COVID-19 pandemic ramifications on residential Smart homes energy use load profiles

The COVID-19 pandemic has significantly affected people’s behavioral patterns and schedules because of stay-at-home orders and a reduction of social interactions. Therefore, the shape of electrical loads associated with residential buildings has also changed. In this paper, we quantify the changes and perform a detailed analysis on how the load shapes have changed, and we make potential recommendations for utilities to handle peak load and demand response. Our analysis incorporates data from before and after the onset of the COVID-19 pandemic, from an Alabama Power Smart Neighborhood with energy-efficient/smart devices, using around 40 advanced metering infrastructure data points. This paper highlights the energy usage pattern changes between weekdays and weekends pre– and post–COVID-19 pandemic times. The weekend usage patterns look similar pre– and post–COVID-19 pandemic, but weekday patterns show significant changes. We also compare energy use of the Smart Neighborhood with a traditional neighborhood to better understand how energy-efficient/smart devices can provide energy savings, especially because of increased work-from-home situations. HVAC and water heating remain the largest consumers of electricity in residential homes, and our findings indicate an even further increase in energy use by these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flight Measurements of Horizontal-Tail Loads on the Bell X-5 Research Airplane at a Sweep Angle of 58.7 Deg

A flight investigation was made at altitudes of 40,000, 25,000 and 15,000 feet to determine the horizontal-tail loads of the Bell X-5 research airplane at a sweep angle of 58.7 deg over the lift range of the airplane for Mach numbers from 0.61 to 1.00. The horizontal-tail loads were found to be nonlinear with lift throughout the lift ranges tested at all Mach numbers except at a Mach number of 1.00. The balancing tail loads reflected the changes which occur in the wing characteristics with increasing angle of attack. The nonlinearities were, in general, more pronounced at the higher angles of attack near the pitch-up where the balancing tail loads indicate that the wing-fuselage combination becomes unstable. No apparent effects of altitude on the balancing tail loads were evident over the comparable lift ranges of these tests at altitudes from 40,000 feet to 15,000 feet. Comparisons of balancing tail loads obtained from flight and windtunnel tests indicated discrepancies in absolute magnitudes, but the general trends of the data agree. Some differences in absolute magnitude may be accounted for by the tail load carried inboard of the strain-gage station and the load induced on the fuselage by the presence of the tail. These loads were not measured in flight.

Reed, Robert D↗

On the effect of strain rate during the cyclic compressive loading of liquid crystal elastomers and their 3D printed lattices

Nematic liquid crystal elastomers (LCEs) are a unique class of network polymers with the potential for enhanced mechanical energy absorption and dissipation capacity over conventional network polymers because they exhibit both conventional viscoelastic behavior and soft-elastic behavior (nematic director changes under shear loading). This additional inelastic mechanism makes them appealing as candidate damping materials in a variety of applications from vibration to impact. The lattice structures made from the LCEs provide further mechanical energy absorption and dissipation capacity associated with packing out the porosity under compressive loading. Understanding the extent of mechanical energy absorption, which is the work per unit mass (or volume) absorbed during loading, versus dissipation, which is the work per unit mass (or volume) dissipated during a loading cycle, requires measurement of both loading and unloading response. Here, in this study, a bench-top linear actuator was employed to characterize the loading-unloading compressive response of polydomain and monodomain LCE polymers and polydomain LCE lattice structures with two different porosities (nominally, 62% and 85%) at both low and intermediate strain rates at room temperature. As a reference material, a bisphenol-A (BPA) polymer with a similar glass transition temperature (9 °C) as the nematic LCE (4 °C) was also characterized at the same conditions for comparing to the LCE polymers. Based on the loading-unloading stress-strain curves, the energy absorption and dissipation for each material at different strain rates (0.001, 0.1, 1, 10 and 90 s -1 ) were calculated with considerations of maximum stress and material mass/density. The strain-rate effect on the mechanical response and energy absorption and dissipation behaviors was determined. The energy dissipation ratio was also calculated from the resultant loading and unloading stress-strain curves. All five materials showed significant but different strain rate effects on energy dissipation ratio. The solid LCE and BPA materials showed greater energy dissipation capabilities at both low (0.001 s -1 ) and high (above 1 s -1 ) strain rates, but not at the strain rates in between. The polydomain LCE lattice structure showed superior energy dissipation performance compared with the solid polymers especially at high strain rates.

