Effect of B20 and Low Aromatic Diesel on Transit Bus NOx Emissions Over Driving Cycles with a Range of Kinetic Intensity
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Synonymous codons occur with different frequencies in different organisms, a phenomenon termed codon usage bias. Codon optimization, a common term for a variety of approaches used widely by the biopharmaceutical industry, involves synonymous substitutions to increase protein expression. It had long been presumed that synonymous variants, which, by definition, do not alter the primary amino acid sequence, have no effect on protein structure and function. However, a critical mass of reports suggests that synonymous codon variations may impact protein conformation. To investigate the impact of synonymous codons usage on protein expression and function, we designed an optimized coagulation factor IX (FIX) variant and used multiple methods to compare its properties to the wild-type FIX upon expression in HEK293T cells. We found that the two variants differ in their conformation, even when controlling for the difference in expression levels. Using ribosome profiling, we identified robust changes in the translational kinetics of the two variants and were able to identify a region in the gene that may have a role in altering the conformation of the protein. Our data have direct implications for codon optimization strategies, for production of recombinant proteins and gene therapies.
The kidney is a major drug-eliminating organ. Renal impairment or concomitant use of transporter inhibitors may decrease active secretion and increase exposure to a drug that is a substrate of kidney secretory transporters. However, prediction of the effects of patient factors on kidney transporters remains challenging because of the multiplicity of transporters and the lack of understanding of their abundance and specificity. The objective of this study was to use physiologically based pharmacokinetic (PBPK) modelling to evaluate the effects of patient factors on kidney transporters. Methods Models for three renally cleared drugs (oseltamivir carboxylate, cidofovir and cefuroxime) were developed using a general PBPK platform, with the contributions of net basolateral uptake transport (T up,b ) and apical efflux transport (T eff,a ) being specifically defined. Results and Conclusion We demonstrated the practical use of PBPK models to: (1) define transporter-mediated renal secretion, using plasma and urine data; (2) inform a change in the system-dependent parameter (C10-fold reduction in the functional ‘proximal tubule cells per gram kidney’) in severe renal impairment that is responsible for the decreased secretory transport activities of test drugs; (3) derive an in vivo, plasma unbound inhibition constant of T up,b by probenecid (B1 lM), based on observed drug interaction data; and (4) suggest a plausible mechanism of probenecid preferentially inhibiting T up,b in order to alleviate cidofovir-induced nephrotoxicity.
Terahertz (THz) external-cavity lasers based on quantum-cascade (QC) metasurfaces are emerging as widely-tunable, single-mode sources with the potential to cover the 1--6 THz range in discrete bands with milliwatt-level output power. By operating on an ultra-short cavity with a length on the order of the wavelength, the QC vertical-external-cavity surface-emitting-laser (VECSEL) architecture enables continuous, broadband tuning while producing high quality beam patterns and scalable power output. The methods and challenges for designing the metasurface at different frequencies are discussed. As the QC-VECSEL is scaled below 2 THz, the primary challenges are reduced gain from the QC active region, increased metasurface quality factor and its effect on tunable bandwidth, and larger power consumption due to a correspondingly scaled metasurface area. At frequencies above 4.5 THz, challenges arise from a reduced metasurface quality factor and the excess absorption that occurs from proximity to the Reststrahlen band. The results of four different devices — with center frequencies 1.8 THz, 2.8 THz, 3.5 THz, and 4.5 THz — are reported. Each device demonstrated at least 200 GHz of continuous single-mode tuning, with the largest being 650 GHz around 3.5 THz. The limitations of the tuning range are well modeled by a Fabry-Pérot cavity which accounts for the reflection phase of the metasurface and the effect of the metasurface quality factor on laser threshold. Lastly, the effect of different output couplers on device performance is studied, demonstrating a significant trade-off between the slope efficiency and tuning bandwidth.
