Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Acoustic design considerations: Review of rotor acoustic sources

It is not sufficient to optimize a rotor design in terms of a single noise level calculated for a single flight condition and a single measurement location. The various noise sources, their frequency content, amplitude, and directivity as a function of operating condition must be considered. A summary of the frequency ranges, directivity patterns and the most important operational and design parameters for major rotor noise sources is presented. It is difficult to generalize design requirements for rotor noise because the acoustic output varies so widely depending on the noise source, flight condition, measurement location, and frequency range. However, assuming the rotor must lift a fixed nominal payload and operate over a wide range of flight conditions, three general design guidelines can be stated: (1) minimize tip Mach number; (2) minimize blade thickness in the tip region; and (3) minimize gradients in the spanwise lift distribution in the tip region. Constraints on blade thickness, maximum values for hover tip Mach number, advancing tip Mach number and spanwise lift coefficient gradient will be specified during the aerodynamic, dynamic and structural optimization process. The rotor noise sources to be considered include the low frequency loading and thickness noise, and the higher frequency noise due to blade-vortex interactions (BVI). The analyses to be employed will include the comprehensive rotor analysis and design program CAMRAD and the rotor noise prediction program WOPWOP.

Martin, Ruth M.↗

Evidence for drift waves in the turbulence of reversed field pinch plasmas

A detailed characterization of the high-frequency range of the fluctuation spectrum in reversed field pinch plasmas is presented, revealing a variety of new features distinct from global tearing modes and the cascade that they are thought to drive. The anisotropic broadband spectrum of the fluctuating electric field is measured. The power in the fluctuating kinetic energy (1/2) m(i)n(i)(V) over tilde (2)((E) over tilde xB0), previously measured to be smaller than the magnetic energy in the tearing-mode-unstable frequency range, becomes greater than and diverges from the magnetic energy above 60-80 kHz. The lack of equipartition at high frequencies coincides with the measured signatures of the independent fluctuation activity broadly consistent with the drift-wave fluctuations. Statistical coherence measurements reveal the mode activity that is compressive with a large amplitude in the vicinity of strong density gradients and with a phase speed comparable to the electron drift speed. There is a distinct high-frequency correlation between the fluctuations of density and the parallel magnetic field. Elevated coherences associated with this fluctuation feature return more quickly after a sawtooth event than the corresponding coherences associated with tearing activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Circulating Harmonic Currents in Paralleled Three Level ANPC Inverters using SVM

In paralleled voltage source inverters (VSI), circulating current has both high frequency and low frequency components, and its spectrum highly depends on the modulation scheme. Previous research has mostly focused on the circulating current suppression for paralleled two-level VSIs. Little literature exists on similar analysis for paralleled three-level VSIs using space vector modulation. A detailed circulating current spectrum on full frequency range has not been well developed. This paper presents an improved analytical model for three-level space vector modulation (SVM), considering the impacts of regularly sampled reference and dead time. Then, circulating harmonic currents are determined across the full frequency range for various interleaving angles of two three-level ANPC inverters. The calculated harmonics are also verified by experimental results.

Niu, Jiahao↗

Investigation and optimization of low-frequency noise performance in readout electronics of dc superconducting quantum interference device

We investigated and optimized the low-frequency noise characteristics of a preamplifier used for readout of direct current superconducting quantum interference devices (SQUIDs). When the SQUID output was detected directly using a room-temperature low-voltage-noise preamplifier, the low-frequency noise of a SQUID system was found to be dominated by the input current noise of the preamplifiers in case of a large dynamic resistance of the SQUID. To reduce the current noise of the preamplifier in the low-frequency range, we investigated the dependence of total preamplifier noise on the collector current and source resistance. When the collector current was decreased from 8.4 mA to 3 mA in the preamplifier made of 3 parallel SSM2220 transistor pairs, the low-frequency total voltage noise of the preamplifier (at 0.1 Hz) decreased by about 3 times for a source resistance of 30 Ω whereas the white noise level remained nearly unchanged. Since the relative contribution of preamplifier's input voltage and current noise is different depending on the dynamic resistance or flux-to-voltage transfer of the SQUID, the results showed that the total noise of a SQUID system at low-frequency range can be improved significantly by optimizing the preamplifier circuit parameters, mainly the collector current in case of low-noise bipolar transistor pairs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Nature of the mHz X-Ray QPOs from ULX M82 X-1: Evidence for Timing-Spectral (anti) Correlation