36 MATERIALS SCIENCE↗

Verification of Energy Reduction Effect through Control Optimization of Supply Air Temperature in VRF-OAP System

This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were then changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15–17% at a 100% load, and 4–20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen's Expanding Role in the Energy System

Realizing the vision of H2@Scale will require research and investment in efficient hydrogen production methods and upgraded infrastructure. Advances in hydrogen production will allow new applications, such as steelmaking, biofuels production, and fuel cell electric vehicles, to thrive. H2@Scale is a U.S. Dept. of Energy (DOE) initiative that brings together stakeholders to advance affordable hydrogen production, transport, storage, and utilization in multiple energy sectors. H2@Scale will improve the resiliency and reliability of the energy supply chain, increase the competitiveness of U.S. manufacturing, create jobs, and reduce emissions, thereby improving environmental sustainability. Hydrogen has a unique ability to transfer energy across time and economic sectors. The electric grid was designed so that the generated load varies with changes in demand. However, wind and solar power technologies can only generate electricity when each resource is available, making it more difficult to balance the grid. Because hydrogen production can be a large-scale controllable load, it can help address that challenge. Hydrogen can serve as a clean feedstock for diverse applications within the transportation, process industries, and energy sectors. This article describes hydrogen production, application, and infrastructure opportunities. The first part of the article discusses hydrogen production and describes current costs and potential cost reductions that could be enabled by research and development (R&D). The second section discusses key applications that take advantage of hydrogen's chemical properties and its potential as an energy carrier. The final section of the article describes the current hydrogen infrastructure and how it must grow to meet the H2@Scale vision.

08 HYDROGEN↗

Swashplate feedback control for tilt-rotor aircraft

Changes in angle of attack in system were sensed indirectly by gages which responded to strains induced in wing structure. Output signals were amplified, filtered, and used to activate swashplate actuators. System provided significant reduction in blade loads and desirable changes in hub forces and moments.

Alexander, H. R.↗

Projection Moire Interferometry for Rotorcraft Applications: Deformation Measurements of Active Twist Rotor Blades

Projection Moire Interferometry (PMI) has been used during wind tunnel tests to obtain azimuthally dependent blade bending and twist measurements for a 4-bladed Active Twist Rotor (ATR) system in simulated forward flight. The ATR concept offers a means to reduce rotor vibratory loads and noise by using piezoelectric active fiber composite actuators embedded in the blade structure to twist each blade as they rotate throughout the rotor azimuth. The twist imparted on the blades for blade control causes significant changes in blade loading, resulting in complex blade deformation consisting of coupled bending and twist. Measurement of this blade deformation is critical in understanding the overall behavior of the ATR system and the physical mechanisms causing the reduction in rotor loads and noise. PMI is a non-contacting, video-based optical measurement technique capable of obtaining spatially continuous structural deformation measurements over the entire object surface within the PMI system field-of-view. When applied to rotorcraft testing, PMI can be used to measure the azimuth-dependent blade bending and twist along the full span of the rotor blade. This paper presents the PMI technique as applied to rotorcraft testing, and provides results obtained during the ATR tests demonstrating the PMI system performance. PMI measurements acquired at select blade actuation conditions generating minimum and maximum rotor loads are provided to explore the interrelationship between rotor loads, blade bending, and twist.

Fleming, Gary A.↗

Discrete sensing and actuation in a simulation model of frequency responsive loads

Loads acting autonomously on a local frequency signal can improve the response of a power system to sudden changes in supply, demand, or both. In this paper we address the use of load for regulating frequency by using feedback control. We extend prior research that focused on continuous proportional control, whereby one assumes that the load responds instantaneously, continuously, and in direct proportion to the changing frequency. However, sensors employed in any practical system have a finite sensitivity which introduces quantization effects into the control. As a result, a critical factor in the design of such a control is the relationship between the sensitivity of the sensor and the gain of the actuator. To study this issue, our model is constructed in two parts. The continuous dynamics of the power system is coupled to discrete event models of the sensors by state events that describe the detection points available to them. The quantized signals from the sensors are transformed by the actuators into discrete changes of load which, in turn, change the frequency and thereby complete the control loop. We illustrate the model with a scenario that involves a sudden, unanticipated change in load and the combined response of the control and power system to recover from the event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Age-aware constitutive materials model for a 3D printed polymeric foam

