Search NASA⌕ Search

SEARCH · Search NASA

Results for “in situ instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Sensitive Amino Acid Composition and Chirality Analysis with the Mars Organic Analyzer (MOA)

Detection of life on Mars requires definition of a suitable biomarker and development of sensitive yet compact instrumentation capable of performing in situ analyses. Our studies are focused on amino acid analysis because amino acids are more resistant to decomposition than other biomolecules, and because amino acid chirality is a well-defined biomarker. Amino acid composition and chirality analysis has been previously demonstrated in the lab using microfabricated capillary electrophoresis (CE) chips. To analyze amino acids in the field, we have developed the Mars Organic Analyzer (MOA), a portable analysis system that consists of a compact instrument and a novel multi-layer CE microchip.

Skelley, Alison M.↗

Detection of Organic Constituents Including Chloromethylpropene in the Analyses of the ROCKNEST Drift by Sample Analysis at Mars (SAM)

key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.

Eigenbrode, J. L.↗

In situ ozone measurements for the airborne arctic stratospheric experiment

The research provided in-situ ozone measurements onboard the NASA Ames DC-8 research aircraft during the 1989 Airborne Arctic Stratospheric Experiment. The Ames DC-8 and ER-2 aircraft performed extensive sampling of the Arctic stratosphere and troposphere in a program designed to study those factors important in ozone depletion in the Arctic during times when the polar vortex and meteorology are conducive to the formation of polar stratospheric clouds and/or an Arctic ozone hole. The DC-8 ozone instrument complement included in-situ measurements for H2O, NO, NO2, NO(y) gas, NO(y) particulate, as well as remote sensors for measuring the vertical distribution and column density of ozone above the aircraft altitude. The in-situ data (ozone, water vapor, and nitrogen species) at the aircraft altitude provide a definition of tropospheric conditions in the vicinity of the polar vortex and polar stratospheric clouds. Defining tropospheric conditions will assist in the understanding of the chemistry of both stratosphere and troposphere and the extent to which polar stratospheric clouds affect the chemistry of transported air.

Gregory, Gerald L.↗

In Situ Measurements of Ammonia In Plumes Emitted From Wildfires And Agricultural Fires in the US

Emissions of trace gases and particles from fires have a major impact on climate, visibility, air quality, and public health. Biomass burning emissions include reactive nitrogen gases, among which ammonia (NH3) plays a prominent role. NH3 is a short-lived gas that acts as precursor for secondary inorganic aerosols. This process is still poorly constrained in downwind fire plumes. In summer 2019, NASA and NOAA carried out the joint airborne FIREX-AQ (Fire Influence on Regional to global Environments and Air Quality) mission over the continental US to sample plumes from wildfires and agricultural fires. On board the NASA DC-8, we used a modified PTR-ToF-MS instrument for measuring NH3 in situ and at high time resolution. Over the course of the mission, we collected a large set of NH3 data in plumes emitted from fires differing in fuel type and burning stage. Herein, we will present the measured NH3 emissions ratios and factors, compare them with the literature, and investigate the dependence of NH3 emissions on fuel type and burning conditions.

ammonia↗

Tropospheric Carbon Monoxide Measurements from the Scanning High-resolution Interferometer Sounder on 7 September 2000 in Southern Africa during SAFARI 2000

Retrieved tropospheric carbon monoxide (CO) column densities are presented for more than 9000 spectra obtained by the University of Wisconsin-Madison (UWis) Scanning High-Resolution Interferometer Sounder (SHIS) during a flight on the NASA ER-2 on 7 September 2000 as part of the Southern African Regional Science Initiative (SAFARI 2000) dry season field campaign. Enhancements in tropospheric column CO were detected in the vicinity of a controlled biomass burn in the Timbavati Game Reserve in northeastern South Africa and over the edge of the river of smoke in south central Mozambique. Relatively clean air was observed over the far southern coast of Mozambique. Quantitative comparisons are presented with in situ measurements from five different instruments flying on two other aircraft: the University of Washington Convair-580 (CV) and the South African Aerocommander JRB in the vicinity of the Timbavati fire. Measured tropospheric CO columns (extrapolated from 337 to 100 mb) of 2.1 x 10(exp 18) per square centimeter in background air and up to 1.5 x 10(exp 19) per square centimeter in the smoke plume agree well with SHIS retrieved tropospheric CO columns of (2.3 plus or minus 0.25) x 10(exp 18) per square centimeter over background air near the fire and (1.5 plus or minus 0.35) x 10(exp 19) per square centimeter over the smoke plume. Qualitative comparisons are presented with three other in situ CO profiles obtained by the South African JRA aircraft over Mozambique and northern South Africa showing the influence of the river of smoke.

