Search NASA⌕ Search

SEARCH · Search NASA

Results for “double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Online collection of LC effluent as droplets for automatic injection into ICP-MS

A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.

GPEC↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Deriving effective electrode–ion interactions from free-energy profiles at electrochemical interfaces

Understanding ion adsorption at electrified metal–electrolyte interfaces is essential for accurate modeling of electrochemical systems. Here, in this study, we systematically investigate the free energy profiles of Na + , Cl − , and F − ions at the Au(111)–water interface using enhanced sampling molecular dynamics with both classical force fields and machine-learned interatomic potentials (MLIPs). Our classical metadynamics results reveal a strong dependence of predicted ion adsorption on the Lennard-Jones parameters, highlighting that—without due care—standard mixing rules can lead to qualitatively incorrect descriptions of ion–metal interactions. We present a systematic methodology for tuning the cross term LJ parameters to control adsorption energetics in agreement with more accurate models. As a surrogate for an ab initio model, we employed the recently released Universal Models for Atoms MLIP, which validates classical trends and displays strong specific adsorption for chloride, weak adsorption for fluoride, and no specific adsorption for sodium, in agreement with experimental and theoretical expectations. By integrating molecular-level adsorption free energies into continuum models of the electric double layer, we show that specific ion adsorption substantially alters the interfacial ion population, the potential of zero charge, and the differential capacitance of the system. Our results underscore the critical importance of force field parameterization and advanced interatomic potentials for the predictive modeling of ion-specific effects at electrified interfaces and provide a robust framework for bridging molecular simulations and continuum electrochemical models.

Roncoroni, Fabrice [Lawrence Berkeley National Lab↗

Double-Pulsed 2-Micrometer Lidar Validation for Atmospheric CO2 Measurements

A double-pulsed, 2-micron Integrated Path Differential Absorption (IPDA) lidar instrument for atmospheric carbon dioxide (CO2) measurements is successfully developed at NASA Langley Research Center (LaRC). Based on direct detection technique, the instrument can be operated on ground or onboard a small aircraft. Key features of this compact, rugged and reliable IPDA lidar includes high transmitted laser energy, wavelength tuning, switching and locking, and sensitive detection. As a proof of concept, the IPDA ground and airborne CO2 measurement and validation will be presented. IPDA lidar CO2 measurements ground validation were conducted at NASA LaRC using hard targets and a calibrated in-situ sensor. Airborne validation, conducted onboard the NASA B-200 aircraft, included CO2 plum detection from power stations incinerators, comparison to in-flight CO2 in-situ sensor and comparison to air sampling at different altitude conducted by NOAA at the same site. Airborne measurements, spanning for 20 hours, were obtained from different target conditions. Ground targets included soil, vegetation, sand, snow and ocean. In addition, cloud slicing was examined over the ocean. These flight validations were conducted at different altitudes, up to 7 km, with different wavelength controlled weighing functions. CO2 measurement results agree with modeling conducted through the different sensors, as will be discussed.

Singh, Upendra N.↗

Enhancement of the NMSU Channel Error Simulator to Provide User-Selectable Link Delays

This is the third in a continuing series of reports describing the development of the Space-to-Ground Link Simulator (SGLS) to be used for testing data transfers under simulated space channel conditions. The SGLS is based upon Virtual Instrument (VI) software techniques for managing the error generation, link data rate configuration, and, now, selection of the link delay value. In this report we detail the changes that needed to be made to the SGLS VI configuration to permit link delays to be added to the basic error generation and link data rate control capabilities. This was accomplished by modifying the rate-splitting VIs to include a buffer the hold the incoming data for the duration selected by the user to emulate the channel link delay. In sample tests of this configuration, the TCP/IP(sub ftp) service and the SCPS(sub fp) service were used to transmit 10-KB data files using both symmetric (both forward and return links set to 115200 bps) and unsymmetric (forward link set at 2400 bps and a return link set at 115200 bps) link configurations. Transmission times were recorded at bit error rates of 0 through 10(exp -5) to give an indication of the link performance. In these tests. we noted separate timings for the protocol setup time to initiate the file transfer and the variation in the actual file transfer time caused by channel errors. Both protocols showed similar performance to that seen earlier for the symmetric and unsymmetric channels. This time, the delays in establishing the file protocol also showed that these delays could double the transmission time and need to be accounted for in mission planning. Both protocols also showed a difficulty in transmitting large data files over large link delays. In these tests, there was no clear favorite between the TCP/IP(sub ftp) and the SCPS(sub fp). Based upon these tests, further testing is recommended to extend the results to different file transfer configurations.