Determining Confounding Sensitivities In Eddy Current Thin Film Measurements Ethan Gros, Lalita Udpa, Electrical Engineering, Michigan State University, East Lansing MI 48824 James A. Smith, Experiment Analysis, Idaho National Laboratory, Idaho Falls ID 83415 Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It is the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy current testing is performed using a commercially available, hand held eddy current probe (ETA3.3H spring loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe is sent to a hand held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring loaded eddy probe is at measuring film thickness under varying experimental conditions. This research will study the effects of a number of factors such as i) calibration, ii) conductivity, iii) edge effect, iv) surface finish of base material and v) cable condition and compare with the long term reproducibility of a standard measurement. This work was performed with support from the Department of Energy under the United States National Nuclear Security Administration (NNSA) at the Idaho National Laboratory.
Spectroscopic factors to low-lying negative-parity states in Be 11 extracted from the B 12 ( d , He 3 ) Be 11 proton-removal reaction are interpreted within the rotational model. Earlier predictions of the p -wave proton-removal strengths in the strong-coupling limit of the Nilsson model underestimated the spectroscopic factors to the 3 / 2 1 - and 5 / 2 1 - states and suggested that deviations in the 1 + ground state of the odd-odd B 12 due to Coriolis coupling should be further explored. Furthermore, in this work we use the particle rotor model to take into account these effects and obtain a good description of the level scheme in B 11 , with a moderate K mixing of the proton Nilsson levels [110]1/2 and [101]3/2. This mixing, present in the 1 + bandhead of B 12 , is key to explaining the proton-pickup data.
This study was carried out to investigate the chemopreventive potentials of plant originated glycoprotein (UDN glycoprotein, 116 kDa) isolated from the stems of Ulmus davidiana Nakai (UDN) on aberrant crypt foci (ACF) formation in 1,2-dimethylhydrazine (DMH)-treated ICR mice. UDN glycoprotein was administered to mice at 0.01% and 0.02% levels for 5 weeks. The mice were treated with 20 mg/kg DMH twice a week for 2 weeks in presence of UDN glycoprotein and killed at week 6. We found that UDN glycoprotein has inhibitory effects on the frequency of colonic aberrant crypt foci (ACF), activation of colonic proliferating cell nuclear antigen (PCNA), and release of plasma lactate dehydrogenase (LDH) in DMH-treated mice. In addition, UDN glycoprotein has anti-oxidative effects on the formation of plasma thiobarbituric acid reactive substances (TBARS) and the production of plasma inducible nitric oxide (NO) in DMH-treated mouse. Also, 0.02% UDN glycoprotein suppressed the DNA binding activities of nuclear factor-kappa B (NF-{kappa}B) and activator protein-1 (AP-1), accompanying the inhibitions of its subunits (p50, p65, c-Jun, and c-Fos), pro-inflammatory proteins [inducible nitric oxide synthase (iNOS), and cyclooxygenase-2 (COX-2)], and pro-inflammatory cytokines [tumor necrosis factor (TNF)-{alpha} and interleukin (IL)-6] on DMH-stimulated ACF formation. On the basis of these results, we assume that UDN glycoprotein may be useful for colon cancer prevention at initiation stage.
The effects of indoor environmental conditions on human health, satisfaction, and performance have been the focal point of research for decades. This paper reviews and summarizes the impact of lighting environment on task performance, specifically for the built environment audience. Existing studies included a variety of performance tests on cognitive performance and perception, visual acuity and reaction, memory, reasoning, and labor productivity. Illuminance, luminance ratio and correlated color temperature were found to affect performance in different ways, reflecting the impact of experimental techniques, conditions, performance evaluation methods used and data analysis methods. These were reviewed and categorized, with discussion on limitations related to sample size, modeling approach, carryover effects and other factors affecting individual differences in performance, with recommendations for future improvement. Although no universal conclusions can be made, in general, task performance seems to improve with higher illuminances, contrast ratios in the range of 7–11:1 (while always making sure that glare will not occur in the space) and higher correlated color temperature, while spectral tuning in the red or blue wavelengths has also shown positive effects. To obtain more generic evidence, future studies should be more consistent in terms of experimental procedures and overall light conditions, and also consider the effects of vertical illuminance, daylight provision/control, and outside views on task performance. Finally, studying performance with multi-factorial designs in a human-centered optimized manner (such as deploying variable lighting scenarios optimized for various tasks) can lead to deeper understanding of lighting effects on task performance, and ultimately to improved lighting design and operation in buildings overall.