McMillan, W. W.↗

An alpha particle instrument with alpha, proton, and X-ray modes for planetary chemical analyses

The interaction of alpha particles with matter is employed in a compact instrument that could provide rather complete in-situ chemical analyses of surfaces and thin atmospheres of extraterrestrial bodies. The instrument is a miniaturized and improved version of the Surveyor lunar instrument. The backscattering of alpha particles and (alpha, p) reactions provide analytical data on the light elements (carbon-iron). An X-ray mode that detects the photons produced by the alpha sources provides sensitivity and resolution for the chemical elements heavier than about silicon. The X-rays are detected by semiconductor detectors having a resolution between 150 and 250 eV at 5.9 keV. Such an instrument can identify and determine with good accuracy 99 percent of the atoms (except hydrogen) in rocks. For many trace elements, the detecting sensitivity is a few ppm. Auxiliary sources could be used to enhance the sensitivities for elements of special interest. The instrument could probably withstand the acceleration involved in semi-hard landings.

Economou, T. E.↗

Retrievals of Cloud Droplet Size from the RSP Data: Validation Using in Situ Measurements

We present comparisons of cloud droplet size distributions retrieved from the Research Scanning Polarimeter (RSP) data with correlative in situ measurements made during the North Atlantic Aerosols and Marine Ecosystems Study (NAAMES). This field experiment was based at St. Johns airport, Newfoundland, Canada with the latest deployment in May - June 2016. RSP was onboard the NASA C-130 aircraft together with an array of in situ and other remote sensing instrumentation. The RSP is an along-track scanner measuring polarized and total reflectances in9 spectral channels. Its unique high angular resolution allows for characterization of liquid water droplet size using the rainbow structure observed in the polarized reflectances in the scattering angle range between 135 and 165 degrees. A parametric fitting algorithm applied to the polarized reflectances provides retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, Rainbow Fourier Transform (RFT), which allows us to retrieve the droplet size distribution (DSD) itself. The latter is important in the case of clouds with complex structure, which results in multi-modal DSDs. During NAAMES the aircraft performed a number of flight patterns specifically designed for comparison of remote sensing retrievals and in situ measurements. These patterns consisted of two flight segments above the same straight ground track. One of these segments was flown above clouds allowing for remote sensing measurements, while the other was at the cloud top where cloud droplets were sampled. We compare the DSDs retrieved from the RSP data with in situ measurements made by the Cloud Droplet Probe (CDP). The comparisons show generally good agreement with deviations explainable by the position of the aircraft within cloud and by presence of additional cloud layers in RSP view that do not contribute to the in situ DSDs. In the latter case the distributions retrieved from the RSP data were consistent with the multi-layer cloud structures observed in the correlative High Spectral Resolution Lidar (HSRL) profiles. The comparison results provide a rare validation of polarimetric droplet size retrieval techniques, which can be used for analysis of satellite data on global scale.

cloud droplets↗

Rain on snow (ROS) understudied in sea ice remote sensing: a multi-sensor analysis of ROS during MOSAiC (Multidisciplinary drifting Observatory for the Study of Arctic Climate)

Abstract. Arctic rain on snow (ROS) deposits liquid water onto existing snowpacks. Upon refreezing, this can form icy crusts at the surface or within the snowpack. By altering radar backscatter and microwave emissivity, ROS over sea ice can influence the accuracy of sea ice variables retrieved from satellite radar altimetry, scatterometers, and passive microwave radiometers. During the Arctic Ocean MOSAiC (Multidisciplinary drifting Observatory for the Study of Arctic Climate) expedition, there was an unprecedented opportunity to observe a ROS event using in situ active and passive microwave instruments similar to those deployed on satellite platforms. During liquid water accumulation in the snowpack from rain and increased melt, there was a 4-fold decrease in radar energy returned at Ku- and Ka-bands. After the snowpack refroze and ice layers formed, this decrease was followed by a 6-fold increase in returned energy. Besides altering the radar backscatter, analysis of the returned waveforms shows the waveform shape changed in response to rain and refreezing. Microwave emissivity at 19 and 89 GHz increased with increasing liquid water content and decreased as the snowpack refroze, yet subsequent ice layers altered the polarization difference. Corresponding analysis of the CryoSat-2 waveform shape and backscatter as well as AMSR2 brightness temperatures further shows that the rain and refreeze were significant enough to impact satellite returns. Our analysis provides the first detailed in situ analysis of the impacts of ROS and subsequent refreezing on both active and passive microwave observations, providing important baseline knowledge for detecting ROS over sea ice and assessing their impacts on satellite-derived sea ice variables.

54 ENVIRONMENTAL SCIENCES↗

LIRA: Probing the Lunar Surface for Resources.

