Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Accelerating Thermochemical Equilibrium Calculations for Nuclear Reactor Applications

Thermochemical properties play a key role in modeling and simulation of several key phenomena in nuclear reactors. There has been an increasing interest in incorporating CALPHAD-based formulations in multiphysics simulations including for Molten Salt Reactors where knowledge of phase evolution of the salt and the chemical potentials of various elements are of utmost importance in source term analyses and redox control. However, the size of such simulations is often limited by the high computational cost of full thermodynamic equilibrium calculations. This work discusses the current efforts aimed at accelerating thermochemical equilibrium calculations for multiphysics simulations performed using the open-source finite element / finite volume code Multiphysics Object Oriented Simulation Environment (MOOSE) [1]. While several methods have been proposed for accelerating phase equilibrium calculations [2], most focus on relatively small systems and often rely on a- priori knowledge of the state-space of the system. Nuclear materials, however, are often multi-component systems owing to the evolution of composition under irradiation and an approach based on a-priori mapping of phase diagram is often not enough. This work is aimed at demonstrating an on-the-fly surrogate modeling framework that uses active learning to reduce the number of full equilibrium calculations that must be performed. By combining with efficient coupling approaches, the surrogate framework helps in reducing the computational cost of thermodynamic equilibrium informed multiphysics simulations of nuclear materials. The performance is benchmarked against full coupling with the thermochemistry library Thermochimica [3]. This work uses a machine learning based approach for constructing surrogate models to predict the stable phases in a multicomponent system. The surrogates were constructed using neural networks and Gaussian process classification. In this work, we compare the relative performance of the two methods. We also demonstrate the use of caching previous calculations by interpolating the values from nearest neighbors. References [1] Lindsay, A.D., et al. "2.0 – MOOSE: Enabling massively parallel multiphysics simulation", SoftwareX, 20 (2022): 101202. [2] Roos, W.A. and Zietsman J.H. "Accelerating complex chemical equilibrium calculations – A Review", Calphad, 77 (2022): 102380. [3] Piro, M.H.A., et al. "The thermochemistry library Thermochimica", Computational Materials Science, 67 (2013): 266-272.

36 MATERIALS SCIENCE↗

Comparing Cetane Number Measurement Methods

Cetane number is one of the most important fuel performance metrics for mixing controlled compression-ignition “diesel” engines, quantifying a fuel’s propensity for autoignition when injected into end-of-compression-type temperature and pressure conditions. The historical default and referee method on a Cooperative Fuel Research (CFR) engine configured with indirect fuel injection and variable compression ratio is cetane number (CN) rating. A subject fuel is evaluated against primary reference fuel blends, with heptamethylnonane defining a low-reactivity endpoint of CN = 15 and hexadecane defining a high-reactivity endpoint of CN = 100. While the CN scale covers the range from zero (0) to 100, typical testing is in the range of 30 to 65 CN. Alternatively, several constant-volume combustion chamber (CVCC)-based cetane rating devices have been developed to rate fuels with an equivalent derived cetane number (DCN) or indicated cetane number (ICN). These devices measure ignition delay for fuel injected into a fixed volume of high-temperature and high-pressure air to simulate end-of-compression-type conditions. In this study, a range of novel fuel compounds are evaluated across three CVCC methods: the Ignition Quality Tester (IQT), Fuel Ignition Tester (FIT), and Advanced Fuel Ignition Delay Analyzer (AFIDA). Resulting DCNs and ICNs are compared for fuels within the normal diesel fuel range of reactivity, as well as very high (~100) and very low DCNs/ICNs (~5). Distinct differences between results from various devices are discussed. This is important to consider because some new, high-efficiency advanced compression-ignition (CI) engine combustion strategies operate with more kinetically controlled distributed combustion as opposed to mixing controlled diffusion flames. These advanced combustion strategies may benefit from new fuel chemistries, but current rating methods of CN, DCN, and ICN may not fully describe their performance. In addition, recent evidence suggests ignition delay in modern on-road diesel engines with high-pressure common rail fuel injection systems may no longer directly correlate to traditional CN fuel ratings. Simulated end-of-compression conditions are compared for CN, DCN, and ICN and discussed in the context of modern diesel engines to provide additional insight. Results highlight the potential need for revised and/or multiple fuel test conditions to measure fuel performance for advanced CI strategies.