Using all the archival XMM-Newton X-ray (3-10 keV) observations of the ultraluminous X-ray source (ULX) M82 X-1 we searched for a correlation between its variable mHz quasi-periodic oscillation (QPO) frequency and its energy spectral power-law index. These quantities are known to correlate in stellar mass black holes (StMBHs) exhibiting Type-C QPOs (approx 0.2-15 Hz). The detection of such a correlation would strengthen the identification of its mHz QPOs as Type-C and enable a more reliable mass estimate by scaling its QPO frequencies to those of Type-C QPOs in StMBHs of known mass. We resolved the count rates of M82 X-1 and a nearby bright ULX (source 5/X42.3+59) through surface brightness modeling and identify observations in which M82 X-1 was at least as bright as source 5. Using only those observations, we detect QPOs in the frequency range of 36-210 mHz during which the energy spectral power-law index varied from 1.7-2.2. Interestingly, we find evidence for an anti-correlation (Pearsons correlation coefficient = -0.95) between the power-law index and the QPO centroid frequency. While such an anti-correlation is observed in StMBHs at high Type-C QPO frequencies (approx 5-15 Hz), the frequency range over which it holds in StMBHs is significantly smaller (factor of approx 1.5-3) than the QPO range reported here from M82 X-1 (factor of 6). However, it remains possible that contamination from source 5 can bias our result. Joint Chandra/XMM-Newton observations in the future can resolve this problem and confirm the timing-spectral anti-correlation reported here.

Pasham, Dheeraj R.↗

Optimal one-section and two-section circular sound-absorbing duct liners for plane-wave and monopole sources without flow

A discrete frequency study is made of the influence of source characteristics on the optimal properties of acoustically lined uniform and two section ducts. Two simplified sources, a plane wave and a monopole, are considered in some detail and over a greater frequency range than has been previously studied. Source and termination impedance effects are given limited examination. An example of a turbomachinery source and three associated source variants is also presented. Optimal liner designs based on modal theory approach the Cremer criterion at low frequencies and the geometric acoustics limit at high frequencies. Over an intermediate frequency range, optimal two section liners produced higher transmission losses than did the uniform configurations. Source distribution effects were found to have a significant effect on optimal liner design, but source and termination impedance effects appear to be relatively unimportant.

Lester, H. C.↗

Influence of gravity on cat vertical vestibulo-ocular reflex

The vertical vestibulo-ocular reflex (VOR) was recorded in cats using electro-oculography during sinusoidal angular pitch. Peak stimulus velocity was 50 deg/s over a frequency range from 0.01 to 4.0 Hz. To test the effect of gravity on the vertical VOR, the animal was pitched while sitting upright or lying on its side. Upright pitch changed the cat's orientation relative to gravity, while on-side pitch did not. The cumulative slow component position of the eye during on-side pitch was less symmetric than during upright pitch. Over the mid-frequency range (0.1 to 1.0 Hz), the average gain of the vertical VOR was 14.5 percent higher during upright pitch than during on-side pitch. At low frequencies (less than 0.05 Hz) changing head position relative to gravity raised the vertical VOR gain and kept the reflex in phase with stimulus velocity. These results indicate that gravity-sensitive mechanisms make the vertical VOR more compensatory.

