Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Restricting loop expansions in gauge theories coupled to matter

Highlights: • Lagrange multiplier fields are used to restrict radiative effects to one-loop order. • This approach is exemplified in the Yang-Mills theory coupled to a scalar matter field. • We showed that it can be used with the Einstein–Hilbert action coupled to matter. • The resulting quantum gravity theory is both renormalizable and unitary. Quantizing any model in which a Lagrange multiplier (LM) field is used to restrict field configurations to those that satisfy the classical equations of motion, leads to at most one-loop radiative corrections. This approach can be used with both the Yang–Mills (YM) and Einstein–Hilbert (EH) action; the resulting theory is both renormalizable and unitary, has a positive energy spectrum and has no negative norm states contributing to physical processes. Although this approach cannot be consistently used with scalar fields alone, scalar fields can be coupled to gauge fields so that loop effects in the gauge sector are restricted to one-loop order in a way that satisfies the usual criterion for a consistent quantum field theory. The tree-level diagrams are those of the classical theory in which the metric couples to the energy–momentum tensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT

Hypofractionated stereotactic body radiotherapy (SBRT) has been tested for prostate cancer radiotherapy. This study aims to investigate the dosimetric effects of intrafraction prostate motion on the target and the normal structures for SBRT. For prostate cancer patients treated with an image-tracking CyberKnife system, the intrafraction prostate movements were recorded during 50-70 min treatment time. Based on the recorded intrafraction prostate movements, treatment plans were created for these cases using intensity modulated beams while scaling the average time patterns from the CyberKnife treatment to simulate hypofractionated intensity modulated radiotherapy (IMRT) delivery. The effect of delivery time on the intrafraction organ motion was investigated. For a nominal single fraction delivery of 9.5 Gy with IMRT, we found that the dosimetric effect of the intrafraction prostate movement is case dependent. For most cases, the dose volume histograms exhibited very small changes from the treatment plans that assumed no intrafractional prostate motion when the maximum intrafraction movements were within {+-}5 mm. However, when sporadic prostate movements greater than 5 mm were present in any one direction, significant changes were found. For example, the V{sub 100%} for the prostate could be reduced by more than 10% to less than 85% of the prostate volume coverage. If these large movements could be excluded by some active correction strategies, then the average V{sub 100%} for the simulated plan could be restored to within approximately 2% of the ideal treatment plans. On average, the sporadic intrafraction motion has less dosimetric impact on the prolonged treatment delivery versus fast treatment delivery. For example, the average V{sub 100%} for the clinical target volume was reduced from the original 95.1% to 92.1{+-} 3.7% for prolonged treatment, and to 91.3{+-}5.4% when the treatment time was shortened by 50%. Due to the observed large sporadic prostate motions, we conclude that an on-line target motion monitoring and correction strategy is necessary to implement hypofractionated SBRT with intensity modulated beams for prostate cancer treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constraints on moduli cosmology from the production of dark matter and baryon isocurvature fluctuations

We set constraints on moduli cosmology from the production of dark matter - radiation and baryon -radiation isocurvature fluctuations through modulus decay, assuming the modulus remains light during inflation. We find that the moduli problem becomes worse at the perturbative level as a significant part of the parameter space m{sub {sigma}} (modulus mass) - {sigma}{sub inf} (modulus vacuum expectation value at the end of inflation) is constrained by the nonobservation of significant isocurvature fluctuations. We discuss in detail the evolution of the modulus vacuum expectation value and perturbations, in particular, the consequences of Hubble scale corrections to the modulus potential, and the stochastic motion of the modulus during inflation. We show, in particular, that a high modulus mass scale m{sub {sigma}} > or approx. 100 TeV, which allows the modulus to evade big bang nucleosynthesis constraints is strongly constrained at the perturbative level. We find that generically, solving the moduli problem requires the inflationary scale to be much smaller than 10{sup 13} GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IUE data reduction - The parameterization of the motion of the IUE reseau grids and spectral formats as a function of time and temperature

Improvements are made on IUE data reduction using corrected reseau positions and dispersion constants for temperature variations and secular effects. Models describing the motion of the high dispersion spectral format as a function of THDA alone reduce the scatter in the predicted position of a given wavelength, and scatter is further reduced when a linear dependence on time is also allowed. A correction technique is presented for early data which reduces errors in wavelength assignments from over 30 km/s to less than 3 km/s in high dispersion. The reseau temperature correction helps locate the minimum background signal, centered between the echelle orders. The residual uncertainty of 2 km/s for SWP and 2.7 km/s for LWR makes the wavelength accuracy of time and temperature corrected IUE spectra comparable to that of temperature corrected data from the Copernicus satellite.

