Search NASA⌕ Search

SEARCH · Search NASA

Results for “conduction cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Heterogeneous Integration Technologies for High-temperature, High-density, Low-profile Power Modules of Wide Bandgap Devices in Electric Drive Applications (Final Technical Report)

The goal of this project is to develop packaging technologies for making high-temperature, high-density, and low-profile wide-bandgap (WBG) power electronics modules for electric drives. These modules are aimed at enabling the DOE’s University Consortium to reach its 2025 inverter targets of ≥ 100 kW/L and ≤ 2.7 $/kW. The specific objectives are to: design and fabricate SiC half-bridge power modules with double-sided cooling and parasitic inductances < 5 nH, heat flux density > 400 W/cm 2 , and working junction temperature of 200 o C; design, fabricate, and deliver a gate driver with double-sided cooled modules for the construction of a 100 kW/L inverter at Oak Ridge National Lab; and design and prototype intelligent gate drivers with integrated current sensor and a low-profile DC-DC power supply with air-core transformer for testing power modules at 200 o C junction temperature. We followed an iterative technical approach of design, simulation, fabrication, and testing of various versions of modules, current sensors, and power supply. The state-of-the-art silicon carbide devices rated at 1.2 kV and 149 A were packaged by sintered-silver bonding on an aluminum nitride direct-bond-copper substrate for high thermal conductivity, high working temperature, and high joint reliability. Porous silver posts were used to interconnect the device’s source pads to the other direct-bond-copper substrate for low mechanical stresses, ease of manufacturing, and double-sided cooling. A current sensor based on package parasitic inductance was developed to measure switching current. A dynamic feedback scheme was developed to compensate the effect of parasitic resistance and temperature variation. A constant-current class-E dc-dc converter with air-core transformer was developed. Air-core transformer was used due to the unavailability of magnetic core at high temperatures. Gate driver and power supply were integrated with the double-side cooled, high temperature SiC power modules for testing the modules at 200 o C junction temperature. Double-pulse and continuous testing of the integrated technologies validated the design and fabrication of the three component technologies. Throughout the project, we overcame the challenge for design verification caused by low prototyping yield, which then helped train the graduate students, the future workforce, to learn the engineering know-how for low-cost manufacturing of reliable products. Below is a summary of the major accomplishments of this project: development of a prototyping process for fabricating double-side cooled (1200 V, 149 A) SiC phase-leg modules capable of working to 200 o C Tj; simulation and experimental verification of the improvement of thermo-mechanical reliability of the double-side cooled SiC phase-leg module by using rigid encapsulant; design and experimental validation of a current sensor based on package parasitic inductance and a compensation solution for eliminating the effect of parasitic resistance; design and experimental validation of a low-profile power supply with six-output air-core transformer for gate driver; functional demonstration of a SiC phase-leg module integrated with its gate driver, current sensor, and an air-core power supply at 200 o C Tj in a double-pulse switching test setup and Buck converter continuous test setup; successful completion of six PhD and two MS students who are or will work at Apple Inc., Tesla Inc., Wolfspeed Inc., Microchip Inc., Monolithic Power Systems Inc., and LG Magna Inc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structural, magnetic, optical, dielectric and electronic properties of R 2 NiIrO 6 (R = Pr and Nd): A comprehensive experimental and theoretical investigation

Double perovskites are highly promising materials capable of exhibiting a wide variety of phenomena. In this work, we perform a comprehensive experimental and theoretical study of polycrystalline R 2 NiIrO 6 (R = Pr and Nd) compounds. Both compounds were synthesised using the solid-state reaction method. Rietveld refinement confirmed a monoclinic structure with the P2 1 /n space group for both compounds. The scanning electron images showed the average grain sizes of 0.55 μm for R = Pr and 0.46 μm for R = Nd. Fourier transform infrared ra- diation spectra of the two compounds presented two intense bands at 470 cm -1 and 540 cm -1 . The optical measurements revealed that the band gaps of the compounds were in the visible absorption range. The field- cooled magnetisation - field hysteresis measurements indicated exchange bias properties in the synthesised compounds at low temperatures. Both temperature and frequency variation of dielectric constant and loss tangent measurements were conducted. The frequency-dependent ac conductivity measurements indicated that the conductivity increases with the increase of frequency as well as temperature. The Nd 2 NiIrO 6 compound showed lower ac conductivities compared to its isostructural Pr 2 NiIrO 6 compound. The atomic and electronic structures of Nd 2 NiIrO 6 and Pr 2 NiIrO 6 were explored using the spin-polarised calculations performed within the DFT+U method. Our results suggested that the inclusion of on-site correlations and repulsions for the d-states of atoms was necessary in order to obtain finite band gaps of Nd 2 NiIrO 6 and Pr 2 NiIrO 6 systems.

