Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

LP CO 2 Compressor Final Technical Report

This report summarizes work performed by Dresser-Rand, A Siemens Business and subcontractors, under DOE award number DE-FE0026727, in pursuit of the design, construction and test of a 10:1 pressure ratio “Low Pressure” (LP) supersonic CO 2 compressor suitable for use as a first stage in a two stage 100:1 compression system. This LP compressor, in conjunction with a corresponding 10:1 high pressure compressor, provide the overall 100:1 compression ratio required to compress CO 2 from 22 psia (as generated by a CO 2 capture system) to the 2215 psia required to transport CO 2 via a pipeline to a suitable sequestration site. The compressor demonstrates application of Dresser-Rand’s supersonic compression technology at an industrial scale using CO 2 in a closed-loop testing facility. This scope of this technical report is to summarize all phases of the program executed from August 5, 2015 to the June 30, 2018. This program included the final testing of a “high pressure” (HP) compressor that had previously been built by Dresser-Rand and the design, fabrication, assembly and test of a corresponding LP compressor. In summary, the LP compressor exceeded the target pressure ratio and efficiency goals for the program at CO 2 flowrates suitable for those expected in coal fired power plant carbon capture systems. Initial and Final Techno-Economic Analysis reports were generated to show the value this compression solution brings to carbon capture and sequestration (CC&S) systems for the Case B12B coal fired power plant model. Integration of the DATUM S compression technology into a carbon capture and sequestration system was shown to result in a 27% reduction in the Cost of Electricity for the compression system, as well as a 21,500 gallon per hour reduction in required cooling water flow for the plant.

20 FOSSIL-FUELED POWER PLANTS↗

Shuttle orbit flight control design lessons - Direction for Space Station

The Space Shuttle orbit flight control system, which operates during all exo-atmospheric flight phases, has successfully met operational requirements. Many design integration and operational issues that required resolution during development and testing provide an experience base that will benefit the development of future space systems, particularly the Space Station. To this end, the applicable Shuttle and Space Station hardware/software is reviewed with some perspective provided on how current design groundrules were derived and how issues that affected the Shuttle orbit control system design are a pathway for the Space Station. Some of the most significant lessons learned from the Shuttle are summarized, with a discussion of the effect of performance and design of hardware, including the data processing system on software structures and usage procedures. Crew interface issues and important results from man-in-the-loop tests are summarized. Problems resulting from trying to meet difficult orbital operational objectives, including some sophisticated payload operations are characterized. Several proposed Shuttle flight control design improvements, developed in response to some of the lessons learned so far, are identified. Potential application of the Shuttle design lessons and new control technologies to the Space Station are discussed.

Cox, Kenneth J.↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

An investigation of a stoppable helicopter rotor with circulation control

A stoppable helicopter rotor with circulation control was investigated in the Ames 40 by 80 foot wind tunnel. The model was tested as a rotating wing, a fixed wing, and during transition start/stop sequences. The capability of the model's control system to maintain pitch and roll moment balance during the start/stop sequence, the ability of the blades to withstand the start/stop loads, the adequacy of the control system to maintain balance in the helicopter mode, and the control system capabilities in the fixed-wind mode were assessed. Time-history data of several start/stop sequences of the X-wing rotor, and the steady-state data relating to the model as both a rotor and as a fixed-wing aircraft are presented. In addition, stability data are presented which were acquired during open-loop and closed-loop tests of the hub moment feedback control system.

Ballard, J. D.↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Gravitational waves from the big bounce

In this paper we investigate gravitational wave production during the big bounce phase, inspired by loop quantum cosmology. We consider the influence of the holonomy corrections to the equation for tensor modes. We show that they act like additional effective graviton mass, suppressing gravitational wave creation. However, such effects can be treated perturbatively. We investigate a simplified model without holonomy corrections to the equation for modes and find its exact analytical solution. Assuming the form for matter {rho}{proportional_to}a{sup -2} we calculate the full spectrum of the gravitational waves from the big bounce phase. The spectrum obtained decreases to zero for the low energy modes. On the basis of this observation we infer that this effect can lead to low cosmic microwave background (CMB) multipole suppression and gives a potential way for testing loop quantum cosmology models. We also consider a scenario with a post-bounce inflationary phase. The power spectrum obtained gives a qualitative explanation of the CMB spectra, including low multipole suppression.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Alternate Leading Edge Cutback on the Space Shuttle Main Engine Low Pressure Fuel Pump

