Chemical analysis of DC745 Materials: DEV Lot 1 reinvestigation; barcodes P053387, P053388, and P053389
This report serves as a follow up to our initial development lot 1 chemical analysis report (LA-UR-16-21970). The purpose of that report was to determine whether or not certain combinations of resin lots and curing agent lots resulted in chemical differences in the final material. One finding of that report suggested that pad P053389 was different from the three other pads analyzed. This report consists of chemical analysis of P053387, P053388, and a reinvestigation of P053389 all of which came from the potentially suspect combination of resin and curing agents lot. The goal of this report is to determine whether the observations relating to P053389 were isolated to that particular pad or systemic to that combination of resin and curing agent lot. The following suite of analyses were performed on the pads: Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA), Fourier Transform Infrared Spectroscopy (FT-IR), and Solid State Nuclear Magnetic Resonance (NMR). The overall conclusions of the study are that pads P053387 and P053388 behave more consistently with the pads of other resin lot and curing agent lot combinations and that the chemical observations made regarding pad P053389 are isolated to that pad and not representative of an issue with that resin lot and curing agent lot combination.