Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnection application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Describing Function Analysis of Transformer Magnetizing Inductance for Direct Power Control of Back-to-Back Modular Multilevel Converters with Advanced Grid Support

This paper provides a detailed investigation into the application of describing function-based analysis for assessing transformer magnetizing inductance and its impact on system performance. The focus is on a back-to-back modular multilevel converter architecture, designed to interconnect systems operating at different frequencies. The study explores the implementation of a Direct Power Control strategy, examining its effects on transformer magnetizing inductance saturation and offering effective mitigation techniques. Furthermore, the integration of advanced grid support functionalities is highlighted, demonstrating how these enhancements bolster the converter's ability to improve grid stability and power quality, positioning it as a robust solution for modern power systems. The proposed approach is validated through extensive computer simulations based MAT LAB/Simulink domain, supported by significant case study results, confirming its practical effectiveness.

back-to-back modular multilevel converters (B2B- M↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

HPC Interconnection Networks: The Key to Exascale Computing

Scientists from many domains desire to address problems within the next decade that, by all estimates, require computer systems that can achieve sustained exaflop computing rates (i.e., 1 x 10{sup 18} floating point operations per second) with real-world applications. Simply scaling existing designs is insufficient: analysis of current technological trends suggests that only a few architectural components are on track to reach the performance levels needed for exascale computing. The network connecting computer system nodes presents a particularly difficult challenge because of the prevalence of a wide variety of communication patterns and collective communication operations in algorithms used in scientific applications and their tendency to be the most significant limit to application scalability. Researchers at Oak Ridge National Laboratory and elsewhere are actively working to overcome these network-related scalability barriers using advanced hardware and software design, alternative network topologies, and performance prediction using modeling and simulation.

97 MATHEMATICS AND COMPUTING↗

Mesoporous peptide frameworks engineered from crystallizable collagen-mimetic peptide amphiphiles

The rational design of porous frameworks with tunable pore dimensions and chemical functionalities is a critical step toward their implementation in diverse applications. While traditional porous materials are typically constructed from abiotic components, there is increasing interest in employing biologically derived building blocks (e.g., peptides and proteins) that offer unmatched structural and functional diversity. Here, we report the construction of crystalline mesoporous frameworks that are self-assembled from amphiphilic collagen-mimetic peptides. Comprehensive structural characterization via microscopy, spectroscopy, and computational techniques provides insights into the assembly packing model, in which hexagonally packed channels are interconnected by antiparallel-aligned collagen triple helices via hydrophobic and electrostatic interactions. Lastly, we demonstrate the functional potential of aCMP frameworks through the encapsulation of various molecular guests, including doxorubicin, an anti-cancer drug. Overall, this work establishes a class of mesoporous frameworks, derived from synthetically engineerable peptide conjugates, marking a significant step forward in broadening the architectural scope and application potential of peptide-based materials.

Perez, Anthony R↗

Air Electrode Design for Sustained High Power Operation of Li/air Batteries

The rapid development of portable electronic devices increasingly requires much more energy to support advanced functions. However, currently available batteries do not meet the high energy requirement of these devices. Metal/air batteries, especially Li/air batteries, have a much higher specific energy than most other available batteries, but their power rate is limited by the accumulation of reaction products in the air electrode. Several approaches to improve the power rate of Li/air batteries have been analyzed in this work, including adjustment of air electrode porosity and catalyst reactivity distributions to minimize diffusion limitations and maximize air electrode material utilization. An interconnected dual pore system (one catalyzed and one noncatalyzed) is proposed to improve oxygen transport into the inner regions of the air electrode, but this approach alone cannot supply high power for long term applications. A time-release multiple catalyst approach is analyzed to provide temporal release of reactivity in the air electrode. When coupled with the dual pore configuration and catalysts with high reactivities, the time-release catalyst concept can extend the duration of higher powers to longer times, and result in maximum utilization of air electrode materials.

