel (CPV) nickel hydrogen battery is emerging as a viable alternative to the IPV design. It has the advantage of reduced mass, volume and manufacturing costs. A 10 Ah CPV battery has successfully provided power on the relatively short lived Clementine Spacecraft. A bipolar nickel hydrogen battery design has been demonstrated (15,000 LEO cycles, 40 percent DOD). The advantage is also a significant reduction in volume, a modest reduction in mass, and like most bipolar designs, features a high pulse power capability. A low pressure aerospace nickel metal hydride battery cell has been developed and is on the market. It is a prismatic design which has the advantage of a significant reduction in volume and a reduction in manufacturing cost.

Smithrick, John J.

High Capacity Battery Cell Flight Qualified

The High Capacity Battery Cell project is an effort equally funded by the NASA Lewis Research Center and Hughes Space and Communications Company (a unit of Hughes Aircraft Company) to develop and flight qualify a higher capacity nickel hydrogen battery for continuing use on commercial spacecraft. The larger diameter, individual pressure vessel cell will provide approximately twice the power, while occupying the same volume, as the current state-of-the-art nickel hydrogen cell. These cells are also anticipated to reduce battery cost by 20 percent. The battery is currently booked for use on 26 spacecraft, with the first flight scheduled in 1997. A strong requirement for batteries with higher power levels (6 to 12 kW), long life, and reduced cost was identified in studies of the needs of commercial communications spacecraft. With the design developed in this effort, the higher power level was accommodated without having to modify the rest of the existing spacecraft bus. This design scaled-up the existing state-of-the-art nickel hydrogen battery cell from a 3.5-in., 50-Ahr cell to a 5.5-in., 350-Ahr cell. An improvement in cycle life was also achieved by the use of the 26-percent KOH electrolyte design developed by NASA Lewis. The cell design was completed, and flight batteries were built and flight qualified by Hughes Space and Communications Company with input from NASA Lewis. Two batteries were shipped in September 1996 to undergo life cycle testing under the purview of NASA Lewis.

McKissock, Barbara I.

A Battery Charger and State of Charge Indicator

A battery charger which has a full wave rectifier in series with a transformer isolated 20 kHz dc-dc converter with high frequency switches, which are programmed to actively shape the input dc line current to be a mirror image of the ac line voltage is discussed. The power circuit operates at 2 kW peak and 1 kW average power. The BC/SCI has two major subsystems: (1) the battery charger power electronics with its controls; and (2) a microcomputer subsystem which is used to acquire battery terminal data and exercise the state of charge software programs. The state of charge definition employed is the energy remaining in the battery when extracted at a 10 kW rate divided by the energy capacity of a fully charged new battery. The battery charger circuit is an isolated boost converter operating at an internal frequency of 20 kHz. The switches selected for the battery charger are the single most important item in determining its efficiency. The combination of voltage and current requirements dictate the use of high power NPN Darlington switching transistors. The power circuit topology is a three switch design which utilizes a power FET on the center tap of the isolation transformer and the power Darlingtons on each of the two ends. An analog control system is employed to accomplish active input current waveshaping as well as the necessary regulation.

Latos, T. S.

Safe, High Power / Voltage Battery Design Challenges

NASA seeks safe, high performing battery module designs that can deliver 3C discharge rates continuously, achieve 160 Wh/kg, and is passively propagation resistant to a single cell thermal runaway event. One solution is presented that uses a patented oscillating heat pipe technology for thermal management. Combined with light weight packaging and a new commercially available gas permeable vent port, all 5 preliminary safety tests results performed to date are showing ample margins.

High power

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi

Overview of the Center for Advanced Space Propulsion

The mission of the Center for Advanced Space Propulsion (CASP), a Center for the Commercial Development of Space (CCDS), is to strengthen U.S. competitiveness in space technology, foster cooperative research with industry and government, assist industry in developing commercial products and services, and perform research in advanced space propulsion. Current areas of focus are (1) advanced chemical propulsion, including high area ratio nozzle performance, variable thrust engine performance, and spray combustion stability; (2) artificial intelligence propulsion applications, including health monitoring of rocket engines, fault pattern detection and diagnosis, and intelligent hypertext applications; (3) microgravity fluid management, including liquid storage and transfer, a subscale orbital fluid transfer experiment, and helical, two-phase flow; (4) electric propulsion, including magnetic annular arc thruster, ion thrustor, and electrostatic plasma accelerator; and (5) laser materials processing.

George W Garrison

Lead-acid battery

A light weight lead-acid battery (30) having a positive terminal (36) and a negative terminal (34) and including one or more cells or grid stacks having a plurality of vertically stacked conductive monoplates (10, 20) with positive active material and negative active material deposited on alternating plates in the cell or grid stack. Electrolyte layers (26, 28) positioned between each monoplate are included to provide a battery cell having four sides which is capable of being electrically charged and discharged. Two vertical positive bus bars (42, 43) are provided on opposite sides of the battery cell for connecting the monoplates (10) with positive active material together in parallel current conducting relation. In addition, two negative bus bars (38, 39) on opposite sides of the battery cell each being adjacent the positive bus bars are provided for connecting the monoplates (20) with negative active material together in parallel current conducting relation. The positive (42, 43) and negative (38, 39) bus bars not only provide a low resistance method for connecting the plurality of conductive monoplates of their respective battery terminals (36, 34) but also provides support and structural strength to the battery cell structure. In addition, horizontal orientation of monoplates (10, 20) is provided in a vertical stacking arrangement to reduce electrolyte stratification and short circuiting due to flaking of positive and negative active materials from the monoplates.