47 OTHER INSTRUMENTATION↗

Novel estimation of aerosol processes with particle size distribution measurements: a case study with the TOMAS algorithm v1.0.0

Atmospheric aerosol microphysical processes are a significant source of uncertainty in predicting climate change. Specifically, aerosol nucleation, emissions, and growth rates, which are simulated in chemical transport models to predict the particle size distribution, are not understood well. However, long-term size distribution measurements made at several ground-based sites across Europe implicitly contain information about the processes that created those size distributions. This work aims to extract that information by developing and applying an inverse technique to constrain aerosol emissions as well as nucleation and growth rates based on hourly size distribution measurements. We developed an inverse method based upon process control theory into an online estimation technique to scale aerosol nucleation, emissions, and growth so that the model–measurement bias in three measured aerosol properties exponentially decays. The properties, which are calculated from the measured and predicted size distributions, used to constrain aerosol nucleation, emission, and growth rates are the number of particles with a diameter between 3 and 6 nm, the number with a diameter greater than 10 nm, and the total dry volume of aerosol ( N 3–6 , N 10 , V dry ), respectively. In this paper, we focus on developing and applying the estimation methodology in a zero-dimensional “box” model as a proof of concept before applying it to a three-dimensional simulation in subsequent work. The methodology is first tested on a dataset of synthetic and perfect measurements that span diverse environments in which the true particle emissions, growth, and nucleation rates are known. The inverse technique accurately estimates the aerosol microphysical process rates with an average and maximum error of 2 % and 13 %, respectively. Next, we investigate the effect that measurement noise has on the estimated rates. The method is robust to typical instrument noise in the aerosol properties as there is a negligible increase in the bias of the estimated process rates. Finally, the methodology is applied to long-term datasets of in situ size distribution measurements in western Europe from May 2006 through June 2007. At Melpitz, Germany, and Hyytiälä, Finland, the average diurnal profiles of estimated 3 nm particle formation rates are reasonable, having peaks near noon local time with average peak values of 1 and 0.15 cm –3 s –1 , respectively. The normalized absolute error in estimated N 3–6 , N 10 , and V dry at three European measurement sites is less than 15 %, showing that the estimation framework developed here has potential to decrease model–measurement bias while constraining uncertain aerosol microphysical processes.

54 ENVIRONMENTAL SCIENCES↗

Local Control After Intensity-Modulated Radiotherapy for Head-and-Neck Rhabdomyosarcoma

Purpose: To examine the patterns of failure in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck rhabdomyosarcoma (RMS). Methods and Materials: Between 1998 and 2005, 19 patients with a diagnosis of head-and-neck RMS received IMRT at The Methodist Hospital. There were 11 male and 8 female patients, with a median age of 6 years at time of irradiation. Tumor location was parameningeal in 7, orbital in 6, and other head-and-neck RMS in 6. Chemotherapy was given to all patients, with vincristine, actinomycin D, and cyclophosphamide being the most common regimen (n = 18). The median prescribed dose was 5040 cGy. The clinical target volume included the gross tumor volume with a 1.5-cm margin. The median duration of follow-up for surviving patients was 56 months. Results: The 4-year overall survival and local control rates were 76% and 92.9%, respectively. One patient developed a local failure in the high-dose region of the radiation field; there were no marginal failures. Distant metastasis was seen in 4 patients. Overall survival was 42.9% for parameningeal sites and 100% for other sites (p < 0.01). Late toxicities were seen in 7 patients. Two secondary malignancies occurred in 1 child with embryonal RMS of the face and a p53 mutation. Conclusions: Local control was excellent in patients receiving IMRT for head-and-neck RMS. Patterns of local failure reveal no marginal failures in this group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

