Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Large moments in BCC FExCOyMNz and other alloy thin films

Large magnetic moment compositions are formed by stabilizing ternary or other alloys with a epitaxial control layer. Compositions that are unstable in bulk specimen are thus stabilized and exhibit magnetic moments that are greater that a Slater-Pauling limit. In one example, FexCoyMnz layers are produced on an MgO(001) substrate with an MgO surface serving to control the structure of the FexCoyMnz layers. Magnetizations greater than 3 Bohr magnetons are produced.

Snow, Ryan L.↗

IEEE 1547-2018 Based Interoperable PV Inverter with Advanced Grid-Support Functions

Grid integration of photovoltaic (PV) inverters has been increasing in the past decade. As a result of the uncertainties introduced with high penetrations of PV, better monitoring and control of the PV inverters becomes crucial for improving overall system stability. This paper focuses on the communications capability of the inverter controller and on enabling interoperability. Multiple standards are available to enable interoperability in PV inverters. In this paper, an interoperable controller, enabled by Distributed Network Protocol 3 (DNP3) communications protocols, is developed for a grid-connected, three-phase PV inverter. The DNP3 server for the PV inverter is programmed on the real-time layer of the field-programmable gate array (FPGA)-based inverter controller. Set points for advanced inverter control functions, such as volt/VAr curves, ride-through curves, are sent from a DNP3 client, a simulated distribution management system application, to the PV inverter through DNP3. This communications capability of the inverter controller is validated using a controller-hardware-in-the-loop experimental setup. The code developed to achieve the interoperability is available in the public domain through open-source software licensing. This interoperability will enable smoother grid integration of smart PV inverters with advanced grid-support functions as well as allow better monitoring and control of PV inverters for grid stability.

14 SOLAR ENERGY↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

Deep Reinforcement Learning Based Control of Wind Turbines for Fast Frequency Response

In order to fulfill vital auxiliary grid services, such as load regulation, spin and non-spin reserve provision, and frequency support during emergencies, there is often a requirement for certain wind farms to operate in de-loaded modes. Leveraging the swift response capabilities of wind farms, this study demonstrates that reserving power in de-loaded modes can significantly enhance power grid stability and reliability during system contingencies. Controlling wind farms optimally for frequency support is intricate due to the nonlinearity of models and controllers and the complexity of wind farm interactions with power systems. Here, to address this challenge, this paper introduces a novel approach that integrates wind turbines into reinforcement learning-based solutions for frequency response. This innovative methodology utilizes the state-of-the-art reinforcement learning algorithm known as the surrogate-gradient-based evolutionary strategy. The proposed learning-based algorithm provides continuous control of wind farm output to rapidly stabilize system frequency and prevent unnecessary trips of under-frequency load shedding relays. To facilitate efficient training, parallel computing techniques are employed. The proposed methodology is evaluated on a modified IEEE-39 bus system, and simulation results reveal its efficacy in reliably supporting power system frequency and preventing the need for unnecessary load shedding.

Gao, Wei [Argonne National Laboratory (ANL), Argon↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

Nonlinear Multiple Models Adaptive Secondary Voltage Control of Microgrids

This article proposes a model-free secondary voltage control (SVC) for microgrids (MG) using nonlinear multiple models adaptive control. Firstly, a linear robust adaptive controller is designed to guarantee the voltage stability in the bounded-input- bounded-output (BIBO) manner so as to meet the operation requirements of MGs. Secondly, a nonlinear adaptive controller is developed to improve the voltage tracking performance with the help of artificial neural networks (ANNs). A switching mechanism for coordinating such two controllers is designed to guarantee the closed-loop stability while achieving accurate voltage tracking. Here, by an online identification based on the input and output data of MGs, the proposed method does not resort to any apriori information of system model and primary control, thus exhibiting good robustness, ease of deployment and disturbance rejection.