Horan, Stephen↗

Lunar and Planetary Science XXXVI, Part 20

The topics include: 1) Virtual Reality Technology as a Tool to Enhance Collaboration Between Space Exploration and Public Outreach: The Case Using the Mars Exploration Rover Images; 2) Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development; 3) Impact of Low Thermal Conductivity Layers on the Bulk Conductivity of a Martian Crustal Column; 4) Impacting Classroom Teachers Through Long-Term Professional Development; 5) Oxygen, Ca, and Ti Isotopic Compositions of Hibonite-bearing Inclusions; 6) Phenomenological Excitation Functions of Xe Isotopes with Protons on Nuclei of Cs, La and Ce; 7) Double-Diffusive Convection and Other Modes of Salinity-modulated Heat and Material Transport in Europa s Ocean; 8) Slope Morphologies of the Hellas Mensae Constructs, Eastern Hellas Planitia, Mars; 9) Development of Polygonal Thermal Contraction Patterns in a South Polar Trough, Mars 3 Years of Observations; 10) Martian Relevance of Dehydration and Rehydration in the Mg-Sulfate System; 11) Formation of Martian Volcanic Provinces by Lower Mantle Flushing? 12) Can Glasses Help Us to Unravel the Origin of Barred Olivine Chondrules? 13) Loki Patera: A Magma Sea Story; 14) Compositions of Partly Altered Olivine and Replacement Serpentine in the CM2 Chondrite QUE93005; 15) Model of Light Scattering by Lunar Regolith at Moderate Phase Angles: New Results; 16) Radiation Resistance of a Silicone Polymer Grease Based Regolith Collector for the HERA Near-Earth Asteroid Sample Return Mission; 17) Analysis of the Tectonic Lineaments in the Ganiki Planitia (V14) Quadrangle, Venus; 18) Nanometer-sized Diamonds from AGB Stars; 19) Quantifying Exact Motions Along Lineaments on Europa; 20) Geometry of Thrust Faults Beneath Amenthes Rupes, Mars; 21) Mapping of the Physical Characteristics and Mineral Composition of a Superficial Layer of the Moon or Mars and Ultra-Violet Polarimetry from the Orbital Station; 22) Negative Searches for Evidence of Aqueous Alteration on Asteroid Surfaces; 23) What Processes Have Shaped Basalt Boulders on Earth and Mars? Studies of Feature Persistence Using Facet Mapping and Fractal Analysis; 24) The Popigai Fluidizites: Dense Water Inclusions in Lechatelierite; Evidence for Shock-generated Carbonate and Hydrous Silicate Melts; 25) Missing Xenon Problem and Climate of the Early Earth; and 26) More on Magnetic Spectra from Correlated Crustal Sources on Mars

Source record↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH 2 ) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment. * Work supported by NASA Kennedy Space Center’s Science Mission Directorate Innovative Research and Development Fund.

