Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

The laboratory spectrum of acetaldehyde at 1 millimeter (230-325 GHz)

The rotational spectrum of acetaldehyde (CH3CHO) in the frequency range 230-325 GHz has been measured in the laboratory using millimeter/submillimeter direct absorption spectroscopy. Over 250 transition frequencies are presented for this molecule for both A and E symmetry species in its ground (upsilon(sub t) = 0) and first excited (upsilon(sub t) = 1) torsional state, with experimental uncertainties of +/- 50 kHz. The data were fitted with a model involving an internal rotation potential function, which typically reproduces the measured frequencies to nu(sub obs) - nu(sub calc) less than or approximately 50 kHz for both ground and upsilon(sub t) = 1 state. These newly measured rest frequencies should aid in the identification of interstellar CH3CHO and in spectral line assignments for millimeter-band scans.

Barclay, W. L., Jr.↗

Physical and chemical structure of the IC 63 nebula. 1: Millimeter and far-infrared observations

We present results of a (sub)millimeter and far-infrared study of the reflection/emission nebula IC 63, located close to the BO.5p star gamma Cas. The source has been mapped in the (12)CO 2 - 1 and 3 - 2, (13)CO 2 - 1, and CS 2 - 1 lines and shows a small molecular cloud less than 1'x 2' in extent, which coincides with the brightest optical nebulosity and IRAS 100 micrometer emission. IC 63 is therefore an excellent example of a nearby (d approximately = 230 pc), edge-on photon-dominated region (PDR). Various other molecules have been observed at the peak position through their rotational transitions, in order to probe the physical parameters and to derive abundances. The measured CO, HCO(+) HCN, CS and H2CO line ratios suggest that the cloud is warm, T approximately = 50 K, and dense, n (H2) approximately = 5 x 10(exp 4)/cu cm. Excitation of molecules by electrons may play a significant role in this PDR. On the basis of these physical conditions, column densities have been determined from the observed line strengths. Several different methods are discussed to constrain the H2 column density, including the use of measured submillimeter continuum fluxes. The resulting abundances of species such as CN and CS are similar to those found in cold, dark clouds like TMC-1 and L134N. However, the abundances of other simple molecules such as HNC, HCO(+) and possibly C2H are lower by factors of at least three, probably because of the enhanced photodissociation rates at a distance of 1.3 pc from a B star. Surprisingly, only the abundance of the H2S molecule appears enhanced. More complex, volatile molecules such as CH3OH CH3CN and HNCO, and the sulfur-oxides SO and SO2 have not been found in this cloud. Limited observations of molecules in the reflection nebulea NGC 2023 are presented as well, and the resulting molecular abundances are compared with those found for IC 63.

Jansen, David J.↗

Millimeter And Submillimeter-Wave Integrated Circuits On Quartz

Proposed Quartz substrate Upside-down Integrated Device (QUID) relies on UV-curable adhesive to bond semiconductor with quartz. Integrated circuits including planar GaAs Schottky diodes and passive circuit elements (such as bandpass filters) fabricated on quartz substrates. Circuits designed to operate as mixers in waveguide circuit at millimeter and submillimeter wavelengths. Integrated circuits mechanically more robust, larger, and easier to handle than planar Schottky diode chips. Quartz substrate more suitable for waveguide circuits than GaAs substrate.

Mehdi, Imran↗

Millimeter-wave Imaging Radiometer (MIR) data processing and development of water vapor retrieval algorithms

This document describes the progress of the task of the Millimeter-wave Imaging Radiometer (MIR) data processing and the development of water vapor retrieval algorithms, for the second six-month performing period. Aircraft MIR data from two 1995 field experiments were collected and processed with a revised data processing software. Two revised versions of water vapor retrieval algorithm were developed, one for the execution of retrieval on a supercomputer platform, and one for using pressure as the vertical coordinate. Two implementations of incorporating products from other sensors into the water vapor retrieval system, one from the Special Sensor Microwave Imager (SSM/I), the other from the High-resolution Interferometer Sounder (HIS). Water vapor retrievals were performed for both airborne MIR data and spaceborne SSM/T-2 data, during field experiments of TOGA/COARE, CAMEX-1, and CAMEX-2. The climatology of water vapor during TOGA/COARE was examined by SSM/T-2 soundings and conventional rawinsonde.

Chang, L. Aron↗

A LEO concept for millimeter wave satellite communication

A conceptual 60 satellite LEO constellation for millimeter wave communication is discussed. It could be launched in segments, with the first 30 satellites providing high elevation angles for all time in the Northern latitudes between Miami and Thule. The second set of 30 satellites would complete the worldwide coverage with emphasis on high ground elevation angles in the densely populated temperate zones. Full earth searches for all time are used to generate probability density functions for elevation angle. The density functions are used to derive optimum frequencies for random elevation systems. The 55 degree average elevation angle and 14 degree standard deviation are seen to be acceptable for 0.997 rain availability in Washington, DC for the 40 to 47 GHz region. The 40 to 47 GHz region is nearly optimum, if 0.99 rain availability is acceptable.

