At least 487 records · Page 27

Relay NBS Graft with the Plus Delivery System to Improve Deployment in Aortic Arch with Small Radius Curve

The purpose of this report is to describe deployment of the Relay NBS Thoracic Stent Graft with the Plus Delivery System (Bolton Medical, Sunrise, FL) in a flexible resin arch model with a 15-mm radius curve as well as our preliminary clinical results. The Relay NBS graft with the Plus Delivery System was evaluated by way of bench testing, which was performed with stent grafts with diameters ranging from 24 to 46 mm and lengths ranging from 100 to 250 mm in flexible resin arch models with a 15-mm arch radius of curvature. The deployment sequence was analyzed. The Relay NBS graft with the Plus Delivery System was deployed in two patients, respectively, having a 6.5-cm penetrating aortic ulcer of the proximal third of the descending thoracic aorta and a DeBakey type-I aortic dissection with chronic false lumen dilatation after surgery due to an entry site at the distal thoracic aorta. Bench tests showed proper conformation and apposition of the Relay NBS graft with the Plus Delivery System in the flexible resin model. This stent graft was deployed successfully into the two patients with a correct orientation of the first stent and without early or late complications. The Relay NBS graft with the Plus Delivery System ensures an optimal conformation and apposition of the first stent in the aortic arch with a small radius of curvature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Revascularization of Chronically Thrombosed Arteriovenous Fistulas and Grafts for Hemodialysis: A Retrospective Study in 15 Patients With 18 Access Sites

The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-year period, we reviewed a total of 924 interventions performed for dysfunction and/or failed hemodialysis vascular access sites and permanent catheters in 881 patients. In patients whose vascular access-site problems were considered untreatable or were considered treatable with a high risk of failure and access-site abandonment, we attempted to revascularize (resurrect) the chronically occluded and long-discarded (mummy) vascular access sites. We attempted to resurrect a total of 18 mummy access sites (mean age 46.6 {+-} 38.7 months; range 5-144) in 15 patients (8 women and 7 men; mean age 66.2 {+-} 11.5 years; age range 50-85) and had an overall technical success rate of 77.8%. Resurrection failure occurred in 3 fistulas and in 1 straight graft. The clinical success rate was 100% at 2 months after resurrection. In the 14 resurrected vascular access sites, 6 balloon-assisted maturation procedures were required in 5 fistulas; after access-site maturation, a total of 22 interventions were performed to maintain access-site patency. The mean go-through time for successful resurrection procedures was 146.6 {+-} 34.3 min (range 74-193). Postmaturation primary patency rates were 71.4 {+-} 12.1% at 30 days, 57.1 {+-} 13.2% at 60 days, 28.6 {+-} 13.4% at 90 days, and 19 {+-} 11.8% at 180 days. Postmaturation secondary patency rates were 100% at 30, 60, and 90 days and 81.8 {+-} 11.6% at 180 days. There were 2 major complications consisting of massive venous ruptures in 2 mummy access sites during balloon dilation; in both cases, prolonged balloon inflation failed to achieve hemostasis, but percutaneous N-butyl cyanoacrylate glue seal-off was performed successfully. Percutaneous resurrection of mummy vascular access sites for hemodialysis is technically feasible with high clinical success rates. In selected patients, resurrection of mummy access sites provides long-discarded access sites one more chance to be used for hemodialysis in an effort to preserve potential extremity sites for future access-site placement and to prevent long-term catheter indwelling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Dedicated Balloon Catheter for Infrapopliteal Difficult Calcified Lesions in Diabetic Patients With Critical Limb Ischemia

The purpose of this study was to assess the technical performance and immediate procedural outcome of a new balloon catheter in the treatment of calcified lesions in infrapopliteal arterial disease. Sixty-one patients (81 vessels) with infrapopliteal arterial disease were evaluated. Seventy-four of the 81 treated vessels had total occlusions. The ReeKross 18 peripheral transluminal angioplasty catheter (ClearStream, Wexford, Ireland) is an 0.018-inch guidewire system with 4F sheath compatibility and a rigid shaft intended for enhanced pushability. Only technical procedural outcomes were recorded. In 37 of 61 patients (50 infrapopliteal severely stenosed or occluded vessels), an attempt with a standard balloon was made before the ReeKross 18 was used. In 24 patients, the ReeKross 18 was used as the primary catheter in 23 cases involving crural arteries and in 8 cases involving the foot. The ReeKross 18 crossed the lesion in 55 of 59 (93.2%) patients and 72 of 77 (94.5%) vessels, respectively. Postdilatation results for the 51 patients (64 target lesions) in whom ReeKross 18 balloon dilation was achieved showed <30% residual stenosis in all but 4 patients (5 lesions). Of the patients treated with the ReeKross 18 as the primary catheter, the technical success rate (no adjunctive treatment/stent) was obtained in 20 of 24 (83.3%) patients (27 of 31 [87.1%] target lesions). In the treatment of difficult calcified lesions, the choice of a high-pushability angioplasty catheter, such as the ReeKross 18, warrants consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Thrombotic Mesenteric Ischemia: Primary Endovascular Treatment in Eight Patients