Purpose: Prospective data are lacking on long-term morbidity of inguinal lymphadenectomy including the influence of extent of surgery, use of radiotherapy, and patient factors. The aim of this study is to evaluate the effects of these factors on patient outcome, quality of life (QOL), regional symptoms, and limb volumes after inguinal or ilio-inguinal lymphadenectomy for melanoma. Methods: Analysis of the subgroup of patients with inguinal lymph node field relapse of melanoma, treated by inguinal or ilio-inguinal lymphadenectomy in the ANZMTG/TROG randomized trial of adjuvant radiotherapy versus observation. Results: Sixty-nine patients, 46 having undergone inguinal and 23 ilio-inguinal lymphadenectomy, with median follow-up of 73 months were analyzed. Mean limb volume increased rapidly after surgery (7% by 3 months) and continued to increase for at least another 18 months. Patients with body mass index (BMI) ≥ 25 kg/m{sup 2} had greater limb volume increase than normal-weight patients (13.3% versus 6.9%, P = 0.030). QOL improved over the first 18 months, but despite initial improvement, regional symptoms persisted long term. Type of surgery (inguinal or ilio-inguinal lymphadenectomy) had no demonstrably significant effect on limb volume (9.9% versus 13.4%, P = 0.35), QOL (P = 0.68), or regional symptoms (P = 0.65). There was no difference in overall survival between inguinal and ilio-inguinal lymphadenectomy [hazard ratio (HR) 0.75, 95% confidence interval (CI) 0.40–1.40, P = 0.43]. Conclusions: Inguinal lymphadenectomy for melanoma is a potentially morbid procedure with significant increases in limb volume. Patients report reasonable QOL but may have ongoing regional symptoms. Overweight/obesity is associated with poorer QOL, increased limb volume, and regional symptoms.
Microbial enzyme-mediated soil organic matter (SOM) decomposition regulates many key ecosystem functions, such as elemental cycling, soil carbon sequestration, and soil fertility. However, representing microbial processes in Earth system models (ESMs) remains challenging due to a limited understanding of the spatial patterns of diverse microbial functions responsible for soil carbon (C), nitrogen (N), and phosphorus (P) cycling as well as the underlying mechanisms regulating their relative abundances across various environments. We collected published metagenomics data across the continental US (CONUS) to identify hundreds of microbial genes involved in soil C, N, and P cycling and grouped them into eight enzyme functional classes (EFCs). Each EFC represented a group of gene-encoded potential enzymes that decompose similar soil compounds. By integrating the abundances of omics-informed EFCs with the corresponding environmental information, we trained a machine learning (ML) model to identify key edaphic, climate, and vegetation factors regulating the abundances of each EFC. Quantitative analysis of effects of these factors revealed that the spatial distribution of eight EFCs for soil C, N, and P cycling across CONUS reflected potential resource optimization strategies of microbial communities under nutrient limitation, preferential organic-mineral associations, and climatological stresses. This insight, together with the interpreted ML tool and the CONUS-level benchmark for EFCs abundances, paves the way for parameterizing environmental-regulated microbial functional dynamics in biogeochemical models.
The amyloid deposition in the form of extracellular fibrillar aggregates of amyloid-β (Aβ) peptide is a critical pathological event in Alzheimer’s disease. Here, we report a systematic investigation of the effects of environmental factors on the kinetics of Aβ fibrillization in vitro. The effects of Aβ42 peptide concentration, temperature, pH, added solvents and the ratio of Aβ40 and Aβ42 on the peptide fibrillization under agitated conditions was studied. The analysis show that the rate of fibril growth by monomer addition is not limited by diffusion but by rearrangement in the monomer structure, which is enhanced by low concentrations of fluorinated alcohols and characterized by the activation energy of 12 kcal/mol. Fibrillization rate decreases at pH values below 7.0 where simultaneous protonation of His 13 and 14 inhibits fibril formation. The lag period for Aβ42 was only twofold shorter and the fibril growth rate twofold faster than those of Aβ40. Lag period was shortened and the fibrillization rate was increased only at 90% content of Aβ42.
