Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Nondestructive Evaluation of Foam Insulation on the Space Shuttle External Tank

Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased interest in other causes of foam loss following the flight of Discovery in July 2005, laser shearography was added to the techniques used for inspecting ET foam. The shearography method records a sheared image of a laser speckle pattern projected on a test part before And after some sort of excitation. The resultant fringe pattern allows the slope of the out of plane displacement to be measured. For crushed and delaminated foam applications, a non-contact air coupled acoustic force is used to excite the surface of the foam. Regions without defects tend to respond differently to the sound energy than do regions with defects, generating a map of the foam integrity. Foam crushed to a depth of about 0.1 inches is detectable with shearography even after it has relaxed to its original shape.

Richter, Joel↗

Design of a dynamic biofilm imaging cell for white-light interferometric microscopy

In microbiology research there is a strong need for next generation imaging and sensing instrumentation that will enable minimally invasive and label-free investigation of soft, hydrated structures such as in bacterial biofilms. White light interferometry (WLI) can provide high resolution images of surface topology without the use of fluorescent labels but is not typically used to image biofilms because there is insufficient refractive index contrast to induce reflection from the biofilm’s interface. The soft structure and water-like bulk properties of hydrated biofilms make them difficult to characterize in situ , especially in a non-destructive manner. In this report, we build on our prior description of static biofilm imaging and describe the design of a dynamic imaging flow cell that enables monitoring the thickness and topology of live biofilms over time using a WLI microscope. The microfluidic system is specifically designed to create a reflective interface on the surface of biofilms while minimizing disruption of fragile structures. The imaging cell was also designed to accommodate limitations imposed by the depth of focus of the microscope’s objective lens. Example images of live biofilm samples are shown in order to illustrate the ability of the flow cell and WLI instrument to 1) support bacterial growth and biofilm development, 2) image biofilm structure that reflects growth in flow conditions, and 3) monitor biofilm development over time non-destructively. In future work, the apparatus described here will enable surface metrology measurements (roughness, surface area, etc.) of biofilms and may be used to observe changes in biofilm structure in response to changes in environmental conditions (e.g., flow velocity, availability of nutrients, and presence of biocides). Furthermore, this development will open new opportunities for the use of WLI in bioimaging.

47 OTHER INSTRUMENTATION↗

VISIR/VLT AND VLA JOINT IMAGING ANALYSIS OF THE CIRCUMSTELLAR NEBULA AROUND IRAS 18576+0341

High spatial and sensitivity images of the Luminous Blue Variable IRAS 18576+0341 were obtained using the mid-infrared imager VISIR at the Very Large Telescope and the Very Large Array interferometer. The resulting mid-infrared continuum maps show a similar clumpy and approximately circular symmetric nebula, which contrasts sharply with the asymmetry that characterizes the ionized component of the envelope, as evidenced from the radio and [Ne II] line images obtained with comparable spatial resolution. In particular, there is excellent overall agreement between the 12.8 {mu}m map and the radio images, consistent with free-free emission from circumstellar ionized material surrounding a central stellar wind. The color temperature and optical depth maps obtained from mid-infrared images show only slight fluctuations, suggesting quite uniform dust characteristics over the dust shell. We explore various possibilities to understand the cause of the different morphology of the dusty and gaseous component of the circumstellar envelope which are compatible with the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster — Thur Eve — 18: Cherenkov Emission By High-Energy Radiation Therapy Beams: A Characterization Study

