Search NASA⌕ Search

SEARCH · Search NASA

Results for “foil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Experimental and simulated heating in nanocrystalline diamond charge exchange injection films using an electron beam to mimic SNS conditions

Nanocrystalline diamond (NCD) foils have been in use at the Spallation Neutron Source as primary stripper foils for charge exchange injection since the machine’s inception. NCD’s low atomic number leads to reduced beam scattering while still being easy to handle, as opposed to even lighter elements. NCD foils also have the benefit of being free-standing, and rigid when grown under the right conditions to minimize residual stresses. This study overviews a method to mimic the Spallation Neutron Source (SNS) beam and characterize thermally driven failure of NCD foils. To do this, a foil test stand was developed with in situ diagnostics that tracks signs of foil sublimation and thinning. The foil test stand’s electron beam is equated to the SNS beamline by comparing peak deposited energy densities for both beams. Post-mortem testing is also conducted to help elucidate changes the NCD foils undergo during exposure to the beam. Further, a COMSOL simulation was also developed as a method to assess potential future changes to the NCD film and predict how changes to beam conditions will effect foil temperatures. This method allows for examination of the NCD foil’s thermal limits and can be used to assess future changes to SNS stripper foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

PNNL's Characterization Summary for MP-2 Experiment

Characterization of as-fabricated fuel was performed at Pacific Northwest National Laboratory (PNNL) in accordance with the characterization plan for the fabrication of U 10Mo plate fuel for the U.S. High Performance Research Reactor conversion program’s Fuel Fabrication Pillar (INL 2021). Similar characterization work is also being performed at Idaho National Laboratory to provide a detailed understanding of the as-fabricated foils that would be irradiated in the Mini-Plate 2 (MP 2) experiment. Under the MP 2 characterization plan, foils are studied that have different fabrication parameters (such as rolling condition, rolling thickness reduction, co-rolling with Zr layers). Similar samples from master foils were sent to both the organizations, so that the testing and analysis can be done independently using similar equipment and standardized measurement and analysis procedures. A final, consolidated report will be prepared based on this work and will summarize all the information obtained from the two laboratories. The MP 2 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare results obtained independently, and achieve a two-way validation. In Fiscal Year 2022, PNNL received five MP 2 cast (PD STD2) samples to examine the foils’ chemistry and microstructure. For each cast sample, PNNL received samples from three different locations. PNNL also received and characterized 24 U 10Mo foil samples, by sectioning four pieces/specimens from each foil, in accordance with the MP 2 Characterization Plan (INL 2021). These 24 samples consist of four types of foils from BWX Technologies: 0.047 in. thick hot-rolled and annealed samples with Zr layers; 0.025 in. thick cold-rolled and annealed samples with Zr layers; 0.0105 in. thick cold-rolled and annealed samples with Zr layers. Along with these, PNNL also received four plates with Zr layers that were 0.025 in. and 0.0105 in. thick. This report describes the results of PNNL’s MP 2 foil characterization. Microstructure, Mo homogeneity, carbide fraction and morphology, U 10Mo foil thickness, and Zr thickness were evaluated in both the longitudinal and transverse directions for all the foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the efficacy of post-build thermomechanical treatments to improve properties of Zirconium fabricated using ultrasonic additive manufacturing

Here, hot-isostatic pressing has been applied to Zirconium plate fabricated using the ultrasonic additive manufacturing (UAM) technique to enhance interfacial bond quality. Specimens heated to 800 C for 1 h at 100 MPa pressure showed grain growth across many prior foil-to-foil interfaces, thereby increasing foil adhesion. In addition to the material softening induced by a loss of Hall-Petch strengthening, premature failure of specimens loaded parallel to the build direction was observed. Premature specimen failure was attributed to the local delamination at prior foil-to-foil boundaries where grain growth was pinned by Ti impurities introduced during the UAM process via the interaction between a Ti-alloy buffer foil and the welded Zr-foils underneath. In addition, the presence of Ti along select foil interfaces resulted in the nucleation and growth of secondary (Zr,Ti)(Fe,Cr) laves phases during higher-temperature thermomechanical processing. Using a combination of micro-scale X-ray computed tomography, fractography, and in-situ digital image correlation, the effect of defects along prior foil-to-foil boundaries was revealed as delamination-assisted plasticity accelerated specimen failure in preferred tensile orientations. These findings underscore the importance of impurity control when optimizing weld quality of higher-strength material systems using ultrasonic welding.