System and method for computed axial lithography (CAL) for 3D additive manufacturing

In one aspect the present disclosure relates to a system for forming a three dimensional (3D) object from a volume of photo-responsive material contained within a material container. A plurality of optical projection subsystems are adapted to be arranged circumferentially around a material container containing the volume of photo-responsive material, and are controlled by a controller. The optical projection subsystems direct optical projections at a plurality of angles θ through the volume of photo-responsive material. The optical projections are further directed about a z axis extending through the volume of photo-responsive material. The plurality of optical subsystems are further controlled by the controller to provide each of the optical projections with a calculated three-dimensional intensity distribution acting over a fixed temporal exposure period, which is sufficient to at least one of cure or remove selected portions of the volume of photo-responsive material, and leave other portions unmodified, to form a desired 3D part.

Kelly, Brett↗

Local Control and Toxicity in a Large Cohort of Central Lung Tumors Treated With Stereotactic Body Radiation Therapy

Purpose: Stereotactic body radiation therapy (SBRT) in central lung tumors has been associated with higher rates of severe toxicity. We sought to evaluate toxicity and local control in a large cohort and to identify predictive dosimetric parameters. Methods and Materials: We identified patients who received SBRT for central tumors according to either of 2 definitions. Local failure (LF) was estimated using a competing risks model, and multivariate analysis (MVA) was used to assess factors associated with LF. We reviewed patient toxicity and applied Cox proportional hazard analysis and log-rank tests to assess whether dose-volume metrics of normal structures correlated with pulmonary toxicity. Results: One hundred twenty-five patients received SBRT for non-small cell lung cancer (n=103) or metastatic lesions (n=22), using intensity modulated radiation therapy. The most common dose was 45 Gy in 5 fractions. Median follow-up was 17.4 months. Incidence of toxicity ≥ grade 3 was 8.0%, including 5.6% pulmonary toxicity. Sixteen patients (12.8%) experienced esophageal toxicity ≥ grade 2, including 50% of patients in whom PTV overlapped the esophagus. There were 2 treatment-related deaths. Among patients receiving biologically effective dose (BED) ≥80 Gy (n=108), 2-year LF was 21%. On MVA, gross tumor volume (GTV) was significantly associated with LF. None of the studied dose-volume metrics of the lungs, heart, proximal bronchial tree (PBT), or 2 cm expansion of the PBT (“no-fly-zone” [NFZ]) correlated with pulmonary toxicity ≥grade 2. There were no differences in pulmonary toxicity between central tumors located inside the NFZ and those outside the NFZ but with planning target volume (PTV) intersecting the mediastinum. Conclusions: Using moderate doses, SBRT for central lung tumors achieves acceptable local control with low rates of severe toxicity. Dosimetric analysis showed no significant correlation between dose to the lungs, heart, or NFZ and severe pulmonary toxicity. Esophageal toxicity may be an underappreciated risk, particularly when PTV overlaps the esophagus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

System and method for control of compression in internal combustion engine via compression ratio and elastic piston

The present disclosure relates to a system for controlling ignition of an air/fuel mixture intake charge directed into an internal combustion engine. The system may have a longitudinally movable inner cylinder liner configured to fit within a cylinder wall portion of an internal combustion engine, and able to receive a piston of the engine therein. A portion of the inner cylinder liner defines an internal volume forming a combustion chamber, and the internal volume controls a compression ratio of the cylinder. The system also has a cylinder head assembly operatively associated with the inner cylinder liner and able to move linearly to cause longitudinal displacement of the inner cylinder liner relative to the cylinder wall portion. This enables the volume of the combustion chamber to be further varied, to thus further vary the compression ratio.