We investigate Cherenkov emission (CE) by radiotherapy beams via radiation dose-versus-CE correlation analyses, CE detection optimization by means of a spectral shift towards the near-infrared (NIR) window of biological tissue, and comparison of CE to on-board MV imaging. Dose-CE correlation was investigated via simulation and experiment. A Monte Carlo (MC) CE simulator was designed using Geant4. Experimental phantoms include: water; tissue-simulating phantom composed of water, Intralipid®, and beef blood; plastic phantom with solid water insert. The detector system comprises an optical fiber and diffraction-grating spectrometer incorporating a front/back-illuminated CCD. The NIR shift was carried out with CdSe/ZnS quantum dots (QDs), emitting at (650±10) nm. CE and MV images were acquired with a CMOS camera and electronic portal imaging device. MC and experimental studies indicate a strong linear dose-CE correlation (Pearson coefficient > 0.99). CE by an 18-MeV beam was effectively NIR-shifted in water and a tissue-simulating phantom, exhibiting a significant increase at 650 nm for QD depths up to 10 mm. CE images exhibited relative contrast superior to MV images by a factor of 30. Our work supports the potential for application of CE in radiotherapy online imaging for patient setup and treatment verification, since CE is intrinsic to the beam and non-ionizing and QDs can be used to improve CE detectability, potentially yielding image quality superior to MV imaging for the case of low-density-variability, low-optical-attenuation materials (ex: breast/oropharynx). Ongoing work involves microenvironment functionalization of QDs and application of multi-channel spectrometry for simultaneous acquisition of dosimetric and tumor oxygenation signals.

07 ISOTOPE AND RADIATION SOURCES↗

Context Imaging Raman Spectrometer

Methods and systems for Raman spectroscopy and context imaging are disclosed. One or two lasers can be used to excite Raman scattering in a sample, while a plurality of LEDs can illuminate the sample at a different wavelength. The LED light is collected by a lenslet array in order to enable a high depth of field. Focusing of the image can be carried out at specific points of the image by processing the light collected by the lenslet array.

Lambert, James L.↗

Study of the marine environment of the northern Gulf of California

The author has identified the following significant results. Preliminary analysis of the first three months of ERTS-1 imagery have revealed that the MSS images have particular utility for study of turbidity patterns, current phenomena, and bathymetry throughout the test area. Early indications are that well defined spatial distributions of turbidity exist in the northern Gulf of California, and that for any one point in time, these distributions vary with depth. From a single set of images, as many as 3 turbidity maps may be generated, each indicating a vertical spatial relationship of the turbidity masses. The spatial distribution of turbidity masses depend partially upon the coincident currents. In the band of deepest penetration, a map can be gathered which roughly corresponds to the bathymetry of the area. The extreme tides in the northern Gulf of California result in vast areas which can be classified as intertidal mud flats. Information on the amount of exposure at the varying tidal states is important in analysis of these mud flat areas as nursery ground for Mexican commercial fisheries.

Hendrickson, J. R.↗

SU-F-J-26: Performance of 2.5MV Portal Imaging in Comparison with KV X-Ray and 6MV and Flattening-Filter-Free 6MV Portal Imaging

Purpose: To assess image quality and imaging dose of 2.5MV electronic portal imaging in comparison to kV imaging and 6MV and Flattening-Filter-Free 6MV (6MVFFF) portal imaging using a DMI imager. Methods: Quantitative assessment of image quality was performed with Leeds and Las Vegas test phantoms in conjunction with qualitative evaluation of clinical patient images for kV imaging and 2.5MV, 6MV and 6MVFFF portal imaging. High and low contrast resolutions were evaluated and imaging doses were measured using these x-rays. Phantom test was performed both in air and in solid water. Clinical patient portal images were also reviewed and qualitatively assessed for these three imaging MV energies. Results: Among the 28 objects in Las Vegas phantom, 16, 17 and 26 of them were resolved using Low Dose technique and 18, 22 and 26 were resolved using High Quality technique with 6MV, 6MVFFF and 2.5MV, respectively. The number of Leeds low contrast objects resolved by 6MV, 6MFFFF and 2.5MV was 6, 15 and 18 with Low Dose technique and 14, 17 and 18 with High Quality technique, respectively. When the test phantoms were embedded in 20cm thick solid water, the results were noticeably affected, but the performance of 2.5MV was still substantially better than 6MV and 6MVFFF. Imaging dose with 2.5MV measured at 10 cm depth was about half of that with 6MV or 6MVFFF. Clinical patient portal images were reviewed and qualitatively assessed for different sites including brain, head-and-neck, chest and pelvis. 2.5MV imaging provided more details and substantially higher contrast. Conclusion: While portal imaging with 6MVFFF provides noticeably better image quality than that with 6MV, the performance of 2.5MV portal imaging is substantially better than both 6MV and 6MVFFF in terms of high and low contrast resolutions as well as lower imaging dose. 2.5MV imaging provides near kV imaging quality.