The exchange enhancement of the electron g factor in strained InGaAs/InP heterostructures with a two-dimensional electron gas is studied. Analysis of the temperature dependence of the resistance in the minima of the Shubnikov-de Haas oscillations in perpendicular magnetic fields up to 12 T in the vicinity of the odd filling factors of the Landau levels yields the values of the effective electron Lande factor g* from −8.6 to −10.1. The experimental values are compared with the results of theoretical calculations of the g factor of quasiparticles. The calculations are performed using an eight-band k · p Hamiltonian and take into account exchange interaction in the two-dimensional electron gas. It is shown that, under the conditions of a large overlap between the spin-split Landau levels, the maximum value of the quasiparticle g factor can be attained in the vicinity of even filling factors. This is caused by the nonparabolicity of the electron dispersion relation.
This article reviews the experiences of 63 case studies of small businesses (<250 employees) with manufacturing automation equipment acquired through a health/safety intervention grant program. The review scope included equipment technologies classified as industrial robots (n = 17), computer numerical control (CNC) machining (n = 29), or other programmable automation systems (n = 17). Descriptions of workers' compensation (WC) claim injuries and identified risk factors that motivated the acquisition of the equipment were extracted from grant applications. Other aspects of the employer experiences, including qualitative and quantitative assessment of effects on risk factors for musculoskeletal disorders (MSD), effects on productivity, and employee acceptance of the intervention were summarized from the case study reports. Case studies associated with a combination of large reduction in risk factors, lower cost per affected employee, and reported increases in productivity were CNC stone cutting system, CNC/vertical machining system, automated system for bottling, CNC/routing system for plastics products manufacturing, and a CNC/Cutting system for vinyl/carpet. Six case studies of industrial robots reported quantitative reductions in MSD risk factors in these diverse manufacturing industries: snack foods; photographic film, paper, plate, and chemical; machine shops; leather goods and allied products; plastic products; and iron and steel forging. Furthermore, this review of health/safety intervention case studies indicates that advanced (programmable) manufacturing automation, including industrial robots, reduced workplace musculoskeletal risk factors, and improved process productivity in most cases.
Two procedures for facilitation of line tracing and deciphering of complicated spectra of electron paramagnetic resonance (EPR) were developed: a correction of microwave frequencies for every orientation of external magnetic field on the base of known values of g-tensor components for a reference paramagnetic center and followed rectification of measured angular dependences using plots of effective deviation of g{sup 2}-factors of observed lines from effective g{sup 2}-factors of the reference center versus angles or squared cosines of angles describing magnetic field orientations. Their application to EPR spectra of nearly stoichiometric lithium niobate crystals doped with neodymium allowed identifying two axial and six different low-symmetry Nd{sup 3+} centers, to determine all components of their g-tensors, and to propose common divacancy models for a whole family of Nd{sup 3+} centers.
We have revisited the effect of hadronic form factors in kaon photoproduction process by utilizing an isobaric model developed for kaon photoproduction off the proton. The model is able to reproduce the available experimental data nicely as well as to reveal the origin of the second peak in the total cross section, which was the main source of confusion for decades. Different from our previous study, in the present work we explore the possibility of using different hadronic form factors in each of the KΛN vertices. The use of different hadronic form factors, e.g. dipole, Gaussian, and generalized dipole, has been found to produce a more flexible isobar model, which can provide a significant improvement in the model.