Abstract Traditional open or closed-cell stochastic elastomeric foams have wide-ranging applications in numerous industries: from thermal insulation, shock absorbing/gap-filling support cushions, packaging, to light-weight structural and positional components. Recent developments in 3D printing technologies by direct ink-write have opened the possibility of replacing stochastic foam parts by more controlled printed micro-structures with superior stress-distribution and longer functional life. For successful deployment as mechanical support or structural components, it is crucial to characterize the response of such printed materials to long-term external loads in terms of stress-strain behavior evolution and in terms of irreversible structural and load-bearing capacity changes over time. To this end, here we report a thermal-age-aware constitutive model for a 3D printed close-packed foam structure under compression. The model is based on the Ogden hyperfoam strain-energy functional within the framework of Tobolsky two-network scheme. It accurately describes experimentally measured stress-strain response, compression set, and load retention for various aging times and temperatures. Through the technique of time-temperature-superposition the model enables the prediction of long-term changes along with the quantification of uncertainty stemming from sample-to-sample variation and measurement noise. All aging parameters appear to possess the same Arrhenius activation barrier, which suggests a single dominant aging mechanism at the molecular/network level.

36 MATERIALS SCIENCE↗

Study on the residual stress relaxation in girth-welded steel pipes under bending load using diffraction methods

This research is dedicated to the experimental investigation of the residual stress relaxation in girth-welded pipes due to quasi-static bending loads. Ferritic-pearlitic steel pipes are welded with two passes, resulting in a characteristic residual stress state with high tensile residual stresses at the weld root. Also, four-point bending is applied to generate axial load stress causing changes in the residual stress state. These are determined both on the outer and inner surfaces of the pipes, as well as in the pipe wall, using X-ray and neutron diffraction. Focusing on the effect of tensile load stress, it is revealed that not only the tensile residual stresses are reduced due to exceeding the yield stress, but also the compressive residual stresses for equilibrium reasons. Furthermore, residual stress relaxation occurs both parallel and perpendicular to the applied load stress.

36 MATERIALS SCIENCE↗

A simulation evaluation of a pilot interface with an automatic terminal approach system

The pilot-machine interface with cockpit automation is a critical factor in achieving the benefits of automation and reducing pilot blunders. To improve this interface, an automatic terminal approach system (ATAS) was conceived that can automatically fly a published instrument approach by using stored instrument approach data to automatically tune airplane radios and control an airplane autopilot and autothrottle. The emphasis in the ATAS concept is a reduction in pilot blunders and work load by improving the pilot-automation interface. A research prototype of an ATAS was developed and installed in the Langley General Aviation Simulator. A piloted simulation study of the ATAS concept showed fewer pilot blunders, but no significant change in work load, when compared with a baseline heading-select autopilot mode. With the baseline autopilot, pilot blunders tended to involve loss of navigational situational awareness or instrument misinterpretation. With the ATAS, pilot blunders tended to involve a lack of awareness of the current ATAS mode state or deficiencies in the pilots' mental model of how the system operated. The ATAS display provided adequate approach status data to maintain situational awareness.

Hinton, David A.↗

Technology Enablers for Advanced Gasoline Compression Ignition Engines

To meet current emission regulations and increasingly demanding global fleet CO2 standards on fuel economy and future trends towards life cycle GHG emissions, advanced combustion engines remain significant in the passenger vehicle sector to achieve high efficiency and low emissions over the full operating range. Lean burn gasoline compression ignition (GCI) technology has shown to have the most potential in reaching these goals, although it faces challenges in the operating range. In this study, an advanced GCI engine is considered with the capability to operate under two combustion modes, namely low temperature combustion (LTC) and GCI. They are enabled with the use of two Hyundai in-house developed technologies; an advanced valve control mechanism known as continuously variable valve duration (CVVD) and a high-pressure gasoline injection system. At low load, the engine utilizes dual CVVD and dual CVVT (continuously variable valve timing) mechanisms for both intake and exhaust valvetrains to enable NVO (negative valve overlap) to trap hot residuals. The hot residuals enable low load auto-ignition, and the phasing control of that auto-ignition is achieved by varying the degrees of NVO, and in turn, the amount of hot residuals. This is done in real time with respect to the changes in engine loads or operating conditions, significantly improving cylinder-phasing control in LTC mode, and subsequently is able to realize a fuel economy gain and reduced emission benefits. Early direct injection during NVO or intake stroke is used to form homogenous or quasi-homogenous air-fuel mixture for LTC. At mid to high loads, late direct injection of gasoline or GCI mode is employed to take advantage of the high volatility and high resistance to auto-ignition of gasoline fuel, so that diesel-engine like high combustion efficiency can be achieved with lower soot emissions for the same NOx level as diesel combustion. In this paper, the key control and fueling technologies that enable this multiple mode combustion are introduced, and the resultant analysis on engine test and CFD simulation at LTC and GCI operating conditions are presented in detail.

