Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Assessment Framework For Electric Distribution Systems Performance Under Extreme Conditions

The devastating impact of extreme weather-related events is increasingly evident on power grids, especially on distribution grids. The severity of their potential impact calls for 1) developing a suitable resilience assessment framework to capture the system performance and 2) assessing relevant mitigative strategies to lessen the impact of such events. This paper proposes a framework to identify grid vulnerabilities using the energy-at-risk concept to select, disconnect and isolate grid portions due to a resilience event. The proposed framework mainly consists of two steps; i) processing the utility's available infrastructure, i.e., a network model, possible switching combinations, and outage information for those combinations, as a graph-based database, and ii) implementing a novel optimal switching algorithm leveraging database and grid simulated metrics. These switching actions are generated to implement load curtailment in a rolling manner during anticipated grid scarcity conditions. In this study, a test case is created using two taxonomy feeders and is simulated against an extreme temperature event, e.g., a long, relatively cold, and prolonged freeze peak, thereby creating stress on the grid. It is demonstrated that the proposed framework allows utilities to predict the energy-at-risk during such resilience events and design suitable outage management strategies.

Poudel, Shiva↗

Energy consumption and charging load profiles from long-haul truck electrification in the United States

Abstract The urgent need to decarbonize the transportation sector combined with falling battery prices has spurred industry and policy interest in long-haul truck electrification. The charging behavior and resulting loads from electrified long-haul freight trucks are crucial for the smooth operation of the electric grid and have far-reaching environmental impacts (e.g., greenhouse gas and other air pollutant emissions). However, the aggregate energy impact of a fleetwide shift to electrified long-haul freight trucking has not been explored. This study combines electric truck design scenarios, bottom-up truck weight modeling, vehicle energy modeling, large-scale truck traffic data, and simulation of likely operation and charging behaviors to estimate end-use energy consumption and location-specific hourly charging loads for a national fleet of long-haul electric trucks. Relative to a fleet of future diesel trucks, electrification would reduce direct end-use energy consumption by 0.9 × 10 18 J (0.9 quadrillion BTU), but electrification might increase life cycle energy consumption depending on the electricity source. The electricity required to charge long-haul electric trucks is equivalent to five percent of annual electricity consumption in the United States (US). The simulated truck charging loads peak during the day across the US grid regions, but the charging peaks’ exact timing is sensitive to when trucks are dispatched for operation. The load shapes suggest that electric trucks’ charging loads can coincide with peaks in solar power generation, and planning could enable on- or off-site integration between truck charging stations and renewable electricity generation.

Tong, Fan (ORCID:0000000346613956)↗

Linear-depth quantum circuits for loading Fourier approximations of arbitrary functions

Abstract The ability to efficiently load functions on quantum computers with high fidelity is essential for many quantum algorithms, including those for solving partial differential equations and Monte Carlo estimation. In this work, we introduce the Fourier series loader (FSL) method for preparing quantum states that exactly encode multi-dimensional Fourier series using linear-depth quantum circuits. Specifically, the FSL method prepares a (Dn)-qubit state encoding the 2 Dn -point uniform discretization of aD-dimensional function specified by aD-dimensional Fourier series. A free parameter,m, which must be less thann, determines the number of Fourier coefficients, 2 D ( m + 1 ) , used to represent the function. The FSL method uses a quantum circuit of depth at most 2 ( n − 2 ) + ⌈ log 2 ( n − m ) ⌉ + 2 D ( m + 1 ) + 2 − 2 D ( m + 1 ) , which is linear in the number of Fourier coefficients, and linear in the number of qubits (Dn) despite the fact that the loaded function’s discretization is over exponentially many (2 Dn ) points. The FSL circuit consists of at most D n + 2 D ( m + 1 ) + 1 − 1 single-qubit and D n ( n + 1 ) / 2 + 2 D ( m + 1 ) + 1 − 3 D ( m + 1 ) − 2 two-qubit gates; we present a classical compilation algorithm with runtime O ( 2 3 D ( m + 1 ) ) to determine the FSL circuit for a given Fourier series. The FSL method allows for the highly accurate loading of complex-valued functions that are well-approximated by a Fourier series with finitely many terms. We report results from noiseless quantum circuit simulations, illustrating the capability of the FSL method to load various continuous 1D functions, and a discontinuous 1D function, on 20 qubits with infidelities of less than 10 −6 and 10 −3 , respectively. We also demonstrate the practicality of the FSL method for near-term quantum computers by presenting experiments performed on the Quantinuum H1-1 and H1-2 trapped-ion quantum computers: we loaded a complex-valued function on 3 qubits with a fidelity of over 95 % , as well as various 1D real-valued functions on up to 6 qubits with classical fidelities ≈99%, and a 2D function on 10 qubits with a classical fidelity ≈94%.

