Search NASA⌕ Search

SEARCH · Search NASA

Results for “facility development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Fuel Fabrication and Single Stage Aqueous Process Modeling

The Material Protection, Accounting, and Control Technologies program utilizes modeling and simulation to assess Material Control and Accountability (MC&A) concerns for a variety of nuclear facilities. Single analyst tools allow for rapid design and evaluation of advanced approaches for new and existing nuclear facilities. A low enriched uranium (LEU) fuel conversion and fabrication facility simulator is developed to assist with MC&A for existing facilities. Measurements are added to the model (consistent with current best practices). Material balance calculations and statistical tests are also added to the model. In addition, scoping work is performed for developing a single stage aqueous reprocessing model. Preliminary results are presented and discussed, and next steps outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Workflows for Science: A comprehensive guide for ensemble workflow tools usage with applications on OLCF systems

The growing demand for robust computational and workflow environments for scientific applications and user communities at the Oak Ridge Leadership Computing Facility (OLCF) has prompted collaboration with ensemble tools development teams and facility users to produce this technical paper. We connect science applications to the RADICAL-Pilot (RP) workflow tool to execute ensemble instantiations using the Frontier supercomputer. The documented installation, usage, and execution demonstrates how RP streamlines scientific workflows at OLCF. We outline the specific steps OLCF users can follow to integrate this tool with their applications and advance their research. This document stands as a comprehensive guide to OLCF users of ensemble workflow tools with examples on real applications using the Frontier supercomputer.

97 MATHEMATICS AND COMPUTING↗

Investigation of scour adjacent to submerged geotextiles used for shore protection

This study presents the results of an experimental investigation of morphology change in the vicinity of submerged geotextiles placed within the surf zone. The study was motivated by the emerging use of submerged geotextile tubes for shore protection, shoreline stabilization, and surf amenity enhancement and the need to understand the mechanisms responsible for scour in the vicinity of these structures to preserve their structural integrity and reduce their structural failure. A movable bed physical model experiment was conducted at the U.S. Army Engineer Research and Development Center’s Large-scale Sediment Transport Facility (LSTF) to develop empirical formulations to predict the mean scour depth adjacent to geotextiles under oblique wave-breaking conditions as a function of the maximum Keulegan-Carpenter, Shields, and Reynolds numbers. The observed scour in the vicinity of the geotextiles was also compared to a previous study of scour in the vicinity of submerged cylinders. Formulations developed by Cataño-Lopera and García (2006) relating the Keulegan-Carpenter, Shields, and Reynolds numbers to the scour depth were used to predict the scour observed during the LSTF experiment. Results show that the formulations of Cataño-Lopera and García (2006) over-predict the observed scour when calculated using the maximum Keulegan-Carpenter, Shields, and Reynolds numbers. New, modified expressions of Cataño-Lopera and García (2006) were developed for use in oblique random wave fields.

Gorton, Alicia M.↗

Plutonium Pit Production - Savannah River Site (Plutonium Pit Production Mission)

The Savannah River Site (SRS) has been providing strategic materials to maintain the U.S. nuclear deterrent for 70 years. Establishing plutonium pit production capabilities at SRS will leverage existing infrastructure at the site and optimize use of the talented workforce in the region to meet validated national security requirements. This new mission will require a large skilled workforce for decades to come. Savannah River Nuclear Solutions LLC, the management and operating (M&O) partner at SRS, has established teams for both the transition of the Mixed Oxide (MOX) Fuel Fabrication Facility and the development of the proposed Savannah River Plutonium Processing Facility (SRPPF). In addition, NNSA remains committed to safely and securely removing surplus plutonium from South Carolina in a timely and cost-effective manner by using the dilute and dispose method.