Tomko, D. L.↗

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

Axion Dark Matter eXperiment: Run 1A analysis details

The ADMX Collaboration gathered data for its Run 1A axion dark matter search from January 2017 to June 2017, scanning with an axion haloscope over the frequency range 645–680 MHz ( 2.66 – 2.81 μ eV in axion mass) at Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) sensitivity. The resulting axion search found no axionlike signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Silicon Carbide Pressure Sensor in Turbofan Engine Core Exhaust Nozzle

We report the results of the evaluation of single crystal 4H-silicon carbide piezoresistive pressure sensors that were directly inserted at the compressor and core exhaust nozzle exits, in shear contact with the engine-internal flow streams of the NASA DGEN Aeropropulsion Research Turbofan, where the operating temperatures at maximum power were ~230 oC, and ~460 oC, respectively. In addition to demonstrating sensor survivability during this maiden test, the frequency responses of the silicon-carbide sensors at the core-nozzle exit were compared against industry-standard silicon-based piezoresistive pressure transducers that externally placed, using an infinite-tube-probe arrangement. The low-voltage output of these early-development SiC sensors limited the frequency range with an acceptable signal-to-noise-ratio for the current application to less than about 2,500 Hz. The low output of the SiC sensors were due to a conservative burst-pressure diaphragm design that can be optimized to increase the frequency range. The results from this initial campaign offered insights to aspects of the sensor that would require further improvement, with the goal of achieving full-bandwidth capture of engine unsteady pressure fluctuations by direct interrogation of the flow field in hostile-environment engine-core components.

Silicon Carbide↗

Evaluation of SiC Pressure Sensors in Turbofan Engine Core Exhaust Nozzle

We report the results of the evaluation of single crystal 4H-silicon carbide piezoresistive pressure sensors that were directly inserted at the compressor and core exhaust nozzle exits, in shear contact with the engine-internal flow streams of the NASA DGEN Aeropropulsion Research Turbofan, where the operating temperatures at maximum power were ~230°C, and ~460°C, respectively. In addition to demonstrating sensor survivability during this maiden test, the frequency responses of the silicon-carbide sensors at the core-nozzle exit were compared against industry-standard silicon-based piezoresistive pressure transducers that externally placed, using an infinite-tube-probe arrangement. The low-voltage output of these early-development SiC sensors limited the frequency range with an acceptable signal-to-noise-ratio for the current application to less than about 2,500 Hz. The low output of the SiC sensors were due to a conservative burst-pressure diaphragm design that can be optimized to increase the frequency range. The results from this initial campaign offered insights to aspects of the sensor that would require further improvement, with the goal of achieving full-bandwidth capture of engine unsteady pressure fluctuations by direct interrogation of the flow field in hostile-environment engine-core components.

Silicon Carbide↗

ON THE NATURE OF THE SMALL-SCALE STRUCTURE IN THE COSMIC MICROWAVE BACKGROUND OBSERVED BY PLANCK AND WMAP

Small-scale features observed by Wilkinson Microwave Anisotropy Probe ( WMAP ) and PLANCK in the frequency range of 22–90 GHz show a nearly flat spectrum, which meets with expectations that they originate in the early universe. However, free–free emission from electrons in small angular scale galactic sources that suffer beam dilution very closely mimic the observed spectrum in this frequency range. Fitting such a model to the PLANCK and WMAP data shows that the angular size required to fit the data is comparable to the angular width of associated H i filaments found in the Galactic Arecibo L-Band Feed Array-H isurvey data. Also, the temperature of the electrons is found to be in the range of 100–300 K. The phenomenon revealed by these data may contribute to a more precise characterization of the foreground masks required to interpret the cosmological aspect of PLANCK and WMAP data.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio wave emitted by an extensive air showers in 10KHz to 1MHz region

The importance of radio waves in a frequency range of less than 1MHz in an EAS shower is discussed. Estimates of radio intensities at 10KHz, 100KHz and 1MHz in EAS showers made on the basis of the Kahn-Lerche theory. Negative charge excess in a shower is the main source of low frequency radio emission, in spite of the importance of the contribution of transverse current in the geomagnetic field in a higher frequency range. An estimate is also made for radio intensity produced when the shower hits the ground. The contribution of this process seems to be important at a large distance, i.e., beyond 1km from the shower axis.

