Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences

Purpose: To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. Patients and Methods: A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1w flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. Results: The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). Conclusions: The MR-Sim setup and automatic sCT generation methods using standard MR sequences generates realistic contours and electron densities for prostate cancer radiation therapy dose planning and digitally reconstructed radiograph generation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of elemental composition of shale rocks by laser induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) is used for elemental characterization of outcrop samples from the Marcellus Shale. Powdered samples were pressed to form pellets and used for LIBS analysis. Partial least squares regression (PLS-R) and univariate calibration curves were used for quantification of analytes. The matrix effect is substantially reduced using the partial least squares calibration method. Predicted results with LIBS are compared to ICP-OES results for Si, Al, Ti, Mg, and Ca. As for C, its results are compared to those obtained by a carbon analyzer. Relative errors of the LIBS measurements are in the range of 1.7 to 12.6%. The limits of detection (LODs) obtained for Si, Al, Ti, Mg and Ca are 60.9, 33.0, 15.6, 4.2 and 0.03 ppm, respectively. An LOD of 0.4 wt.% was obtained for carbon. Finally, this study shows that the LIBS method can provide a rapid analysis of shale samples and can potentially benefit depleted gas shale carbon storage research.

58 GEOSCIENCES↗

Results from the HARP Experiment

Hadron production is a key ingredient in many aspects of {nu} physics. Precise prediction of atmospheric {nu} fluxes, characterization of accelerator {nu} beams, quantification of {pi} production and capture for {nu}-factory designs, all of these would profit from hadron production measurements. HARP at the CERN PS was the first hadron production experiment designed on purpose to match all these requirements. It combines a large, full phase space acceptance with low systematic errors and high statistics. HARP was operated in the range from 3 GeV to 15 GeV. We briefly describe here the most recent results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FEDERATED LEARNING ON STOCHASTIC NEURAL NETWORKS

Federated learning is a machine learning paradigm that leverages edge computing on client devices to optimize models while maintaining user privacy by ensuring that local data remain on the device. However, since all data are collected by clients, federated learning is susceptible to latent noise in local datasets. Factors such as limited measurement capabilities or human errors may introduce inaccuracies in client data. To address this challenge, we propose the use of a stochastic neural network as the local model within the federated learning framework. Stochastic neural networks not only facilitate the estimation of the true underlying states of the data but also enable the quantification of latent noise. We refer to our federated learning approach, which incorporates stochastic neural networks as local models, as federated stochastic neural networks. In this work we will present numerical experiments demonstrating the performance and effectiveness of our method, particularly in handling nonindependent and identically distributed data.

97 MATHEMATICS AND COMPUTING↗

Bayesian Uncertainty Quantification in Predictions of Flows in Highly Heterogeneous Media and Its Applications to the CO 2 Sequestration

In this proposal, we have worked on Bayesian uncertainty quantification for predictions of fows in highly heterogeneous media. The research in this proposal is broad and includes: prior modeling for heterogeneous permeability fields; effective parametrization of heterogeneous spatial priors; efficient ensemble- level solution techniques; efficient multiscale approximation techniques; study of the regularity of complex posterior distribution and the error estimates due to parameter reduction; efficient sampling techniques; applications to multi-phase ow and transport. We list our publications below and describe some of our main research activities. Our multi-disciplinary team includes experts from the areas of multiscale modeling, multilevel solvers, Bayesian statistics, spatial permeability modeling, and the application domain.