Gasoline compression ignition, low temperature com↗

Further developments in the design and analysis of adhesive-bonded structural joints

Previously developed computer programs for analyzing stepped-lap adhesive-bonded joints and doublers have been modified to permit the inclusion of variable adhesives as well as nonuniform adherends. The new version of the analysis program is described with reference to examples illustrating the effects of load redistribution around flaws and porosity. The loss of strength associated with pinched-off edges is illustrated, and the benefits of deliberately thickening the adhesive layer in the immediate vicinity of the ends of the overlap are demonstrated. The changes in shear load transfer due to softening of some of the adhesive by moisture absorption while the remainder either has never been soaked or has dried out locally are discussed.

Hart-Smith, L. J.↗

Design and Laboratory Evaluation of Future Elongation and Diameter Measurements at the Advanced Test Reactor

New materials are being considered for fuel, cladding, and structures in next generation and existing nuclear reactors. Such materials can undergo significant dimensional and physical changes during high temperature irradiations. In order to accurately predict these changes, real-time data must be obtained under prototypic irradiation conditions for model development and validation. To provide such data, researchers at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) are developing several instrumented test rigs to obtain data real-time from specimens irradiated in well-controlled pressurized water reactor (PWR) coolant conditions in the Advanced Test Reactor (ATR). This paper reports the status of INL efforts to develop and evaluate prototype test rigs that rely on Linear Variable Differential Transformers (LVDTs) in laboratory settings. Although similar LVDT-based test rigs have been deployed in lower flux Materials Testing Reactors (MTRs), this effort is unique because it relies on robust LVDTs that can withstand higher temperatures and higher fluxes than often found in other MTR irradiations. Specifically, the test rigs are designed for detecting changes in length and diameter of specimens irradiated in ATR PWR loops. Once implemented, these test rigs will provide ATR users with unique capabilities that are sorely needed to obtain measurements such as elongation caused by thermal expansion and/or creep loading and diameter changes associated with fuel and cladding swelling, pellet-clad interaction, and crud buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

A Damage Model for the Simulation of Delamination in Advanced Composites under Variable-Mode Loading

A thermodynamically consistent damage model is proposed for the simulation of progressive delamination in composite materials under variable-mode ratio. The model is formulated in the context of Damage Mechanics. A novel constitutive equation is developed to model the initiation and propagation of delamination. A delamination initiation criterion is proposed to assure that the formulation can account for changes in the loading mode in a thermodynamically consistent way. The formulation accounts for crack closure effects to avoid interfacial penetration of two adjacent layers after complete decohesion. The model is implemented in a finite element formulation, and the numerical predictions are compared with experimental results obtained in both composite test specimens and structural components.

Turon, A.↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determination of Radiative Forcing of Saharan Dust using Combined TOMS and ERBE Data

The direct radiative forcing of Saharan dust aerosols has been determined by combining aerosol information derived from Nimbus-7 TOMS with radiation measurements observed at the top of atmosphere (TOA) by NOAA-9 ERBE made during February-July 1985. Cloud parameters and precipitable water derived from the NOAA-9 HIRS2 instrument were used to aid in screening for clouds and water vapor in the analyses. Our results indicate that under "cloud-free" and "dry" conditions there is a good correlation between the ERBE TOA outgoing longwave fluxes and the TOMS aerosol index measurements over both land and ocean in areas under the influence of airborne Saharan dust. The ERBE TOA outgoing shortwave fluxes were also found to correlate well with the dust loading derived from TOMS over ocean. However, the calculated shortwave forcing of Saharan dust aerosols is very weak and noisy over land for the range of solar zenith angle viewed by the NOAA-9 ERBE in 1985. Sensitivity factors of the TOA outgoing fluxes to changes in aerosol index were estimated using a linear regression fit to the ERBE and TOMS measurements. The ratio of the shortwave-to-longwave response to changes in dust loading over the ocean is found to be roughly 2 to 3, but opposite in sign. The monthly averaged "clear-sky" TOA direct forcing of airborne Saharan dust was also calculated by multiplying these sensitivity factors by the TOMS monthly averaged "clear-sky" aerosol index. Both the observational and theoretical analyses indicate that the dust layer height, ambient moisture content as well as the presence of cloud all play an important role in determining the TOA direct radiative forcing due to mineral aerosols.