Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Pulmonary Toxicity in Stage III Non-Small Cell Lung Cancer Patients Treated With High-Dose (74 Gy) 3-Dimensional Conformal Thoracic Radiotherapy and Concurrent Chemotherapy Following Induction Chemotherapy: A Secondary Analysis of Cancer and Leukemia Group B (CALGB) Trial 30105

Purpose: Cancer and Leukemia Group B (CALGB) 30105 tested two different concurrent chemoradiotherapy platforms with high-dose (74 Gy) three-dimensional conformal radiotherapy (3D-CRT) after two cycles of induction chemotherapy for Stage IIIA/IIIB non-small cell lung cancer (NSCLC) patients to determine if either could achieve a primary endpoint of >18-month median survival. Final results of 30105 demonstrated that induction carboplatin and gemcitabine and concurrent gemcitabine 3D-CRT was not feasible because of treatment-related toxicity. However, induction and concurrent carboplatin/paclitaxel with 74 Gy 3D-CRT had a median survival of 24 months, and is the basis for the experimental arm in CALGB 30610/RTOG 0617/N0628. We conducted a secondary analysis of all patients to determine predictors of treatment-related pulmonary toxicity. Methods and Materials: Patient, tumor, and treatment-related variables were analyzed to determine their relation with treatment-related pulmonary toxicity. Results: Older age, higher N stage, larger planning target volume (PTV)1, smaller total lung volume/PTV1 ratio, larger V20, and larger mean lung dose were associated with increasing pulmonary toxicity on univariate analysis. Multivariate analysis confirmed that V20 and nodal stage as well as treatment with concurrent gemcitabine were associated with treatment-related toxicity. A high-risk group comprising patients with N3 disease and V20 >38% was associated with 80% of Grades 3-5 pulmonary toxicity cases. Conclusions: Elevated V20 and N3 disease status are important predictors of treatment related pulmonary toxicity in patients treated with high-dose 3D-CRT and concurrent chemotherapy. Further studies may use these metrics in considering patients for these treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity of Cirrus Simulations in Idealized Situations: The WG2 Test Cases

GCSS Cirrus Cloud Systems Working Group (WG2) is presently conducting a comparison of cirrus cloud models for idealized initial conditions. The experiments involve binary (off/on) tests of model sensitivity to infrared radiative processes, and thermal stratification, and vertical wind shear for situations of weakly forced (3 cm/s uplift) cold (-60 to -70 C) and warm (-35 to -50 C) cirrus clouds. A range of model types are involved including parcel, SCM, 2-D CRM, 3-D CRM and LES models. The test cases will be described and results from 2-dimensional cirrus cloud models with bulk microphysics (implicit second moment scheme) and explicit bin microphysics will be compared. Vertical ice mass flux (particle fall speed) is a critical model component leading to significant intermodel differences. Efforts are ongoing to better quantify this aspect. Future plans of WG2 will also be briefly described and include model comparisons for a well-observed case of cold (ARM IOP) cirrus and of warm (EUCREX) cirrus, as well as, a joint activity with WG4 to consider the treatment of anvil cirrus in a variety of models.

Starr, David OC.↗

Drug delivery from hydrophobic-modified mesoporous silicas: Control via modification level and site-selective modification

Dimethylsilyl (DMS) modified mesoporous silicas were successfully prepared via co-condensation and post-grafting modification methods. The post-grafting modification was carried out by the reaction of the as-synthesized MCM-41 material (before CTAB removal) with diethoxydimethylsinale (DEDMS). N{sub 2} adsorption-desorption and {sup 29}Si MAS NMR characterization demonstrated that different amount of DMS groups were successfully incorporated into the co-condensation modified samples, and the functional DMS groups were placed selectively on the pore openings and external pore surfaces in the post-grafting modified samples. Subsequently, the controlled drug delivery properties from the resulting DMS-modified mesoporous silicas were investigated in detail. The drug adsorption experiments showed that the adsorption capacities were mainly depended on the content of silanol group (CSG) in the corresponding carriers. The in vitro tests exhibited that the incorporation of DMS groups greatly retarded the ibuprofen release rate. Moreover, the ibuprofen release profiles could be well modulated by varying DMS modification levels and site-selective distribution of functional groups in mesoporous carriers. - The distribution of DMS groups on the pore surfaces of the mesostructures strongly affects the drug release rate. The P-M41-1 and the P-M41-2 possess the close DMS modification levels as the C-M41-10, but the ibuprofen release rates from the P-M41-1 and P-M41-2 are much slower than that from the C-M41-10.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Long term reliability study and life time model of quantum cascade lasers