Williford, Ralph E↗

Synchronization of Lienard-Type Oscillators in Heterogenous Electrical Networks

Motivated by potential applications for power-electronic converters in microgrids, we study the problem of global asymptotic synchronization of Lienard-type nonlinear oscillators in heterogenous LTI electrical networks with series R-L circuits modeling interconnections. By heterogeneous, we mean that the resistance-to-inductance ratios of the lines are not all the same. Building on our previous work, we derive sufficient conditions for global asymptotic synchronization by using a first-order filter on the outputs of the oscillators. Our approach leverages a coordinate transformation to a system that emphasizes signal differences and the use of passivity based arguments to establish synchronization of the network of oscillators asymptotically. The analysis subsumes and generalizes previous conditions that have been derived for Lienard oscillators in homogeneous electrical networks. Numerical simulations are provided to validate the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CRADA 376 Final Report Development of Protective Coatings for 1 kW Hot Zone

Pacific Northwest National Laboratory (PNNL) has extensive experience in the development, fabrication, and evaluation of surface treatments and protective coatings for metallic solid oxide fuel cell (SOFC) components. For example, modified (Mn,Co)3O4 spinel coatings and coating/metal interfaces have been shown to substantially improve oxidation resistance, electrical performance, and oxide scale adhesion of ferritic stainless steel interconnects in planar SOFC stacks. At the time of the establishment of this CRADA, Protonex Technology Corporation had been working in the field of SOFC development for over 12 years and had demonstrated more than 250 thermal cycles with a less than 15 minutes start time and more than 2000 hours of continuous operation on a 250W tubular solid oxide hot zone module as part of a program for the Office of the Secretary of Defense (OSD). An industrial version of the military system, denoted P200i, had been developed that was launched at the 2015 Fuel Cell Expo in Tokyo. Feedback during beta testing of this unit was very positive. However, Protonex recognized that to transition from military markets, the commercial system would require longer life time and higher power. Leveraging their novel thermal management strategy from the tubular hot zone that allowed for rapid and repeated thermal cycling, Protonex developed a planar 1kW module aimed at the industrial and commercial market. However, more robust interconnect coatings were needed to bring the system into the 1000+ hour life time requested by customers. Therefore, PNNL’s experience and technology were engaged to enable the 1kw system to transition from military applications to commercial and industrial applications. In this CRADA, PNNL teamed with Protonex to leverage PNNL’s expertise in protective coating techniques for solid oxide fuel cell (SOFC) applications. As the first step in the collaboration, protective spinel coatings were fabricated at PNNL onto ten AISI 440 stainless steel bus bars provided by Protonex. A precursor slurry containing spinel powder was applied to the steel surfaces via an ultrasonic spray process. The coated bars were then subjected to a reducing atmosphere heat treatment (i.e., heated to 850°C at 3°C/min in a hydrogen atmosphere and held at that temperature for five hours). Five of the bars were left in this reduced condition; the other five bars were subjected to an oxidizing heat treatment (i.e., heated to 1000°C at 3°C/min in air and held at that temperature for one hour). The bars were then sent to Protonex for testing. Subsequently, Protonex decided to discontinue their SOFC development activities, so they had no further interest in continuing the collaboration with PNNL, and the CRADA activities were terminated.

30 DIRECT ENERGY CONVERSION↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

DS-GL: Advancing Graph Learning via Harnessing the Power of Nature within Dynamic Systems

With the rapid digitization of the world, an increasing number of real-world applications are turning to nonEuclidean data, modeled as graphs. Due to their intrinsic high complexity and irregularity, learning from graph data demands tremendous computational power. Recently, CMOS-compatible Ising machines, i.e., dynamic systems composed of CMOS components, have emerged as a new approach that harnesses the inherent power of natural annealing within dynamic systems to efficiently resolve binary optimization problems and have been adopted for traditional graph computation, such as max-cut. However, when performing complex Graph Learning (GL) tasks, Ising machines face significant hurdles: (i) they are inherently binary and thus ill-suited for real-valued problems; (ii) their expensive all-to-all coupling network that guarantees effective natural annealing poses daunting scalability concerns. To address these challenges, this paper proposes a nature-powered graph learning framework dubbed DS-GL, which is the first effort to transform the process of solving graph learning problems into the natural annealing process within a parameterized dynamic system embodied as a CMOS chip. To tackle the two major hurdles, DS-GL first augments the Ising machine architecture to modify the self-reaction term of its Hamiltonian function from linear to quadratic, effectively serving as an energy regulator. This adjustment maintains the system’s original physical interpretation while enabling it to process continuous, real-valued data. Second, to address the scaling issue, DS-GL further upgrades the real-valued dense Ising machine by decomposing it into a mesh-based multi-PE dynamic system that supports efficient distributed spatial-temporal co-annealing across different PEs through sparse interconnects. By exploiting the inherent sparsity and component structures in real-world graphs, DS-GL is able to map complex graph learning tasks onto the scalable dynamic system while maintaining high accuracy. Evaluations with three diverse GL applications across six real-world datasets, including traffic flow and COVID-19 prediction, show that DS-GL can deliver from 102× to 106× speedups and 500× energy reduction over Graph Neural Networks on GPUs, with 5% - 20% accuracy enhancement.