Introduction: The purpose of this study was to evaluate our experience with initial percutaneous transluminal angioplasty (PTA) {+-} stenting as valuable options in the acute setting. Methods: Between 2003 and 2008, eight patients with abdominal angio-MDCT-scan proven thrombotic AMI benefited from initial PTA {+-} stenting. We retrospectively assessed clinical and radiological findings and their management. Seven patients presented thrombosis of the superior mesenteric artery, and in one patient both mesenteric arteries were occluded. All patients underwent initial PTA and stenting, except one who had balloon PTA alone. One patient was treated by additional in situ thrombolysis. Results: Technical success was obtained in all patients. Three patients required subsequent surgery (37.5%), two of whom had severe radiological findings (pneumatosis intestinalis and/or portal venous gas). Two patients (25%) died: both had NIDD, an ASA score {>=}4, and severe radiologic findings. Satisfactory arterial patency was observed after a follow-up of 15 (range, 11-17) months in five patients who did not require subsequent surgery, four of whom had abdominal guarding but no severe CT scan findings. One patient had an ileocecal stenosis 60 days after the procedure. Conclusions: Initial PTA {+-} stenting is a valuable alternative to surgery for patients with thrombotic AMI even for those with clinical peritoneal irritation signs and/or severe radiologic findings. Early surgery is indicated if clinical condition does not improve after PTA. The decision of a subsequent surgery must be lead by early clinical status reevaluation. In case of underlying atherosclerotic lesion, stenting should be performed after initial balloon dilatation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Newly Designed Y-configured Single-Catheter Stenting for the Treatment of Hilar-Type Nonanastomotic Biliary Strictures After Orthotopic Liver Transplantation

Purpose: This study was designed to introduce our novel technique of percutaneous single catheter placement into the hilar bile ducts strictures while fulfilling the purpose of bilateral biliary drainage and stenting. We investigated the efficacy and safety of the technique for the treatment of hilar nonanastomotic biliary strictures. Methods: Ten patients who were post-orthotopic liver transplantation between July 2000 and July 2010 were enrolled in this study. Percutaneous Y-configured single-catheter stenting for bilateral bile ducts combined with balloon dilation was designed as the main treatment approach. Technical success rate, clinical indicators, complications, and recurrent rate were analyzed. Results: Technical success rate was 100%. Nine of the ten patients had biochemical normalization, cholangiographic improvement, and clinical symptoms relief. None of them experienced recurrence in a median follow-up of 26 months after completion of therapy and removal of all catheters. Complications were minor and limited to two patients. The one treatment failure underwent a second liver transplantation but died of multiple system organ failure. Conclusions: Percutaneous transhepatic Y-configured single-catheter stenting into the hilar bile ducts is technically feasible. The preliminary trial of this technique combined with traditional PTCD or choledochoscopy for the treatment of hilar biliary strictures after orthotopic liver transplantation appeared to be effective and safe. Yet, further investigation is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Paget-Schroetter Syndrome Treated with Cutting-Balloon Angioplasty

Here, a case of Paget-Schroetter Syndrome in a 25-year-old guitar player is reported. After thrombolysis, conventional angioplasty failed to dilate the underlying subclavian stenosis both before and after first-rib excision with scalenus anterior and medius division. For the third attempt at angioplasty, a cutting balloon was used, which immediately produced a good result. Venography at 4-year follow-up showed no restenosis and no functional deficit. This case report demonstrates that cutting-balloon angioplasty may be considered when conventional balloon fails and may have greater durability than conventional balloon angioplasty in the treatment of Paget-Schroetter syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization to Treat Uterine Adenomyosis with or without Uterine Leiomyomata: Results of Symptom Control and Health-Related Quality of Life 40 Months after Treatment

