Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Experimental study of the downstream effect of LOCA-generated debris on the pressure drop of full scale fuel assembly

The emergency core cooling system (ECCS) works to cool the reactor core in the event of a postulated loss-of-coolant accident (LOCA). The long-term reactor cooling water of ECCS comes from containment sump. Usually, the containment sump contains one or more screens to prevent the components of the ECCS from debris which could be washed into the sump. Large debris is blocked by the sump screens. However, some of the debris, such as fibrous, chemical precipitates and small particles may be ingested into the ECCS and subsequently into the reactor coolant systems (RCS), which would challenge the long-term core cooling (LTCC) and threaten the reactor core safety. NRC address this concern Generic Letter 2004-02. Westinghouse has evaluated the AP1000 1/4 height fuel assembly head-loss test in response to the issue. AVERA also perform the scaled 1/3 height mock-up fuel assembly test. The debris effect on the pressure drop of half-length mock-up PLUS7 fuel assembly of APR1400 were performed in KHNP. Numerical simulation by RELAP5-3D were performed for the debris-generated core blockage and full core as well as core bypass blockage condition were considered. However, the test in the works mentioned above use the scaled down FA (1/4, 1/3 or 1/2 length of a full FA), and didn't give the relationship between pressure drop and debris batches. The purpose of this study was to extend the debris effect to the full scale PWR fuel assembly, and identified batch by batch effect of debris to head loss of FA. The specific experimental procedure is concluded. The pressure drop test without adding debris is performed at the beginning and then three kinds of debris are added to the test loop step by step to test their effect on the pressure drop of fuel assembly. Two kinds of tests have been carried out, and the quantitative pressure data are obtained and analysis is provided. This work provides reliable and quantitative data for nuclear power plant (NPP) downstream effect analysis and safety analysis program, which is important to for licensing of NPP and further benchmark exercise. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reconstruction of the primordial power spectrum of curvature perturbations using multiple data sets

Detailed knowledge of the primordial power spectrum of curvature perturbations is essential both in order to elucidate the physical mechanism ('inflation') which generated it, and for estimating the cosmological parameters from observations of the cosmic microwave background and large-scale structure. Hence it ought to be extracted from such data in a model-independent manner, however this is difficult because relevant cosmological observables are given by a convolution of the primordial perturbations with some smoothing kernel which depends on both the assumed world model and the matter content of the universe. Moreover the deconvolution problem is ill-conditioned so a regularisation scheme must be employed to control error propagation. We demonstrate that 'Tikhonov regularisation' can robustly reconstruct the primordial spectrum from multiple cosmological data sets, a significant advantage being that both its uncertainty and resolution are then quantified. Using Monte Carlo simulations we investigate several regularisation parameter selection methods and find that generalised cross-validation and Mallow's C{sub p} method give optimal results. We apply our inversion procedure to data from the Wilkinson Microwave Anisotropy Probe, other ground-based small angular scale CMB experiments, and the Sloan Digital Sky Survey. The reconstructed spectrum (assuming the standard ΛCDM cosmology) is not scale-free but has an infrared cutoff at k∼<5 × 10{sup −4} Mpc{sup −1} (due to the anomalously low CMB quadrupole) and several features with ∼ 2σ significance at k/Mpc{sup −1} ∼ 0.0013–0.0025, 0.0362–0.0402 and 0.051–0.056, reflecting the 'WMAP glitches'. To test whether these are indeed real will require more accurate data, such as from the Planck satellite and new ground-based experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel utilization of 3D technology and the hybrid operating theatre: Peri-operative assessment of posterior sterno-clavicular dislocation using cone beam CT

A patient with a medial and posterior dislocation of the right sterno-clavicular (SC) joint and displacement of the trachea and brachiocephalic artery by the medial head of the clavicle underwent general anaesthetic in the operating theatre for an open reduction procedure. The surgeon initially attempted a closed reduction, but this required imaging to check SC alignment. The patient was transferred to an adjacent hybrid operating theatre for imaging. Cone beam computed tomography (CBCT) was performed, which successfully demonstrated a significant reduction in the dislocation of the SC joint. The trachea and brachiocephalic artery were no longer compressed or displaced. This case study demonstrates an alternative to the patient being transferred to the medical imaging department for multi-slice CT. It also describes a novel use of the hybrid operating theatre and its CBCT capabilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern sensitivity analysis - 15651