Flowers, Daniel L.↗

Gemcitabine Chemotherapy and Single-Fraction Stereotactic Body Radiotherapy for Locally Advanced Pancreatic Cancer

Purpose: Fractionated radiotherapy and chemotherapy for locally advanced pancreatic cancer achieves only modest local control. This prospective trial evaluated the efficacy of a single fraction of 25 Gy stereotactic body radiotherapy (SBRT) delivered between Cycle 1 and 2 of gemcitabine chemotherapy. Methods and Materials: A total of 16 patients with locally advanced, nonmetastatic, pancreatic adenocarcinoma received gemcitabine with SBRT delivered 2 weeks after completion of the first cycle. Gemcitabine was resumed 2 weeks after SBRT and was continued until progression or dose-limiting toxicity. The gross tumor volume, with a 2-3-mm margin, was treated in a single 25-Gy fraction by Cyberknife. Patients were evaluated at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All 16 patients completed SBRT. A median of four cycles (range one to nine) of chemotherapy was delivered. Three patients (19%) developed local disease progression at 14, 16, and 21 months after SBRT. The median survival was 11.4 months, with 50% of patients alive at 1 year. Patients with normal carbohydrate antigen (CA)19-9 levels either at diagnosis or after Cyberknife SBRT had longer survival (p <0.01). Acute gastrointestinal toxicity was mild, with 2 cases of Grade 2 (13%) and 1 of Grade 3 (6%) toxicity. Late gastrointestinal toxicity was more common, with five ulcers (Grade 2), one duodenal stenosis (Grade 3), and one duodenal perforation (Grade 4). A trend toward increased duodenal volumes radiated was observed in those experiencing late effects (p = 0.13). Conclusion: SBRT with gemcitabine resulted in comparable survival to conventional chemoradiotherapy and good local control. However, the rate of duodenal ulcer development was significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological consequences of MLC calibration errors in IMRT delivery and QA

Purpose: The purpose of this work is threefold: (1) to explore biological consequences of the multileaf collimator (MLC) calibration errors in intensity modulated radiotherapy (IMRT) of prostate and head and neck cancers, (2) to determine levels of planning target volume (PTV) and normal tissue under- or overdose flagged with clinically used QA action limits, and (3) to provide biologically based input for MLC QA and IMRT QA action limits. Methods: Ten consecutive prostate IMRT cases and ten consecutive head and neck IMRT cases were used. Systematic MLC offsets (i.e., calibration error) were introduced for each control point of the plan separately for X1 and X2 leaf banks. Offsets were from - 2 to 2 mm with a 0.5 mm increment. The modified files were imported into the planning system for forward dose recalculation. The original plan served as the reference. The generalized equivalent uniform dose (gEUD) was used as the biological index for the targets, rectum, parotid glands, brainstem, and spinal cord. Each plan was recalculated on a CT scan of a 27 cm diameter cylindrical phantom with a contoured 0.6 cc ion chamber. Dose to ion chamber and 3D gamma analysis were compared to the reference plan. QA pass criteria: (1) at least 95% of voxels with a dose cutoff of 50% of maximum dose have to pass at 3 mm/3% and (2) dose to chamber within 2% of the reference dose. Results: For prostate cases, differences in PTV and rectum gEUD greater than 2% were identified. However, a larger proportion of plans leading to greater than 2% difference in prostate PTV gEUD passed the ion chamber QA but not 3D gamma QA. A similar trend was found for the rectum gEUD. For head and neck IMRT, the QA pass criteria flagged plans leading to greater than 4% differences in PTV gEUD and greater than 5% differences in the maximum dose to brainstem. If pass criteria were relaxed to 90% for gamma and 3% for ion chamber QA, plans leading to a 5% difference in PTV gEUD and a 5%-8% difference in brainstem maximum dose would likely pass IMRT QA. A larger proportion of head and neck plans with greater than 2% PTV gEUD difference passed 3D gamma QA compared to ion chamber QA. Conclusions: For low modulation plans, there is a better chance to catch MLC calibration errors with 3D gamma QA rather than ion chamber QA. Conversely, for high modulation plans, there is a better chance to catch MLC calibration errors with ion chamber QA rather than with 3D gamma QA. Ion chamber and 3D gamma analysis IMRT QA can detect greater than 2% change in gEUD for PTVs and critical structures for low modulation treatment plans. For high modulation treatment plans, ion chamber and 3D gamma analysis can detect greater than 2% change in gEUD for PTVs and a 5% change in critical structure gEUD since either QA methods passes the QA criteria. For gEUD changes less than those listed above, either QA method has the same proportion of passing rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