Plasma↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH2) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment.

plasma↗

Gravitational physiology of human immune cells: a review of in vivo, ex vivo and in vitro studies

The study of the function of immune cells in microgravity has been studied for more than 20 years in several laboratories. It is clear today that the immune system is depressed in more than 50% of the astronauts during and after space flight and that the activation of T lymphocytes by mitogens in vitro changes dramatically. This article gives an overview of the gravitational studies conducted by our laboratory in Spacelab, in MIR station, in sounding rockets and on the ground in the clinostat and the centrifuge. Three experimental approaches are followed in our work: (i) Ex vivo studies are performed with blood samples drawn from astronauts; (ii) in vivo studies are based on the application of seven antigens to the skin of the astronauts; (iii) in vitro studies are carried out with immune cells purified from the blood of healthy donors (not astronauts). The data from our in vivo and ex vivo studies are in agreement with those of other laboratories and show that the immunological function is depressed in the majority of astronauts as a consequence of the stress of space flight rather than by a direct influence of gravity on the cell. Immune depression may become a critical hazard on long duration flights on space stations or to other planets. In vitro experiments show that cultures of free-floating lymphocytes and monocytes undergo a dramatic depression of activation by the mitogen concanavalin A, while activation is more than doubled when the cells are attached to microcarrier beads. Such effects may be attributed to both direct and indirect effects of gravitational unloading on basic biological mechanisms of the cell. While the in vitro data are very important to clarify certain aspects of the biological mechanism of T cells activation, they are not descriptive of the changes of the immunological function of the astronauts.

Review↗

Acridine orange staining reaction as an index of physiological activity in Escherichia coli

The assumption that the acridine orange (AO) color reaction may be used as an index of physiological activity was investigated in laboratory grown Escherichia coli. Spectrofluorometric observations of purified nucleic acids, ribosomes and the microscopic color of bacteriophage-infected cells stained with AO confirmed the theory that single-stranded nucleic acids emit orange to red fluorescence while those that are double-stranded fluoresce green in vivo. Bacteria growing actively in a rich medium could be distinguished from cells in stationary phase by the AO reaction. Cells from log phase appeared red, whereas those in stationary phase were green. However, this differentiation was not seen when the bacteria were grown in a minimal medium or when a variation of the staining method was used. Also, shifting bacteria in stationary phase to starvation conditions rapidly changed their AO staining reaction. Boiling and exposure to lethal concentrations of azide and formalin resulted in stationary-phase cells that appeared red after staining but bacteria killed with chlorine remained green. These findings indicate that the AO staining reaction may be suggestive of physiological activity under defined conditions. However, variables in staining and fixation procedures as well as uncertainties associated with mixed bacterial populations in environmental samples may produce results that are not consistent with the classical interpretation of this reaction. The importance of validating the putative physiological implications of this staining reaction is stressed.

NASA Discipline Number 04-10↗

Effects of thermomechanical processing on the microstructure and mechanical properties of Nb-1Zr-C alloys

A systematic study to evaluate the effects of thermomechanical processing on the microstructure and mechanical properties of Nb-1Zr alloy sheet containing 0.06 and 0.1 wt.%C (PWC-11) was conducted and compared to the results of Nb-1Zr. Coarse orthorhombic Nb2C precipitates were present in all the cast, extruded and cold rolled Nb-Zr samples containing C. After high temperature (greater than 0.5 T(sub m)) exposure (with or without applied stress), the Nb2C transforms to very fine and extremely stable FCC (Zr, Nb)C dispersoid, resulting in a highly creep resistant material. Only ZrO2 precipitates were found in Nb-1Zr. The creep strength of the 0.06C and the 0.1C carbide strengthened alloys were much superior to Nb-1Zr. At 1350 K the strength of the 0.06C alloy was about three times that of Nb-1Zr, while the 0.1C alloy had about five times the creep stress capability of Nb-1Zr. The tensile strength, long term creep strength, and stability of the microstructure of the PWC-11 sheet appear to be independent of the number of 1900 K extrusions performed prior to cold rolling. The microhardness of these single, double and triple extnided PWC-11 sheets also were comparable. The tensile strength of PWC-11 and Nb-1Zr at room temperature and 1350 K were comparable.