Physics↗

Design and Analysis of a Floating-Wind Shallow-Water Mooring System Featuring Polymer Springs

This paper presents a mooring system design featuring polymer springs for the VolturnUS-S 15-MW reference floating wind turbine in site conditions for the New York Bight at a 50-m water depth. Polymer springs have a nonlinear stress-strain curve that allows a stiffer response at low loads and a more flexible response at higher loads, potentially reducing peak mooring line tensions. The mooring dynamics model MoorDyn has been extended to model springs with nonlinear tension-strain curves from a user-inputted look-up table. This MoorDyn modeling advancement is verified against OrcaFlex simulation results. Using MoorDyn's updated capabilities, a spring-equipped catenary mooring system is designed for the 15-MW floating system, along with a baseline catenary mooring system that does not use polymer springs. The floating wind turbine simulator OpenFAST is used to simulate the mooring systems in design-driving load cases to show the effect of polymer springs on key dynamic behaviours. The results show that the spring-equipped design reduces peak tensions by up to 60%, whereas the turbine offsets stay within a maximum of 7.2 m, which is still a reasonable offset limit for cable considerations. The reduction in peak tensions results in a significant decrease in damage equivalent loads - on the order of 50% for upwind lines in fully loaded conditions. These results show that polymer springs can effectively reduce peak tensions and fatigue loads in mooring systems at shallow water depths.

floating offshore wind↗

Design and Analysis of a Floating-Wind Shallow-Water Mooring System Featuring Polymer Springs: Preprint

In this paper, a mooring system featuring polymer springs is designed for the VolturnUS-S 15 MW reference floating wind turbine in site conditions for the New York Bight at a 50-m water depth. Polymer springs have a nonlinear stress-strain curve that allows a stiffer response at low loads and a more flexible response at higher loads, potentially reducing peak mooring line tensions. The mooring dynamics model MoorDyn has been extended to model springs with nonlinear tension-strain curves from a user-inputted look-up table. This MoorDyn modelling advancement is verified against OrcaFlex simulation results. Using MoorDyn's updated capabilities, a spring-equipped catenary mooring system is designed for the 15 MW floating system, along with a baseline catenary mooring system that does not use polymer springs. The floating wind turbine simulator OpenFAST is used to simulate the mooring systems in design-driving load cases to show the effect of polymer springs on key dynamic behaviours. The results show that the spring-equipped design reduces peak tensions by up to 60%, while the turbine offsets stay within a maximum of 7.2 m, which is still a reasonable offset limit for cable considerations. The reduction in peak tensions results in a significant decrease in damage equivalent loads, on the order of 50% for upwind lines in fully loaded conditions. These results show that polymer springs can effectively reduce peak tensions and fatigue loads in mooring systems at shallow water depths.

floating offshore wind↗

Bid-in Price-Sensitive Load: A Comparison with Fixed Load in a Realistic Test System

Bulk power systems operations, in both simulation and practice, are often built on the principle of minimizing production costs, which assumes to first order that demand is fixed and that the only degrees of freedom for balancing generation and load are supply-side unit commitment and dispatch decisions. The purpose of this report is to interrogate the value of welfare-maximizing markets that not only physically balance demand and supply but also ensure that market outcomes provide consumer value by directly maximizing welfare, defined as the value of consumption minus production costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dislocation density-based plasticity model from massive discrete dislocation dynamics database

In this work, we present a dislocation density-based strain hardening model for single crystal copper through a systematic coarse-graining analysis of more than 200 discrete dislocation dynamics (DDD) simulations of plastic deformation under uniaxial tension. The proposed constitutive model has two components: a generalized Taylor relation connecting resolved shear stresses to dislocation densities on individual slip systems, and a generalized Kocks-Mecking model for dislocation multiplication. The DDD data strongly suggests a logarithmic dependence of flow stress on the plastic shear strain rate on each slip system, and, equivalently, an exponential dependence of the plastic shear strain rate on the resolved shear stress. Hence the proposed generalized Taylor relation subsumes the Orowan relation for plastic flow. The DDD data also calls for a correction to the Kocks-Mecking model of dislocation multiplication to account for the increase of dislocation density on slip systems with negligible plastic shear strain rate. This is accomplished by allowing the multiplication rate on each slip system to include contributions from the plastic strain rates of the two coplanar slip systems. The resulting constitutive model successfully captures the strain hardening rate dependence on the loading orientation as predicted by the DDD simulations, which is also consistent with existing experiments.