Salvage Treatment With Hypofractionated Radiotherapy in Patients With Recurrent Small Hepatocellular Carcinoma

Purpose: To investigate the rates of tumor response and local control in patients with recurrent small hepatocellular carcinoma (HCC) treated with hypofractionated radiotherapy (RT) as a salvage treatment and to evaluate treatment-related toxicities. Methods and Materials: Between 2006 and 2009, a total of 20 patients with recurrent small HCC were treated with hypofractionated RT after the failure of previous treatment. The eligibility criteria for hypofractionated RT were as follows: 1) HCC less than 5 cm, 2) HCC not adjacent to critical organs, 3) HCC without portal vein tumor thrombosis, and 4) less than 15% of normal liver volume that would be irradiated with 50% of prescribed dose. The RT dose was 50 Gy in 10 fractions. The tumor response was determined by CT scans performed 3 months after the end of RT. Results: The median follow-up period after RT was 22 months. The overall survival rates at 1 and 2 years were 100% and 87.9%, respectively. Complete response (CR) was achieved in seven of 20 lesions (35%) evaluated by CT scans performed 3 months after the end of RT. In-field local control was achieved in 85% of patients. Fourteen patients (70%) developed intra-hepatic metastases. Six patients developed grade 1 nausea or anorexia during RT, and two patients had progression of ascites after RT. There was no grade 3 or greater treatment-related toxicities. Conclusions: The current study showed a favorable outcome with respect to hypofractionated RT for small HCC. Partial liver irradiation with 50 Gy in 10 fractions is considered tolerable without severe complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases

Purpose: Resection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA). Methods: This is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded. Results: Twenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival. Conclusion: RFA is a safe and effective treatment for patients with small-volume sarcoma metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results for Trigeminal Schwannomas Treated With Gamma Knife Surgery

Purpose: Surgical resection is considered the desirable curative treatment for trigeminal schwannomas. However, complete resection without any complications remains challenging. During the last several decades, stereotactic radiosurgery (SRS) has emerged as a minimally invasive treatment modality. Information regarding long-term outcomes of SRS for patients harboring trigeminal schwannomas is limited because of the rarity of this tumor. The aim of this study was to evaluate long-term tumor control and functional outcomes in patients harboring trigeminal schwannomas treated with SRS, specifically with gamma knife surgery (GKS). Methods and Materials: Fifty-three patients harboring trigeminal schwannomas treated with GKS were evaluated. Of these, 2 patients (4%) had partial irradiation of the tumor, and 34 patients (64%) underwent GKS as the initial treatment. The median tumor volume was 6.0 cm{sup 3}. The median maximum and marginal doses were 28 Gy and 14 Gy, respectively. Results: The median follow-up period was 98 months. On the last follow-up image, 7 patients (13%) had tumor enlargement, including the 2 patients who had partial treatment. Excluding the 2 patients who had partial treatment, the actuarial 5- and 10-year progression-free survival (PFS) rates were 90% and 82%, respectively. Patients with tumors compressing the brainstem with deviation of the fourth ventricle had significantly lower PFS rates. If those patients with tumors compressing the brainstem with deviation of the fourth ventricle are excluded, the actuarial 5- and 10-year PFS rates increased to 95% and 90%, respectively. Ten percent of patients had worsened facial numbness or pain in spite of no tumor progression, indicating adverse radiation effect. Conclusions: GKS can be an acceptable alternative to surgical resection in patients with trigeminal schwannomas. However, large tumors that compress the brainstem with deviation of the fourth ventricle should be surgically removed first and then treated with GKS when necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