60 APPLIED LIFE SCIENCES↗

Absorber height effects on SWA restrictions and 'Shadow' LER

As extreme-ultraviolet lithography (EUVL) approaches introduction at the 22-nm half-pitch node, several key aspects of absorber height effects remain unexplored. In particular, sidewall angle (SWA) restrictions based on the height of the mask absorber has not yet been clearly defined. In addition, the effects of absorber height on line-edge roughness (LER) from shadowing has not been examined. We make an initial investigation into how tight SWA constraints are and the extent to which shadow LER alters basic LER. Our approach to SWA aims to find SWA restrictions based on 10% of the total CD error budget (10% of CD). Thus, we allot the SWA budget a {+-}0.2nm tolerance for 22nm half-pitch. New with EUVL is the off-axis illumination system. One potential pitfall that must be carefully monitored is the effect of mask absorber height blocking light from reaching, and therefore, correctly detecting, the base edge position of a feature. While mask features can correctly compensate sizing to target at the wafer, the effects of this shadowing on LER have not yet been investigated. Specifically, shadow LER may exacerbate or mitigate the inherent LER on the mask. Shadowing may also cause a difference in the observed LER on the right and left side of the features. We carefully probe this issue for a range of spatial frequencies. We do rigorous aerial image modeling of mask features with a nominal SWA of 80 degrees and correctly sized to target 22nm features measured at the top, 70nm TaN absorber on a 40 bilayer ML mirror with a 2.5nm Ru cap. Simulations were on a 4X system with an ideal pupil of NA = 0.32, illumination wavelength 13.4nm at 6{sup o} off-axis, and disk source shape with partial coherence factor of {sigma} = 0.50. We first implement a defocus offset to the aerial image so that best focus lies at a nominal zero defocus value. We then calculate the depth of focus (DOF) for which the image-log-slope (ILS) delivers a contrast is greater than 50%, an arbitrary standard for a good quality photoresist to print. Using this DOF, we optimize the process window and adjust the intensity threshold from it's nominal value to a new optimal value. From this optimized intensity threshold, we calculated the aerial image CD through focus for a range of angles around the nominal SWA value. From this, we can find out how much the SWA needs to be constrained by in order to keep the {+-}10% CD error budget tolerance required. For SWA of 80 degrees, we found the nominal SWA is tightly constrained by 0.5 degrees. We repeated these calculations for other nominal values of SWA 85 and 88 degrees, and found that CD sensitivity to nominal SWA is relatively independent. In examining shadow LER, we use FDTD simulations to obtain a rigorous solution for the source intensity immediately after the patterned TaN mask absorber pattern on a 2.5nm Ru capped 40 bilayer ML mirror. The optical system was comprised of an ideal pupil map, NA = 0.32, 13.4nm light at 4{sup o} off-axis, and annular source shape with partial coherence factor of {sigma} = 0.35-0.55. We assumed a 90{sup o} SWA. For the basic 2D shape of the mask that we exactly replicated through height, we created mask LER by generating a sine wave of full amplitude 4nm, equivalent to 4nm LER, (wafer dim.), confined along it's length to precisely CD=22nm, for sine waves with spatial frequencies (full period) of 25, 50, 75, 100, 125, 150, 175, and 200nm (wafer dim.), and illuminated at both {phi}=0{sup o} (perpendicular, shadowing) and {phi}=90{sup o} (parallel, no shadowing). Results show that even off-axis illumination perpendicular to the lines and spaces gives minimal difference between the left and right LER to at most 0.1nm difference at best focus. We followed up this study by repeating the data for a mask designed with 2nm LER with similar results. A plot of the transfer functions for LER of both 2nm and 4nm compared to the contrast of simple 50% duty cycle lines and spaces shows that LER has a unique transfer function as well as a linear response to LER amplitude. In the course of our investigation of SWA, we found that the nominal angle has no effect on process window size, and neither does sensitivity on changing angle alter as a function of nominal angle. For nominal 80{sup o}, 85{sup o}, 88{sup o} SWA, the amount of angle tolerance for 0.2nm change in CD was in total 0.5{sup o}. For shadow LER, we found minimal difference between left and right LER when illuminated perpendicularly to the pattern, to at most 0.1nm LER at best focus. CTFs confirm the uniqueness and linearity of an LER transfer function as opposed to the traditional MTF, as shown in a previous study. In the future we wish to expand our work on shadow LER into the regime where the k{sub 1}-factor of the optic is stressed. In particular, 16nm lines and spaces on an NA = 0.32 optic with off-axis illumination.