Source record↗

Demonstrate FARM supervisory capabilities for a thermal energy storage problem for the DETAIL facility: IES Simulation Ecosystem Control System Development

The goal of the power dispatch problem for an Integrated Energy System (IES) is to adjust the power output and the heat flow of each component to maximize the profitability of the whole unit. Facilities that can integrate real-time digital signals, mock nuclear power, thermal energy storage and industrial heat use via high-temperature electrolysis were constructed at INL to support the research activities. The Dynamic Energy Technology and Integration Laboratory (DETAIL) houses the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET) and the Thermal Energy Distribution System (TEDS). In this report, the hierarchical control system architecture proposed in June 2023 milestone for the flexible operation of DETAIL facility is finalized and demonstrated. A brief description of the components and the corresponding Dymola models from the HYRBID repository is first provided. Then, the current control strategy is presented. In particular, the approach for generating the set-point trajectories to be fed to the PI controllers is analyzed, and its limits were identified. To preserve safe operation over both long-time and real-time horizons, the integration of a Supervisory Control layer embedding a modified version of FARM (Feasible Actuator Range Modifier) module is proposed. FARM is a component of the RAVEN-based FORCE framework designed to support HERON module at optimizing the operation of IES units. The proposed control system for DETAIL foresees FARM to be applied twice, i.e., the original version (“FARM-Validator”) aiding the solution of the power dispatch problem, and a modified version (“FARM-Supervisory”) coordinating the PID controllers. Despite the kernel of the two modules is the same, their tasks are quite different. The former intervenes at the beginning of each hour to prevent constraint violations over long time periods, the latter addresses real-time control tasks and monitors the response of constrained variables at a much finer time resolution. A tentative procedure for training the embedded Digital Twins with the experimental data is also proposed. Finally, the capabilities of the designed architecture and the impact of the added Supervisory Control layer are demonstrated by simulating a representative power dispatch scenario.

25 ENERGY STORAGE↗

Vacuum System and Modeling for the Materials Plasma Exposure Experiment

Understanding the science of plasma-material interactions (PMI) is essential for the future development of fusion facilities. The design of divertors and first walls for the next generation of long-pulse fusion facilities, such as a Fusion Nuclear Science Facility (FNSF) or a DEMO, requires significant PMI research and development. In order to meet this need, a new linear plasma facility, the Materials Plasma Exposure Experiment (MPEX) is proposed, which will produce divertor relevant plasma conditions for these next generation facilities. The device will be capable of handling low activation irradiated samples and be able to remove and replace samples without breaking vacuum. A Target Exchange Chamber (TEC) which can be disconnected from the high field environment in order to perform in-situ diagnostics is planned for the facility as well. The vacuum system for MPEX must be carefully designed in order to meet the requirements of the different heating systems, and to provide conditions at the target similar to those expected in a divertor. An automated coupling-decoupling (“autocoupler”) system is designed to create a high vacuum seal, and will allow the TEC to be disconnected without breaking vacuum in either the TEC or the primary plasma materials interaction chamber. This autocoupler, which can be actuated remotely in the presence of the high magnetic fields, has been designed and prototyped, and shows robustness in a variety of conditions. The vacuum system has been modeled using a simplified finite element analysis, and indicates that the design goals for the pressures in key regions of the facility are achievable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Economic Development Impacts in Colorado from Four Vestas Manufacturing Facilities, Wind Powering America Fact Sheet Series

This case study summarizes the economic development benefits to Colorado from four Vestas manufacturing facilities: one in Windsor, two in Brighton, and one in Pueblo (which is planned to be the world's largest tower-manufacturing facility). In the midst of an economic slowdown during which numerous U.S. manufacturers have closed their doors, wind energy component manufacturing is one U.S. industry that has experienced unprecedented growth during the past few years. As demand for wind power in the United States has increased and transportation costs have increased around the world, states have seen a significant increase in the number of manufacturers that produce wind turbine components in the United States. Vestas' Colorado operations will bring approximately $700 million in capital investment and nearly 2,500 jobs to the state.