36 MATERIALS SCIENCE↗

Reaction Rate Distribution Measurements in ZPPR-15

Small metal foils were irradiated in ZPPR-15 to measure distributions for 239 Pu(n,f), 235 U(n,f), 238 U(n,f), 238 U(n,γ), 115 In(n,n’) and 115 In(n,γ) reaction rates in ZPPR-15. The measured data were reported as basic reaction rate distributions for individual foils, cell-averaged reaction rate distributions and spectral indices or reaction rate ratios. All of the measured data were analyzed and tabulated in such a manner that the data can be readily compared with computed values. The published uncertainties for ZPPR-15 the reaction rate measurements include the statistical uncertainties in the measurements, reproducibility uncertainty and small uncertainties related to corrections for items such as foil compositions and post-irradiation decay between reactor shutdown and foil measurement. There are additional uncertainty components related to detector calibration that are not included in the published uncertainties. A full uncertainty analysis was performed for each foil measurement and for quantities derived from the basic foil measurements. The significant uncertainties were quantified, and a total uncertainty was derived for each measured value. The ZPPR-15 experimental records were used to create detailed as-built Monte Carlo models for the foil reaction rate measurements in ZPPR-15 loadings 123, 134 and 203 and for the fission chamber measurements of 237 Np and 242 Pu fission rates in ZPPR-15 loading 141. Because there were many foils distributed in the ZPPR-15 assembly and because an individual foil occupies a negligible volume in the ZPPR-15 assembly, direct Monte Carlo calculations of the measured foil reaction rates would require an impractical computational effort. The as-built Monte Carlo models and related files were prepared for conversion to deterministic models that can be calculated with realistic computational effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The interstellar gas experiment: Analysis in progress

The interstellar gas experiment (IGE) exposed thin metallic foils in order to collect neutral interstellar particles which penetrate the solar system due to their motion relative to the sun. These atoms were entrapped in the collecting foils along with precipitating magnetospheric ions and with ambient atmospheric atoms. For the entire duration of the LDEF mission, seven of the foils collected particles arriving from seven different directions as seen from the spacecraft. In the mass spectrometric analysis of the trapped noble gas component, we detected the He-3, He-4, Ne-20, and Ne-22 isotopes. In order to infer the isotopic ratios in the interstellar medium from the measured concentrations found in the foil piece, several lines of investigation had to be initiated. The flux of incident noble gas atoms from the ambient atmosphere was estimated by detailed calculations. The contributions proved to be negligible, supporting the experimental evidence. Foil and machine backgrounds for the four isotopes which were measured had to be assessed individually. While this was easy for He-4, spurious foil background of He-3 had to be monitored carefully by analyzing unflown foil pieces. Trapped Ne concentrations are not far above the background. During the flight, a stuck electrical relay precluded the foil-trays from sequencing as designed. Therefore, we could not use the seasonal variation of the direction of the incoming interstellar atoms to make the distinction between interstellar and magnetospheric components of the trapped particles. Instead, we had to try the method of stepwise heating to extract the interstellar component at lower temperatures than we use to extract the magnetospheric component (the interstellars hit the foil with lower energies than most of the magnetospherics). New limiting values for the isotopic composition of the interstellar medium, unavailable yet from any other method of measurement, are emerging from this analysis.