36 MATERIALS SCIENCE↗

Development and demonstration of a BISON–Griffin modeling framework for the design of targeted TRISO transient experiments in the Transient Reactor Test Facility

Uranium oxycarbide (UCO)-bearing tri-structural isotropic (TRISO) particle fuels are expected to be used in numerous U.S. commercial reactor applications within the next decade. Here, in this work, we reviewed historical particle fuel transient experiments to identify gaps in TRISO fuel performance transient testing. A BISON–Griffin modeling framework was then developed to conduct preliminary TRISO transient analyses and begin to address these gaps. The framework was demonstrated using limiting-case transient conditions from a prototypic high-temperature gas-cooled reactor (HTGR). It was then applied to develop a matrix of experiments that could be performed in the Transient Reactor Test Facility (TREAT) to (1) evaluate UCO-fueled particle performance at moderate and high heat rates, (2) assess whether historical testing involving UO 2 -fueled particles is applicable to modern UCO-fueled particles, (3) deconvolute the impacts of temperature and heat rate on particle transient response, and (4) collect the data needed for fuel performance model validation and/or further development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Technical Report

MEST has developed Materials Navigator, a machine-learning software tool, to extract/combine data from disparate sources of materials information, which can be used to make suggestions for new directions of search and discovery of materials. The goal is to create a flexible software which can help materials science researchers quickly focus on a small group of promising materials and conduct fewer and less expensive experiments for maximum impact. Materials domains of interest for the Materials Navigator include solid state electrolytes for batteries, materials for fuel cells, photovoltaics, caloric cooling materials, and permanent magnets. Our solution is useful to materials researchers in academics and industry. To date, the MEST team has already developed a prototype of the Materials Navigator, which can be used to visualize a large number of materials compounds in their “descriptor space” where materials properties are encoded in machine learning based quantities. We have used Materials Navigator to make a list of potential new materials for batteries. It has also led to the experimental discovery of a new tantalum oxide superconductor.

36 MATERIALS SCIENCE↗

Pre-Test Feasibility Study Of Reactivity Transient Testing On TRISO Fuel In The TREAT Reactor

Uranium oxycarbide (UCO)-bearing tri-structural isotropic (TRISO) particle fuels are expected to be used in numerous US commercial reactor applications within the next decade. In this work, we reviewed historical particle fuel transient experiments to identify gaps in the TRISO fuel performance transient testing. A BISON--Griffin modeling framework was then developed to conduct preliminary TRISO transient analyses and begin to address these gaps. The framework was demonstrated using limiting-case transient conditions from a prototypic high-temperature gas-cooled reactor. It was then applied to develop a matrix of experiments that could be performed in the Transient Reactor Test Facility (TREAT) to (1) evaluate UCO-fueled particle performance at moderate and high heat rates, (2) assess whether historical testing involving UO$_2$-fueled particles is applicable to modern UCO-fueled particles, (3) deconvolute the impacts of temperature and heat rate on particle transient response, and (4) collect the data needed for fuel performance model validation and/or further development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Capabilities for High-Temperature Gas-Cooled Reactor Analysis