Here, we present results of quantum cascade laser lifetime tests under various aging conditions including an accelerated life test. The total accumulated life time exceeds 1.5 × 106 device hours. The longest single device aging time was 46 500 hours without failure in the room temperature aging test. Four failures were found in a group of 19 devices subjected to the accelerated life test with a heat-sink temperature of 60 °C and a continuous-wave current of 1 A. Failure mode analyses revealed that thermally induced oxidation of InP in the semi-insulating layer is the cause of failure. An activation energy of 1.2 eV is derived from the dependence of the failure rate on laser core temperature. The mean time to failure of the quantum cascade lasers operating at a typical condition with the current density of 5 kA/cm2 and heat-sink temperature of 25 °C is expected to be 809 000 hours.

Xie, Feng↗

Fracture testing with surface crack specimens

This paper is a report of ASTM Task Group E24.01.05 on Part-Through Crack Testing. It includes recommendations for the design, preparation, and static fracture testing of surface crack specimens based on the current state of the art. The recommendations are preceded by background information including discussions of stress intensity factors, crack opening displacements, and fracture toughness values associated with surface crack specimens. Cyclic-load and sustained-load tests are discussed briefly. Recommendations for further research are included.

Orange, T. W.↗

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.↗

Comparisons of modified Vasco X-2 and AISI 9310 gear steels

Endurance tests were conducted with four groups of spur gears manufactured from three heats of consumable electrode vacuum melted (CVM) modified Vasco X-2. Endurance tests were also conducted with gears manufactured from CVM AISI 9310. Bench type rolling element fatigue tests were conducted with both materials. Hardness measurements were made to 811 K. There was no statistically significant life difference between the two materials. Life differences between the different heats of modified Vasco X-2 can be attributed to heat treat variation and resultant hardness. Carburization of gear flanks only can eliminate tooth fracture as a primary failure mode for modified Vasco X-2. However, a tooth surface fatigue spall can act as a nucleus of a tooth fracture failure for the modified Vasco X-2.

Townsend, D. P.↗

Studies of the Surface Treatment and Sizing of Carbon Fiber Surfaces on the Mechanical Properties of Composites Containing Carbon Fibers

Carbon fiber reinforced composites are materials where carbon fibers are used to reinforce a matrix to produce a light and strong material with important applications in the aerospace industry. There are many aspects of the preparation of these materials that would benefit from a study which combines the research of groups involved in the production, testing and analysis of these materials, and studies of the basic surface chemistry involved. This final reports presents the results of a project that has developed a collaboration between groups in all three of the major research universities in the State of Kansas, and promises to lead to a collaborative program that covers the major aspects of composite development and application. Sherwood has provided initial fiber surface treatment and sizing together with fiber and composite surface analysis; Lease, Tomblin and Wang have worked together toward the goal of preparing pre-preg and fabrication of laminated panels; Locke has developed computational models to evaluate the effect of surface treatment (and chemistry) on mechanical properties; Lease, Tomblin and Wang have worked together to perform all necessary mechanical testing. The research has been focused on materials that would benefit the High Speed Civil Transport (HSCT) program. The group has visited Dr. Howard Maars and his colleagues at NASA Langley, and has focused their studies on the NASA requirements discussed in this meeting. An important development, requested by NASA scientists, has been the acquisition and study of K3B as a matrix material for the composites. The project has led to the successful acquisition and surface analysis of K3B, together with the successful deposition of this material onto surface oxidized carbon fibers. Mechanical testing, modelling and the construction of composite preparation equipment has been achieved during the grant period.