Song, Ruibing↗

UCX: An Open Source Framework for HPC Network APIs and Beyond, In: 2015 IEEE 23rd Annual Symposium on High-Performance Interconnects

This paper presents Unified Communication X (UCX), a set of network APIs and their implementations for high throughput computing. UCX comes from the combined effort of national laboratories, industry, and academia to design and implement a high-performing and highly-scalable network stack for next generation applications and systems. UCX design provides the ability to tailor its APIs and network functionality to suit a wide variety of application domains and hardware. We envision these APIs to satisfy the networking needs of many programming models such as Message Passing Interface (MPI), OpenSHMEM, Partitioned Global Address Space (PGAS) languages, task-based paradigms and I/O bound applications. To evaluate the design we implement the APIs and protocols, and measure the performance of overhead-critical network primitives fundamental for implementing many parallel programming models and system libraries. Our results show that the latency, bandwidth, and message rate achieved by the portable UCX prototype is very close to that of the underlying driver. With UCX, we achieved a message exchange latency of 0.89 us, a bandwidth of 6138.5 MB/s, and a message rate of 14 million messages per second. As far as we know, this is the highest bandwidth and message rate achieved by any network stack (publicly known) on this hardware.

Computer Science↗

Inertia estimation for power grids: A review of methods, challenges, and future prospects

The electric power grid is undergoing a significant transformation, shifting from traditional synchronous generators to inverter-based resources (IBRs) such as solar photovoltaics, wind turbines, and energy storage systems. This evolution leads to a reduction in system inertia, a critical attribute for maintaining frequency stability in response to disturbances. Consequently, the ability to monitor and estimate system inertia has become increasingly essential. This paper provides a comprehensive review of existing inertia estimation methodologies, analyzing them from multiple perspectives, including the types of data utilized, underlying estimation principles, operational modes, and system-wide applicability. A comparative summary table is included to distill commonalities and key characteristics across various studies. In addition, the paper examines practical implementations of inertia estimation across several major power systems worldwide, including the U.S. interconnections, the Nordic power system, and the U.K. grid. Key challenges are identified, particularly in estimating contributions from virtual inertia sources and load-induced inertia in increasingly converter-dominated networks. To address these emerging challenges, the paper proposes an integrated framework for real-time inertia estimation and monitoring. This framework encompasses critical components such as data acquisition, inertia estimation from both synchronous and non-synchronous sources, load-induced effects, optimization techniques, forecasting, and virtual inertia scheduling. Collectively, these elements enable dynamic, system-wide monitoring and adaptive control of grid inertia.

Inertia estimation↗

Compliant alkali silicate sealing glass for solid oxide fuel cell applications: the effect of protective YSZ coating on electrical stability in dual environment

Recently, compliant sealing glass has been proposed as a potential candidate sealant for solid oxide fuel cell (SOFC) applications. In a previous paper, the thermal stability and chemical compatibility were reported for a compliant alkali-containing silicate glass sealed between anode supported YSZ bi-layer and YSZ-coated stainless steel interconnect. In this paper, we will report the electrical stability of the compliant glass under a DC load and dual environment at 700-800 degrees C. Apparent electrical resistivity was measured with a 4-point method for the glass sealed between two plain SS441 metal coupons or YSZ-coated aluminized substrates. The results showed instability with plain SS441 at 800 degrees C, but stable behavior of increasing resistivity with time was observed with the YSZ coated SS441. In addition, results of interfacial microstructure analysis with scanning electron microscopy will be correlated with the measured resistivity results. Overall, the YSZ coating demonstrated chemically stability with the alkali-containing compliant silicate sealing glass under electrical field and dual environments.