Sensitivity analysis has been applied to complex models, such as performance assessment models, since at least the advent of computational tools to support such an approach to model evaluation. Initially, sensitivity analysis methods were applied to deterministic models and focused on changing one input variable at a time. Probabilistic modeling opened the door to evaluating changes in all input variables simultaneously. Standardized rank regression methods were primarily used in the last century to evaluate probabilistic models. These methods assume linearity in the rank response of the model to the inputs. At the very least this assumes monotonicity in the response, but for the most part the response needs to be near-linear. This is highly unlikely for performance assessment models that are based on differential equations, multiplication and division of variables that are usually not correlated, and conservatism that is not well understood. There are better statistical methods for evaluating highly non-linear and dynamic probabilistic models. Some of these methods were founded in the data mining industry. This century has seen a rapid development of the internet that led directly to the development of data mining techniques for massive databases. Although the goals were different, these techniques can be adapted to sensitivity analysis for complex probabilistic models, which, also, form large, or even massive, databases. These modern sensitivity analysis procedures assess the importance of every explanatory variable (input parameters) used in a probabilistic model. In practice, this means that for each endpoint of interest, every explanatory variable in the model is associated with a quantitative measure of importance. For a given explanatory variable, the importance value depends on the endpoint of interest. This global approach to sensitivity analysis allows all levels of interactions to be evaluated, so that the variation in the output can be measured at every level of possible interaction. The effects are collected together during sensitivity analysis processing, and then separated out to attribute the overall contribution of each input parameter to the model output. These global sensitivity analysis procedures have the ability to characterize non-linear and non-monotonic relationships between explanatory variables and endpoints of interest. This is critically important because of the need to characterize complex interactions among multiple explanatory variables in PA models that often have non-linear and non-monotonic effects. The options for sensitivity analysis are fully explored, including an evaluation of several methods when applying them to a well-known complex non-linear non-monotonic model. The results clearly demonstrate the relative benefit of using data mining methods over simple statistical approaches such as standardized rank regression. (authors)

97 MATHEMATICS AND COMPUTING↗

Incidence and Consequence of Nontarget Embolization Following Bland Hepatic Arterial Embolization

Purpose: Estimate the incidence of nontarget embolization (NTE) as identified on immediate post-hepatic artery embolization CT. Materials and Methods: Two hundred hepatic embolizations performed with particles alone (bland embolization) in 147 patients between August 16, 2013 and August 26, 2014 with immediate post-procedure CT were retrospectively reviewed. Arterial anatomy, vessels treated, imaging findings of NTE, patient demographics, length of hospital stay following embolization, and procedure-related complications were recorded. The data were analyzed using two-sided t-tests and chi-squared tests. Results: Evidence of NTE was seen on post-procedure CT in 64 of 200 cases (64/200, 32%). Six organs were affected, with 69 discrete sites in 64 patients. The majority (49/69, 71.0%) involved the gallbladder. The mean length of hospital stay (LOS) for patients with and without NTE was 2.9 ± 1.5 nights (range 1–7) and 2.9 ± 2.3 nights (range 0–21), respectively (P = 0.81). NTE was more common following embolization of replaced or accessory hepatic vessels. There were three complications in the NTE group (3/64, 4.7%) following the embolization procedure, one of which was cholecystitis directly related to NTE. The other two were one incidence each of contrast-induced nephropathy and pneumonia. In the group without NTE, seven complications occurred (7/136, 5.1%, P = 0.889), including one death resulting from hepatic failure, two gastrointestinal bleeds, two hepatic abscesses, flash pulmonary edema, and pancreatitis. Conclusion: Unanticipated NTE is not uncommon after bland hepatic artery embolization, particularly after treating accessory or replaced vessels, but does not increase complications or LOS. Level of Evidence: Level 2b, Retrospective Cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized mirror shape tuning using beam weightings based on distance, angle of incidence, reflectivity, and power