36 MATERIALS SCIENCE↗

Effect of Air Oxidation on Pore Structure Development and Mechanical Properties of Nuclear Graphite

This document reports on continuation of R&D activities at ORNL directed at investigating the effect of air oxidation of nuclear graphite on development and structure of porosity in the oxidized layer, and on the effect on mechanical properties of oxidized graphite. The material investigated was nuclear-grade graphite (purified PCEA graphite, from GrafTech International). Based on conclusions of previous work (ORNL/TM-2009/192), the method of analysis of the porosity in the oxidized layer based on optical microscopy coupled with automated image analysis was further improved and standardized. In addition, characterization of oxidized specimens by optical microscopy was complemented with measurements of mechanical properties (compressive strength) on a statistically significant number of specimens. A series of cylindrical shape specimens were machined and oxidized in air at two temperatures (600 and 700 o C) and at three levels of burn-off at each temperature (5-6 %; 10-12 % and 15-17%). The procedure used for specimen preparation and oxidation, and the oxidation equipment, were those recommended in ASTM D-7542-09. However, in order to comply with the aspect ratio requirements for specimens employed in compressive strength measurements (ASTM C-695-91) all specimens were machined with a length to diameter ratio of 2 (i.e. 25.4 mm height vs. 12.7 mm diameter) instead of 25.4 mm length and 25.4 mm diameter recommended by ASTM D-7542-09. After oxidation, mechanical properties (compressive strength) were measured on at least three samples obtained at equal oxidation conditions, while another specimen from the same lot was sectioned, mounted in resin and surface polished for optical microscopy analysis. In the latter procedure, mosaic pictures were collected of a rectangular stripe across the diameter of each specimen. These images were analyzed in order to derive the penetration depth and the pore structure in the oxidized layer as a function of oxidation temperature and weight loss level. Automated image analysis was performed using the commercial software Image Pro Plus. The results led to the conclusion that the depth of the oxidation layer is more dependent on the oxidation temperature than on the level of weight-loss. The penetration depth of the oxidized layer is about 6 mm at 600 o C and about 1.5 mm at 700 o C. Consequently, the 12.5 mm diameter specimens oxidized at 600 o C were completely penetrated by oxidation, while those oxidized at 700 o C had the oxidation layer restricted in a narrower band near the exposed surface. This difference was reflected by mechanical properties. A closer analysis of high magnification images in the oxidized layer revealed that oxidation attacks preferentially the binder phase in graphite, where development of fine new pores was observed. The density of new pores was higher near large pores pre-existing in graphite structure. Acute oxidation at low temperatures (e.g. 600 o C) causes more damage on mechanical strength than high temperature oxidation (700 o C). Although the latter is much faster, the oxidized layer is limited to a narrow zone next to the external surface, so that the core is not visibly affected. In contrast, oxidation at lower temperature, although slower, is more damaging because it penetrates deeply beyond the exposed surface.

36 MATERIALS SCIENCE↗

SU-C-BRE-04: Microbeam-Radiation-Therapy (MRT): Characterizing a Novel MRT Device Using High Resolution 3D Dosimetry