Buehler, F.↗

The Interstellar Gas Experiment: Analysis in progress

The Interstellar Gas Experiment (IGE) exposed thin metallic foils aboard the LDEF spacecraft in low Earth orbit in order to collect neutral interstellar particles which penetrate the solar system due to their motion relative to the sun. By mechanical penetration these atoms were imbedded in the collecting foils along with precipitating magnetospheric ions and, possibly, with ambient atmospheric atoms. During the entire LDEF mission, seven of these foils collected particles arriving from seven different directions as seen from the spacecraft. After the foils were returned to Earth, a mass spectrometric analysis of the noble gas component of the trapped particles was begun. The isotopes of He-3, He-4, Ne-20, and Ne-22 were detected. We have given a first account of the experiment. In order to infer the isotopic ratios in the interstellar medium from the concentrations found in the foils, several lines of investigation had to be initiated. The flux of ambient atmospheric noble gas atoms moving toward the foils due to the orbital motion of LDEF was estimated by detailed calculations. Any of these particles which evaded the baffles in the IGE collector could be entrapped in the foils as a background flux. However, the calculations have shown that this flux is negligible, which was the intent of the experiment hardware design. This conclusion is supported by the measurements. However, both the concentration of trapped helium and its impact energy indicate that the flux of magnetospheric ions which was captured was larger than had been expected. In fact, it appears that the magnetospheric particles constitute the largest fraction of the particles in the foils. Since little is known about this particle flux, their presence in the IGE foils appears fortunate. The analysis of these particles provides information about their isotropic composition and average flux.

Buehler, F.↗

Optical Property Enhancement and Durability Evaluation of Heat Receiver Aperture Shield Materials

Under the Solar Dynamic Flight Demonstration (SDFD) program, NASA Lewis Research Center worked with AlliedSignal Aerospace, the heat receiver contractor, on the development, characterization and durability testing of refractory metals to obtain appropriate optical and thermal properties for the SDFD heat receiver aperture shield. Molybdenum and tungsten foils were grit-blasted using silicon carbide or alumina grit under various grit-blasting conditions for optical property enhancement. Black rhenium coated tungsten foil was also evaluated. Tungsten, black rhenium-coated tungsten, and grit-blasted tungsten screens of various mesh sizes were placed over the pristine and grit-blasted foils for optical property characterization. Grit-blasting was found to be effective in decreasing the specular reflectance and the absorptance/emittance ratio of the refractory foils. The placement of a screen further enhanced these optical properties, with a grit-blasted screen over a grit-blasted foil producing the best results. Based on the optical property enhancement results, samples were tested for atomic oxygen and vacuum heat treatment durability. Grit-blasted (Al2O3 grit) 2 mil tungsten foil was chosen for the exterior layer of the SDFD heat receiver aperture shield. A 0.007 in. wire diameter, 20 x 20 mesh tungsten screen was chosen to cover the tungsten foil. Based on these test results, a heat receiver aperture shield test unit has been built with the screen covered grit-blast tungsten foil exterior layers. The aperture shield was tested and verified the thermal and structural durability of the outer foil layers during an off-pointing period.

deGroh, Kim K.↗

Modification of Bushing Test Rig and Research of Variable Inlet Guide Vane Bushings For Further Development of PM304 Bushings

PS304 is a high temperature solid lubricant coating comprised of a nickel-chrome binder, chrome oxide hardener, barium-calcium fluoride high temperature lubricant, and silver as the low temperature lubricant. This coating is used to lubricate Oil-Free Foil Air Bearings as they experience friction and wear during start up and shut down. The coating deposition process begins with undercutting the shaft. This area is then sandblasted to provide a rough surface for the coating to adhere to. The coating powder is then sent through the plasma spray gun and a reasonably thick layer is applied to the undercut area of the shaft. The coating is then ground down even with the surface of the shaft and gets a nice polished finish. The foil air bearings use the solid lubricant, as mentioned above, during start up and shut down. During normal operating conditions, generally above 2000RPM, the bearings utilize air as their lubricant. Foil air bearings are comprised of a thin top foil and a corrugated bump foil. They have an interference fit with the shaft before operation. As the air gets "trapped" between the top foil and the shaft, it presses the top foil against the bump foil, in turn compressing the bumps. As the bumps compress, it allows for the air to separate the top foil from the shaft, therefore, utilizing the trapped air as its lubricant.