A higher order cavitation oscillation observed in the SSME low pressure fuel pump has been eliminated in water flow testing of a modified subscale replica of the inducer. The low pressure pump was modified by removing the outboard sections of two opposing blades of the four-bladed inducer, blending the "cutback" regions into the blades at the leading edge and tip, and removing material on the suction sides to decrease the exposed leading edge thickness. The leading edge tips of the cutback blades were moved approximately 25 degrees from their previous locations, thereby increasing one blade to blade spacing, decreasing the second, while simultaneously moving the cutback tips downstream. The test was conducted in MSFC's inducer test loop at scaled operating conditions in degassed and filtered water. In addition to eliminating HOC across the entire scaled operating regime, rotating cavitation was suppressed while the range of both alternate blade and asymmetric cavitation were increased. These latter phenomena, and more significantly, the shifts between these cavitation modes also resulted in significant changes to the head coefficient at low cavitation numbers. Reverse flow was detected at a slightly larger flow coefficient with the cutback inducer and suction capability was reduced by approximately 1 velocity head at and above approximately 90% of the reference flow coefficient. These performance changes along with more intense reverse flow are consistent with poor flow area management and increased incidence in the cutback region. Although the test demonstrated that the inducer modification was successful at eliminating the higher order cavitation across the entire scaled operating regime, different, previously unobserved, cavitation oscillations were introduced and significant performance penalties were imposed.

Mulder, Andrew↗

Reactivation of the Transient Reactor Test (TREAT) Facility Neutron Radiography Program

Reactivation of the Transient Reactor Test (TREAT) Facility Neutron Radiography Program The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory designed to perform transient testing on nuclear fuel experiments and materials. A neutron radiography facility was installed with the first radiograph being produced in 1967 that utilized the indirect (or transfer) method of neutron radiography to examine irradiated nuclear fuels and experiment test loops. The TREAT neutron radiography facility performed approximately 5,000 radiographs by the spring of 1977. The original radiography facility was upgraded in 1974-1975 to correct previous deficiencies and to improve capabilities. In 1986, an upgraded aperture was installed to increase the resolution of images followed by a major reactor upgrade completed in 1988. Overall, the existing neutron radiography system was in good working order. Originally built in 1958, the TREAT Facility was in operation until it was placed in a shutdown status in 1994. Following the Fukishima disaster and seeing a need for enhanced accident tolerant fuels, the United Stated Department of Energy decided to restart the TREAT facility and resume transient operations. In November 2017, the TREAT reactor was successfully restarted and is currently performing operational testing in preparation for initial experiment irradiations and transient testing. This paper reports on efforts to reactivate the TREAT neutron radiography station. A few minor shielding and system improvement upgrades have been completed along with the installation of a dedicated room for computed radiography equipment. Detailed beam characterization work was not performed following the last reactor upgrade. To characterize the neutron beam, gold foil activation measurements were made to determine an average neutron flux and flux profile. Additional multi-foil activation measurements will be made to calculate the energy spectrum. An open beam image will be taken that will provide the information about variations in the beam profile. A series of system qualification shots will also take place to accurately determine the effective image quality and image acquisition parameters. Full operational status of the TREAT neutron radiography system is scheduled for late summer of 2018.

36 MATERIALS SCIENCE↗

Estimation of sensor measurement errors in reactor coolant systems using multi-sensor fusion

A nuclear power plant is typically instrumented with a variety of sensors to continually monitor its variables, and their sensor’s measurements may be used to assess the plant state and initiate safety actions, if needed. Errors in sensor measurements, due to factors such as calibration drifts, critically affect such state assessments. Here, we address a problem of estimating sensor errors using physics-informed machine learning methods that use measurements collected under known plant conditions. For a given sensor, we propose an information fusion method that uses measurements from other sensors to estimate its output assuming it is error-free and provides its difference from an actual measurement as an error estimate. We present the ensemble of trees and support vector machine fusers, and evaluate their performance using measurements collected over an emulated test loop of a pressurized water reactor. The plant variables are related to each other through the underlying physical laws under inertial constraints that place bounds on their derivatives, which analytically justify the applicability of machine learning methods for computing these fusers. Under twenty scenarios, we assess their sensor error estimates for pressure sensors of the heat exchanger of a reactor’s primary coolant system. Multiple types of errors are captured by both fusers under externally induced calibration drifts, blockages, minor leaks and air gaps in sensing lines, and electromagnetic interference; the root mean square error of the estimation of error is under 2.2% percent of the maximum measurement. We present generalization equations, in the framework of statistical learning theory, for these methods that characterize the confidence probability that the estimation error is bounded by a specified parameter in future test scenarios.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Complex Valve and Feed Systems