Rowlette, John J.

Life cycle test results of a bipolar nickel hydrogen battery

A history is given of low Earth orbit (LEO) laboratory test data on a 6.5 ampere-hour bipolar nickel hydrogen battery designed and built at the NASA Lewis Research Center. The bipolar concept is a means of achieving the goal of producing an acceptable battery, of higher energy density, able to withstand the demands of low-Earth-orbit regimes. Over 4100 LEO cycles were established on a ten cell battery. It seems that any perturbation on normal cycling effects the cells performance. Explanations and theories of the battery's behavior are varied and widespread among those closely associated with it. Deep discharging does provide a reconditioning effect and further experimentation is planned in this area. The battery watt-hour efficiency is about 75 percent and the time averaged, discharge voltage is about 1.26 volts for all cells at both the C/4 and LEO rate. Since a significant portion of the electrode capacity has degraded, the LEO cycle discharges are approaching depths of 90 to 100 percent of the high rate capacity. Therefore, the low end-of-discharge voltages occur precipitously after the knee of the discharge curve and is more an indication of electrode capacity and is a lesser indicator of overall cell performance.

Cataldo, R. L.

Battery test expert systems

The characteristics of NIHBES (nickel-hydrogen battery expert system) are described, with attention also given to NICBES-2 (nickel-cadmium battery expert system-2). The nickel-hydrogen battery testbed is set up almost identically to the nickel-cadmium battery testbed, with the exceptions of no battery protection and reconditioning circuits (BPRCs) and the frequency of transmission of data. The Ni-H2 testbed has no BPRCs and the data are transmitted every 30 s instead of every minute. An expert system shell was chosen to develop this particular expert system. The GoldWorks expert system shell from Gold Hill Computers was chosen for the task. NIHBES will extract the desired data and return fault diagnosis, status and advice, and decision support. Expert systems have been proven to be viable tools in the control and monitoring of space power systems. Presently, the DDAS (digital data acquisition system) monitors and controls the orbit time, and is responsible for limit checking, data acquisition, and data summaries. It is concluded that in the future control of the Hubble Space Telescope breadboard will be passed to NIHBES. NIHBES will be more beneficial to the testbed than the DDAS alone due to the limitations of the DDAS. The DDAS cannot provide long-term trend analysis, plotting capability, fault diagnosis, or advice.

Johnson, Yvette B.

Composite battery separator

A composite battery separator comprises a support element (10) having an open pore structure such as a ribbed lattice and at least one liquid permeable sheet (20,22) to distribute the compressive force evenly onto the surfaces of the layers (24, 26) of negative active material and positive active material. In a non-flooded battery cell the compressible, porous material (18), such as a glass mat which absorbs the electrolyte, is compressed into a major portion of the pores or openings (16) in the support element. The unfilled pores in the material (18) form a gas diffusion path as the channels (41) formed between adjacent ribs in the lattice element (30,36). Facing two lattice elements (30, 31) with acute angled cross-ribs (34, 38) facing each other prevents the elements from interlocking and distorting a porous, separator (42) disposed between the lattice elements.

Edwards, Dean B.

Hypervelocity Impact Testing of Nickel Hydrogen Battery Cells

Nickel-Hydrogen (Ni/H2) battery cells have been used on several satellites and are planned for use on the International Space Station. In January 1992, the NASA Lewis Research Center (LeRC) conducted hypervelocity impact testing on Ni/H2 cells to characterize their failure modes. The cell's outer construction was a 24 mil-thick Inconel 718 pressure vessel. A sheet of 1.27 cm thick honeycomb was placed in front of the battery cells during testing to simulate the on-orbit box enclosure. Testing was conducted at the NASA White Sands Test Facility (WSTF). The hypervelocity gun used was a 7.6 mm (0.30 caliber) two-stage light gas gun. Test were performed at speeds of 3, 6, and 7 km/sec using aluminum 2017 spherical particles of either 4.8 or 6.4 mm diameter as the projectile. The battery cells were electrically charged to about 75 percent of capacity, then back-filled with hydrogen gas to 900 psi simulating the full charge condition. High speed film at 10,000 frames/sec was taken of the impacts. Impacts in the dome area (top) and the electrode area (middle) of the battery cells were investigated. Five tests on battery cells were performed. The results revealed that in all of the test conditions investigated, the battery cells simply vented their hydrogen gas and some electrolyte, but did not burst or generate any large debris fragments.

Frate, David T.

FAST Spacecraft Battery Design and Performance

The Fast Auroral Snapshot (FAST) Explorer spacecraft is to study the physical processes that produce the aurora borealis and aurora australis. It is a unique plasma physics experiment that will take fundamental measurements of the magnetic and electrical fields. This investigation will add significantly to our understanding of the near-earth space environments and its effect. The FAST has a 1 year requirement and 3-year goal for its mission life in low earth orbit. The FAST power power system topology is a Direct Energy Transfer (DET) system based on the SAMPEX design. The FAST flight battery supplies power to the satellite during pre-launch operations, the launch phase, the eclipse periods for all mission phases, and when the load is about 50 watts.

Jung, David S.