For glancing-incidence optical systems, such as short-wavelength optics used for nano-focusing, incorporating physical factors in the calculations used for shape optimization can improve performance. Wavefront metrology, including the measurement of a mirror's shape or slope, is routinely used as input for mirror figure optimization on mirrors that can be bent, actuated, positioned, or aligned. Modeling shows that when the incident power distribution, distance from focus, angle of incidence, and the spatially varying reflectivity are included in the optimization, higher Strehl ratios can be achieved. Following the works of Maréchal and Mahajan, optimization of the Strehl ratio (for peak intensity with a coherently illuminated system) occurs when the expectation value of the phase error's variance is minimized. We describe an optimization procedure based on regression analysis that incorporates these physical parameters. This approach is suitable for coherently illuminated systems of nearly diffraction-limited quality. Mathematically, this work is an enhancement of the methods commonly applied for ex situ alignment based on uniform weighting of all points on the surface (or a sub-region of the surface). It follows a similar approach to the optimization of apodized and non-uniformly illuminated optical systems. Significantly, it reaches a different conclusion than a more recent approach based on minimization of focal plane ray errors.

47 OTHER INSTRUMENTATION↗

TU-AB-303-03: CBCT-Based On-Site Simulation, Planning, and Delivery (OSPD) for Whole Brain Radiotherapy

Purpose: To demonstrate the feasibility of a CBCT-based on-site simulation, planning, and delivery (OSPD) for whole brain radiotherapy, in which all steps from imaging, planning to treatment delivery are performed at the treatment unit in one appointment time slot. This work serves as the proof of concept for future OSPD single fraction radiation therapy. Methods: An integrated on-site imaging, planning and delivery workflow was developed and tested for whole brain radiotherapy. An automated two-opposed-oblique-beam plan is created by utilizing the treatment planning system scripting and simple field-in-field IMRT. The IMRT plan is designed with maximum 8 control points to cover the target volume consisting of the brain to C1/C2 of the spinal cord, with dose homogeneity criteria from −5% to +7% of the prescription dose. Due to inaccuracy of reconstructed Hounsfield unit numbers in CBCT images, the dose distribution is calculated with non-heterogeneity correction introducing only clinically insignificant dose discrepancy. A coherent and synchronized workflow was designed for a team of attending physician, physicist, therapists, and dosimetrist to work closely with the ability to quickly modify, approve, and implement the treatment. Results: Thirty-one patients have been treated with this OSPD treatment, without compromising the plan quality compared to our regular clinically used parallel apposed 2D plans. The average time for these procedures are 48.02 ±11.55 minutes from the time patient entered the treatment room until s/he exited, and 35.09 ±10.35 minutes from starting CBCT until last beam delivered. This time duration is comparable to the net time when individual tasks are summed up during our regular CT- based whole brain planning and delivery. Conclusions: The OSPD whole brain treatment has been tested to be clinically feasible. The next step is to further improve the efficiency and to streamline the workflow. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗

Energy and momentum preserving Coulomb collision model for kinetic Monte Carlo simulations of plasma steady states in toroidal fusion devices

A kinetic Monte Carlo model suited for self-consistent transport studies is proposed and tested. The Monte Carlo collision operator is based on a widely used model of Coulomb scattering by a drifting Maxwellian and a new algorithm enforcing the momentum and energy conservation laws. The difference to other approaches consists in a specific procedure of calculating the background Maxwellian parameters, which does not require ensemble averaging and, therefore, allows for the use of single-particle algorithms. This possibility is useful in transport balance (steady state) problems with a phenomenological diffusive ansatz for the turbulent transport, because it allows a direct use of variance reduction methods well suited for single particle algorithms. In addition, a method for the self-consistent calculation of the electric field is discussed. Results of testing of the new collision operator using a set of 1D examples, and preliminary results of 2D modelling in realistic tokamak geometry, are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Connecting CO intensity mapping to molecular gas and star formation in the epoch of galaxy assembly