Sherwood, Peter M. A.↗

Direction and Integration of Experimental Ground Test Capabilities and Computational Methods

This paper groups and summarizes the salient points and findings from two AIAA conference panels targeted at defining the direction, with associated key issues and recommendations, for the integration of experimental ground testing and computational methods. Each panel session utilized rapporteurs to capture comments from both the panel members and the audience. Additionally, a virtual panel of several experts were consulted between the two sessions and their comments were also captured. The information is organized into three time-based groupings, as well as by subject area. These panel sessions were designed to provide guidance to both researchers/developers and experimental/computational service providers in defining the future of ground testing, which will be inextricably integrated with the advancement of computational tools.

Dunn, Steven C.↗

Clinical Sequelae of Thrombus in an Inferior Vena Cava Filter

The purpose of this study was to assess the long-term clinical sequelae of inferior vena cava (IVC) filter thrombus and the effect of anticoagulation on filter thrombus. Of 1,718 patients who had IVC filters placed during 2001-2008, 598 (34.8%) had follow-up abdominal CT. Filter thrombus was seen in 111 of the 598 (18.6%). There were 44 men (39.6%). The mean age at filter placement was 64 years. The medical diseases included cancer in 64, trauma in 15, stroke in 12, and others in 20. The frequency of filter thrombus on CT and asymptomatic filter thrombus on CT was calculated. The frequency of pulmonary embolism (PE) in patients with filter thrombus was calculated. The frequency of thrombus progression or regression (on CT, available in 56) was calculated. The effect of anticoagulation on filter thrombus regression/progression was evaluated using the Fisher exact test by comparing the group of patients who received anticoagulants versus those who did not. A P-value of <0.05 was considered significant. The overall frequency of filter thrombus was 18.6%. Total occlusion of the IVC filter was seen in 12 of 598 (2%). The filter thrombus was asymptomatic in 110 (18.3%). Filter thrombus was detected after a median of 35 days (range, 0-2082) following filter placement. Thrombus extended above the filter in 4 (3.6%); IVC thrombus below the filter was seen in 35(31.5%). Thrombus in the filter occluded <25% of the filter volume in 58 (52.3%), 25-50% in 21 (18.9%), and 50-75% in 20 (18%). Total IVC occlusion was seen in 12 (10.8%). Eighty-three patients received anticoagulation. Sixteen patients developed symptoms of PE. PE was confirmed on CT in 3 of 15 (2.7%). On follow-up, filter thrombus regressed completely in 19 (33.9%) after a median of 6 months. Filter thrombus decreased in size in 13 (23.2%) and it progressed without IVC occlusion in 7 (12.6%). In one (1.7%), filter thrombus progressed to IVC occlusion. Filter thrombus remained stable in 16 (28.6%). There was no significant difference in thrombus regression or progression rates whether or not the patients received anticoagulation for filter thrombus. In conclusion, asymptomatic thrombus in the filter is common and it rarely progresses to complete caval occlusion. Anticoagulation has little effect on the resolution of filter thrombosis and future occurrence of PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Long-Term Outcome and Reinterventional Rate After Uterine Fibroid Embolization with Nonspherical Versus Spherical Polyvinyl Alcohol Particles