Thompson, R. W.↗

The effect of interference on delta modulation encoded video signals

The results of a study on the use of the delta modulator as a digital encoder of television signals are presented. The computer simulation was studied of different delta modulators in order to find a satisfactory delta modulator. After finding a suitable delta modulator algorithm via computer simulation, the results are analyzed and then implemented in hardware to study the ability to encode real time motion pictures from an NTSC format television camera. The effects were investigated of channel errors on the delta modulated video signal and several error correction algorithms were tested via computer simulation. A very high speed delta modulator was built (out of ECL logic), incorporating the most promising of the correction schemes, so that it could be tested on real time motion pictures. The final area of investigation concerned itself with finding delta modulators which could achieve significant bandwidth reduction without regard to complexity or speed. The first such scheme to be investigated was a real time frame to frame encoding scheme which required the assembly of fourteen, 131,000 bit long shift registers as well as a high speed delta modulator. The other schemes involved two dimensional delta modulator algorithms.

Schilling, D. L.↗

A new method for measuring the 3D turbulent velocity dispersion of molecular clouds

ABSTRACT The structure and star formation activity of a molecular cloud are fundamentally linked to its internal turbulence. However, accurately measuring the turbulent velocity dispersion is challenging due to projection effects and observational limitations, such as telescope resolution, particularly for clouds that include non-turbulent motions, such as large-scale rotation. Here, we develop a new method to recover the 3D turbulent velocity dispersion (σv,3D) from position–position–velocity (PPV) data. We simulate a rotating, turbulent, collapsing molecular cloud, and compare its intrinsic σv,3D with three different measures of the velocity dispersion accessible in PPV space: (1) the spatial mean of the 2nd-moment map, σi, (2) the standard deviation of the gradient/rotation-corrected 1st-moment map, σ(c − grad), and (3) a combination of (1) and (2), called the ‘gradient-corrected parent velocity dispersion’, $\sigma _{\mathrm{(p}-\mathrm{grad)}}=(\sigma _{\mathrm{i}}^2+\sigma _{(\mathrm{c}-\mathrm{grad)}}^2)^{1/2}$. We show that the gradient correction is crucial in order to recover purely turbulent motions of the cloud, independent of the orientation of the cloud with respect to the line of sight. We find that with a suitable correction factor and appropriate filters applied to the moment maps, all three statistics can be used to recover σv,3D, with method 3 being the most robust and reliable. We determine the correction factor as a function of the telescope beam size for different levels of cloud rotation, and find that for a beam full width at half-maximum f and cloud radius R, the 3D turbulent velocity dispersion can best be recovered from the gradient-corrected parent velocity dispersion via $\sigma _{v,\mathrm{3D}}= \left[(-0.29\pm 0.26)\, f/R + 1.93 \pm 0.15\right] \sigma _{\mathrm{(p}-\mathrm{grad)}}$ for f/R < 1, independent of the level of cloud rotation or LOS orientation.

Stewart, Madeleine↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Digital active material processing platform effort (DAMPER), SBIR phase 2

Applied Technology Associates, Inc., (ATA) has demonstrated that inertial actuation can be employed effectively in digital, active vibration isolation systems. Inertial actuation involves the use of momentum exchange to produce corrective forces which act directly on the payload being actively isolated. In a typical active vibration isolation system, accelerometers are used to measure the inertial motion of the payload. The signals from the accelerometers are then used to calculate the corrective forces required to counteract, or 'cancel out' the payload motion. Active vibration isolation is common technology, but the use of inertial actuation in such systems is novel, and is the focus of the DAMPER project. A May 1991 report was completed which documented the successful demonstration of inertial actuation, employed in the control of vibration in a single axis. In the 1 degree-of-freedom (1DOF) experiment a set of air bearing rails was used to suspend the payload, simulating a microgravity environment in a single horizontal axis. Digital Signal Processor (DSP) technology was used to calculate in real time, the control law between the accelerometer signals and the inertial actuators. The data obtained from this experiment verified that as much as 20 dB of rejection could be realized by this type of system. A discussion is included of recent tests performed in which vibrations were actively controlled in three axes simultaneously. In the three degree-of-freedom (3DOF) system, the air bearings were designed in such a way that the payload is free to rotate about the azimuth axis, as well as translate in the two horizontal directions. The actuator developed for the DAMPER project has applications beyond payload isolation, including structural damping and source vibration isolation. This report includes a brief discussion of these applications, as well as a commercialization plan for the actuator.

