At least 487 records · Page 27

An Approach for Utilizing Power Flow Modeling for Simulations of Hybrid Electric Propulsion Systems

This paper describes an approach to creating simulations of the electric components for a hybrid electric propulsionsystem. The proposed modeling technique is based on power/load flow modeling and is designed to provide a modularframework that includes buses, lines, and other electrical components that can be connected together to form the electrical distribution system. The purpose of this paper is to detail an electric distribution system modeling technique and to demonstrate how these models may be integrated with turbomachinery simulations. These general modeling techniques were created to be utilized for system and control design studies. Additionally, steady-state and dynamic performance for a proposed model example is compared with data from a hardware in the loop simulation.

Power Flow↗

Sensing The Position Of A Piston In A Cylinder

Position of piston in cylinder determined by series of ports and pressure-actuated electrical switches. Position-sensing scheme developed to help control movement of piston, which delivers fist-size objects to automatic mechanism at rate of less than 1 per second. Piston driven by either pressurized gas or hydraulic fluid. Position sensors have only fluid connections to cylinder. If cylinder or piston removed, not necessary to disturb electrical connections to switches. Scheme useful when electrical sensors create hazard or cause interference.

Wiker, Gordon A.↗

Reconfigurable Electrical Networks within a Conductive Hydrogel Composite

Soft materials that exhibit compliance, programmability, and reconfigurability can have a transformative impact as electronic skin for applications in wearable electronics/soft robotics. There has been significant progress in soft conductive materials; however, achieving electrically controlled and reversible changes in conductivity and circuit connectivity remains challenging. To overcome this limitation, a soft material architecture with reconfigurable conductive networks of silver flakes embedded within a hydrogel matrix is presented. The conductive networks can be reversibly created/disconnected through various stimuli, including current, humidity, or temperature. Such stimuli affect electrical connectivity of the hydrogel by controlling its water content, which can be modulated by evaporation under ambient conditions (passive dehydration), evaporation through electrical Joule heating (active dehydration), or absorption of additional water (rehydration). The resulting change in electrical conductivity is reversible and repeatable, endowing the composite with on-demand reconfigurable conductivity. To highlight this material's unique properties, it is shown that conductive traces can be reconfigured after severe damage and revert to lower conductivity after rehydration. Additionally, a quadruped robot is demonstrated that can respond to stimuli by changing direction following exposure to excess water, thereby achieving reprogrammable locomotion behaviors.

36 MATERIALS SCIENCE↗

Series-Connected Vapor/Vapor AMTEC Cells

Size and weight reduced; operating lifetime increased. Developmental alkali-metal thermal-to-electric converter (AMTEC) in which cells fed from common supply of high-pressure sodium vapor and connected electrically in series. No liquid sodium makes contact with any part of AMTEC cells. Sodium vapor supplied to solid electrolyte of each cell through porous metal anode on upstream side. Proposed design reduces need for high-temperature feedthroughs in that cells internally connected. Power withdrawn through feedthrough at lower temperature without significant thermal loss.

Underwood, Mark L.↗

Optical Energy Transfer and Conversion System

An optical power transfer system comprising a fiber spooler, a fiber optic rotary joint mechanically connected to the fiber spooler, and an electrical power extraction subsystem connected to the fiber optic rotary joint with an optical waveguide. Optical energy is generated at and transferred from a base station through fiber wrapped around the spooler, through the rotary joint, and ultimately to the power extraction system at a remote mobility platform for conversion to another form of energy.

Stone, William C.↗

Electrostatic energy harvester

An electrostatic energy harvester broadly comprises an electrical energy storage component, an electrical energy transfer stage, first and second variable capacitors, and a switching control module. The electrical energy transfer stage includes diode-connected transistors and dictates electrical energy transfer between the electrical energy storage component and the variable capacitors. The switching control module timely switches between the first and second variable capacitors according to a state machine. Subsequent electrical energy investments from the electrical energy storage component are less than an initial electrical energy investment due to remnant electrical energy remaining at the previously active one of the first and second variable capacitors from previous electrical energy harvesting.

Wilson, Amy Charlene↗

Electrostatic energy harvester

An electrostatic energy harvester broadly comprises an electrical energy storage component, an electrical energy transfer stage, first and second variable capacitors, and a switching control module. The electrical energy transfer stage includes diode-connected transistors and dictates electrical energy transfer between the electrical energy storage component and the variable capacitors. The switching control module timely switches between the first and second variable capacitors according to a state machine. Subsequent electrical energy investments from the electrical energy storage component are less than an initial electrical energy investment due to remnant electrical energy remaining at the previously active one of the first and second variable capacitors from previous electrical energy harvesting.