RELAP5-3D is the premier systems thermal-hydraulic code in the world. The code has been used significantly for high-temperature gas-cooled reactor (HTGR) analyses over the last 10 years, but there has not been a comprehensive summary of RELAP5-3D capabilities and methods for HTGR modeling. In this paper, we provide a guide for how novice users can build models for prismatic HTGRs. This guide includes best practices for developing heat structures and setting up radiation and conduction heat transfer. We also provide a summary of relevant validation studies. These studies are divided into three categories: separate effects tests, integral effects tests, and nuclear reactor studies. We present a comprehensive review of RELAP5-3D HTGR applications for reactor modeling over the last 10 years. These applications include work for the Modular High-Temperature Gas-Cooled Reactor benchmark, design activities for a prismatic HTGR as part of the U.S. Department of Energy’s Advanced Demonstration and Test Reactor Options Study, and studies performed to design gas-cooled microreactors. Following the comprehensive literature review, we present a gap analysis highlighting capabilities of RELAP5-3D that are available and missing for a complete analysis of HTGR thermal hydraulics. We also discuss the limitations of existing code capabilities and potential improvements that could improve analyses. Current research efforts have yet to fully validate RELAP5-3D for a prismatic HTGR analysis; however, some of this is attributable to confounding factors in the available experimental data as opposed to code capabilities. In conclusion, this paper presents the most comprehensive review to date on RELAP5-3D capabilities, limitations, and applications for HTGR analysis.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

POST-TEST EXAMINATIONS OF A LOCA SAMPLE FROM AN IRRADIATED HIGH-BURNUP PWR M5 FUEL ROD

A LOCA integral test with high burnup PWR M5 fuel rod was conducted in the Irradiated Fuel Examination Laboratory through the complete LOCA sequence: heating the LOCA sample to 300ºC and pressurizing the internal pressure to 8.27 MPa, heating at 5ºC/s from 300 to 1200ºC, holding in steam for 90s at 1200ºC, cooling at 3ºC/s to 800ºC, followed by water quench and rapid cooling to 100ºC. After LOCA testing, examinations, such as the fuel fragmentation analysis, burst and ballooning characterization, axial strain measurement, and microstructural examinations were performed. Metallographic examinations of an as-irradiated high burnup sample adjacent to the LOCA test sample revealed a bonding layer between the fuel and cladding. The posttest LOCA examinations indicates the corrosion layer formed during normal operations in the commercial reactor might provide a protection against the steam oxidation at high temperatures for test times performed in this work. The microstructure of the as-irradiated fuel is compared to the microstructure of the post-LOCA test fuel. Posttest LOCA examination on unirradiated post-tests Zr cladding samples was conducted, which served as baseline data for in cell testing with irradiated samples. The results obtained with irradiated PWR high burnup M5 fuel rad were compared to the LOCA test data obtained with irradiated BWR high burnup Zircaloy-2 fuel rod at Argonne national Laboratory.

Yan, Yong↗

Evolution and feedback of AGN jets of different cosmic ray composition

Jet feedback from active galactic nuclei (AGN) is one of the most promising mechanisms for suppressing cooling flows in cool-core clusters. However, the composition of AGN jets and bubbles remains uncertain; they could be thermally dominated, or dominated by cosmic ray proton (CRp), cosmic ray electron (CRe), or magnetic energy. In this work, we investigate the evolution and feedback effects of CRp and CRe dominated jets by conducting 3D magnetohydrodynamic simulations of AGN jet-inflated bubbles in the intracluster medium using the FLASH code. We present the evolution of their energies, dynamics, and heating, and model their expected cavity-power versus radio-luminosity relation (P cav –L R ). We find that bubbles inflated by CRe dominated jets follow a very similar dynamical evolution to CRp dominated bubbles even though CRe within bubbles suffer significantly stronger synchrotron and inverse-Compton cooling. This is because, as CRe lose their energy, the jet-inflated bubbles quickly become thermally dominated within ∼30 Myr. Their total energy stops decreasing with CR energy and evolves similarly to CRp dominated bubbles. The ability of CRe and CRp dominated bubbles to heat the intracluster medium is also comparable; the cold gas formed via local thermal instabilities is well suppressed in both cases. The CRp and CRe bubbles follow different evolutionary trajectories on the P cav –L R plane, but the values are broadly consistent with observed ranges for FR-I sources. We also discuss observational techniques that have potential for constraining the composition of AGN jets and bubbles.