Purpose: The feasibility of MRT has recently been demonstrated utilizing a new technology of Carbon-Nano-Tube(CNT) field emission x-ray sources.This approach can deliver very high dose(10's of Gy) in narrow stripes(sub-mm) of radiation which enables the study of novel radiation treatment approaches. Here we investigate the application of highresolution (50um isotropic) PRESAGE/Optical-CT 3D dosimetry techniques to characterize the radiation delivered in this extremely dosimetrically challenging scenario. Methods: The CNT field emission x-ray source irradiator comprises of a linear cathode array and a novel collimator alignment system. This allows a precise delivery of high-energy small beams up to 160 kVp. A cylindrical dosimeter (∼2.2cm in height ∼2.5cm in diameter) was irradiated by CNT MRT delivering 3 strips of radiation with a nominal entrance dose of 32 Gy.A second dosimeter was irradiated with similar entrance dose, with a regular x-ray irradiator collimated to microscopical strip-beams. 50um (isotropic) 3D dosimetry was performed using an in-house optical-CT system designed and optimized for high resolution imaging (including a stray light deconvolution correction).The percentage depth dose (PDD), peak-to-valley ratio (PVR) and beam width (FWHM) data were obtained and analyzed in both cases. Results: High resolution 3D images were successfully achieved with the prototype system, enabling extraction of PDD and dose profiles. The PDDs for the CNT irradiation showed pronounced attenuation, but less build-up effect than that from the multibeam irradiation. The beam spacing between the three strips has an average value of 0.9mm while that for the 13 strips is 1.5 mm at a depth of 16.5 mm. The stray light corrected image shows line profiles with reduced noise and consistent PVR values. Conclusion: MRT dosimetry is extremely challenging due to the ultra small fields involved.This preliminary application of a novel, ultra-high resolution, optical-CT 3D dosimetry system shows promise, but further work is required to validate and investigate accuracy and artifacts. This work was supported by NIH R01CA100835.

07 ISOTOPE AND RADIATION SOURCES↗

Aerosol Optical Depth Distribution in Extratropical Cyclones over the Northern Hemisphere Oceans

Using Moderate Resolution Imaging Spectroradiometer and an extratropical cyclone database,the climatological distribution of aerosol optical depth (AOD) in extratropical cyclones is explored based solely on observations. Cyclone-centered composites of aerosol optical depth are constructed for the Northern Hemisphere mid-latitude ocean regions, and their seasonal variations are examined. These composites are found to be qualitatively stable when the impact of clouds and surface insolation or brightness is tested. The larger AODs occur in spring and summer and are preferentially found in the warm frontal and in the post-cold frontal regions in all seasons. The fine mode aerosols dominate the cold sector AODs, but the coarse mode aerosols display large AODs in the warm sector. These differences between the aerosol modes are related to the varying source regions of the aerosols and could potentially have different impacts on cloud and precipitation within the cyclones.

MODIS↗

Correlative nm-Scale Nonuniformity of Active Charge Carriers and Electrical Potential Along Both the Plane-View and Depth Directions in Group-V-Doped CdTe Thin Films: Preprint

We report nanometer-scale imaging on inhomogeneous distributions of active carrier and electrical potential in an As-doped CdTe film along both plane-view and film-depth directions. Despite Se grading, the SCM imaging does not show a clear variation of carrier concentration along the depth of the film. Instead, we observe carrier concentration variations of about 1 order of magnitude (high 1015 to low 1017/cm3) with inhomogeneous spatial regions ranging from a few hundred nm to a few ?m. This nonuniformity is distributed randomly in both the film lateral and vertical directions, independent of grain structure and GBs. We further mapped the surface potential using Kelvin probe force microscopy (KPFM). Higher potential was found on GBs, illustrating positive GB charging but not GB-specific carrier concentration. The results indicate that this suite of techniques can help identify nonuniform carrier concentration and potential fluctuations that can contribute to Voc deficits in GrV-doped CdTe devices.

CdTe thin film photovoltaics↗

Exploration of LIBS as a novel and rapid elemental mapping technique of nuclear fuels in the form of surrogate TRISO particles

Laser-induced breakdown spectroscopy (LIBS) was employed to characterize coatings on surrogate fuel particles. Tri-structural isotropic (TRISO) particles are a proposed nuclear fuel alternative for high temperature reactors. These particles are constructed of a ZrO 2 kernel (as a surrogate to uranium), surrounded by an inner pyrolytic carbon layer and are surrounded by an outer carbide layer (ZrC, presented here) to act as a barrier to fission products generated during nuclear reactions. These particles are embedded within a graphite compact and housed within the reactor core. Simply put, due to their robust nature, performing elemental analysis of these particles poses a challenge. Presented here, LIBS is explored as a method for characterizing elemental constituents of these particles, with the focus being on rapid elemental mapping and depth profiling. Different from traditional elemental analysis techniques (e.g., inductively coupled plasma – based methods), LIBS is advantageous because it can directly analyze the sample surface and can detect light elements such as C and O, making it a viable technique for the analysis of small, multilayered particles as spatial elemental information is warranted in the production of these particles. In the work presented here, LIBS was successfully used for discerning small layers (30–50 μm), detecting the location of carbon and oxygen layers, providing fast 2-D mapping (<5 min per particle) and rapid depth profiling (10 s per particle).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding FLiNaK Salt Intrusion Behavior on Nuclear-Grade Graphite via Neutron Tomography