Intensity mapping, which images a single spectral line from unresolved galaxies across cosmological volumes, is a promising technique for probing the early universe. Here we present predictions for the intensity map and power spectrum of the CO(1–0) line from galaxies at z∼2.4–2.8, based on a parameterized model for the galaxy–halo connection, and demonstrate the extent to which properties of high-redshift galaxies can be directly inferred from such observations. We find that our fiducial prediction should be detectable by a realistic experiment. Motivated by significant modeling uncertainties, we demonstrate the effect on the power spectrum of varying each parameter in our model. Using simulated observations, we infer constraints on our model parameter space with an MCMC procedure, and show corresponding constraints on the L{sub IR}–L{sub CO} relation and the CO luminosity function. These constraints would be complementary to current high-redshift galaxy observations, which can detect the brightest galaxies but not complete samples from the faint end of the luminosity function. By probing these populations in aggregate, CO intensity mapping could be a valuable tool for probing molecular gas and its relation to star formation in high-redshift galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Percutaneous Biopsy and Radiofrequency Ablation of Osteoid Osteoma with Excess Reactive New Bone Formation and Cortical Thickening Using a Battery-Powered Drill for Access: A Technical Note

PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drilling including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transition core modeling for extended enrichment, accident tolerant fuel using PARCS/Polaris

Current plans and efforts from reactor operators and vendors to include extended enrichment (EE) and accident-tolerant fuel (ATF) in current reactor fleets motivate the study of these changes in reactor physics analysis. This work uses the US Nuclear Regulatory Commission core simulator PARCS to do the core calculation and SCALE Polaris lattice physics code to generate the required homogenized, few-group constants. The lattice model used is based on the GE-14 10x10 assemblies with UO{sub 2} fuels. Both nominal core and transition core are studied in this work, and both cores use GE-14 10x10 assemblies with UO{sub 2} fuel. The nominal core uses regular UO{sub 2} fuel with a maximum enrichment of 5 wt % and ZIRC-2 cladding. The ATF transition core uses FeCrAl cladding and regular UO{sub 2} fuel, while the EE-ATF transition core uses FeCrAl cladding with UO{sub 2} fuel with 8 max wt % enrichment. The accuracy presented in the colorset models verified the capability of the PARCS/Polaris procedures for the transition core analysis. For the whole core calculation, the ATF and EE-ATF transition core models were made in addition to the nominal core model. The core parameters to study are the core power distribution and power peaking factor, doppler temperature coefficients, and control rod worth at cold zero power and hot full power. Comparing the core parameters of the transition cores with the nominal core in PARCS, the results suggest that there is no unexpected outcome for the implementation of ATF and EE fuels. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gas-kinetic unified algorithm for hypersonic flows covering various flow regimes solving Boltzmann model equation in nonequilibrium effect

Based on the Gas-Kinetic Unified Algorithm (GKUA) directly solving the Boltzmann model equation, the effect of rotational non-equilibrium is investigated recurring to the kinetic Rykov model with relaxation property of rotational degrees of freedom. The spin movement of diatomic molecule is described by moment of inertia, and the conservation of total angle momentum is taken as a new Boltzmann collision invariant. The molecular velocity distribution function is integrated by the weight factor on the internal energy, and the closed system of two kinetic controlling equations is obtained with inelastic and elastic collisions. The optimization selection technique of discrete velocity ordinate points and numerical quadrature rules for macroscopic flow variables with dynamic updating evolvement are developed to simulate hypersonic flows, and the gas-kinetic numerical scheme is constructed to capture the time evolution of the discretized velocity distribution functions. The gas-kinetic boundary conditions in thermodynamic non-equilibrium and numerical procedures are studied and implemented by directly acting on the velocity distribution function, and then the unified algorithm of Boltzmann model equation involving non-equilibrium effect is presented for the whole range of flow regimes. The hypersonic flows involving non-equilibrium effect are numerically simulated including the inner flows of shock wave structures in nitrogen with different Mach numbers of 1.5-Ma-25, the planar ramp flow with the whole range of Knudsen numbers of 0.0009-Kn-10 and the three-dimensional re-entering flows around tine double-cone body.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel Radiometry for In-Pipe Robotic Inspection of Holdup Deposits in Gaseous Diffusion Piping - 19503

This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pediatric Percutaneous Osteoid Osteoma Ablation: Cone-Beam CT with Fluoroscopic Overlay Versus Conventional CT Guidance