97 MATHEMATICS AND COMPUTING↗

Evaluating Bay Area Methane Emission Inventory

As a regulatory agency, evaluating and improving estimates of methane (CH4) emissions from the San Francisco Bay Area is an area of interest to the Bay Area Air Quality Management District (BAAQMD). Currently, regional, state, and federal agencies generally estimate methane emissions using bottom-up inventory methods that rely on a combination of activity data, emission factors, biogeochemical models and other information. Recent atmospheric top-down measurement estimates of methane emissions for the US as a whole (e.g., Miller et al., 2013) and in California (e.g., Jeong et al., 2013; Peischl et al., 2013) have shown inventories underestimate total methane emissions by ~ 50% in many areas of California, including the SF Bay Area (Fairley and Fischer, 2015). The goal of this research is to provide information to help improve methane emission estimates for the San Francisco Bay Area. The research effort builds upon our previous work that produced methane emission maps for each of the major source sectors as part of the California Greenhouse Gas Emissions Measurement (CALGEM) project (http://calgem.lbl.gov/prior_emission.html; Jeong et al., 2012; Jeong et al., 2013; Jeong et al., 2014). Working with BAAQMD, we evaluate the existing inventory in light of recently published literature and revise the CALGEM CH4 emission maps to provide better specificity for BAAQMD. We also suggest further research that will improve emission estimates. To accomplish the goals, we reviewed the current BAAQMD inventory, and compared its method with those from the state inventory from the California Air Resources Board (CARB), the CALGEM inventory, and recent published literature. We also updated activity data (e.g., livestock statistics) to reflect recent changes and to better represent spatial information. Then, we produced spatially explicit CH4 emission estimates on the 1-km modeling grid used by BAAQMD. We present the detailed activity data, methods and derived emission maps by sector. In total, we estimate the anthropogenic emissions for BAAQMD to be 116.4 Gg (1 Gg = 109 g) CH4/yr, with a likely uncertainty of ~ 50% or more (e.g., NRC, 2010; US-EPA, 2015). Including the emissions from wetland (Jeong et al., 2013), the total CH4 emission estimate for BAAQMD is 120.1 Gg CH4/yr. Table 1 summarizes the estimated CH4 emissions for 2011 by sector. The sectors were categorized following those that are used in recent regional emission quantification studies (e.g., Jeong et al., 2013; Peischl et al., 2013; Wecht et al., 2014). However, we note that this result is marginally lower than the top-down estimate of 240 ± 60 Gg CH4/yr (at 95% confidence) reported by Fairley and Fischer (2015), suggesting some combination of systematic error in the top-down estimate, underestimation of emissions from known sources, or as yet unidentified sources may be present. With respect to the relative contributions from different source sectors, the CH4 emissions from the region are dominated by urban activities. Landfill emissions represent 53% of the District’s total emission followed by livestock (16%) and natural gas (15%). These three dominant sectors account for 84% of the total anthropogenic emission in BAAQMD. This suggests that mitigation efforts need to focus on these three sources. Figure 1 shows the gridded anthropogenic CH4 emissions on the BAAQMD’s 1-km grid. In general, the spatial pattern of emissions follows the density of population while strong point sources are also distributed in the rural areas of the District. Detailed methods and emissions for each sector and county are described in the following sections.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Quantification of Expected Time-of-Arrival in UAV Flight Trajectory

One of the foremost requirements for accurate in-flight safety monitoring of autonomous unmanned aerial vehicles (UAVs) is tracking of their flight trajectory. Existing UAVs leverage autonomous flight functionalities based on trajectory generation algorithms developed in robotic applications such as polynomial or spline curves in order to facilitate kinematic smoothness, minimum vibrations and fuel efficiency. However in practice, the actual path may be subjected to unexpected local weather conditions, unexpected obstacles along the path or abrupt traffic changes in the low-altitude airspace resulting in large errors of the predicted time-of-arrival at way-points. In this study, an approach to quantify and propagate uncertainty in 4D trajectories is proposed. The paper presents a simple error interval propagation method based on the expected cruise speed of the UAV and its associated uncertainty. The uncertainty is then propagated in time to estimate reasonable confidence intervals on the times-of-arrival of the vehicle at each way-point as well as along the entire flight-path. The uncertainty propagation is demonstrated on a state-of-the-art trajectory generation algorithm based on non-uniform rational B-spline (NURBS) curves. Further, the effect of a stationary wind field is incorporated in the uncertainty propagation approach. The proposed method is implemented on synthetic and real data obtained from flight experiments with a small UAV.

Uncertainty Quantification↗

Discrimination and quantification of Fe and Ni abundances in Genesis solar wind implanted collectors using X-ray standing wave fluorescence yield depth profiling with internal referencing

In this paper, X-ray standing wave fluorescence yield depth profiling was used to determine the solar wind implanted Fe and Ni fluences in a silicon-on-sapphire (SoS) Genesis collector (60326). An internal reference standardization method was developed based on fluorescence from Si and Al in the collector materials. Measured Fe fluence agreed well with that measured previously by us on a sapphire collector (50722) as well as SIMS results by Jurewicz et al. Measured Ni fluence was higher than expected by a factor of two; neither instrumental errors nor solar wind fractionation effects are considered significant perturbations to this value. Impurity Ni within the epitaxial Si layer, if present, could explain the high Ni fluences and therefore needs further investigation. As they stand, these results are consistent with minor temporally-variable Fe and Ni fractionation on the timescale of a year.