The thermal, compositional and electrical properties of the lunar regolith, such as the triboelectric properties of lunar dust, the volatile content and the thermophysical properties of the polar regolith are essential to understand from a scientific perspective as well as for resource extraction and hazard mitigation. Understanding these properties specifically requires in situ measurement, as these properties are inherent in the ambient environment. With the Lunar In situ Regolith Analyzer (LIRA) we will combine mature surface sensor technologies from previous spacecraft missions (TECP) with new sensors (ClO4- ) and battery capability to achieve a compact in situ analysis package. The surface instrument suite is adapted for lunar conditions from a sensor developed as part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on the 2007 Mars Phoenix mission, as well as supplemental sensors. • The Thermal and Electrical Conductivity Probe (TECP), flown on MECA/Phoenix, which measures heat capacity, thermal conductivity, electrical resistance, and electrical permittivity between needles inserted into the soil. The TECP also measured atmospheric humidity, a capability that will be retained to search for subsurface H2O ice. The Mars TECP weighed 100-gram and by definition was at TRL 9. The lunar version (LIRA) is TRL 4. • The Perchlorate (ClO4) sensor is based on the fluorescence property of perchlorate (Mg, Fe, Na). We added a light source to excite the perchlorate (ClO4) and a photo diode to collect the emission wavelength. A sun-shade over the photo diode blocks out the ambient light during day light hours. The unifying goal of LIRA is to deliver a complete, integrated experiment suite that investigates properties that must be measured in situ, and provides the capability to power the suite at night or in PSRs, as well as a means to simulate aspects of the diurnal transition by delivering an optical pulse to the surface with intensity comparable to sunlight. We describe the scientific context of LIRA, touching on the electrical state of the near-surface environment, the thermal properties of the undisturbed regolith, and the distribution, geochemistry, and mobility of water. We also address the exploration implications of the work, examining hazards and resources in the context of strategic knowledge gaps (SKGs).

Heather Smith↗

Preparation and analysis of particulate metal deposits

Small particles and clusters of palladium were grown by deposition from the vapor phase under ultrahigh vacuum conditions. Amorphous and crystalline support films of Al2O3 and ultrathin amorphous carbon films were used as substrate materials. The growth of the metal deposit was monitored in situ by scanning transmission diffraction of energy-filtered 100 kV electrons and high resolution transmission electron microscopy (TEM) analysis was performed in a separate instrument. It was established by in situ TEM, however, that the transfer of specimens in this case did not unduly affect the size and distribution of deposit particles. It was found that the cleanness, stoichiometry, crystallinity and structural perfection of the support surface play an essential role in determining the crystalline perfection and structure of the particles. The smallest palladium clusters reproducibly prepared contained not more than six atoms but size determinations below 1 nm average particle diameter are very problematic with conventional TEM. Palladium particles grown on carbon supports feature an impurity-stabilized mosaic structure.

Poppa, H.↗

The Hummingbird GC-IMS: In Situ Analysis of a Cometary Nucleus

Comets are of enormous scientific interest for many reasons. They are primitive bodies that date back to the earliest stages of solar system formation and, because of their small size and because they have been stored in the outer reaches of the solar system, their pristine nature has been preserved better than for any other class of body. They are extremely rich in highly volatile elements, many in the form of ices, and are richer in organic matter than any other known solar system body. It is strongly suspected that in addition to their content of primordial solar nebular material, they also incorporate unprocessed matter from the interstellar medium. Impacts by comets occur onto all the planets and satellites, often with major consequences (e.g., the dinosaur extinction event at the KIT boundary), or sometimes just providing a spectacular cosmic event (e.g., the collision of comet Shoemaker-Levy 9 with Jupiter). A mission to analyze a cometary nucleus must be capable of detecting and identifying over 30 molecular species among several different chemical groups. The Hummingbird Mission will rendezvous with, orbit, characterize, and make multiple descents to the nucleus of a comet. Hummingbird will employ a Gas Chromatograph - Ion Mobility Spectrometer (GC-IMS) as part-of a suite of sophisticated instruments for a comprehensive in situ elemental, molecular, and isotopic analysis of the comet.

Kojiro, Daniel R.↗

The Relationship Of Size Distributions To Spectral (300 - 700 Nm) Extinction Parameterization Of Ambient In Situ Aerosols Measured During FIREX-AQ And The Influence Of Aerosol Composition

Hyperspectral (300 - 700 nm, 0.7 nm resolution) aerosol extinction spectra were measured at seven fires in six states in the western United States during the Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) field campaign in July and August 2019. Obtained using an in situ aerosol sampling method, these spectra are directly comparable to other in situ aerosol measurements such as size distribution and composition. A previous deployment of the in situ Spectral Aerosol Extinction (SpEx) instrument that measured fine mode aerosols (50% size cut of 1.3 µm particle diameter) around the Korean peninsula showed that over this spectral range 2nd order polynomials provided a better fit to the logarithmically transformed spectra than linear fits (representative of Ångström exponents). The two fit parameters (a1, a2) of the polynomials are related to the classic Ångström exponent but provide additional information via their two-dimensional parameter space. The previous work was limited by the lack of commensurate size distribution information. Here, using the FIREX-AQ spectra set it is possible to expand on the previous analysis in three specific ways: 1) size distribution information is available to further elucidate how size distribution maps into (a1, a2) space, 2) the sampled size distributions include larger particles than the Korean study, and 3) the FIREX-AQ data set exhibits smoke-related spectral features in the UV part of the spectrum that are not present in background air nor were they observed previously in the Korean study. The UV spectral features are particularly intriguing as they likely arise from the absorption component of the extinction measurement and therefore may be related to composition. The relationships between the ambient in situ aerosol size distributions, the extinction spectra, and composition will be presented.