Titran, Robert H.↗

Long-Term Photovoltaic System Performance in Cold, Snowy Climates

As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize northern and alpine communities due to their scalability and affordability. However, a barrier to large-scale adoption of PV in cold climates is long-term performance uncertainty under snowfall, freeze-thaw cycles, low temperatures, and high winds. In this work, we provide a comprehensive review of published silicon degradation rates in cold Koppen-Geiger climate classifications of Dfb (humid continental), Dfc (subarctic), and ET (tundra). We first analyze the system degradation rates of three subarctic ground-mounted photovoltaic sites in North America using the RdTools year-on-year method: an Al-BSF double-axis tracking site in Fairbanks, Alaska (65degrees N); a PERC and silicon heterojunction bifacial vertical and south-tilted site in Fairbanks, Alaska; and a PERC south-facing fixed-tilt site in Fort Simpson, Northwest Territories (62degrees N). Degradation rates of these newly analyzed sites vary between -0.4%/year and -1.5%/year. Combining these data with previously reported cold climate degradation rates, we show that the distribution of cold climate degradation peaks at -0.1%/year to -0.2%/year but has a large tail with rates above -0.5%/year. The average reported cold climate degradation rate is -0.45%/year, whereas the median value is -0.33%/year. These results suggest that despite frequent freeze-thaw cycles and potential exposure to high wind and snow loads, PV systems in cold climates tend to degrade slower than PV systems in warmer climates. The limited sample size of reported degradation rates in cold climates (27) motivates the need for further data acquisition and monitoring efforts as new technologies are deployed.

14 SOLAR ENERGY↗

Instrumentation for vector electric field measurements from DE-B

Instrumentation has been developed, using the symmetric double-floating probe technique, to make vector electric field measurements from the low-altitude Dynamics Explorer (DE-B) spacecraft. Six 11-m cylindrical antennas are deployed along three orthogonal axes to form the sensor array. The outer two meters of each element are used as sensors, which results in a baseline of 21.4 m for the dc measurement for each axis. Efforts have been made to provide straight antennas and antennas that will not bend from thermal stresses as sun angles are changed. Measurements of the dc electric field will be made 16 times/sec or every half-kilometer along the orbit. Sensitivity will be 0.1 mV/m with a range of + or - 1 V/m. A 20-channel comb filter spectrometer will monitor ac electric fields, concentrating on frequencies below 1 kHz. Electric fields from any single axis or two axes may be sampled by the spectrometer within the range of 1 microvolt/m to 10 mV/m

Maynard, N. C.↗

Study of the effects of MeV Ag, Cu, Au, and Sn implantation on the optical properties of LiNbO3

The authors present the results of characterization of linear absorption and nonlinear refractive index of Au, Ag, Cu and Sn ion implantation into LiNbO3. Ag was implanted at 1.5 MeV to fluences of 2 to 17 x 17(exp 16)/sq cm at room temperature. Au and Cu were implanted to fluences of 5 to 20 x 10(exp 16)/sq cm at an energy of 2.0 MeV. Sn was implanted to a fluence of 1.6 x 10(exp 17)/sq cm at 160 kV. Optical absorption spectrometry indicated an absorption peak for the Au implanted samples after heat treatment at 1,000 C at approx. 620 nm. The Ag implanted samples absorption peaks shifted from approx. 450 nm before heat treatment to 550 nm after 500 C for 1h. Heat treatment at 800 C returned the Ag implanted crystals to a clear state. Cu nanocluster absorption peaks disappears at 500 C. No Sn clusters were observed by optical absorption or XRD. The size of the Ag and Au clusters as a function of heat treatment were determined from the absorption peaks. The Ag clusters did not change appreciably in size with heat treatment. The Au clusters increased from 3 to 9 nm diameter upon heat treatment at 1000 C. TEM analysis performed on a Au implanted crystal indicated the formation of Au nanocrystals with facets normal to the c-axis. Measurements of the nonlinear refractive indices were carried out using the Z-scan method with a tunable dye laser pumped by a frequency doubled mode-locked Nd:YAG laser. The dye laser had a 4.5 ps pulse duration time and 76 MHz pulse repetition rate (575 nm).