36 MATERIALS SCIENCE↗

Using the Carbon Capture Simulation Initiative (CCSI) Tool to Design the Experiments in the Parametric Campaign of a Novel Compact Absorber for Carbon Capture

Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.

20 FOSSIL-FUELED POWER PLANTS↗

The Impact of Anomalous Resistivity in Vacuum Contaminant Plasmas on the Electrothermal Instability

This manuscript presents an assessment of the electrothermal instability (ETI) in the presence of anomalous resistivity (AR) in vacuum contaminant plasmas (VCP) when applied to a magnetized liner inertial fusion (MagLIF)-like load.Pulsed-power driven dielectrically coated metallic liners, like in MagLIF, experience the current-driven electrothermal instability which occurs when a material’s resistivity changes with temperature and is subject to ohmic heating. Large scale pulsed-power facilities that use magnetically insulated transmission lines (MITL) have been shown to generate low-density plasma which enters the target chamber and coalesces around the load. The low-density high-temperature vacuum contaminant plasmas (VCP) can parasitically divert current from the load through causing a short in the anode-cathode gap inside the target chamber. Resistive magnetohydrodynamic (MHD) simulations of these VCP experience unphysical runaway ohmic heating due to under predicting the resistivity by using a purely collisional resistivity model.AR provides a physics-based way to address this runaway heating through increasing the resistivity in a proportional way with the drift speed. In this work, 1D simulations probe the effect that AR in VCP has on the magnetic diffusion rate, and 2D simulations show how this effect manifests in the nonlinear striation form of the ETI for a MagLIF-like load. Beryllium and aluminum dielectrically coated liners are used for the 1D and 2D simulations in this work. The1D simulations show that a VCP causes a delay in the current delivery to the load by upwards of 8 ns at 60 ns into atypical current pulse for an 1 × 10 7 A scale pulsed-power accelerator. The 2D simulations show the delay observed in the 1D simulations is reduced substantially (4 ns) by 2D turbulence that disrupts the VCP layer early in time. Here, the 2Dsimulated ETI growth varies across AR models, more so for the beryllium liner than the aluminum liner because the beryllium liner shows an enhanced rate of penetration for the magnetic diffusion wave in comparison to the aluminum liner. The 2D simulations show the bulk dielectric thickness varies across AR models with the Davidson AR model beingthe largest and the Buneman AR model being the smallest, and in connection with the thickness the Rayleigh-Taylor bubble-spike distances varies correspondingly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and control of nuclear–renewable integrated energy systems: Dynamic system model for green electricity and hydrogen production

The need for decarbonization and diversification of energy resources has led to the development of integrated energy systems (IESs), where multiple resources supply more than one energy sector. Here, one such IES with small modular nuclear reactors and renewables (wind and solar) as generating resources, catering to the demand of the electric grid while producing hydrogen for industries, is modeled in this paper. The physics-based component models are represented using the Modelica language and interconnected to form the IES. The control and coordination of the overall system are ensured by designing a suitable control architecture composed of individual subsystem-level controls and supervisory control. The dynamic performance and the load-following capability of the IES are evaluated, while satisfying the safe operational limits of the components. Different configurations and modes of IES operation are considered, where the adaptability of the control system in the presence of varying demands and renewable generations is validated. The simulation results indicate that hydrogen as a flexible load facilitates the supply of varying grid demand. Additionally, the renewables are also accommodated into the IES owing to the flexibility of the balance of plant associated with the nuclear reactors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗

Impacts of Aerosol and Environmental Conditions on Maritime and Continental Deep Convective Systems Using a Bin Microphysical Model