A numerical framework for analysis of complex valve systems supports testing of propulsive systems by simulating key valve and control system components in the test loop. In particular, it is designed to enhance the analysis capability in terms of identifying system transients and quantifying the valve response to these transients. This system has analysis capability for simulating valve motion in complex systems operating in diverse flow regimes ranging from compressible gases to cryogenic liquids. A key feature is the hybrid, unstructured framework with sub-models for grid movement and phase change including cryogenic cavitations. The multi-element unstructured framework offers improved predictions of valve performance characteristics under steady conditions for structurally complex valves such as pressure regulator valve. Unsteady simulations of valve motion using this computational approach have been carried out for various valves in operation at Stennis Space Center such as the split-body valve and the 10-in. (approx.25.4-cm) LOX (liquid oxygen) valve and the 4-in. (approx.10 cm) Y-pattern valve (liquid nitrogen). Such simulations make use of variable grid topologies, thereby permitting solution accuracy and resolving important flow physics in the seat region of the moving valve. An advantage to this software includes possible reduction in testing costs incurred due to disruptions relating to unexpected flow transients or functioning of valve/flow control systems. Prediction of the flow anomalies leading to system vibrations, flow resonance, and valve stall can help in valve scheduling and significantly reduce the need for activation tests. This framework has been evaluated for its ability to predict performance metrics like flow coefficient for cavitating venturis and valve coefficient curves, and could be a valuable tool in predicting and understanding anomalous behavior of system components at rocket propulsion testing and design sites.

Ahuja, Vineet↗

System identification of the Large-Angle Magnetic Suspension Test Facility (LAMSTF)

The Large-Angle Magnetic Suspension Test Facility (LAMSTF), a laboratory-scale research project to demonstrate the magnetic suspension of objects over wide ranges of attitudes, has been developed. This system represents a scaled model of a planned Large-Gap Magnetic Suspension System (LGMSS). The LAMSTF system consists of a planar array of five copper electromagnets which actively suspend a small cylindrical permanent magnet. The cylinder is a rigid body and can be controlled to move in five independent degrees of freedom. Five position variables are sensed indirectly by using infra-red light-emitting diodes and light-receiving phototransistors. The motion of the suspended cylinder is in general nonlinear and hence only the linear, time-invariant perturbed motion about an equilibrium state is considered. One of the main challenges in this project is the control of the suspended element over a wide range of orientations. An accurate dynamic model plans an essential role in controller design. The analytical model of the LAMSTF system includes highly unstable real poles (about 10 Hz) and low-frequency flexible modes (about 0.16 Hz). Projection filters are proposed to identify the state space model from closed-loop test data in time domain. A canonical transformation matrix is also derived to transform the identified state space model into the physical coordinate. The LAMSTF system is stabilized by using a linear quadratic regulator (LQR) feedback controller. The rate information is obtained by calculating the back difference of the sensed position signals. The reference inputs contain five uncorrelated random signals. This control input and the system reponse are recorded as input/output data to identify the system directly from the projection filters. The sampling time is 4 ms and the model is fairly accurate in predicting the step responses for different controllers while the analytical model has a deficiency in the pitch axis.