Williams, E. K.↗

New infrared objects associated with OH masers

Results of a search for IR radiation at 10 microns from a sample of OH maser sources are reported. An IR source is discovered near each of six OH masers which emit mainly at 1612 MHz in two distinct velocity ranges. It is shown that all the sources have varied with time, that two sources have exhibited significant variations in color temperature, and that the energy distributions of the six objects over the spectral range from 2 to 20 microns fall into two categories. Absorption in the 2.3-micron band of CO is detected in two sources, and four are found to display substantial silicate absorption features. The energy distributions of the sources indicate that pumping by 35-micron photons is feasible, but 2.8-micron pumping is very unlikely; the distributions are best explained as emission from very thick dust shells at temperatures of about 500 K. The data are taken as supporting the hypothesis that every double-peaked OH maser emitting principally at 1612 MHz is associated with an IR object. The nature of the objects inside the dust shells and their evolutionary state are briefly discussed.

Evans, N. J., II↗

Hydrogen Fire in a Storage Vessel

On October 23, 2007, the operations team began a procedure to sample the Liquid Hydrogen (LH2) storage vessels ("tanks"), and associated transfer system. This procedure was being performed to determine the conditions within the system, and if necessary, to purge the system of any excess Gaseous Hydrogen (GH2) in preparation for reactivation of the system. The system had not been used since 2003. The LH2 storage system contains two (2) spherical pressure vessels of 225,000 gallons in volume, with a maximum working pressure (MAWP) of 50 psig. Eight inch transfer piping connects them to the usage point. Operations began with activation of the burnstack for the LH2 storage area. Pneumatic (GN2) systems in the storage area were then activated and checked. Pressurization of storage tank number 1 with gaseous nitrogen (GN2) was initiated, with a target pressure of 10 psig, at which point samples were planned to be taken. At 5 psig, a loud noise was heard in the upper area of tank number 2. Smoke was seen exiting the burnstack and from the insulation on vent lines for both tanks. At this time tank number 1 was vented and the pressurization system was secured. The mishap resulted in physical damage to both storage tanks, as well as to some of the piping for both tanks. Corrective action included repair of the damaged hardware by a qualified contractor. Preventive action included documented organizational policy and procedures for establishing standby and mothball conditions for facilities and equipment, including provisions as detailed in the investigation report recommendations: Recommendation 1: The using organization should define necessary activities in order to place hydrogen systems in long term periods of inactivity. The defined activities should address requirements for rendering inert, isolation (i.e., physical disconnect, double block and bleed, etc.) and periodic monitoring. Recommendation 2: The using organization should develop a process to periodically monitor hazardous systems for proper configuration (i.e., a daily/weekly/monthly check sheet to verify critical purges are active).

Hester, Zena M.↗

Interpreting Broad Double-Peaked Emission Lines in Active Galactic Nuclei

The principal objectives of this project were to probe the inner regions of active galactic nuclei and to test general relativity in the strong-field limit. The approach takes advantage of broad atomic line emission observed from material deep in the potential well of an active galactic nucleus which contains key information as to the physics of the system. Line profiles in a wide range of wavebands from optical to X-ray have provided compelling evidence of the existence of a relativistic accretion disk around a supermassive black hole in a number of galaxies. The simplest model posits a geometrically thin disk in Keplerian orbit, with general relativistic effects in evidence. This model is the point of departure for the proposed work. We developed a high-performance numerical code to calculate photon trajectories in a Schwarzschild or Kerr metric and implemented it on parallel supercomputers. This code includes a general purpose ray tracer that calculates line profiles, light curves, and other observable quantities for a wide variety of emitter configurations. The versatility comes from the fact that the ray tracing algorithm does not depend on any symmetries regarding emitter locations. The speed comes from parallel implementation which enables us to sample hitherto unattainable volumes of disk model parameter space. During the period 1 March 1997 through 28 February 1998, two papers, supported in whole or in part by this grant, were published in refereed journals. They are reproduced in their entirety in the next two sections of this report.

Halpern, Jules↗