17 WIND ENERGY↗

A Monte Carlo Technique to Estimate Emissions from R&D Facilities

The Pacific Northwest National Laboratory (PNNL) operates multidisciplinary laboratory Research and Development (R&D) facilities for the U. S. Department of Energy and sampled air chemical emissions from some of these facilities from 1998 until 2008. Although sampling was not required for environmental compliance, PNNL conducted sampling to provide data to compare estimated release fractions to those used for emissions estimates and to verify that methods used to determine compliance with air regulations and permits conservatively predict actual emissions. Sampling also identifies and quantifies air toxics emitted to compare with compliance limits established by the State. The sampling data provides a unique opportunity to quantify emissions and investigate factors potentially impacting emissions. Previous work using this data set include a paper by Woodruff, Benar, and McCarthy1 who summarized the compliance approach used by PNNL and described sampling and analytical measurements for the first sampling campaigns. Conclusions reported in the paper were that none of the measurements of the target compounds exceeded a State acceptable source impact level (ASIL)2 even using significant overestimation factors, and that an average release fraction calculated from the data provided reasonable validation of the factor used in compliance assessments. Other reports using the data include the following: • A metric was developed by Ballinger, Duchsherer, and Metoyer3 to compare chemical signatures. The analysis found similarities in chemical signatures from three of the buildings but a markedly different signature from the fourth building. • A method was developed and used on the data to rank the chemical compounds that present the greatest risk to a potential downstream receptor and to determine whether the sampling parameters and detection limits provided sufficient resolution to verify compliance at potential receptor locations.4 • The stack data from one of the buildings was analyzed using a statistical technique called Positive Matrix Factorization (PMF) to identify the number and composition of major contributing sources to measured stack concentrations.5 In this analysis, a method is described that uses a Monte Carlo technique to produce a distribution of emission estimates from the measured data. The method is applied to one of the chemicals previously identified as more significant than others using the ranking process.4 Variations on the method are investigated and compared to determine their effects on the emission estimates.

Laboratory, air chemical emissions, volatile organ↗

STATUS OF SRF FACILITIES AT SNS

The Spallation Neutron Source (SNS) has recognized the need for developing in-house capability to ensure long term sustainability of the superconducting linac (SCL). SNS has made substantial gains in the last 6 years in understanding SCL operation, including system and equipment limiting factors, and resolution of system and equipment issues. Significant effort and focus is required to assure on-going success in the operation, maintenance, and improvement of the SCL and to address the requirements of the upgrade project for the Second Target Station. These interdependent efforts include implementation of demonstrated improvements, fabrication of spare cryomodules, cavity R&D to enhance machine performance, and related SRF facility developments. Cryomodule and vertical cavity testing facilities are being developed to demonstrate process capabilities and to further understand the collective limitations of installed cavities. The status and future plans for SRF facilities at SNS will be presented.

Kim, Sang-Ho↗

Developing a high-flux, high-energy continuum backlighter for extended x-ray absorption fine structure measurements at the National Ignition Facility

Extended X-ray absorption fine structure (EXAFS) spectroscopy is a powerful tool for in situ characterization of matter in the high energy density regime. An EXAFS platform is currently being developed on the National Ignition Facility. Development of a suitable X-ray backlighter involves minimizing the temporal duration and source size while maximizing spectral smoothness and brightness. One approach involves imploding a spherical shell, which generates a high-flux X-ray flash at stagnation. Furthermore we present results from a series of experiments comparing the X-ray source properties produced by imploded empty and Ar-filled capsules.