Jackson, A. H.↗

Infrared, submillimeter, and millimeter observations of the soft gamma-ray repeaters

Soft gamma ray repeaters appear to be a new class of neutron stars. While a counterpart to SGR 0525-66 was detected uniquely in the X-ray band, SGR 1806-20 and SGR 1900+14 have unusual stellar counterparts whose spectra peak in the infrared. The infrared spectra appear to contain several components: the photospheric emission from stars dominates at shorter wavelengths; a bright point source dominates at 25 micrometers, and an extended source dominates at 60 micrometers. The longer wavelength spectra are inconsistent with mono-energetic synchrotron and black body radiation models. Recent millimeter, submillimeter and infrared observations are reviewed. A preliminary analysis of the higher resolution infrared spectra of SGR 1806-20 and SGR 1900+14 is outlined. These confirm previous observations suggesting that SGR1806-20 has an outflow and that the stars comprising the counterpart to SGR 1900+14 have very similar spectra.

Smith, I. A.↗

On-Wafer Characterization of Millimeter-Wave Antennas for Wireless Applications

The paper demonstrates a de-embedding technique and a direct on-substrate measurement technique for fast and inexpensive characterization of miniature antennas for wireless applications at millimeter-wave frequencies. The technique is demonstrated by measurements on a tapered slot antenna (TSA). The measured results at Ka-Band frequencies include input impedance, mutual coupling between two TSAs and absolute gain of TSA.

Simons, Rainee N.↗

Millimeter-Wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms

This document describes the final report of the Millimeter-wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms. Volumes of radiometric data have been collected using airborne MIR measurements during a series of field experiments since May 1992. Calibrated brightness temperature data in MIR channels are now available for studies of various hydrological parameters of the atmosphere and Earth's surface. Water vapor retrieval algorithms using multichannel MIR data input are developed for the profiling of atmospheric humidity. The retrieval algorithms are also extended to do three-dimensional mapping of moisture field using continuous observation provided by airborne sensor MIR or spaceborne sensor SSM/T-2. Validation studies for water vapor retrieval are carried out through the intercomparison of collocated and concurrent measurements using different instruments including lidars and radiosondes. The developed MIR water vapor retrieval algorithm is capable of humidity profiling under meteorological conditions ranging from clear column to moderately cloudy sky. Simulative water vapor retrieval studies using extended microwave channels near 183 and 557 GHz strong absorption lines indicate feasibility of humidity profiling to layers in the upper troposphere and improve the overall vertical resolution through the atmosphere.

Chang, L. Aron↗

Airborne Millimeter-Wave Radiometric Observations of Cirrus Clouds

This paper reports the first radiometric measurements of cirrus clouds in the frequency range of 89-325 GHz from a high-altitude aircraft flight. The measurements are conducted with a Millimeter-wave Imaging Radiometer (MIR) on board the NASA ER-2 aircraft over a region in northern Oklahoma. Aboard the same aircraft are a cloud lidar system and a multichannel radiometer operating at the visible and infrared wavelengths. The instrument ensemble is well suited for identifying cirrus clouds. It is shown that the depressions in brightness temperatures associated with a few intense cirrus clouds occur at all frequency channels of the MIR. Estimates of total ice water path of the cirrus clouds are derived from comparisons of radiative transfer calculations and observed brightness depressions.

Wang, J. R.↗

The Development of Si and SiGe Technologies for Microwave and Millimeter-Wave Integrated Circuits

Historically, microwave technology was developed by military and space agencies from around the world to satisfy their unique radar, communication, and science applications. Throughout this development phase, the sole goal was to improve the performance of the microwave circuits and components comprising the systems. For example, power amplifiers with output powers of several watts over broad bandwidths, low noise amplifiers with noise figures as low as 3 dB at 94 GHz, stable oscillators with low noise characteristics and high output power, and electronically steerable antennas were required. In addition, the reliability of the systems had to be increased because of the high monetary and human cost if a failure occurred. To achieve these goals, industry, academia and the government agencies supporting them chose to develop technologies with the greatest possibility of surpassing the state of the art performance. Thus, Si, which was already widely used for digital circuits but had material characteristics that were perceived to limit its high frequency performance, was bypassed for a progression of devices starting with GaAs Metal Semiconductor Field Effect Transistors (MESFETs) and ending with InP Pseudomorphic High Electron Mobility Transistors (PHEMTs). For each new material or device structure, the electron mobility increased, and therefore, the high frequency characteristics of the device were improved. In addition, ultra small geometry lithographic processes were developed to reduce the gate length to 0.1 pm which further increases the cutoff frequency. The resulting devices had excellent performance through the millimeter-wave spectrum.

Ponchak, George E.↗

An Airborne Conical Scanning Millimeter-Wave Imaging Radiometer (CoSMIR)

An airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) for high-altitude observations from the NASA Research Aircraft (ER-2) is discussed. The primary application of the CoSMIR is water vapor profile remote sensing. Four radiometers operating at 50 (three channels), 92, 150, and 183 (three channels) GHz provide spectral coverage identical to nine of the Special Sensor Microwave Imager/Sounder (SSMIS) high-frequency channels. Constant polarization-basis conical and cross-track scanning capabilities are achieved using an elevation-under-azimuth two-axis gimbals.