Blackburn, John↗

Muon motion in titanium hydride

Motional narrowing of the transverse-field muon spin rotation signal was observed in gamma-TiH(x) for x = 1.83, 1.97, and 1.99. An analysis of the data for TiH1.99 near room temperature indicates that the mechanism responsible for the motion of the muon out of the octahedral site is thermally activated diffusion with an attempt frequency comparable to the optical vibrations of the lattice. Monte Carlo calculations to simulate the effect of muon and proton motion upon the muon field-correlation time were used to interpret the motional narrowing in TiH1.97 near 500 K. The interpretation is dependent upon whether the Bloembergen, Purcell, and Pound (BPP) theory or an independent spin-pair relaxation model is used to obtain the vacancy jump rate from proton NMR T1 measurements. Use of BPP theory shows that the field-correction time can be obtained if the rate of motion of the muon with respect to the rate of the motion for the protons is decreased. An independent spin-pair relaxation model indicates that the field-correlation time can be obtained if the rate of motion for the nearest-neighbor protons is decreased.

Kempton, J. R.↗

Investigation of television transmission using adaptive delta modulation principles

The results are presented of a study on the use of the delta modulator as a digital encoder of television signals. The computer simulation of different delta modulators was studied in order to find a satisfactory delta modulator. After finding a suitable delta modulator algorithm via computer simulation, the results were analyzed and then implemented in hardware to study its ability to encode real time motion pictures from an NTSC format television camera. The effects of channel errors on the delta modulated video signal were tested along with several error correction algorithms via computer simulation. A very high speed delta modulator was built (out of ECL logic), incorporating the most promising of the correction schemes, so that it could be tested on real time motion pictures. Delta modulators were investigated which could achieve significant bandwidth reduction without regard to complexity or speed. The first scheme investigated was a real time frame to frame encoding scheme which required the assembly of fourteen, 131,000 bit long shift registers as well as a high speed delta modulator. The other schemes involved the computer simulation of two dimensional delta modulator algorithms.

Schilling, D. L.↗

Simulation and visualization of face seal motion stability by means of computer generated movies

A computer aided design method for mechanical face seals is described. Based on computer simulation, the actual motion of the flexibly mounted element of the seal can be visualized. This is achieved by solving the equations of motion of this element, calculating the displacements in its various degrees of freedom vs. time, and displaying the transient behavior in the form of a motion picture. Incorporating such a method in the design phase allows one to detect instabilities and to correct undesirable behavior of the seal. A theoretical background is presented. Details of the motion display technique are described, and the usefulness of the method is demonstrated by an example of a noncontacting conical face seal.

Etsion, I.↗

Simulation and visualization of face seal motion stability by means of computer generated movies

A computer aided design method for mechanical face seals is described. Based on computer simulation, the actual motion of the flexibly mounted element of the seal can be visualized. This is achieved by solving the equations of motion of this element, calculating the displacements in its various degrees of freedom vs. time, and displaying the transient behavior in the form of a motion picture. Incorporating such a method in the design phase allows one to detect instabilities and to correct undesirable behavior of the seal. A theoretical background is presented. Details of the motion display technique are described, and the usefulness of the method is demonstrated by an example of a noncontacting conical face seal.

Etsion, I.↗

Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4{sup o}. For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22{sup o}). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be accurate, and its registration matrix can be easily translated into the TPS and a low dose is delivered to the patient during image acquisition. These results can help in designing imaging protocols for offline evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Isotopic studies of trans- and cis-HOCO using rotational spectroscopy: Formation, chemical bonding, and molecular structures

HOCO is an important intermediate in combustion and atmospheric processes because the OH + CO → H + CO{sub 2} reaction represents the final step for the production of CO{sub 2} in hydrocarbon oxidation, and theoretical studies predict that this reaction proceeds via various intermediates, the most important being this radical. Isotopic investigations of trans- and cis-HOCO have been undertaken using Fourier transform microwave spectroscopy and millimeter-wave double resonance techniques in combination with a supersonic molecular beam discharge source to better understand the formation, chemical bonding, and molecular structures of this radical pair. We find that trans-HOCO can be produced almost equally well from either OH + CO or H + CO{sub 2} in our discharge source, but cis-HOCO appears to be roughly two times more abundant when starting from H + CO{sub 2}. Using isotopically labelled precursors, the OH + C{sup 18}O reaction predominately yields HOC{sup 18}O for both isomers, but H{sup 18}OCO is observed as well, typically at the level of 10%-20% that of HOC{sup 18}O; the opposite propensity is found for the {sup 18}OH + CO reaction. DO + C{sup 18}O yields similar ratios between DOC{sup 18}O and D{sup 18}OCO as those found for OH + C{sup 18}O, suggesting that some fraction of HOCO (or DOCO) may be formed from the back-reaction H + CO{sub 2}, which, at the high pressure of our gas expansion, can readily occur. The large {sup 13}C Fermi-contact term (a{sub F}) for trans- and cis-HO{sup 13}CO implicates significant unpaired electronic density in a σ-type orbital at the carbon atom, in good agreement with theoretical predictions. By correcting the experimental rotational constants for zero-point vibration motion calculated theoretically using second-order vibrational perturbation theory, precise geometrical structures have been derived for both isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of a quantum logic gate in a cryogenic surface-electrode ion trap