Carolyn Jordan↗

Winds and wind shear in-situ sensors

The problem of development of instrumentation for providing wind speed and direction information directly or indirectly to a pilot in the cockpit is considered. The pilots need for horizontal wind information at various stages of flight (i.e., at liftoff, in approach and departure corridors, and even in flight outside the terminal area) are emphasized.

Goff, R. C.↗

Design and Operation of the Planetary In-Situ Capillary Electrophoresis System (PISCES)

The PISCES instrument is a portable, miniature, modular instrument designed to analyze organic molecular signatures of life. PISCES uses microcapillary electrophoresis (μCE) with laser-induced fluorescence detection (LIFD) to analyze fluorescently-labeled analytes prepared on a multi-layer microfluidic chip. As a modular instrument composed of five independently functioning units, each module can be easily detached from the system and used for subsystem testing in different environments, e.g. low temperature. The pneumatic module contains mechanical and electrical components necessary to control pneumatically-actuated valves for on-chip sample processing. A prototype LabVIEW program and two custom printed circuit boards (PCBs) operate the pneumatics module using an Arduino microcontroller, and a tentative design for the module’s housing has been developed. The high-voltage module contains circuitry required to apply varying electrical potentials to the electrophoretic channel of the microdevice. Work is currently being done to design the circuit and PCB for this module in collaboration with our SBIR partners at Los Gatos Research. The optical electronics module contains the spectrometer, laser, and laser power supply. The mounting components for the electronics and housing for the module have been designed, assembled, and tested. The optical module contains optical components to focus the laser to a 20μm spot in the center of the electrophoretic channel.The housing for this module has been designed and assembled with the aligned optical components inside.

Willis, Peter A.↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗

Bayesian stability and force modeling for uncertain machining processes

Accurately simulating machining operations requires knowledge of the cutting force model and system frequency response. However, this data is collected using specialized instruments in an ex-situ manner. Bayesian statistical methods instead learn the system parameters using cutting test data, but to date, these approaches have only considered milling stability. This paper presents a physics-based Bayesian framework which incorporates both spindle power and milling stability. Initial probabilistic descriptions of the system parameters are propagated through a set of physics functions to form probabilistic predictions about the milling process. The system parameters are then updated using automatically selected cutting tests to reduce parameter uncertainty and identify more productive cutting conditions, where spindle power measurements are used to learn the cutting force model. The framework is demonstrated through both numerical and experimental case studies. Results show that the approach accurately identifies both the system natural frequency and cutting force model.

42 ENGINEERING↗

The Atmospheric Carbon and Transport (ACT)-America Mission

The Atmospheric Carbon and Transport (ACT)-America NASA Earth Venture Suborbital Mission set out to improve regional atmospheric greenhouse gas (GHG) inversions by exploring the intersection of the strong GHG fluxes and vigorous atmospheric transport that occurs within the midlatitudes. In this study, two research aircraft instrumented with remote and in situ sensors to measure GHG mole fractions, associated trace gases, and atmospheric state variables collected 1,140.7 flight hours of research data, distributed across 305 individual aircraft sorties, coordinated within 121 research flight days, and spanning five 6-week seasonal flight campaigns in the central and eastern United States. Flights sampled 31 synoptic sequences, including fair-weather and frontal conditions, at altitudes ranging from the atmospheric boundary layer to the upper free troposphere. The observations were complemented with global and regional GHG flux and transport model ensembles. We found that midlatitude weather systems contain large spatial gradients in GHG mole fractions, in patterns that were consistent as a function of season and altitude. We attribute these patterns to a combination of regional terrestrial fluxes and inflow from the continental boundaries. These observations, when segregated according to altitude and air mass, provide a variety of quantitative insights into the realism of regional CO 2 and CH 4 fluxes and atmospheric GHG transport realizations. The ACT-America dataset and ensemble modeling methods provide benchmarks for the development of atmospheric inversion systems. As global and regional atmospheric inversions incorporate ACT-America’s findings and methods, we anticipate these systems will produce increasingly accurate and precise subcontinental GHG flux estimates.

54 ENVIRONMENTAL SCIENCES↗