36 MATERIALS SCIENCE↗

HIFiRE Flight 2 Unstart Reliability Analysis

The objective of this work was to assess the unstart reliability of the HIFiRE Flight 2 system. To do this, a quantification of margins and uncertainties framework was used for comparing model predictions of the predicted combustion induced shock location to the predicted last stable shock location within the isolator. Uncertainty sources included parametric uncertainty in the flight conditions, the heat release model, and turbulence modeling, as well as model verification errors. Additionally, an estimate of model-form uncertainty was established by comparing the model to measured ground test data. A computationally efficient non-intrusive polynomial chaos approach was used to propagate parametric uncertainty through the computational flu-ids dynamics models of both the ground test configuration and the flight vehicle. Compared to direct-connect ground test data, computational fluid dynamics predictions yielded about two duct heights of model-form uncertainty. This was applied to a prediction of flight vehicle unstart margin at the Mach 6.5 flight condition. Building up all of the computational model uncertainty, including parametric uncertainty, verification errors, and the determined model-form uncertainty, a 95% probability level based confidence ratio, or a ratio of total uncertainty to a statistical margin measure, was found to be 0.31 for the flight system.

Thomas K West↗

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗

Calibrating hypersonic turbulence flow models with the HIFiRE-1 experiment using data-driven machine-learned models.

In this paper we study the efficacy of combining machine-learning methods with projection-based model reduction techniques for creating data-driven surrogate models of computationally expensive, high-fidelity physics models. Such surrogate models are essential for many-query applications e.g., engineering design optimization and parameter estimation, where it is necessary to invoke the high-fidelity model sequentially, many times. Surrogate models are usually constructed for individual scalar quantities. However there are scenarios where a spatially varying field needs to be modeled as a function of the model’s input parameters. Here we develop a method to do so, using projections to represent spatial variability while a machine-learned model captures the dependence of the model’s response on the inputs. The method is demonstrated on modeling the heat flux and pressure on the surface of the HIFiRE-1 geometry in a Mach 7.16 turbulent flow. The surrogate model is then used to perform Bayesian estimation of freestream conditions and parameters of the SST (Shear Stress Transport) turbulence model embedded in the high-fidelity (Reynolds-Averaged Navier–Stokes) flow simulator, using shock-tunnel data. The paper provides the first-ever Bayesian calibration of a turbulence model for complex hypersonic turbulent flows. We find that the primary issues in estimating the SST model parameters are the limited information content of the heat flux and pressure measurements and the large model-form error encountered in a certain part of the flow.

42 ENGINEERING↗

A framework to collect human reliability analysis data for nuclear power plants using a simplified simulator and student operators

Data scarcity in human reliability analysis (HRA) has been a major challenge in the quantification process. Many institutes have collected HRA data through experiments using full-scope simulators with actual operators. Nevertheless, there are still some limitations to relying solely on full-scope studies. This paper aims to propose how full-scope data collection studies can be supported through the Simplified Human Error Experimental Program (SHEEP). The SHEEP framework was developed by Idaho National Laboratory (INL) to collect HRA data through a simplified simulator and student operators. This paper introduces the major tasks in the SHEEP framework, with a particular focus on differences that arise due to participant type (i.e., student vs. actual operator), based on experiments using a simplified simulator (i.e., the Rancor Microworld). This paper also describes whether the data collected via this approach could support a representative full-scope data collection study (i.e., the HuREX study) based on the experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Efforts Organizing WPNCS SG-8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks

The Working Party on Nuclear Criticality Safety (WPNCS) under the guidance of the Organization for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) has over 20 years of experience addressing concerns related to static and transient configurations encountered within the nuclear fuel cycle: fuel fabrication, transportation, reprocessing, storage, and geological disposal. One of the cornerstone activities of the WPNCS is the International Criticality Safety Benchmark Evaluation Project (ICSBEP), which was established to identify a comprehensive set of criticality benchmark data, evaluate the data, including quantification of overall uncertainties; compile the data into a standardized format, perform sample calculations utilizing modern nuclear data sets and codes utilized in nuclear criticality safety, and formally document the work into a single source of verified benchmark data. Annually, members of the ICSBEP Technical Review Group (TRG) contribute evaluated benchmark data that undergoes comprehensive technical review prior to publication in the ICSBEP Handbook. In the years since the ICSBEP was established, there has been much work to prepare benchmark data to support validation activities in nuclear criticality safety. The 2020 edition of the ICSBEP Handbook contains acceptable benchmark specifications for 5,053 critical, subcritical, or near-critical configurations in 582 benchmark evaluations. Modern benchmark development benefits from decades of experienced international participants, a well-established handbook format, supplementary guides to deal with uncertainty quantification, and a comprehensive review process based upon independent reviews from international experts. The ICSBEP Handbook also contains 838 configurations deemed unacceptable to support criticality safety efforts. They are recorded, with the reasoning for their rejection, to preserve the experimental data, prevent reevaluation of data that are incomplete or contain known errors, and/or to potentially allow future reevaluation of the experiment pending the identification of sufficient data to resolve identified inconsistencies and errors. Users of the ICSBEP Handbook today might notice that the rigor and quality of modern criticality safety benchmarks is much greater than those prepared within the initial decade of the project. Benchmarks with 1s uncertainties in k eff greater than 1% were traditionally rejected unless they were identified as unique experiment types that encompassed materials, fuels, or designs not available from other benchmark experiments. However, benchmarks developed using modern experimental techniques and practices typically have uncertainties on the order of a few tenths of a percent. There have been ongoing efforts to improve the overall quality of previously published benchmark evaluations. Seventy-eight evaluations, containing approximately 600 configurations, have been revised just within the past decade. An additional eleven benchmarks are under revision for updated release in the 2020 edition of the ICSBEP Handbook. If some of the historic benchmarks were resubmitted in their current form to the TRG today, they would be rejected due to lack of data, missing components in the uncertainty analysis, or incomplete benchmark model development. The use of historic criticality safety benchmarks that underestimate the total uncertainty, lack properly quantified biases, or provide inadequate benchmark specifications do not sufficiently support modern criticality safety and nuclear data efforts. Although the ICSBEP Handbook is recognized by regulating bodies to support criticality safety, users are required to justify their reasons to ignore historic benchmark data and include additional safety margins within their designs. Discussions were held at the WPNCS 23rd Annual Meeting in September 2019 regarding the aforementioned issues. The resultant decision was to establish Subgroup 8 (SG-8): Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks. The current activities of SG-8 are discussed herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying Transient Uncertainty in the BEAVRS Benchmark Using Time Series Analysis Methods