350 ps Ultrafast room-temperature scintillation realized on CsPbBr 3 -based single crystals via Br 2 over-doping

Ultrafast scintillators are essential for next-generation radiation detection, positron emission tomography, and high-speed medical imaging. All-inorganic CsPbBr 3 perovskites are attractive candidates because of their high stopping power, and excellent optical quality, yet their long carrier lifetimes result in slow scintillation responses on the order of hundreds of nanoseconds. Here, we demonstrate that controlled over-doping with Br 2 produces CsPbBr 3.03 single crystals with sub-nanosecond scintillation at room temperature while preserving crystal quality. Single crystals grown by the Bridgman method exhibit high transparency and maintain the orthorhombic perovskite structure. Br 2 over-doping induces a slight lattice expansion (about 0.42% increase in unit-cell volume) while maintaining the orthorhombic perovskite phase and high optical transparency. Optical absorption reveals a slight redshift of the absorption edge after Br 2 introduction, indicating a modified defect landscape. Time-resolved photoluminescence and radioluminescence measurements show that Br 2 doping creates dense and efficient recombination centers that reduce the scintillation decay time from more than 100 ns in undoped crystals to 350 ps under 5.486 MeV α-particle excitation, and the scintillation decay time decreases by two orders of magnitude. The doped crystals also achieve a spatial resolution of 12 lp mm −1 in X-ray imaging. These results reveal a defect-engineering route for achieving ultrafast scintillation in halide perovskites and highlight the potential of Br 2 -modified CsPbBr 3 for fast timing applications.

Li, Zongxiao [Chinese Academy of Sciences (CAS), N↗

Korea superconducting tokamak advanced research vacuum and gas puffing system

A piezoelectric valve, which has a flow rate of about 463 mbar l/s, has been installed to fuel the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. The valve flow rate is in situ calibrated by analyzing the pressure rise curve while fueling the vessel at a constant rate. The calibration method and results are presented. In addition to the flow rate, other vacuum system parameters, such as the pumping speed and the vessel volume, were experimentally obtained. Based on these measurements, a KSTAR vacuum system simulator was developed to calculate the valve drive signal to obtain a programmed pressure trace. An arbitrarily shaped pressure trace was successfully controlled in KSTAR with this hardware and software system.

36 MATERIALS SCIENCE↗

Optimizing Error-Bounded Lossy Compression for Scientific Data With Diverse Constraints

Vast volumes of data are produced by today's scientific simulations and advanced instruments. These data cannot be stored and transferred efficiently because of limited I/O bandwidth, network speed, and storage capacity. Error-bounded lossy compression can be an effective method for addressing these issues: not only can it significantly reduce data size, but it can also control the data distortion based on user-defined error bounds. In practice, many scientific applications have specific requirements or constraints for lossy compression, in order to guarantee that the reconstructed data are valid for post hoc analysis. For example, some datasets contain irrelevant data that should be isolated in particular and users often have intuition regarding value ranges, geospatial regions, and other data subsets that are crucial for subsequent analysis. Existing state-of-the-art error-bounded lossy compressors, however, do not consider these constraints during compression, resulting in inferior compression ratios with respect to user's post hoc analysis, due to the fact that the data itself provides little or no value for post hoc analysis. In this work we address this issue by proposing an optimized framework that can preserve diverse constraints during the error-bounded lossy compression, e.g., cleaning the irrelevant data, efficiently preserving different precision for multiple value intervals, and allowing users to set diverse precision over both regular and irregular regions. We perform our evaluation on a supercomputer with up to 2,100 cores. Experiments with six real-world applications show that our proposed diverse constraints based error-bounded lossy compressor can obtain a higher visual quality or data fidelity on reconstructed data with the same or even higher compression ratios compared with the traditional state-of-the-art compressor SZ. Furthermore, our experiments also demonstrate very good scalability in compression performance compared with the I/O throughput of the parallel file system.