79 ASTRONOMY AND ASTROPHYSICS↗

Oxidation of 3D-printed SiC in air and steam environments

Here, the high-temperature oxidation of additively manufactured and chemically vapor infiltrated (3D-printed SiC) has been compared to chemical vapor deposited (CVD) SiC. 100-h isothermal exposures were conducted at 1425° and 1300°C at 1 atm under both dry air and steam environments. A SiC reaction tube was utilized to reduce silica volatility. After steam oxidation at 1425° and 1300°C, on the 3D-printed SiC surface, which was intrinsically rougher than the CVD surface, scales were 70%–90% thicker at the convex regions compared to concave/flat regions. In the convex regions, large cracks perpendicular to the oxidizing interface were observed. After dry air oxidation, scale thicknesses were comparable between 3D-printed SiC and CVD SiC, regardless of geometry. Finite element modeling, conducted to elucidate the relationship between SiC geometry and ß- to α-cristobalite transformation stress, determined cristobalite transformation tensile stresses to be on the order of 103 MPa during cool down, assuming a 6 vol% reduction. Compared to flat SiC substrates, tensile transformation stresses were elevated at concave regions and relaxed at convex regions. Combined with specimen mass gain (accounting for the rougher surface) of 3D-printed SiC being 15%–32% higher for 3D-printed SiC after 1300°C and 1425°C steam oxidation, the work presented concludes that the increased oxidation of 3D-printed SiC is primarily caused by tensile hoop stresses driven by oxidation volume expansion. Lastly, the efficacy of the 3D-printing method is demonstrated through the production of tristructural isotropic imbedded 3D-printed SiC fuel forms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Optimization of a Gas-Cooled, Airfoil Fin Microchannel Heat Exchanger

High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, was analyzed and optimized using a design of experiments with artificial intelligence and machine learning techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin PCHEs has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure was developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. STAR-CCM+ was used to analyze a simplified two-channel configuration where five parameters were varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods were compared for generating surrogate models – a 5D polynomial and a regression neural network. A response surface approximation was created from the surrogate models and input to a genetic algorithm. The genetic algorithm identified a set of optimal points on the Pareto front. The optimal geometry was found across six channel Reynolds numbers ranging from 1000 to 5000 to analyze how varying inlet conditions affects the optimal design. A set of optimal designs that maximizes heat transfer and minimizes pressure drop was identified, and a thermal stress analysis was performed on the optimal design. This work has developed a digital framework for the expedient topology design and evaluation of PCHE designs for gas-cooled microreactor applications. Correlations for the Nusselt number and Darcy friction factor were developed that can be useful for thermal hydraulic analyses using system codes. A thermal stress analysis was conducted and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.

42 ENGINEERING↗

Differences in urban plant community compositions across an urban-rural gradient in Knoxville, TN

Urban forests, or vegetation in areas under heavy human influence, provide many ecosystem services to urban residents such as localized cooling via evapotranspiration, shade, filtering of air pollution, and the associated health benefits of natural spaces. In order to quantify the magnitude of localized cooling by trees growing in varying levels of urbanization (based on % impervious surfaces, e.g., buildings, pavement), urban forest species composition, tree size, and tree density must be characterized. As a part of Oak Ridge National Laboratory’s (ORNL) urban forest temperature study, we conducted tree censuses in five Knoxville city parks where ORNL meteorological stations are deployed. Moreover, we measured every woody plant ≥ 5 cm diameter at breast height (DBH) within a 50 m radius of each site’s meteorological station for its DBH and species identification. When possible, individuals were identified down to species. Certain genera (Quercus spp., Carya spp., Pinus spp.) were identified down to genera in interest of time. Individual and total site basal area were calculated from measured DBH data. Results show notable differences in urban plant community compositions and total woody plant basal area across sites, with more urban sites closer to downtown (West View and SEEED) having lower tree basal area than the more suburban sites (West Hills, Cumberland Estates, and Victor Ashe). We identified 54 species across all sites, with West Hills and Victor Ashe having the highest species diversity. Our results show differences in forest compositions and sizes across Knoxville, which are currently informing ORNL’s evapotranspiration estimates for each site. Data Summary: Census data for West Hills (WH), Cumberland Estates (CE), Victor Ashe (VA), West View (WV), and Socially Equal Energy Efficient Development or SEEED (SD) urban forests in Knoxville, TN, USA, including tree size based on diameter at breast height (DBH; 1.3 m), species identification (Latin and common names), and basal area per stem (BA=π×[.5*DBH]^2). Field data are summarized in this file: “Community_Composition_Data.CSV”. Site-specific data detailing each site’s coordinates, number of stems measured at DBH, average tree DBH, α-diversity (number of species present), and total site basal area (sum of individual basal areas per site) are in this file: “Site_Comparisons.CSV”.