Yanke, Anne↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Hypervelocity impact microfoil perforations in the LEO space environment (LDEF, MAP AO-023 experiment)

The Microabrasion Foil Experiment comprises arrays of frames, each supporting two layers of closely spaced metallic foils and a back-stop plate. The arrays, deploying aluminum and brass foil ranging from 1.5 to some 30 microns were exposed for 5.78 years on NASA's LDEF at a mean altitude of 458 km. They were deployed on the North, South, East, West, and Space pointing faces; results presented comprise the perforation rates for each location as a function of foil thickness. Initial results refer primarily to aluminum of 5 microns thickness or greater. This penetration distribution, comprising 2,342 perforations in total, shows significantly differing characteristics for each detector face. The anisotropy confirms, incorporating the dynamics of particulate orbital mechanics, the dominance of incorporating extraterrestrial particulates penetrating thicknesses greater than 20 microns in Al foil, yielding fluxes compatible with hyperbolic geocentric velocities. For thinner foils, a disproportionate increase in flux of particles on the East, North, and South faces shows the presence of orbital particulates which exceed the extraterrestrial component perforation rate at 5 micron foil thickness by a factor of approx. 4.

Mcdonnell, J. A. M.↗

Heat Transfer in High Temperature Multilayer Insulation

High temperature multilayer insulations have been investigated as an effective component of thermal-protection systems for atmospheric re-entry of reusable launch vehicles. Heat transfer in multilayer insulations consisting of thin, gold-coated, ceramic reflective foils and Saffil(TradeMark) fibrous insulation spacers was studied both numerically and experimentally. A finite volume numerical thermal model using combined conduction (gaseous and solid) and radiation in porous media was developed. A two-flux model with anisotropic scattering was used for radiation heat transfer in the fibrous insulation spacers between the reflective foils. The thermal model was validated by comparison with effective thermal conductivity measurements in an apparatus based on ASTM standard C201. Measurements were performed at environmental pressures in the range from 1x10(exp -4) to 760 torr over the temperature range from 300 to 1300 K. Four multilayer samples with nominal densities of 48 kg/cu m were tested. The first sample was 13.3 mm thick and had four evenly spaced reflective foils. The other three samples were 26.6 mm thick and utilized either one, two, or four reflective foils, located near the hot boundary with nominal foil spacing of 1.7 mm. The validated thermal model was then used to study relevant design parameters, such as reflective foil spacing and location in the stack-up and coating of one or both sides of foils.

Daryabeigi, Kamran↗

Preliminary Analysis for an Optimized Oil-Free Rotorcraft Engine Concept

Recent developments in gas foil bearing technology have led to numerous advanced high-speed rotating system concepts, many of which have become either commercial products or experimental test articles. Examples include Oil-Free microturbines, motors, generators and turbochargers. The driving forces for integrating gas foil bearings into these high-speed systems are the benefits promised by removing the oil lubrication system. Elimination of the oil system leads to reduced emissions, increased reliability, and decreased maintenance costs. Another benefit is reduced power plant weight. For rotorcraft applications, this would be a major advantage, as every pound removed from the propulsion system results in a payload benefit. Implementing foil gas bearings throughout a rotorcraft gas turbine engine is an important long-term goal that requires overcoming numerous technological hurdles. Adequate thrust bearing load capacity and potentially large gearbox applied radial loads are among them. However, by replacing the turbine end, or hot section, rolling element bearing with a gas foil bearing many of the above benefits can be realized. To this end, engine manufacturers are beginning to explore the possibilities of hot section gas foil bearings in propulsion engines. This paper presents a logical follow-on activity by analyzing a conceptual rotorcraft engine to determine the feasibility of a foil bearing supported core. Using a combination of rotordynamic analyses and a load capacity model, it is shown to be reasonable to consider a gas foil bearing core section.