PurposeThis study was designed to evaluate the long-term clinical outcome and frequency of reinterventions in patients with uterine fibroids treated with embolization at a single center using polyvinyl alcohol microparticles.MethodsThe study included all patients with symptomatic uterine fibroids treated with uterine fibroid embolization (UFE) with spherical (s-PVA) and nonspherical (ns-PVA) polyvinyl alcohol microparticles during the period January 2001 to January 2011. Clinical success and secondary interventions were examined. Hospital records were reviewed during follow-up, and symptom-specific questionnaires were sent to all patients.ResultsIn total, 515 patients were treated with UFE and 350 patients (67 %) were available for long-term clinical follow-up. Median time of follow-up was 93 (range 76–120.2) months. Eighty-five patients (72 %) had no reinterventions during follow-up in the group embolized with ns-PVA compared with 134 patients (58 %) treated with s-PVA. Thirty-three patients (28 %) underwent secondary interventions in the ns-PVA group compared with 98 patients (42 %) in s-PVA group (χ{sup 2} test, p < 0.01).ConclusionsSpherical PVA particles 500–700 µm showed high reintervention rate at long-term follow-up, and almost one quarter of the patients underwent secondary interventions, suggesting that this type of particle is inappropriate for UFE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parametric model-order reduction for radiation transport using multi-resolution proper orthogonal decomposition

For parametric high-fidelity simulations, it is often desirable to utilize a reduced-order model (ROM) to emulate, at a reduced computational cost, parametric solutions of the governing partial differential equations (PDEs) for unseen parameter values. One commonly employed option is to utilize a data-driven, projection-based ROM supplemented with subspace identification via proper orthogonal decomposition (POD). POD discovers the ROM subspace by computing the singular value decomposition (SVD) of a set of training data from the full-order model (FOM). In streaming-dominated radiation transport simulations with localized sources, solutions often greatly vary over the spatial domain by many orders of magnitude. In such cases, machine-precision arithmetic can be insufficient to obtain an accurate SVD, resulting in a poorly performing ROM. We present a method called multiresolution POD (mrPOD) that mitigates these inaccuracies. The mrPOD method works by decomposing the spatial domain into regions and performing proper orthogonal decomposition on the training dataset separately in each region. In conclusion, mrPOD is tested on single energy group and multigroup atmospheric shielding transport problems and is shown to outperform classic POD.

42 ENGINEERING↗

Effect of dexmedetomidine on rats with convulsive status epilepticus and association with activation of cholinergic anti-inflammatory pathway

Convulsive status epilepticus (CSE) is a neurological disease with contraction and extension of limbs, leading to damage of hippocampus and cognition. This study aimed to explore the effects of dexmedetomidine (DEX) on the cognitive function and neuroinflammation in CSE rats. All rats were divided into control group, CSE group and DEX group. Morris water maze test was used to measure cognitive function. Acute hippocampal slices were made to detect long-term potentiation (LTP). Immunohistochemistry was used to determine the expression of α7-nicotinic acetylcholine receptor (α7-nAChR) and interleukin-1β (IL-1β). Enzyme-linked immunosorbent assay (ELISA) was used to measure serum levels of IL-1β, tumor necrosis factor-α (TNF-α), S-100β and brain-derived neurotrophic factor (BDNF). Our results showed that DEX improved the memory damage caused by CSE. DEX reduced seizure severity and increased the amplitudes and sustainable time of LTP, and also inhibited the hippocampal expression of α7-nAChR and IL-1β in CSE rats. DEX treatment decreased serum IL-1β, TNF-α and S-100β levels and increased BDNF levels. The effects of DEX on seizure severity and LTP could be simulated by nicotine or attenuated by concurrent α-bungarotoxin (α-BGT) treatment. In conclusions, DEX significantly improved spatial cognitive dysfunction, reduced seizure severity and increased LTP in CSE rats. Improvements by DEX were closely related to enhancement of cholinergic anti-inflammatory pathway.