17 WIND ENERGY↗

Wideband Impedance Passivation of MMCs for Suppressing Harmonic Oscillations

Harmonic instability and associated oscillation events have become one of the main concerns in MMC-based HVdc systems. These oscillations can appear in the range from a few hundred hertz to several kilohertz, and the root cause is identified as delay-induced negative damping of MMC impedance appearing at the system resonance frequency. Here, this paper introduces a wideband impedance reshaping method through MMC control to eliminate such negative damping for both grid-following (GFL) and grid-forming (GFM) MMCs, which makes the MMC impedance completely passive from the second harmonic frequency upward, thus preventing all harmonic oscillations. First, simplified impedance models of MMCs are derived for the harmonic stability analysis and the impedance reshaping control design. Next, a passivity-based impedance reshaping method is presented, as well as practical considerations for its implementation. In addition, to maintain the MMC's disturbance ride-through capability, an adaptive activation scheme is developed, which enables the wideband impedance reshaping control only in the presence of harmonic oscillation events. The effectiveness of the proposed method is validated by frequency domain analysis and by electromagnetic transient (EMT) simulations of two typical MMC-based power systems.

17 WIND ENERGY↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators: Preprint

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

The role of Si in determining the stability of the θ; precipitate in Al-Cu-Mn-Zr alloys

Precipitate-strengthened Al-Cu-Mn-Zr (ACMZ) alloys demonstrate improved microstructural stability compared to conventional Al-Cu alloys. Si is typically considered an impurity in these alloys, but a systematic analysis of ACMZ alloys with a range of Si levels revealed that there is a Si content range (~0.05 wt. % < Si < ~0.10 wt. %) for achieving optimal high temperature microstructural stability. A combination of hardness testing, scanning electron microscopy, and atom probe tomography has been used to understand the relationship between Si content, aging response, and thermal stability in ACMZ alloys. It is shown that the optimum Si content range corresponds to a reduced as-aged hardness, but a greater hardness value retained by the alloy after thermal exposure to 350 °C for 200 hours. A mechanism is proposed in which optimum Si levels reduce the number density of nucleation sites for θ' precipitates, resulting in larger precipitates that, on average, provide a reduced as-aged strength but are more coarsening resistant. This inherent θ' coarsening resistance allows more time for slow-diffusing Mn and Zr to reach the θ' interface and further stabilize the precipitates. Designing the optimal as-aged microstructure for improved thermal stability of the alloy by controlling impurity levels is a concept that has implications beyond the investigated Al-Cu alloy system.

36 MATERIALS SCIENCE↗

Gravity-driven controls on fluid and carbonate precipitation distributions in fractures

Abstract Many challenges related to carbon-dioxide ( $$\hbox {CO}_2$$ CO 2 ) sequestration in subsurface rock are linked to the injection of fluids through induced or existing fracture networks and how these fluids are altered through geochemical interactions. Here, we demonstrate that fluid mixing and carbonate mineral distributions in fractures are controlled by gravity-driven chemical dynamics. Using optical imaging and numerical simulations, we show that a density contrast between two miscible fluids causes the formation of a low-density fluid runlet that increases in areal extent as the fracture inclination decreases from 90 $$^\circ$$ ∘ (vertical fracture plane) to 30 $$^\circ$$ ∘ . The runlet is sustained over time and the stability of the runlet is controlled by the gravity-driven formation of 3D vortices that arise in a laminar flow regime. When homogeneous precipitation was induced, calcium carbonate covered the entire surface for horizontal fractures (0 $$^\circ$$ ∘ ). However, for fracture inclinations greater than 10 $$^\circ$$ ∘ , the runlet formation limited the areal extent of the precipitation to less than 15% of the fracture surface. These insights suggest that the ability to sequester $$\hbox {CO}_2$$ CO 2 through mineralization along fractures will depend on the fracture orientation relative to gravity, with horizontal fractures more likely to seal uniformly.