A series of model simulations were conducted to investigate the effects of cloud condensation nuclei (CCN) loading and convective available potential energy (CAPE) on tropical maritime and midlatitude continental deep convection. Dynamical downscaling from global aerosol reanalysis was used to represent aerosol fields for the two convective regimes. We describe a control run and multiple sensitivity experiments using a limited-area model, employing spectral-bin cloud microphysics. The CCN loading is perturbed between the target maritime and continental conditions, roughly 40–2,000 cm -3 at 850 hPa and 1% supersaturation. Surface precipitation rates monotonically increase with increasing CCN loading for both the maritime and continental situations, while these monotonic increases are disrupted in the simulations with reduced CAPE. The increase in precipitation is in the form of convective precipitation, at the expense of stratiform precipitation. CCN increases promote increases in supercooled cloud water, in agreement with previous modeling studies. However, in the simulations investigated herein, the changes in supercooled water have different impacts on the cloud microphysics in the maritime and continental simulations. Increased supercooled water contents lead to more hail and less graupel in the continental simulation. For the maritime simulation, enhanced supercooled cloud water contents promote an increase in graupel since little or no hail is produced. This distinction is due to the difference in relative magnitudes and peak altitudes of supercooled water and snow amounts, which is further attributable to moisture and dynamical differences in the two cases.

54 ENVIRONMENTAL SCIENCES↗

Discrete Empirical Interpolation Method Based Dynamic Load Model Reduction

Dynamic load models add significant complexity to bulk power system time-domain simulations. The complexity is due to the large number of ordinary differential equations (ODEs) introduced by the dynamic load components such as induction motors. It is challenging to derive reduced-order models (ROMs) for dynamic loads due to the nonlinear functions in their governing equations. This paper applies the discrete empirical interpolation method enhanced proper orthogonal decomposition (DEIM-POD) to approximate the full dynamic load model with the ROM that minimizes the projection error of the nonlinear functions in dynamic load ODEs onto their dominant modes. This approach only requires evaluation of nonlinear functions at selected observation points. The observation points selected by DEIM also provide information for screening critical load buses where dynamic load model parameters contribute the most to the accuracy of ROM across multiple contingencies. The proposed approach is validated on IEEE 9-bus, WECC 179-bus and 2384-bus Polish systems.

bulk power system↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Coupled and Uncoupled Modeling of Floating Wind Farms with Shared Anchors

As design options for floating wind farms continue to be explored, shared (or multiline) anchors that secure mooring lines from multiple turbines remain a promising technology that can potentially reduce the number of anchors and overall mooring costs. This study evaluates two methods for analyzing the loads on shared anchors: one in which floating offshore wind turbines are simulated individually (using the software OpenFAST), and one in which an entire floating wind farm is simulated collectively (using the software FAST.Farm). A three-line shared anchor is evaluated for multiple loading scenarios in deep water, using the International Energy Agency 15 MW turbine on the VolturnUS-S semisubmersible platform. While the two methods produce broadly comparable results, the coupled wave loading on platforms within the farm results in wave force cancellations and amplifications that decrease multiline force directional ranges and increase multiline force extreme values (up to 7%) and standard deviations (up to 11%) for wave-driven load cases. The inclusion of wakes in FAST.Farm also reduces the net load on the shared anchor due to the velocity deficit, leading to larger differences between OpenFAST and FAST.Farm (up to 3% difference in mean loads) for load cases with operational turbines.

17 WIND ENERGY↗

Computational Modeling of Photovoltaic Mini-Modules Undergoing Accelerated Stress Testing

A finite element model of a four-cell photovoltaic mini-module was developed and compared to experimental results from an accelerated stress test protocol in order to validate that computational models can accurately represent their physical counterparts when subjected to mechanical loading and to assess mini-module representativeness against full scale photovoltaic modules. Deflected shapes across the simulated mini-modules were compared to measured mini-module shapes when subjected to various pressure loads. Displaced mini-module shape results constrained to the experimental protocols of 0.4 mm and 1.1 mm of displacement at the mini-module center were compared to experimental results of full-size modules subjected to module qualification test load levels of 1.0 kPa and 2.4 kPa, to assess if the bending of mini-modules was representative of full-sized modules under the load. Temperature cycling was incorporated into the model to simulate the impacts of stress due to thermal expansion of the backsheet and cells. A preliminary uncertainty analysis was performed to show how variations in material properties and geometric parameters change the simulation results.

computational modeling↗