60 APPLIED LIFE SCIENCES↗

Temporal expression profiling of plasma proteins reveals oxidative stress in early stages of Type 1 Diabetes progression

We report that blood markers other than islet autoantibodies are greatly needed to indicate the pancreatic beta cell destruction process as early as possible, and more accurately reflect the progression of Type 1 Diabetes Mellitus (T1D). To this end, a longitudinal proteomic profiling of human plasma using TMT-10plex-based LC-MS/MS analysis was performed to track temporal proteomic changes of T1D patients (n = 11) across 9 serial time points, spanning the period of T1D natural progression, in comparison with those of the matching healthy controls (n = 10). To our knowledge, the current study represents the largest (> 2000 proteins measured) longitudinal expression profiles of human plasma proteome in T1D research. By applying statistical trend analysis on the temporal expression patterns between T1D and controls, and Benjamini-Hochberg procedure for multiple-testing correction, 13 protein groups were regarded as having statistically significant differences during the entire follow-up period. Moreover, 16 protein groups, which play pivotal roles in response to oxidative stress, have consistently abnormal expression trend before seroconversion to islet autoimmunity. Importantly, the expression trends of two key reactive oxygen species-decomposing enzymes, Catalase and Superoxide dismutase were verified independently by ELISA.

59 BASIC BIOLOGICAL SCIENCES↗

Towards quantifying the role of exact exchange in the prediction hydrogen bond spin-spin coupling constants involving fluorine

The effect of a fraction of Hartree-Fock exchange on the calculated spin-spin coupling constants involving fluorine through a hydrogen bond is analyzed in detail. Coupling constants calculated using wavefunction methods are revisited in order to get high-level calculations using the same basis set. Accurate MCSCF results are obtained using an additive approach. These constants and their contributions are used as a reference for density functional calculations. Within the density functional theory, the Hartree-Fock exchange functional is split in short- and long-range using a modified version of the Coulomb-attenuating method with the SLYP functional as well as with the original B3LYP. Results support the difficulties for calculating hydrogen bond coupling constants using density functional methods when fluorine nuclei are involved. Coupling constants are very sensitive to the Hartree-Fock exchange and it seems that, contrary to other properties, it is important to include this exchange for short-range interactions. Best functionals are tested in two different groups of complexes: those related with anionic clusters of type [F(HF){sub n}]{sup −} and those formed by difluoroacetylene and either one or two hydrogen fluoride molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as used in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-05: Delineating High-Dose Clinical Target Volumes for Head and Neck Tumors Using Machine Learning Algorithms

Purpose: To develop and test population-based machine learning algorithms for delineating high-dose clinical target volumes (CTVs) in H&N tumors. Automating and standardizing the contouring of CTVs can reduce both physician contouring time and inter-physician variability, which is one of the largest sources of uncertainty in H&N radiotherapy. Methods: Twenty-five node-negative patients treated with definitive radiotherapy were selected (6 right base of tongue, 11 left and 9 right tonsil). All patients had GTV and CTVs manually contoured by an experienced radiation oncologist prior to treatment. This contouring process, which is driven by anatomical, pathological, and patient specific information, typically results in non-uniform margin expansions about the GTV. Therefore, we tested two methods to delineate high-dose CTV given a manually-contoured GTV: (1) regression-support vector machines(SVM) and (2) classification-SVM. These models were trained and tested on each patient group using leave-one-out cross-validation. The volume difference(VD) and Dice similarity coefficient(DSC) between the manual and auto-contoured CTV were calculated to evaluate the results. Distances from GTV-to-CTV were computed about each patient’s GTV and these distances, in addition to distances from GTV to surrounding anatomy in the expansion direction, were utilized in the regression-SVM method. The classification-SVM method used categorical voxel-information (GTV, selected anatomical structures, else) from a 3×3×3cm3 ROI centered about the voxel to classify voxels as CTV. Results: Volumes for the auto-contoured CTVs ranged from 17.1 to 149.1cc and 17.4 to 151.9cc; the average(range) VD between manual and auto-contoured CTV were 0.93 (0.48–1.59) and 1.16(0.48–1.97); while average(range) DSC values were 0.75(0.59–0.88) and 0.74(0.59–0.81) for the regression-SVM and classification-SVM methods, respectively. Conclusion: We developed two novel machine learning methods to delineate high-dose CTV for H&N patients. Both methods showed promising results that hint to a solution to the standardization of the contouring process of clinical target volumes. Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