97 MATHEMATICS AND COMPUTING↗

TU-AB-303-03: CBCT-Based On-Site Simulation, Planning, and Delivery (OSPD) for Whole Brain Radiotherapy

Purpose: To demonstrate the feasibility of a CBCT-based on-site simulation, planning, and delivery (OSPD) for whole brain radiotherapy, in which all steps from imaging, planning to treatment delivery are performed at the treatment unit in one appointment time slot. This work serves as the proof of concept for future OSPD single fraction radiation therapy. Methods: An integrated on-site imaging, planning and delivery workflow was developed and tested for whole brain radiotherapy. An automated two-opposed-oblique-beam plan is created by utilizing the treatment planning system scripting and simple field-in-field IMRT. The IMRT plan is designed with maximum 8 control points to cover the target volume consisting of the brain to C1/C2 of the spinal cord, with dose homogeneity criteria from −5% to +7% of the prescription dose. Due to inaccuracy of reconstructed Hounsfield unit numbers in CBCT images, the dose distribution is calculated with non-heterogeneity correction introducing only clinically insignificant dose discrepancy. A coherent and synchronized workflow was designed for a team of attending physician, physicist, therapists, and dosimetrist to work closely with the ability to quickly modify, approve, and implement the treatment. Results: Thirty-one patients have been treated with this OSPD treatment, without compromising the plan quality compared to our regular clinically used parallel apposed 2D plans. The average time for these procedures are 48.02 ±11.55 minutes from the time patient entered the treatment room until s/he exited, and 35.09 ±10.35 minutes from starting CBCT until last beam delivered. This time duration is comparable to the net time when individual tasks are summed up during our regular CT- based whole brain planning and delivery. Conclusions: The OSPD whole brain treatment has been tested to be clinically feasible. The next step is to further improve the efficiency and to streamline the workflow. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗

Coupling the System Analysis Module with SAS4A/SASSYS-1

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced reactors, with an emphasis on sodium fast reactors. SAS4A/SASSYS-1 has been under development and in active use for nearly forty-five years, and is currently maintained by the U.S. Department of Energy under the Office of Advanced Reactor Technology. Although SAS4A/SASSYS-1 contains a very capable primary and intermediate system modeling component, PRIMAR-4, it also has some shortcomings: outdated data management and code structure makes extension of the PRIMAR-4 module somewhat difficult. The user input format for PRIMAR-4 also limits the number of volumes and segments that can be used to describe a given system. The System Analysis Module (SAM) is a fairly new code development effort being carried out under the U.S. DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM is being developed with advanced physical models, numerical methods, and software engineering practices; however, it is currently somewhat limited in the system components and phenomena that can be represented. For example, component models for electromagnetic pumps and multi-layer stratified volumes have not yet been developed. Nor is there support for a balance of plant model. Similarly, system-level phenomena such as control-rod driveline expansion and vessel elongation are not represented. This report documents fiscal year 2016 work that was carried out to couple the transient safety analysis capabilities of SAS4A/SASSYS-1 with the system modeling capabilities of SAM under the joint support of the ART and NEAMS programs. The coupling effort was successful and is demonstrated by evaluating an unprotected loss of flow transient for the Advanced Burner Test Reactor (ABTR) design. There are differences between the stand-alone SAS4A/SASSYS-1 simulations and the coupled SAS/SAM simulations, but these are mainly attributed to the limited maturity of the SAM development effort. The severe accident modeling capabilities in SAS4A/SASSYS-1 (sodium boiling, fuel melting and relocation) will continue to play a vital role for a long time. Therefore, the SAS4A/SASSYS-1 modernization effort should remain a high priority task under the ART program to ensure continued participation in domestic and international SFR safety collaborations and design optimizations. On the other hand, SAM provides an advanced system analysis tool, with improved numerical solution schemes, data management, code flexibility, and accuracy. SAM is still in early stages of development and will require continued support from NEAMS to fulfill its potential and to mature into a production tool for advanced reactor safety analysis. The effort to couple SAS4A/SASSYS-1 and SAM is the first step on the integration of these modeling capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