Wilson, Amy Charlene↗

Electrostatic energy harvester

An electrostatic energy harvester broadly comprises an electrical energy storage component, an electrical energy transfer stage, first and second variable capacitors, and a switching control module. The electrical energy transfer stage includes diode-connected transistors and dictates electrical energy transfer between the electrical energy storage component and the variable capacitors. The switching control module timely switches between the first and second variable capacitors according to a state machine. Subsequent electrical energy investments from the electrical energy storage component are less than an initial electrical energy investment due to remnant electrical energy remaining at the previously active one of the first and second variable capacitors from previous electrical energy harvesting.

Wilson, Amy Charlene↗

The Spacelab Experiment Interface Device (SEID)

The Spacelab experiment interface device (SEID) is described which simulates the electrical, and logical connections of the Spacelab remote acquisition unit (RAU), the interface functions of the Spacelab experiment computer software, and the electrical aspects of the high rate multiplexer. Simulated RAU interfaces include PCM serial channels (up to four), user time clock (UTC), flexible inputs (up to 128) and discrete outputs (up to 64). Connectors are logically compatible with the rau. be instructed to execute sequences of input/output commands to the RAU, similar to those performed during flight. This approximation of the experiment computer software is adequate to detect interface problems and prevent these from occurring during Spacelab payload integration. The SEID hardware is a microprocessor based system, utilizing an 8085 microprocessor with 6K of PROM and 4K of static RAM. The basic unit is augmented with an LSI-11 microcomputer to provide disk storage and a more dynamic environment for generation of control data. A simulation of the general monitoring loop is provided to emulate Spacelab system timing.

Kallus, R.↗

Field Verification of Grid-Forming Inverter-Based Power Plant Performance for Transmission System Reliability

This report describes some examples of the operation of two grid-forming (GFM) inverter-based photovoltaic-battery hybrid power plants connected to the electric system of the island of Kauai in Hawaii. Both plants are photovoltaic power plants with battery energy storage and are connected to the networked transmission system operated by Kauai Island Utility Cooperative (KIUC), along with several other power plants including an oil-fired plant, diesel generators, small hydroelectric plants, a biofuel plant, and several other photovoltaic plants.

14 SOLAR ENERGY↗

High thermal power density heat transfer

Heat from a high temperature heat pipe is transferred through a vacuum or a gap filled with electrically nonconducting gas to a cooler heat pipe. The heat pipe is used to cool the nuclear reactor while the heat pipe is connected thermally and electrically to a thermionic converter. If the receiver requires greater thermal power density, geometries are used with larger heat pipe areas for transmitting and receiving energy than the area for conducting the heat to the thermionic converter. In this way the heat pipe capability for increasing thermal power densities compensates for the comparatively low thermal power densities through the electrically non-conducting gap between the two heat pipes.

Morris, J. F.↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

Electrical double layers at the oil/water interface

This review presents the historical development and current status of the theory of the electrical double layer at a liquid/liquid interface. It gives rigorous thermodynamic definitions of all basic concepts related to liquid interfaces and to the electrical double layer. The difference between the surface of a solid electrode and the interface of two immiscible electrolyte solutions (ITIES) is analyzed in connection to their electrical properties. The most important classical relationships for the electrical double layer are presented and critically discussed. The generalized adsorption isotherm is derived. After a short review of the classical Gouy-Chapman and Verwey-Niessen models, more recent developments of the double layer theory are presented. These include effects of variable dielectric permittivity, nonlocal electrostatics, hydration forces, the modified Poisson-Boltzmann equation and the ion-dipole plasma. The relative merits of different theories are estimated by comparing them with computer simulation of the ITIES and electrical double layer. Special attention is given to the structure of ITIES and its variation due to adsorption of ions and amphiphilic molecules.

Non-NASA Center↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

STS-88 Day 05 Highlights

On this fifth day of the STS-88 mission, the flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei Krikalev are awakened with the song "Jerry the Rigger," in honor of Mission Specialist Jerry Ross. Ross and Newman are then seen being readied for the first EVA. This space walk, which will last 6-1/2 hours, will focus on connecting computer and electrical cables between Unity, the two mating adapters attached to either end of Unity, and Zarya. In all, Ross and Newman will make about 40 connections during the spacewalk. This will enable power to flow to Unity for the first time in orbit and will permit Unity's avionics, computers and heaters to be activated.

Source record↗

Illumination control apparatus for compensating solar light

An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.

Owens, L. J.↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Conductive Bands Diminish Electrostatic Discharges

Electrostatic discharges on surfaces covered with electrically insulating paints reduced by connecting edges of painted surfaces to electrical grounds with band of conductive material. Prevents charge build up on paint which eventually arcs to conductive surface, damaging structures and equipment.

Leung, Philip L.↗