coating↗

Efficiency and Scalability of Barrier Synchronization on NoC Based Many-core Architectures

Interconnects based on Networks-on-Chip are an appealing solution to address future microprocessor designs where, very likely, hundreds of cores will be connected on a single chip. A fundamental role in highly parallelized applications running on many-core architectures will be played by barrier primitives used to synchronize the execution of parallel processes. This paper focuses on the analysis of the efficiency and scalability of different barrier implementations in many-core architectures based on NoCs. Several message passing barrier implementations based on four algorithms (all-to-all, master-slave, butterfly and tree) have been implemented and evaluated for a single-chip target architecture composed of a variable number of cores (from 4 to 128) and different network topologies (mesh, torus, ring, clustered-ring and fat-tree). Using a cycle-accurate simulator, we show the scalability of each barrier for every NoC topology, analyzing and comparing theoretical with real behaviors. We observed that some barrier algorithms, when implemented in hardware or software, show a different scaling behavior with respect to those theoretically expected. We evaluate the efficiency of each combination topology-barrier, demonstrating that, in many cases, simple network topologies can be more efficient than complex and highly connected topologies.

97 MATHEMATICS AND COMPUTING↗

Requirements for Defining Utility Drive Cycles: An Exploratory Analysis of Grid Frequency Regulation Data for Establishing Battery Performance Testing Standards

Battery testing procedures are important for understanding battery performance, including degradation over the life of the battery. Standards are important to provide clear rules and uniformity to an industry. The work described in this report addresses the need for standard battery testing procedures that reflect real-world applications of energy storage systems to provide regulation services to grid operators. This work was motivated by the need to develop Vehicle-to-Grid (V2G) testing procedures, or V2G drive cycles. Likewise, the stationary energy storage community is equally interested in standardized testing protocols that reflect real-world grid applications for providing regulation services. As the first of several steps toward standardizing battery testing cycles, this work focused on a statistical analysis of frequency regulation signals from the Pennsylvania-New Jersey-Maryland Interconnect with the goal to identify patterns in the regulation signal that would be representative of the entire signal as a typical regulation data set. Results from an extensive time-series analysis are discussed, and the results are explained from both the statistical and the battery-testing perspectives. The results then are interpreted in the context of defining a small set of V2G drive cycles for standardization, offering some recommendations for the next steps toward standardizing testing protocols.

25 ENERGY STORAGE↗

Automation, Autonomy & Megacities 2025: A Dark Preview

This paper extrapolates from present trends to describe very plausible – and actually quite likely – future crises playing out in multiple global cities. While predicting the future is fraught with uncertainty, much of what occurs in the scenarios that follow is fully possible today and absent a significant course change, probable in the timeframe discussed. The authors want to caveat that we are not commenting on a specific organization or technology deployment. It is not hard to find tech evangelists touting that ubiquitous and highly interconnected digital technology will bring great advances in productivity and efficiency, as well as new capabilities we cannot foresee. This paper attempts to reveal what is possible when these technologies are applied to critical infrastructure applications en masse without adequate security in densely populated cities that by their nature are less resilient than other environments. Megacities need and will deploy these new technologies to keep up with insatiable demand for energy, communications, transportation and other services, but it is important to recognize that they are also made more vulnerable by following this path .

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automation, Autonomy & Megacities 2025: A Dark Preview

This paper extrapolates from present trends to describe very plausible – and actually quite likely – future crises playing out in multiple global cities. While predicting the future is fraught with uncertainty, much of what occurs in the scenarios that follow is fully possible today and absent a significant course change, probable in the timeframe discussed. The authors want to caveat that we are not commenting on a specific organization or technology deployment. It is not hard to find tech evangelists touting that ubiquitous and highly interconnected digital technology will bring great advances in productivity and efficiency, as well as new capabilities we cannot foresee. This paper attempts to reveal what is possible when these technologies are applied to critical infrastructure applications en masse without adequate security in densely populated cities that by their nature are less resilient than other environments. Megacities need and will deploy these new technologies to keep up with insatiable demand for energy, communications, transportation and other services, but it is important to recognize that they are also made more vulnerable by following this path .

29 ENERGY PLANNING, POLICY, AND ECONOMY↗