Purpose: To evaluate the clinical outcome for uterine adenomyosis with or without uterine leiomyomata 40 months after uterine artery embolization (UAE). Methods: Forty women aged 39-56 years (median 46 years) with symptomatic uterine adenomyosis and magnetic resonance imaging findings of uterine adenomyosis with or without combined uterine leiomyomata underwent UAE. Self-perceived changes in clinical symptoms were assessed, and residual symptom severity and health-related quality of life (HRQOL) after UAE were evaluated. Clinical failure was defined as no symptomatic improvement or second invasive therapy after UAE. Results were stratified by the extent of uterine adenomyosis at baseline magnetic resonance imaging. Results: Patients were followed for a median of 40 months (range 5-102 months). UAE led to symptomatic control after UAE in 29 (72.5%) of 40 patients while 11 women underwent hysterectomy (n = 10) or dilatation and curettage (n = 1) for therapy failure. No significant difference between women with pure uterine adenoymosis and women with uterine adenomyosis combined with uterine leiomyomata was observed. Best results were shown for UAE in uterine adenomyosis with uterine leiomyomata predominance as opposed to predominant uterine adenomyosis with minor fibroid disease (clinical failure 0% vs. 31.5%, P = 0.058). Throughout the study group, HRQOL score values increased and symptom severity scores decreased after UAE. Least improvement was noted for women with pure adenomyosis. Conclusions: UAE is clinically effective in the long term in most women with uterine adenomyosis. Symptomatic control and HRQOL were highest in patients with combined disease of uterine adenomyosis but leiomyomata predominance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Infrarenal Abdominal Aortic Lesions With or Without Common Iliac Artery Involvement

To evaluate the results of stent placement for obstructive atherosclerotic aortic disease with or without involvement of the common iliac artery. Forty patients had self-expanding stents primarily or after balloon dilatation in the abdominal aorta between January 2005 and May 2011. All patients had trouble walking. Follow-up examinations were performed with clinical visits; these included color Doppler ultrasonography and computed tomographic angiography. Technical, clinical, and hemodynamic success was achieved in all patients. None of the patients underwent reintervention during the follow-up period, which ranged from 3 months to 6 years (median 24 months). Nine complications occurred in six patients. Of the nine complications, four were distal thromboembolisms, which were successfully treated with catheter-directed thrombolysis or anticoagulation therapy. Endovascular treatment of the obstructive aortic disease using self-expanding stents was safe and effective, with high technical success and long-term patency. Thromboembolic complications were high even though direct stenting was considered protective for thromboembolism formation. Particularly for infrarenal aortic stenosis, it can be recommended as the first-line treatment option for patients with obstructive atherosclerotic aortic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Center Experience and 1-Year Follow-up Results of 'Sandwich Technique' in the Management of Common Iliac Artery Aneurysms During EVAR

Purpose: Abdominal aortic aneurysm (AAA) accompanied by common iliac artery (CIA) aneurysms requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent-graft limb(s), a potential site of endoleak. The 'sandwich technique' is a procedure to increase EVAR feasibility in the setting of adverse or challenging CIA anatomy. Its main advantages include no restrictions in terms of CIA diameter or length or internal iliac artery (IIA) diameter, no need to wait for a specific stent-graft. Our purpose is to describe our single-center experience and one year follow-up results of this new procedure. Materials and Methods: From April 2009 to June 2010, the sandwich technique was performed in our institution in 7 patients treated for AAA and unilateral CIA aneurysms (n. 5) or bilateral CIA aneurysms (n. 2). Inclusion criteria were the presence of unilateral or bilateral CIA aneurysm (independently from its diameter), IIA artery measuring up to 9 mm in its maximum diameter, not dilatation of IIA and EIA. Results: The mean follow-up length was 15 months (range: 14-20 months). All stent-implanted iliac branches remained patent on 1 year follow-up and IIA flow was preserved. None of the patients had symptoms of pelvic ischemia. CT scan follow-up showed aneurysm shrinkage in five patients, without any sign of endoleaks in all cases. Conclusions: In selected cases, the 'sandwich technique' showed good outcomes confirming to be a safe and easy to perform way to overcome anatomical constraints and expanding the limits of EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is a Swine Model of Arteriovenous Malformation Suitable for Human Extracranial Arteriovenous Malformation? A Preliminary Study