Purpose: To validate a radiographic simulation in order to estimate patient dose due to clinically-used radiography protocols. Methods: A Monte Carlo simulation was created to simulate a radiographic x-ray beam using GEANT4. Initial validation was performed according to a portion of TG 195. Computational NURBS-based phantoms were used simulate patients of varying ages and sizes. The deposited energy in the phantom is output by the simulation. The exposure in air from a clinically used radiography unit was measured at 100 cm for various tube potentials. 10 million photons were simulated with 1 cubic centimeter of air located 100 cm from the source, and the total absorbed dose was noted. The normalization factor was determined by taking a ratio of the measured dose in air to the simulated dose in air. Dose to individual voxels is calculated using the energy deposition map along with the voxelized and segmented phantom and the normalization factor. Finally, the effective dose is calculated using the ICRP methodology and tissue weighting factors. Results: This radiography simulation allows for the calculation and visualization of the energy deposition map within a voxelized phantom. The ratio of exposure, measured using an ionization chamber, to air in the simulation was determined. Since the simulation output is calibrated to match the exposure of a given clinical radiographic x-ray tube, the dose map may be visualized. This will also allow for absorbed dose estimation in specific organs or tissues as well as a whole body effective dose estimation. Conclusion: This work indicates that our Monte Carlo simulation may be used to estimate the radiation dose from clinical radiographic protocols. This will allow for an estimate of radiographic dose from various examinations without the use of traditional methods such as thermoluminescent dosimeters and body phantoms.
Direct detection dark matter experiments are increasingly interested in the low-mass dark matter parameter space, but zero-background low-mass searches require event separation between the electron and nuclear recoil bands, which requires a proper understanding of detector energy reconstruction. Previous simulations have shown that we do not entirely understand the ionization efficiency (yield) for electron and nuclear recoils, as the assumption that the distribution for the yield is normally distributed for a true recoil energy is violated. Since the yield distribution may directly affect dark matter low-mass limits, it is crucial we understand how the yield is distributed. A component to understanding the yield distribution is the variance in the number of electron-hole pairs produced or ionization variance. This effect has been studied relatively infrequently as experiments have been interested in large energy deposits (10 - 100 keV) and could accurately separate electron and nuclear recoil events. For electron recoils, the ionization variance is described by a “Fano” factor. For nuclear recoils the effect can be parameterized by an “effective” Fano factor, which has similar definition but a different physical origin. The nuclear recoil “effective” Fano factor is shown to be much larger than the electron-recoil version above around 10 keV deposited energy.
Purpose: We aimed to estimate the optimal proportion of all gynecological cancers that should be treated with brachytherapy (BT)-the optimal brachytherapy utilization rate (BTU)-to compare this with actual gynecological BTU and to assess the effects of nonmedical factors on access to BT. Methods and Materials: The previously constructed inter/multinational guideline-based peer-reviewed models of optimal BTU for cancers of the uterine cervix, uterine corpus, and vagina were combined to estimate optimal BTU for all gynecological cancers. The robustness of the model was tested by univariate and multivariate sensitivity analyses. The resulting model was applied to New South Wales (NSW), the United States, and Western Europe. Actual BTU was determined for NSW by a retrospective patterns-of-care study of BT; for Western Europe from published reports; and for the United States from Surveillance, Epidemiology, and End Results data. Differences between optimal and actual BTU were assessed. The effect of nonmedical factors on access to BT in NSW were analyzed. Results: Gynecological BTU was as follows: NSW 28% optimal (95% confidence interval [CI] 26%-33%) compared with 14% actual; United States 30% optimal (95% CI 26%-34%) and 10% actual; and Western Europe 27% optimal (95% CI 25%-32%) and 16% actual. On multivariate analysis, NSW patients were more likely to undergo gynecological BT if residing in Area Health Service equipped with BT (odds ratio 1.76, P=.008) and if residing in socioeconomically disadvantaged postcodes (odds ratio 1.12, P=.05), but remoteness of residence was not significant. Conclusions: Gynecological BT is underutilized in NSW, Western Europe, and the United States given evidence-based guidelines. Access to BT equipment in NSW was significantly associated with higher utilization rates. Causes of underutilization elsewhere were undetermined. Our model of optimal BTU can be used as a quality assurance tool, providing an evidence-based benchmark against which actual patterns of practice can be measured. It can also be used to assist in determining the adequacy of BT resource allocation.