Warren, Jeffrey [ORNL] (ORCID:0000000206804697)↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemical interaction and compatibility of uranium mononitride and alumina forming austenitic stainless steel

Uranium mononitride (UN) and alumina forming austenitic (AFA) stainless steel are a potential fuel-cladding combination for the lead-cooled fast reactor (LFR). Chemical compatibility between UN and AFA steel needs to be verified before implementation in a nuclear reactor. Diffusion couple experiments at 823 K and 1023 K were conducted for nonirradiated UN samples in contact with as-cast (no thermally grown Al 2 O 3 ) and preoxidized (with thermally grown Al 2 O 3 ) AFA for 500 and 1000 h in an inert environment. Preoxidized AFA exhibited little to no interaction with all UN samples tested at both 823 K and 1023 K, displaying the stability and capability of the Al 2 O 3 layer to prevent chemical interaction and inter-diffusion with UN. Chemical interaction occurs between UN and as-cast AFA. At 1023 K, an aluminum and nitrogen rich phase (likely AlN) formed along the interface of as-cast AFA and UN samples. At 823 K the AlN phase was not prominently observed due to the reduced diffusivity of aluminum through AFA. The aluminum and nitrogen-enriched phase was also observed in a high temperature pressure-assisted test sample of UN and as-cast AFA thermally treated at 1373 K. Finally, in UN samples doped with a low weight percent of UO 2 (< 3 wt%), AlN was not detected along the interface at either temperatures, and an Al 2 O 3 layer likely formed along the interface and prevented further chemical interaction between UN and as-cast AFA.

36 MATERIALS SCIENCE↗

Synthesis and characterization of amorphous Fe2.75Dy-oxide thin films demonstrating room-temperature semiconductor, magnetism, and optical transparency

Recently, amorphous/disordered oxide thin films made from Fe and lanthanides like Dy and Tb have been reported to have a rich set of magnetic, optical, and electronic properties, as well as room-temperature magneto-electric coupling with multiferroics [A. Malasi et al., Sci. Rep. 5, 18157 (2015); H. Taz et al., Sci. Rep. 6, 27869 (2016); and H. Taz et al., Sci. Rep. 10, 1–10 (2020)]. Here, we report the synthesis and detailed characterization of Fe2.75Dy-oxide thin films prepared on various substrates using electron beam co-evaporation. The structure, chemistry, electric, magnetic, and optical properties were studied for the as-prepared and annealed (373 K, in air, 1 h) films of thickness 40 nm. High resolution transmission electron microscopy and electron diffraction study showed that the films were amorphous in both the as-prepared and annealed states. The electron energy-loss spectroscopy studies quantified that metal oxygen stoichiometry changed from Fe2.75Dy-O1.5 to Fe2.75Dy-O1.7 upon annealing. Synchrotron-based x-ray absorption spectroscopy investigation confirmed that the as-prepared films were highly disordered with predominantly metallic Fe and Dy states that became slightly oxidized with annealing in air. The as-prepared amorphous films demonstrated significantly high value of ordinary (∼10 cm2/V s) and anomalous (∼102 cm2/V s) Hall mobility and high electrical conductivity of ∼103 S/cm at room temperature. The cryogenic magnetic property measurement shows two-step magnetization below 200 K, suggesting exchange-spring magnetic interaction. The nature of the field cooled and zero-field cooled curves suggested a spin-glass like transition between 78 K and 80 K, with a characteristic broad peak. The Tauc plot analysis from optical transmission spectra confirms the existence of an optical bandgap of ∼2.42 eV that increased slightly to ∼2.48 eV upon annealing. This rich set of transport, optical, and magnetic properties in these thin films is very exciting and points to potential applicability in low-cost multifunctional devices requiring a combination of transparent, semiconducting, and magnetic responses, such as in spintronics.

Prasad Koirala, Krishna (ORCID:000000029137917X)↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