Objective: A chronic arteriovenous malformation (AVM) model using the swine retia mirabilia (RMB) was developed and compared with the human extracranial AVM (EAVM) both in hemodynamics and pathology, to see if this brain AVM model can be used as an EAVM model. Methods: We created an arteriovenous fistula between the common carotid artery and the external jugular vein in eight animals by using end-to-end anastomosis. All animals were sacrificed 1 month after surgery, and the bilateral retia were obtained at autopsy and performed hematoxylin and eosin staining and immunohistochemistry. Pre- and postsurgical hemodynamic evaluations also were conducted. Then, the blood flow and histological changes of the animal model were compared with human EAVM. Results: The angiography after operation showed that the blood flow, like human EAVM, flowed from the feeding artery, via the nidus, drained to the draining vein. Microscopic examination showed dilated lumina and disrupted internal elastic lamina in both RMB of model and nidus of human EAVM, but the thickness of vessel wall had significant difference. Immunohistochemical reactivity for smooth muscle actin, angiopoietin 1, and angiopoietin 2 were similar in chronic model nidus microvessels and human EAVM, whereas vascular endothelial growth factor was significant difference between human EAVM and RMB of model. Conclusions: The AVM model described here is similar to human EAVM in hemodynamics and immunohistochemical features, but there are still some differences in anatomy and pathogenetic mechanism. Further study is needed to evaluate the applicability and efficacy of this model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predisposing Factors of Liver Necrosis after Transcatheter Arterial Chemoembolization in Liver Metastases from Neuroendocrine Tumor

PurposeTo investigate predictive factors for liver necrosis after transcatheter arterial chemoembolization (TACE) of neuroendocrine liver metastases.MethodsA total of 164 patients receiving 374 TACE were reviewed retrospectively to analyze predictive factors of liver necrosis. We analyzed patient age and sex; metastasis number and location; percentage of liver involvement; baseline liver function test; and pretreatment imaging abnormalities such as bile duct dilatation (BDD), portal vein narrowing (PVN), and portal vein thrombosis (PVT). We analyzed TACE technique such as Lipiodol or drug-eluting beads (DEB) as the drug’s vector; dose of chemotherapy; diameter of DEB; and number, frequency, and selectivity of TACE.ResultsLiver necrosis developed after 23 (6.1 %) of 374 TACE. In multivariate analysis, DEB > 300 μm in size induced more liver necrosis compared to Lipiodol (odds ratio [OR] 35.20; p < 0.0001) or with DEB < 300 μm in size (OR 19.95; p < 0.010). Pretreatment BDD (OR 119.64; p < 0.0001) and PVT (OR 9.83; p = 0.030) were predictive of liver necrosis. BDD or PVT responsible for liver necrosis were present before TACE in 59 % (13 of 22) and were induced by a previous TACE in 41 % (9 of 22) of cases.ConclusionDEB > 300 μm in size, BDD, and PVT are responsible for increased rate of liver necrosis after TACE. Careful analysis of BDD or PVT on pretreatment images as well as images taken between two courses can help avoid TACE complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Two Types of Double-J Ureteral Stents that Differ in Diameter and the Existence of Multiple Side Holes along the Straight Portion in Malignant Ureteral Strictures

PurposeThis study was decided to evaluate the impact of diameter and the existences of multiple side holes along the straight portion of double-J ureteral stents (DJUS) on early dysfunction of stents placed for malignant ureteral strictures.MethodsBetween April 2007 and December 2011, 141 DJUSs were placed via a percutaneous nephrostomy (PCN) tract in 110 consecutive patients with malignant ureteral strictures. 7F DJUSs with multiple side holes in the straight portion were placed in 58 ureters of 43 patients (Group 1). 8F DJUSs with three side holes in the proximal 2-cm of the straight portion were placed in 83 ureters of 67 patients (Group 2). The incidence of early DJUS dysfunction was compared between the two groups, and nephrostographic findings were evaluated in the cases of early dysfunction.ResultsEarly dysfunction of the DJUS was noted in 14 of 58 patients (24.1 %) in Group 1, which was significantly higher (p = 0.001) than in Group 2 in which only 1 of 83 patients (1.2 %) had early dysfunction of the DJUS. Nephrostographic findings of early dysfunction included dilatation of the pelvicalyceal system, filling defects in the ureteral stent, and no passage of contrast media into the urinary bladder.ConclusionsIn malignant ureteral strictures, multiple side holes in the straight portion of the 7-F DJUS seem to cause early dysfunction. The 8F DJUSs with three side holes in the proximal 2-cm of the straight portion may be superior at preventing early dysfunction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Recanalization of a Complete Lobar Bronchial Stenosis in a Lung Transplant Patient Using a Combined Percutaneous and Bronchoscopic Approach

Airway stenosis is a major complication after lung transplantation that is usually managed with a combination of interventional endoscopic techniques, including endobronchial debridement, balloon dilation, and stent placement. Herein, we report a successful case of recanalization of a complete stenosis of the right middle lobe bronchus in a lung transplant patient, by using a combined percutaneous–bronchoscopic approach after the failure of endobronchial debridement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Stenting for Portal Biliopathy with Jaundice

Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transluminal Angioplasty for Complete Membranous Obstruction of Suprahepatic Inferior Vena Cava: Long-Term Results

PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture and traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