Advances in computation have brought about significant improvements in creating fast-running high-fidelity simulations of nuclear cores. The BEAVRS benchmark is a highly-detailed PWR specification with two cycles of measured operational data used to validate high-fidelity core analysis methods. This PWR depletion benchmark captures the fine details of the LWR fuel assemblies, burnable absorbers, in-core fission detectors, core loading and shuffling patterns. Specifically, 58 of the 193 assemblies contain in-core detectors with measurements taken over 61 axial positions every month. These detectors are U-235 fission chambers with slightly varying mass of U-235. The collected signals are normalized on a given assembly permitting full core comparisons. The fuel layout for cycle 1 and instrument tube locations for the reactor are given in figures 1 and 2 respectively. Through a series of data processing and comparisons, it was shown that axially integrated radial maps of reaction rates were in close agreement between provided detector data and calculated data. More recently, the focus of the BEAVRS project has been on quantifying uncertainty to further assess the validity of aforementioned results. A close investigation of sources of error shows that uncertainties from operational nuclear data arise primarily from data measurements and processing. While the errors in axial realignment and interpolation seem significant, these sources affect only a small subset of data points near grid spacers and do not persist throughout the entire core. Instead, measurement uncertainty from detector count rates and radial integration dominate the uncertainty in measured data are determined as the most significant sources of error. This uncertainty analysis treated each given burnup step as independent of comparable data at neighboring burnup steps. More recent work has been targeted at understanding how reaction rates vary over time, in order to determine whether calculated reaction rates follow any observable trends. This abstract hones in on transient uncertainty quantification, in order to compare observed data against models for transient behavior. The first section of the paper uses linear regression tools to fit operational data, while the latter portion of the paper explores more complex simulation tools to fit operational data. Ultimately, the BEAVRS benchmark aims to serve as a true non-proprietary international benchmark for the validation of high-fidelity tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

Application of Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Monitoring carbon dioxide (CO2) concentration within a spacecraft or spacesuit is critically important to ensuring the safety of the crew. Carbon dioxide uniquely absorbs light at wavelengths of 3.95 micrometers and 4.26 micrometers. As a result, non-dispersive infrared (NDIR) spectroscopy can be employed as a reliable and inexpensive method for the quantification of CO2 within the atmosphere. A multitude of commercial-off-the-shelf (COTS) NDIR sensors exist for CO2 quantification. The COTS sensors provide reasonable accuracy so long as the measurements are attained under conditions close to the calibration conditions of the sensor (typically 21.1 C and 1 atm). However, as pressure deviates from atmospheric to the pressures associated with a spacecraft (8.0-10.2 PSIA) or spacesuit (4.1-8.0 PSIA), the error in the measurement grows increasingly large. In addition to pressure and temperature dependencies, the infrared transmissivity through a volume of gas also depends on the composition of the gas. As the composition is not known a priori, accurate sub-ambient detection must rely on iterative sensor compensation techniques. This manuscript describes the development of recursive compensation algorithms for sub-ambient detection of CO2 with COTS NDIR sensors. In addition, the basis of the exponential loss in accuracy is developed theoretically considering thermal, Doppler, and Lorentz broadening effects which arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. As a result, this manuscript provides an approach to employing COTS sensors at sub-ambient conditions and may also lend insight into designing future NDIR sensors for aerospace application.

Swickrath, Michael J.↗