Huang, Jen-Kuang↗

Novel Supercritical Carbon Dioxide Power Cycle Utilizing Pressured Oxy-combustion in Conjunction with Cryogenic Compression

The team of Southwest Research Institute ® (SwRI) and Thar Energy LLC (Thar) applied technology engineering and economic analysis to evaluate two advanced oxy-combustion power cycles, the Cryogenic Pressurized Oxy-combustion Cycle (CPOC), and the Supercritical Oxy-combustion Cycle. This assessment evaluated the performance and economic cost of the two proposed cycles with carbon capture and included a technology gap analysis of the proposed technologies to determine the technology readiness level of the cycle and the cycle components. The results of the engineering and economic analysis and the technology gap analysis were used to identify the next steps along the technology development roadmap for the selected cycle. The project objectives, as outlined in the FOA, were 90% CO 2 removal at no more than a 35% increase in cost of electricity (COE) as compared to a Supercritical Pulverized Coal Plant without CO 2 capture. The supercritical oxy-combustion power cycle with 99% carbon capture achieves a COE of $\$$121/MWe. This revised COE represents a 21% reduction in cost as compared to supercritical steam with 90% carbon capture ($\$$137/MWe). However, this represents a 49% increase in the COE over supercritical steam without carbon capture ($\$$80.95/MWe), exceeding the 35% target. The supercritical oxy-combustion cycle with 99% carbon capture achieved a 37.9% HHV plant efficiency (39.3% LHV plant efficiency), when coupling a supercritical oxy-combustion thermal loop to an indirect supercritical CO 2 (sCO 2 ) power block. In this configuration, the power block achieved 48% thermal efficiency for turbine inlet conditions of 650°C and 290 atm. Power block efficiencies near 60% are feasible with higher turbine inlet temperatures, however a design tradeoff to limit firing temperature to 650°C was made in order to use austenitic stainless steels for the high temperature pressure vessels and piping and to minimize the need for advanced turbomachinery features such as blade cooling. The overall technical readiness of the supercritical oxy-combustion cycle is TRL 2, Technology Concept, due to the maturity level of the supercritical oxy-combustor for solid fuels, and several critical supporting components, as identified in the Technical Gap Analysis. The supercritical oxycombustor for solid fuels operating at pressures near 100 atm is a unique component of the supercritical oxy-combustion cycle. In addition to the low TRL supercritical oxy-combustor, secondary systems were identified that would require adaptation for use with the supercritical oxycombustion cycle. These secondary systems include the high pressure pulverized coal feed, high temperature cyclone, removal of post-combustion particulates from the high pressure cyclone underflow stream, and micro-channel heat exchangers tolerant of particulate loading. Bench scale testing was utilized to measure coal combustion properties at elevated pressures in a CO 2 environment. This testing included coal slurry preparation, visualization of coal injection into a high pressure fluid, and modification of existing test equipment to facilitate the combustion properties testing. Additional bench scale testing evaluated the effectiveness of a rotary atomizer for injecting a coal-water slurry into a fluid with similar densities, as opposed to the typical application where the high density fluid is injected into a low density fluid. The swirl type supercritical oxy-combustor was developed from initial concept to an advanced design stage through numerical simulation using FLUENT and Chemkin to model the flow through the combustor and provide initial assessment of the coal combustion reactions in the flow path. This effort enabled the initial combustor mechanical layout, initial pressure vessel design, and the conceptual layout of a pilot scale test loop. A pilot scale demonstration of the supercritical oxy-combustion cycle is proposed as the next step in the technology development. This demonstration would advance the supercritical oxy-combustion cycle and the supercritical oxy-combustor from a current TRL of 2, Technology Concept, to TRL 6, Pilot Scale System Demonstrated in a Relevant Environment, and enable the evaluation and continued refinement of the supercritical oxy-combustor and critical secondary systems.

42 ENGINEERING↗

Comparison of Calculated and Experimental Results for a Boiling/Condensing Experimental Facility

A new experimental facility is being developed for materials irradiation and testing at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR). Details of this facility have been presented before. A prototype of this facility, the Thermosyphon Test Loop (TSTL) has been built, and experimental data have been obtained and analyzed. Pretest calculations for this facility with the RELAP5-3D code have been presented previously as well as other calculations with the TRACE code. The results of both codes were very different. RELAP5-3D predicted much higher pressures and temperatures than TRACE. This paper compares calculated results with the TSTL experimental data. Comparison of calculations with the codes RELAP5-3D and TRACE with experimental data of the new TSTL facility has shown that TRACE results agree well with the data and that RELAP5-3D calculates very high pressures and temperatures. The TRACE code is well suited to model this facility and is being used for future calculations. (authors)

42 ENGINEERING↗

Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

Lekan, Jack F.↗

VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Major Modification Determination Process Utilized for Proposed Idaho National Laboratory Projects