PurposeTo compare technical success, clinical success, complications, radiation dose, and total room utilization time for osteoid osteoma thermal (radiofrequency or microwave) ablation using cone-beam computed tomography (CBCT) with two-axis fluoroscopic navigational overlay versus conventional computed tomography (CT) guidance.Materials and MethodsA retrospective review was performed to identify all osteoid osteoma ablations performed over a 5.5-year period at a single tertiary care pediatric hospital. Twenty-five ablations (15 radiofrequency and 10 microwave) in 23 patients undergoing fluoroscopic CBCT-guided osteoid osteoma ablation were compared to 35 ablations (35 radiofrequency) in 32 patients undergoing ablation via conventional CT guidance. Dose area product and dose length product were recorded for CBCT and conventional CT, respectively, and converted to effective doses. Technical success, clinical success (cessation of pain and medication use 1 month after ablation), complications, radiation dose, and total room utilization time were compared.ResultsAll procedures were technically successful. Twenty-two of 25 (88.0%) CBCT and 31 of 35 (88.6%) conventional CT-guided ablations achieved immediate clinical success. There were two minor complications in each group and no major complications. Mean effective radiation dose was significantly lower for CBCT compared to CT guidance (0.12 vs. 0.39 mSv, p = 0.02). Mean total room utilization time for CBCT was longer (133.5 vs. 97.5 min, p = 0.0001).ConclusionsFluoroscopic CBCT guidance for percutaneous osteoid osteoma ablation yields similar technical and clinical success, reduced radiation dose, and increased total room utilization time compared to conventional CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Serious Neurological Complication Resulting from Inadvertent Intradiscal Injection During Fluoroscopically Guided Interlaminar Epidural Steroid Injection

We describe the case of a 30-year-old patient who was referred for lumbar epidural corticosteroid injection due to right L5 radiculopathy. Two months earlier, MRI demonstrated a right large paracentral L4–L5 disk extrusion causing disabling L5 radiculopathy. The L4–L5 level was selected for interlaminar injection, using fluoroscopic guidance. During injection, the patient developed severe pain in both lower extremities. Thus, the procedure was immediately terminated. Paraplegia occurred within several minutes. Urgent lumbar spine CT and MRI demonstrated contrast material in a massive extruded disk fragment and substantial increase in size of the disk extrusion compared to pre-injection MRI. Emergency surgery was performed for lumbar decompression and discectomy. Although rare, serious neurological complication can result from inadvertent intradiscal injection of contrast material during lumbar epidural injection. This case illustrates the importance of recognizing the possibility of dynamic change in the size of an extruded disk fragment when the MRI precedes injection by a substantial time interval. Level of Evidence: IV, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Measurement of Scatter to Primary Ratio by Localized Primary Modulation in Industrial Computed Radiography

The scatter-to-primary ratio (SPR), can serve as an important parameter for performing the scatter correction procedures or build up factor determination in radiography projections. In this work an experimental technique is presented based on localized primary modulation for direct SPR measurement. As illustrative examples, the SPR is measured for steel and aluminum step wedges to demonstrate the applicability of the presented technique in computed radiography. As a required parameter, the effective transmission factor of the modulator is measured using primary beam stopping concept over a calibration block. This technique has significant advantages such as a straight forward theory, simplified applicability in industrial site conditions, beam hardening consideration as well as automation possibility. The technique works by a single image acquisition, without image data loss in the interested area.

42 ENGINEERING↗

Poster — Thur Eve — 61: A new framework for MPERT plan optimization using MC-DAO

This work combines the inverse planning technique known as Direct Aperture Optimization (DAO) with Intensity Modulated Radiation Therapy (IMRT) and combined electron and photon therapy plans. In particular, determining conditions under which Modulated Photon/Electron Radiation Therapy (MPERT) produces better dose conformality and sparing of organs at risk than traditional IMRT plans is central to the project. Presented here are the materials and methods used to generate and manipulate the DAO procedure. Included is the introduction of a powerful Java-based toolkit, the Aperture-based Monte Carlo (MC) MPERT Optimizer (AMMO), that serves as a framework for optimization and provides streamlined access to underlying particle transport packages. Comparison of the toolkit's dose calculations to those produced by the Eclipse TPS and the demonstration of a preliminary optimization are presented as first benchmarks. Excellent agreement is illustrated between the Eclipse TPS and AMMO for a 6MV photon field. The results of a simple optimization shows the functioning of the optimization framework, while significant research remains to characterize appropriate constraints.

60 APPLIED LIFE SCIENCES↗