54 ENVIRONMENTAL SCIENCES↗

Model Predictive Control-Based Trajectory Shaper for Safe and Efficient Adaptive Cruise Control

Recent studies show that commercially-available adaptive cruise control (ACC) systems are string-unstable, indicating that ACC-driven vehicles amplify speed fluctuations from downstream traffic and induce stop-and-go waves. Moreover, it is challenging to revise the original control algorithm of an ACC system to achieve string stability due to its internal complexity and powertrain uncertainties. To achieve desired control performance given a string-unstable ACC system and circumvent revising the original control algorithm, this study proposes a model predictive control-based trajectory shaper (MPC-TS), which only modifies the sensor-measured trajectory information (i.e., position and speed) of the preceding vehicle. The proposed MPC-TS leverages the input shaping technique to generate reference trajectory to improve string stability, while incorporating tracking errors and vehicle acceleration/deceleration magnitude in the MPC cost function and constraining fluctuations of vehicle speed and spacing to ensure desired car-following performance. Numerical experiments validate the control performance of ACC with the proposed MPC-TS in terms of string stability, safety, traffic efficiency, and comfort.

Zhou, Anye↗

Compositional Phase Control in High-Entropy Alloy Electrocatalysts

High-entropy alloys (HEAs) provide uniquely tunable structural and electronic properties that enable robust electrocatalysis. While compositional manipulation of HEAs is well-known, systematically controlling the crystalline phase and morphology remains a challenge that could provide new avenues for controlling reactive sites and physical properties. Here, we show the preferential stabilization of mixed fcc/bcc to fcc phases by controlling the Au content in quinary AuPdFeCoNi HEA nanoparticles. This systematic structural and compositional control, when investigated with an ensemble of electronic, X-ray synchrotron, and surface techniques, allows us to identify the critical short- (few-Å) and medium- (6–10 Å) range structural motifs that deliver exceptional hydrogen evolution reaction (HER) catalysis. Specifically, these HEAs exhibit both outstanding durability (240 h) and high mass activity (50 A/mg PGM ) normalized to noble metal content, outperforming commercial Pt/C (3.18 A/mg PGM ). This structural control over HEA morphology, and its direct association with changes in specific metallic oxidation states and pair–pair atomic structural features, provides new means and strategies for finely designing robust and sustainable electrocatalysts with a majority nonprecious metal composition.

36 MATERIALS SCIENCE↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Tobin, Matthew [Columbia Univ., New York, NY (Unit↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

AMOC stability and diverging response to Arctic sea ice decline in two climate models

This study compares the impacts of Arctic sea ice decline on the Atlantic meridional overturning circulation (AMOC) in two configurations of the Community Earth System Model with different horizontal resolution. In a suite of model experiments, we impose radiative imbalance at the ice surface, replicating a loss of sea ice cover comparable to that observed during 1979–2014, and we find dramatic differences in the AMOC response between the two models. In the lower-resolution configuration, the AMOC weakens by about one-third over the first 100 years, approaching a new quasi-equilibrium. By contrast, in the higher-resolution configuration, the AMOC weakens by ~10% during the first 20–30 years followed by a full recovery driven by invigorated deep water formation in the Labrador Sea and adjacent regions. We investigate these differences using a diagnostic AMOC stability indicator, which reflects the AMOC freshwater transport in and out of the basin and hence the strength of the basin-scale salt-advection feedback. This indicator suggests that the AMOC in the lower-resolution model is less stable and more sensitive to surface perturbations, as confirmed by hosing experiments mimicking Arctic freshening due to sea ice decline. Differences between the models’ mean states, including the Atlantic Ocean mean surface freshwater fluxes, control the differences in AMOC stability. Our results demonstrate that the AMOC stability indicator is indeed useful for evaluating AMOC sensitivity to perturbations. We emphasize that, despite the differences in the long-term adjustment, both models simulate a multidecadal AMOC weakening caused by Arctic sea ice decline, relevant to climate change.

54 ENVIRONMENTAL SCIENCES↗