Piepmeier, J.↗

Retrievals of Column Water Vapor Using Millimeter-Wave Radiometric Measurements

Water vapor is one of the most important atmospheric constituents that has a critical impact on cloud formation (ice or liquid). It is also a source that needs to be accounted for in remote measurements of surface parameters. In the high-latitude regions, e.g., Antarctica, monitoring of the state of water vapor and its transport into and out of these regions is important towards our understanding the state of balance of ice sheets and its effect on the global sea level. The technique of retrieving low amount of column water vapor using the millimeter-wave radiometric measurements, as presented in this paper, will be very useful for these regions, especially during winter times when the atmosphere is relatively dry.

Wang, J. R.↗

An Extremely Wide Bandwidth, Low-Noise SIS Heterodyne Receiver Design for Millimeter and Submillimeter Observations

Millimeter and submillimeter heterodyne receivers using state-of-the-art SIS detectors are capable of extremely large instantaneous bandwidths with noise temperatures within a few Kelvin of the quantum limit. We present the design for a broadband, sensitive, heterodyne spectrometer under development for the Caltech Submillimeter Observatory (CSO). The 180-300 GHz double-sideband design uses a single SIS device excited by a full bandwidth, fixed-tuned waveguide probe on a silicon substrate. The IF output frequency (limited by the MMIC low noise IF preamplifier) is 6-18 GHz, providing an instantaneous RF bandwidth of 24 GHz (double-sideband). The SIS mixer conversion loss should be no more than 1-2 dB with mixer noise temperatures across the band within 10 K of the quantum limit. The single-sideband receiver noise temperature goal is 70 K. The wide instantaneous bandwidth and low noise will result in an instrument capable of a variety of important astrophysical observations beyond the capabilities of current instruments. Lab testing of the receiver will begin in the summer of 2002, and the first use on the CSO should occur in the spring of 2003.

Sumner, Matthew↗

The Millimeter-Wave Properties of Superconducting Microstrip Lines

We have developed a novel technique for making high quality measurements of the millimeter-wave properties of superconducting thin-film microstrip transmission lines. Our experimental technique currently covers the 75-100 GHz band. The method is based on standing wave resonances in an open ended transmission line. We obtain information on the phase velocity and loss of the microstrip. Our data for Nb/SiO/Nb lines, taken at 4.2 K and 1.6 K, can be explained by a single set of physical parameters. Our preliminary conclusion is that the loss is dominated by the SiO dielectric, with a temperature-independent loss tangent of 5.3 +/- 0.5 x 10(exp -3) for our samples.

Vayonakis, A.↗

The Airborne Conical Scanning Millimeter-Wave Imaging Radiometer (CoSMIR)

Results of the first science flight of the airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) for high-altitude observations from the NASA ER-2 is discussed. Imagery collected from the flight demonstrates CoSMIR's unique conical/cross-track imaging mode and provides comparison of CoSMIR measurements to those of the Special Sensor Microwave/Temperature-2 (SSM/T-2) satellite radiometer.

Piepmeier, J. R.↗

High Resolution Imaging of Circumstellar Disks at Millimeter Wavelengths

Our program uses the techniques of millimeter interferometry to make high resolution observations of dust continuum emission to study the structure of protoplanetary disks and debris disks around nearby stars. Observations of dust emission at these wavelengths are advantageous because the dust emission is generally optically thin and directly proportional to mass, and contrast with stellar photospheres is not a problem. We are using of several observational facilities, including (1) the Very Large Array (VLA) of the National Radio Astronomy Observatories, (2) the Plateau de Bure Interferometer (PdBI) of the Institut de RadioAstronomie Millimetrique, and (3) the Submillimeter Array (SMA), now under construction by the Smithsonian Astrophysical Observatory and Academia Sinica (Taiwan). In the past year, we have accomplished the following (more details below): (1) We continued work on our 'low resolution' VLA survey of disks in Herbig Ae star and binary systems, primarily to identify candidates for higher resolution follow-up. We have submitted a paper for publication on the detailed analysis of the structure of the disk around CQ Tauri; (2) We completed analysis of our PdBI observations of the debris disk around Vega, and we presented these results at (1) the 199th AAS meeting in Washington, DC, and (2) a symposium in memory of Fred Gillett on Debris Disks and the Formation of Planets, in Tucson, AZ; (3) We continue commissioning observations with the SMA, which include the first ever interferometric images in the 850 micron wavelength band, in preparation for eventually imaging debris disks.

Wilner, David J.↗

Sub-millimeter Spectroscopy of Astrophysically Interesting Metal-Containing Molecules

With the advent of SOFIA and Herschel, new spectral windows will be opened for spectroscopy in the sub-millimeter region. To conduct science in this band, laboratory measurements must be carried out to provide accurate transition frequencies for molecular identification and physical interpretation. We are presently conducting such measurements using gas-phase submm direct absorption techniques. Of particular interest are simple molecules containing iron-peak elements, including carbides, and metal hydride ions (MH+), both which possess favorable transitions at submm wavelengths.

Ziurys, L. M.↗