Expansion of input capability for electronic scene generator, instruction manual Final report
Characteristics of self-powered, multichannel digital data buffer designed to expand input capability of electronic scene generator
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Characteristics of self-powered, multichannel digital data buffer designed to expand input capability of electronic scene generator
Data acquisition and processing system with buffer storage and timing device for magnetic tape recording of PCM data and timing information
SFOF digital television hardcopy equipment, consisting of system control unit, 12 copy request units, display image buffer, and 12 hardcopy printers
The modifications to the Houston/MSC design of the gas proportional counter flight electronics system are discussed. The following modifications are described: charge amplifier bandwidth improvements, power converter redesign, serial data output buffer, second differentiator, and risetime discriminator. In addition, the redesign of the stellar aspect camera is discussed along with developments in thin film fabrication.
Several types of amplifiers and amplifier systems are considered. These include preamplifiers, high power amplifiers, buffer and isolation amplifiers, amplifier circuits, and general purpose amplifiers.
A microdensitometer, scanning pairs of star plates of identical areas of the sky taken a decade apart, is coupled to a magnetic tape unit through a data acquisition system. This system performs an image density threshold level selection for each plate and a buffer memory system to smooth the data flow as well as analog and digital display controls. The data from the tape are processed later by a large scale high speed computer which reconstructs the scanned images, discovers, measures, and documents stellar proper motions by precise comparison of corresponding areas of the two star plates to detect those images which have moved at least 0.10 seconds annually in the time interval between the exposures.
The assembly drawings of the receiver unit are presented for the data compression/error correction digital test system. Equipment specifications are given for the various receiver parts, including the TV input buffer register, delta demodulator, TV sync generator, memory devices, and data storage devices.
Using a point model of an in-core thermionic converter, alternative schemes for providing closed loop reactor control were investigated. It was found that schemes based on variable gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small-even for a complete electric load drop the emitter temperature transient is less than 100 deg K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that even though the emitter temperature distribution is about 200 deg K along the converter length, the dynamic properties are unchanged when using the current control scheme.
A conceptual optical method and some test results are presented for measuring the surface temperature distribution on one of the rotating turbine blades with a surface resolution of 0.05 cm spot diameter at a tip speed of 400 m/sec. The blade is scanned line-by-line by a fixed optical system. During each line-scan, the detector analog output signal is converted to two hundred consecutive digital values that are temporarily stored in a high speed buffer memory, and then transferred at a slower rate to a computer for processing. The signal-to-noise ratio of the silicon avalanche detector is large enough to obtain an accuracy of one percent at 1050 K blade temperature. By averaging 25 scans of the same line the same accuracy can be obtained at 900 K.
Carbon dioxide in a helium buffer at room temperature was irradiated with a photon beam. The wavelengths used in the investigation were in the range from 850 to 1090 A. Phosphorescence from CO Cameron bands was observed. The phosphorescent yield is zero at threshold and increases smoothly to a maximum of about 60% near 900 A. The smoothness of the percentage yield was an unexpected observation and is explained by postulating that the relevant potential surface crossings are outside the Franck-Condon region of carbon dioxide absorption.
Use of a point model of an in-core thermionic converter to investigate alternative schemes for providing closed-loop reactor control. It was found that schemes based on variable-gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small; even for a complete electric load drop the emitter temperature transient is less than 100 K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that, even though the emitter temperature distribution is about 200 K along the converter length, the dynamic properties are unchanged when using the current control scheme.
Commercially available equipment can be modified to provide automated system for assaying drug metabolism by continuous flow-through. System includes steps and devices for mixing drug with enzyme and cofactor in the presence of pure oxygen, dialyzing resulting metabolite against buffer, and determining amount of metabolite by colorimetric method.
Centrifugal force causes buffer, chosen to be denser than particles, to move outward and particles to move inward. Electrophoresis force can be made to equal centrifugal force. System tends not to be affected by convection and other disturbances that are so troublesome in conventional electrophoresis systems.
Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).
The experimental and theoretical investigations conducted during the period from September 1969 through September 1972 are reported which were directed toward obtaining information necessary to determine the feasibility of the full-scale nuclear light bulb engine, and of small-scale nuclear tests involving fissioning uranium plasmas in a unit cell installed in a driver reactor, such as the Nuclear Furnace. Emphasis was placed on development of RF simulations of conditions expected in nuclear tests in the Nuclear Furnace. The work included investigations of the following: (1) the fluid mechanics and containment characteristics of one-component and two-component vortex flows, both unheated and RF-induction heated; (2) heating of particle-seeded streams by thermal radiation from a dc arc to simulate propellant heating; (3) condensation and separation phenomena for metal-vapor/heated-gas mixtures to provide information for conceptual designs of components of fuel exhaust and recycle systems; (4) the characteristics of the radiant energy spectrum emitted from the fuel region, with emphasis on definition of fuel and buffer-gas region seed systems to reduce the ultraviolet radiation emitted from the nuclear fuel; and (5) the effects of nuclear radiation on the optical transmission characteristics of transparent materials.
An abradable buffered labyrinth seal for the control of turbine gas path leakage in a tip-turbine driven lift fan was designed, tested, and analyzed. The seal configuration was not designed to operate in any specific location but was sized to be evaluated in an existing test rig. The final sealing diameter selected was 28 inches. Results of testing indicate that the flow equations predicted seal air flows consistent with measured values. Excellent sealing characteristics of the abradable coating on the stator land were demonstrated when a substantial seal penetration of .030 inch into the land surface was encountered without appreciable wear on the labyrinth knife edges.
Problems in collecting and shipping human sera for clinical chemical analyses affect their stability and require proper preservation methods. It is shown that glutamic pyruvate transaminase is very unstable and serum cannot be shipped unless the shipping time is carefully controlled and is less than two days under refrigeration. A limit of four days handling time and avoidance of light exposure are required in bilirubin testing of specimens. Addition of 11 mg of a 10 to 1 mixture of finely powdered sodium fluoride and thymol per ml of blood to preserve specimen stability en route to a central laboratory prevents glycolysis. A citrate buffer at pH 6.2 in serum to be tested for alkaline phosphatase lessens decline at room temperature.
A zero-power critical assembly was designed, constructed, and operated for the prupose of conducting a series of benchmark experiments dealing with the physics characteristics of a UN-fueled, Li-7-cooled, Mo-reflected, drum-controlled compact fast reactor for use with a space-power conversion system. The critical assembly was modified to simulate a fast spectrum advanced thermionics reactor by: (1) using BeO as a reflector in place of some of the existing molybdenum, (2) substituting Nb-1Zr tubing for some of the existing Ta tubing, and (3) inserting four full-scale mockups of thermionic type fuel elements near the core and BeO reflector boundary. These mockups were surrounded with a buffer zone having the equivalent thermionic core composition. In addition to measuring the critical mass of this thermionic configuration, a detailed power distribution in one of the thermionic element stages in the mixed spectrum region was measured. A power peak to average ratio of two was observed for this fuel stage at the midplane of the core and adjacent to the reflector. Also, the power on the outer surface adjacent to the BeO was slightly more than a factor of two larger than the power on the inside surface of a 5.08 cm (2.0 in.) high annular fuel segment with a 2.52 cm (0.993 in. ) o.d. and a 1.86 cm (0.731 in.) i.d.