Graphite is an essential material as a neutron moderator in molten salt reactors (MSRs). To understand the impact of salt on the graphite structure to develop structural materials for MSRs, molten salt intrusion behavior on nuclear-grade graphite was studied. The graphite samples, IG-110 and PCEA, were tested for infiltration with LiF-NaF-KF (FLiNaK) at 750°C, 5 bar for 12 h, and, after the intrusion experiment, the graphite was analyzed by neutron imaging. The graphite and Li from FLiNaK showed great contrast in the neutron attenuation coefficient. Thus, the salt behavior in the graphite structure has been visualized for the first time without damaging the sample. The 3D image of the graphite was reconstructed after a neutron computed tomography scan, and the average salt coverage distribution of the XY surface in different depths was obtained from the reconstructed 3D images.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utilizing Highly Scattered Light for Intelligence through Aerosols

This communication is the final report for the project Utilizing Highly Scattered Light for Intelligence through Aerosols funded by the Laboratory Directed Research and Development (LDRD) program at Sandia National Laboratories and lasting six months in 2019. Aerosols like fog reduce visibility and cause down-time that for critical systems or operations are unacceptable. Information is lost due to the random scattering and absorption of light by tiny particles. Computational diffuse optical imaging methods show promise for interpreting the light transmitted through fog, enabling sensing and imaging to improve situational awareness at depths 10 times greater than current methods. Developing this capability first requires verification and validation of diffusion models of light propagation in fog. For this reason, analytical models were developed and compared to experimental data captured at the Sandia National Laboratory Fog Chamber facility. A methodology was developed to incorporate the propagation of scattered light through the imaging optics to a pixel array. The diffusion approximation to the radiative transfer equation was found to predict light propagation in fog under the appropriate conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the Tev Region With Calet on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10 5 ), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from −3.15 to −3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

O. Adriani↗

Volumetric 3D Display System with Static Screen

Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous approaches, so there is no image jitter, and has an inherent parallel mechanism for 3D voxel addressing. High spatial resolution is possible with a full color display being easy to implement. The system is low-cost and low-maintenance.

Geng, Jason↗

Mid-Latitude versus Polar-Latitude Transitional Impact Craters: Geometric Properties from Mars Orbiter Laser Altimeter (MOLA) Observations and Viking Images

One intriguing aspect of martian impact crater morphology is the change of crater cavity and ejecta characteristics from the mid-latitudes to the polar regions. This is thought to reflect differences in target properties such as an increasing presence of ice in the polar regions. Previous image-based efforts concerning martian crater morphology has documented some aspects of this, but has been hampered by the lack of adequate topography data. Recent Mars Orbiter Laser Altimeter (MOLA) topographic profiles provide a quantitative perspective for interpreting the detailed morphologies of martian crater cavities and ejecta morphology. This study is a preliminary effort to quantify the latitude-dependent differences in morphology with the goal of identifying target-dependent and crater modification effects from the combined of images and MOLA topography. We combine the available MOLA profiles and the corresponding Viking Mars Digital Image Mosaics (MDIMS), and high resolution Viking Orbiter images to focus on two transitional craters; one on the mid-latitudes, and one in the North Polar region. One MOLA pass (MGS Orbit 34) traverses the center of a 15.9 km diameter fresh complex crater located at 12.8degN 83.8degE on the Hesperian ridge plains unit (Hvr). Viking images, as well as MOLA data, show that this crater has well developed wall terraces and a central peak with 429 m of relative relief. Three MOLA passes have been acquired for a second impact crater, which is located at 69.5degN 41degE on the Vastitas Borealis Formation. This fresh rampart crater lacks terraces and central peak structures and it has a depth af 579 m. Correlation between images and MOLA topographic profiles allows us to construct basic facies maps of the craters. Eight main units were identified, four of which are common on both craters.

Matias, A.↗