Over the past three years, several new projects with the potential for major modifications to existing facilities have been considered for implementation at the Idaho National Laboratory (INL). These projects were designated to take place in existing nuclear facilities with existing documented safety analyses. 10 CFR 830.206 requires the contractor for a major modification to a Hazard Category 1, 2, or 3 nuclear facility to obtain Department of Energy (DOE) approval for the nuclear facility design criteria to be used for preparation of a preliminary documented safety analysis (PDSA), as well as creation and approval of the PDSA, before the contractor can procure materials or components or begin construction on the project. Given the significant effort and expense of preparation and approval of a PDSA, a major modification determination for new projects is warranted to determine if the rigorous requirements of a major modification are actually required. Furthermore, performing a major modification determination helps to ensure that important safety aspects of a project are appropriately considered prior to modification construction or equipment procurement. The projects considered for major modification status at the INL included: treatment and packaging of unirradiated, sodium-bonded highly enriched uranium (HEU) fuel and miscellaneous casting scrap in the Materials and Fuels Complex (MFC) Fuel Manufacturing Facility (FMF); post irradiation examination of Advance Fuel Cycle Initiative (AFCI) fuel in the MFC Analytical Laboratory (AL); the Advanced Test Reactor (ATR) gas test loop (GTL); and the hydraulic shuttle irradiation system (HSIS) at ATR. The major modification determinations for three of the proposed projects resulted in a negative major modification. On the other hand, the major modification determination for the GTL project concluded that the project would require a major modification. This paper discusses the process, methods, and considerations used by the INL for the four major modification determinations. Three of the four major modification determinations discussed herein were completed using the guidance specified in the draft of DOE STD-1189, “Integration of Safety into the Design Process.” DOE-STD-1189 was released as a draft document in March 2007 and provides guidance for integrating safety considerations into the early design activities for constructing new facilities or making modifications to existing nuclear facilities. The fourth major modification determination was prepared prior to the existence of DOE STD-1189 and was evaluated solely by the definition of a major modification given in 10 CFR 830.206. For all four projects, consideration was given to: • Facility hazard categorization change and material inventory • Facility footprint change with the potential to adversely affect credited safety function • New or changed processes resulting in a change to the safety basis • The use of new technology or equipment not approved for use in the facility • The need for new or revised safety basis controls • Hazards not previously evaluated in the safety basis.

10 CFR 830↗

Ordered hexagonal columnar liquid crystalline self-assembly of mesogen-free sulfonylated side-chain chiral polyethers and their high dielectric property

To achieve large spontaneous polarization for ferroelectric liquid crystalline polymers, we have designed a series of mesogen-free isotactic polyethers with sulfonylated side chains. Different from prior studies using linear alkyl side chains, in this work a methyl branch was implemented in the alkyl side chains of the chiral polyethers. As a result of the continuous twist from the methyl branches and strong dipole-dipole interactions among neighboring sulfonyl groups, a helical chain conformation with tilted side chains was achieved. When the branched side chains were short (e.g., C5) and double chirality existed in both the main chain and side chains, a crystalline structure was obtained. When the branched side chains were long (e.g., ≥ C8) and single chirality existed in the main chain, an ordered hexagonal columnar liquid crystalline phase was induced. Their high-field dielectric property was studied by electric displacement-electric field (D-E) loop tests; however, no ferroelectric behavior was observed up to 200 MV/m. It was considered that the dipole-dipole interaction among neighboring sulfonyl groups in the helical chains was too strong to allow easy ferroelectric flipping.

36 MATERIALS SCIENCE↗

A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

This study presents an overview regarding how to model/size, choose, and maintain control valves (CVs) for a reactor system thermal hydraulics experimentation—specifically simulating pipe break(s) and a loss of coolant accident (LOCA) analysis. In a thermal hydraulics test loop, CVs modulate fluid flow according to the control signal generated by the controller to control the process parameter. The selection of a CV in industrial applications involves many factors, including process diversity, safety, and reliability. Further, the key issues and challenges for performing proper mathematical modeling, installation, servicing, and calibration are also discussed for the benefit of operators and end-users. Additionally, this research includes case studies illustrating major plant-level accidents associated with the malfunctioning of valves. Therefore, the study will serve as a knowledge base or reference guide for young professionals and operators who wish to better understand process control applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