Nichimura, J.↗

Testing Fundamental Properties of Space with the Fermilab Holometer

Precision length measurements provide valuable insights about the fundamental properties of space-time. The Holometer is a research program to both experimentally probe signatures of the Planck scale and to extend the accessible frequency range from kHz up to MHz for gravitational wave searches. The instrument consists of separate yet identical 39-meter Michelson interferometers operated at Fermi National Accelerator Laboratory, which can reach length sensitivities better than ${10}^{-20}\mathrm{m/}\sqrt{\mathrm{Hz}}$ within the 1-10 MHz frequency range. Lastly, the Holometer is fully operational with 130 of hours of science quality data obtained during the first observational campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave/particle interactions in the plasma sheet

The most frequent and intense waves observed in the geomagnetic tail region are short wavelength electrostatic broadband emissions. Early observations of these waves were made by using IMP 7 and 8 respectively. A broad frequency range for the waves was found, from about 10Hz to several kHz, with an average r.m.s. electric field amplitude of about 1mV/m was found. Other less frequent and less intense wave modes were also identified: magnetic noise bursts and electrostatic electron-cyclotron waves. The highest frequency of occurrence of the electrostatic noise as found in the region near the plasma sheet boundary when anisotropic fluxes of ions streaming either earthward or antiearthward were present. It was confirmed, by using ISEE data that the waves were usually observed during times of ion streaming and that the intensity and frequency range was maximum in the plasma sheet boundary layer and fell off dramatically in the tail lobe and central plasma sheet regions. It is suggested that increases in the electron and ion temperature in going from the tail lobe to the central plasma sheet are a result of scattering of resonant, boundary layer plasma.

Dusenberry, P. R.↗

Development of Broadband Microwave Absorber and Measurement of Its Magnetic and Microwave Properties

Toroid shape Co-doped barium hexaferrites of composition (BaFe{sub 11}CoO{sub 19}) are prepared by standard sintering technology as a sample. In this work, XRD is used to identify the structure of synthesized sample. Vibrating sample magnetometer is used to obtain magnetic hysteresis loop of sample. Scanning electron microscope is used for surface morphology of sample. The complex permeability and permittivity are measured with commercial automation measurement set up in the 2–18 GHz frequency range. As a result of measurement, the calculation of reflection loss of the synthesized samples has been carried out. Investigation of microwave absorption properties revealed that the maximum reflection loss of Co-doped barium hexaferrite sample is around −20 dB and almost flat in the measurement frequency band. From these results, it was concluded that Co-doped barium hexaferrites of composition had a good potential as microwave absorber in the broadband frequency range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TerraHertz Free Electron Laser Applications for Satellite Remote Sensing

The development of a Free Electron Laser (EL) operating in the terahertz frequency regime by the group at the University of Hawaii (Elias et al.) represents a significant new opportunity in the area of atmospheric remote sensing. The FEL has 2 salient features that create a unique opportunity. First of all it represents the only source in this frequency range with sufficient power to enable lidar instrumentation. Secondly its very high electrical efficiency (several times more efficient than any currently employed spaceborne laser) renders it a strong candidate for use in satellite remote sensing. On the negative side the atmosphere is rather strongly absorbing throughout this frequency range due primarily to the water vapor continuum absorption. This means that the instruments using this laser will not be able to access the lower troposphere because of its very high water concentration.. However the instrument will be very capable of measurements in the upper troposphere and stratosphere. A passive instrument, the Microwave Limb Sounder on the UARS satellite operated by Jet Propulsion Laboratory, has already demonstrated that this wavelength region can be used for chemical species with strong emission lines. A lidar would complement the capabilities of this instrument by providing the capability to measure absorbing species in the upper atmosphere. I will discuss the design of such an instrument in greater detail and estimate its performance in measuring a number of chemical species of interest to the Earth Science community.

Heaps, William S.↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