47 OTHER INSTRUMENTATION↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Proceedings of the 1998 International Computational Accelerator Physics Conference

The 1998 International Computational Accelerator Physics Conference, ICAP’98, was held September 14-18, 1998, at the Monterey Convention Center in Monterey, California. The meeting continued the tradition of four earlier Computational Accelerator Physics conferences, held in La Jolla, California (1988), Los Alamos, New Mexico (1990), Pleasanton, California (1993), and Williamsburg, Virginia (1996). ICAP’98 was organized by the Stanford Linear Accelerator Center (SLAC), Los Alamos National Laboratory (LANL), and the National Energy Research Scientific Computing Center (NERSC), and received support from the U.S. Department of Energy. The aim of this conference series is to discuss recent advances in Computational Accelerator Physics and their applications to solving important problems related to present and future accelerators. The ICAP’98 program included plenary sessions on modeling challenges in next-generation accelerators, state-of-the art methods in computational accelerator physics, and a view of what high-end computing would be like in the 21st century. There were also focused sessions on accelerator design and control, modeling high intensity beam phenomena, electromagnetic modeling, advanced algorithms, software environments and libraries, visualization and graphic interfaces, modeling advanced accelerator concepts, modeling the beam-beam interaction, computing wakefields, and combined particle/field simulations. In addition to these oral sessions there was a poster session and a vendor display. Prior to the start of the technical program, a half-day tutorial on High Performance Computing was hosted by NERSC. The ICAP series recognizes that computing and, in particular, advanced computing, is playing an increasingly important role in the successful design and development of major accelerator facilities, and in research and development leading to advances in accelerator technology. We expect that this new emphasis on high-end computing will continue in future ICAP conferences.

Ko, Kwok↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

The Use of Underground Research Laboratories to Support Repository Development Programs. A Roadmap for the Underground Research Facilities Network.

Under the auspices of the International Atomic Energy Agency (IAEA), nationally developed underground research laboratories (URLs) and associated research institutions are being offered for use by other nations. These facilities form an Underground Research Facilities (URF) Network for training in and demonstration of waste disposal technologies and the sharing of knowledge and experience related to geologic repository development, research, and engineering. In order to achieve its objectives, the URF Network regularly sponsors workshops and training events related to the knowledge base that is transferable between existing URL programs and to nations with an interest in developing a new URL. This report describes the role of URLs in the context of a general timeline for repository development. This description includes identification of key phases and activities that contribute to repository development as a repository program evolves from an early research and development phase to later phases such as construction, operations, and closure. This information is cast in the form of a matrix with the entries in this matrix forming the basis of the URF Network roadmap that will be used to identify and plan future workshops and training events.

MacKinnon, Robert J.↗

Mach-Zehnder recording systems for pulsed power diagnostics

Fiber-optic transmission and recording systems, based on Mach-Zehnder modulators, have been developed and installed at the National Ignition Facility (NIF), and are being developed for other pulsed-power facilities such as the Z accelerator at Sandia, with different requirements. We present the design and performance characteristics for the mature analog links, based on the system developed for the Gamma Reaction History diagnostic at the OMEGA laser and at NIF. For a single detector channel, two Mach-Zehnders are used to provide high dynamic range at the full recording bandwidth with no gaps in the coverage. We present laboratory and shot data to estimate upper limits on the radiation effects as they impact recorded data quality. Finally, we will assess the technology readiness level for mature and developing implementations of Mach-Zehnder links for these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-Neutron Irradiated BOR60 Sample Preparation and Characterization: Nuclear Science User Facility 2017 Milestone Report

This document outlines the results obtained by Oak Ridge National Laboratory (ORNL) in collaboration with the University of Michigan-led Consolidated Innovative Nuclear Research project, “Feasibility of combined ion-neutron irradiation for accessing high dose levels.” In this reporting period, neutron irradiated were prepared and shipped to the University of Michigan for subsequent ion irradiation. The specimens were returned to ORNL’s Low Activation Materials Development and Analysis facility, prepared via focused ion beam for examination using scanning/transmission electron microscopy (S/TEM), and then examined using S/TEM to measure the as-irradiated microstructure. This report briefly summarizes the S/TEM results obtained at ORNL’s Low Activation Materials Development and Analysis facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