Howard, Samuel A.↗

Low temperature hydrogen plasma permeation in palladium and its alloys for fuel recycling in fusion systems

Superpermeation of hydrogen isotopes through metal foils is a critical component for efficient fuel recycling in fusion power systems. In that context hydrogen permeation through foils of palladium and its alloys with silver and copper was studied at low temperature (60 - 200°C) under plasma exposure. These alloys differ significantly in both bulk and surface properties, and comparisons can provide mechanistic insights. Here, permeation was observed only during plasma operation, confirming the negligible contribution of molecular hydrogen to the observed flux. As-received foils required surface treatment to achieve top performance. For Pd and Pd75Ag25 an oxidation treatment increased permeation an order of magnitude, but proved unstable as this desirable surface was reduced under hydrogen plasma exposure. In contrast, an Ar plasma cleaning step provided both high and stable flux. As-received FCC phase Pd60Cu40 foils required annealing to transform it into the high permeability BCC phase that delivered top performance. All foils displayed similar temperature dependence with flux declining with temperature, suggesting that the primary rate-limiting step is absorption of superthermal hydrogen. Among these foils the hydrogen flux through PdCu was 3 - 5X greater than that of Pd or PdAg, which were similar. The superiority of BCC PdCu is attributed to its superior hydrogen desorption kinetics. Using PdCu 100% permeation of supplied hydrogen was achieved, and the flux saturated with increasing plasma power at values >10 –2 mol H•m –2 •s– 1 , and under these conditions permeation rates are equivalent with or without the membrane present. The fluxes achieved are the highest reported to date at these conditions, and the results highlight the important roles of both surface and bulk properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measured Reaction Rate Ratios of 235 U, 238 U, 237 Np, 239 Pu Samples in the PFUNS 235 U Prompt Fission Neutron Spectrum Criticality Experiment

The Prompt Fission Uranium Neutron Spectrum experiment, an experiment to reduce uncertainties in the high energy tail of the 235 U prompt fission spectrum, achieved success by performing two separate irradiations measuring approximately 40 different IRDFF-II reactions total using over 20 different foil materials at the National Criticality Experiments Research Center in February 2024. The criticality experiment utilized a set of highly enriched uranium hemispherical shells of increasing diameters with a large void in the center where the samples were located. The focus of this work is the first of two PFUNS irradiations focused on irradiating two of each fission foils, one bare and one cadmium covered, along with metal activation foils containing reaction products with short half-lives, such as indium, iron, and gold along with nickel fluence monitors. This work focuses on presenting the initial reaction rate ratio results of the fission foils from the aforementioned first irradiation to assist in nuclear data validation of those species in a nearly pure 235 U prompt fission neutron spectrum and compares to the Lady Godiva and Flattop-25 historic experiments at the Los Alamos Critical Experiments Facility. Future work will combine fission foil and metallic activation foil reaction rate ratio results from both the first and second higher power irradiation and reaction rates for a final spectral adjustment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Doppler-shifted reflections of X rays in beamfoil spectroscopy

Carbon foils were positioned at roughly 10 deg to the conventional perpendicular position so that the spectrometer would view the beam on emergence from the foil, with no radiation shielded by a bowed or wrinkled foil or by the foil holder. Extraneous peaks due to reflected radiation were detected in the spectrum obtained with the tilted foil. A large satellite appears longward of the spectral line and is attributed to Doppler-shifted radiation reflected from the foil surface. Special tests arranged to validate the origin of the satellites are described. The relative intensity of the reflected radiation compared with the direct radiation observed is at variance with the relative intensities reported for longer wavelengths. The reasons for this, possible effects of spectrometer geometry, and applications in the investigation or generation of polarization remain to be investigated

Bernstein, E. M.↗