We demonstrate quantum control techniques for a single trapped ion in a cryogenic, surface-electrode trap. A narrow optical transition of Sr{sup +} along with the ground and first excited motional states of the harmonic trapping potential form a two-qubit system. The optical qubit transition is susceptible to magnetic field fluctuations, which we stabilize with a simple and compact method using superconducting rings. Decoherence of the motional qubit is suppressed by the cryogenic environment. ac Stark shift correction is accomplished by controlling the laser phase in the pulse sequencer, eliminating the need for an additional laser. Quantum process tomography is implemented on atomic and motional states by use of conditional pulse sequences. With these techniques, we demonstrate a Cirac-Zoller controlled-not gate in a single ion with a mean fidelity of 91(1)%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seven-dimensional gravity with topological terms

We construct new seven-dimensional gravity by adding two topological terms to the Einstein-Hilbert action. For a certain choice of the coupling constants, these terms exist naturally in seven-dimensional gauged supergravity from the S{sup 4} reduction of eleven-dimensional supergravity with the R{sup 4} corrections. We derive the full set of the equations of motion. We find that the static spherically-symmetric black holes are unmodified by the topological terms. We obtain squashed AdS{sub 7}, and also squashed seven spheres and Q{sup 111} spaces in Euclidean signature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Finding polynomials of best approximation with weight

A new iterative method for finding the parameters of polynomials of best approximation with weight in C[-1, 1] is presented. It is based on the representation of the error in the trigonometric form in terms of the phase function. The iterative method of finding the corrections to the phase functions that determine the joint motion of the zeros and the e-points of the error is based on inverse analysis, perturbation theory, and asymptotic formulae for extremal polynomials. Bibliography: 24 titles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning

Purpose: Four-dimensional computed tomography (4D-CT) is commonly used to account for respiratory motion of target volumes in radiotherapy to the thorax. From the 4D-CT acquisition, a maximum-intensity projection (MIP) image set can be created and used to help define the tumor motion envelope or the internal gross tumor volume (iGTV). The purpose of this study was to quantify the differences in automatically contoured target volumes for usage in the delivery of stereotactic body radiation therapy using MIP data sets generated from one of the four methods: (1) 4D-CT phase-binned (PB) based on retrospective phase calculations, (2) 4D-CT phase-corrected phase-binned (PC-PB) based on motion extrema, (3) 4D-CT amplitude-binned (AB), and (4) cine CT built from all available images. Methods: MIP image data sets using each of the four methods were generated for a cohort of 28 patients who had prior thoracic 4D-CT scans that exhibited lung tumor motion of at least 1 cm. Each MIP image set was automatically contoured on commercial radiation treatment planning system. Margins were added to the iGTV to observe differences in the final simulated planning target volumes (PTVs). Results: For all patients, the iGTV measured on the MIP generated from the entire cine CT data set (iGTV{sub cine}) was the largest. Expressed as a percentage of iGTV{sub cine}, 4D-CT iGTV (all sorting methods) ranged from 83.8% to 99.1%, representing differences in the absolute volume ranging from 0.02 to 4.20 cm{sup 3}; the largest average and range of 4D-CT iGTV measurements was from the PC-PB data set. Expressed as a percentage of PTV{sub cine} (expansions applied to iGTV{sub cine}), the 4D-CT PTV ranged from 87.6% to 99.6%, representing differences in the absolute volume ranging from 0.08 to 7.42 cm{sup 3}. Regions of the measured respiratory waveform corresponding to a rapid change of phase or amplitude showed an increased susceptibility to the selection of identical images for adjacent bins. Duplicate image selection was most common in the AB implementation, followed by the PC-PB method. The authors also found that the image associated with the minimum amplitude measurement did not always correlate with the image that showed maximum tumor motion extent. Conclusions: The authors identified cases in which the MIP generated from a 4D-CT sorting process under-represented the iGTV by more than 10% or up to 4.2 cm{sup 3} when compared to the iGTV{sub cine}. They suggest utilization of a MIP generated from the full cine CT data set to ensure maximum inclusive tumor extent.

60 APPLIED LIFE SCIENCES↗