Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extended X-ray absorption spectroscopy using an ultrashort pulse laboratory-scale laser-plasma accelerator

Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing information on both the electronic and ionic structure simultaneously. This capability will allow the investigation of ultrafast processes, and in particular, probing high-energy-density matter and physics far-from-equilibrium where the sample refresh rate is slow and shot number is limited. For example, states that replicate the tremendous pressures and temperatures of planetary bodies or the conditions inside nuclear fusion reactions. Using high-power lasers to pump these samples also has the advantage of being inherently synchronised to the laser-driven X-ray probe. A perspective on the additional strengths of a laboratory-based ultrafast X-ray absorption source is presented.

43 PARTICLE ACCELERATORS↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength Shifting Phoswich Detectors for Superior Depth-of-Interaction Resolution

In order to simultaneously achieve both high spatial resolution and high sensitivity in small Positron Emission Tomography (PET) systems, scintillation detectors must be long in the radial direction as well as able to provide depth-of-interaction (DOI) information. DOI information is typically provided by constructing detectors from two or more layers of scintillators that are identifiable due to their different decay times. This approach has worked well in tomographs such as the High Resolution Research Tomograph (HRRT, CTI PET Systems, Inc.) in which the emission and excitation bands of the scintillator layers do not overlap each other. However, many potentially important pairs of scintillator crystals exist in which the emission of one crystal is, in fact, absorbed and re-emitted by the second crystal, thus impacting the pulse shape discrimination process used to identify the scintillator layers. These potentially useful pairs of scintillators are unlikely to be implemented in phoswich detectors without a comprehensive understanding of the complex emission that results when the light of one crystal is absorbed by the second crystal and then reemitted. Our objective is to develop a fundamental understanding of the optical phenomena that occur in phoswich detectors and to exploit these phenomena to achieve improved spatial resolution in small high sensitivity PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance comparison of dynamical decoupling sequences for a qubit in a rapidly fluctuating spin bath

Avoiding the loss of coherence of quantum mechanical states is an important prerequisite for quantum information processing. Dynamical decoupling (DD) is one of the most effective experimental methods for maintaining coherence, especially when one can access only the qubit system and not its environment (bath). It involves the application of pulses to the system whose net effect is a reversal of the system-environment interaction. In any real system, however, the environment is not static, and therefore the reversal of the system-environment interaction becomes imperfect if the spacing between refocusing pulses becomes comparable to or longer than the correlation time of the environment. The efficiency of the refocusing improves therefore if the spacing between the pulses is reduced. Here, we quantify the efficiency of different DD sequences in preserving different quantum states. We use {sup 13}C nuclear spins as qubits and an environment of {sup 1}H nuclear spins as the environment, which couples to the qubit via magnetic dipole-dipole couplings. Strong dipole-dipole couplings between the proton spins result in a rapidly fluctuating environment with a correlation time of the order of 100 {mu}s. Our experimental results show that short delays between the pulses yield better performance if they are compared with the bath correlation time. However, as the pulse spacing becomes shorter than the bath correlation time, an optimum is reached. For even shorter delays, the pulse imperfections dominate over the decoherence losses and cause the quantum state to decay.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Physical Sciences Vistas: MaRIE (draft)

To achieve breakthrough scientific discoveries in the 21st century, a convergence and integration of world-leading experimental facilities and capabilities with theory, modeling, and simulation is necessary. In this issue of Experimental Physical Sciences Vistas, I am excited to present our plans for Los Alamos National Laboratory's future flagship experimental facility, MaRIE (Matter-Radiation Interactions in Extremes). MaRIE is a facility that will provide transformational understanding of matter in extreme conditions required to reduce or resolve key weapons performance uncertainties, develop the materials needed for advanced energy systems, and transform our ability to create materials by design. Our unique role in materials science starting with the Manhattan Project has positioned us well to develop a contemporary materials strategy pushing the frontiers of controlled functionality - the design and tailoring of a material for the unique demands of a specific application. Controlled functionality requires improvement in understanding of the structure and properties of materials in order to synthesize and process materials with unique characteristics. In the nuclear weapons program today, improving data and models to increase confidence in the stockpile can take years from concept to new knowledge. Our goal with MaRIE is to accelerate this process by enhancing predictive capability - the ability to compute a priori the observables of an experiment or test and pertinent confidence intervals using verified and validated simulation tools. It is a science-based approach that includes the use of advanced experimental tools, theoretical models, and multi-physics codes, simultaneously dealing with multiple aspects of physical operation of a system that are needed to develop an increasingly mature predictive capability. This same approach is needed to accelerate improvements to other systems such as nuclear reactors. MaRIE will be valuable to many national security science challenges. Our first issue of Vistas focused on our current national user facilities (the Los Alamos Neutron Science Center [LANSCE], the National High Magnetic Field Laboratory-Pulsed Field Facility, and the Center for Integrated Nanotechnologies) and the vitality they bring to our Laboratory. These facilities are a magnet for students, postdoctoral researchers, and staff members from all over the world. This, in turn, allows us to continue to develop and maintain our strong staff across the relevant disciplines and conduct world-class discovery science. The second issue of Vistas was devoted entirely to the Laboratory's materials strategy - one of the three strategic science thrusts for the Laboratory. This strategy has helped focus our thinking for MaRIE. We believe there is a bright future in cutting-edge experimental materials research, and that a 21st-century facility with unique capability is necessary to fulfill this goal. The Laboratory has spent the last several years defining MaRIE, and this issue of Vistas presents our current vision of that facility. MaRIE will leverage LANSCE and our other user facilities, as well as our internal and external materials community for decades to come, giving Los Alamos a unique competitive advantage, advancing materials science for the Laboratory's missions and attracting and recruiting scientists of international stature. MaRIE will give the international materials research community a suite of tools capable of meeting a broad range of outstanding grand challenges.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Application of a digital pileup resolving method to high count rate neutron measurements

The possibility of working in high count rate conditions is an important issue for neutron measurements applied to fusion experiments in order to extend the measurement dynamic range and time resolution. One of the main issues of high count rate operation is the overlapping of closely spaced events (pileup) that produces a distortion in their amplitude and therefore in the pulse height spectra. The usual way to deal with such pileup events using standard analog electronics is to reject them in the energy analysis process. Thanks to digital acquisition techniques, the waveforms of pileup events can be recorded and elaborated in order to reconstruct the contributing original single events. This work presents the results of the application of a pileup resolving method for the reconstruction and analysis of overlapping events to pulses acquired digitally from a NE213 liquid scintillator detector. The measurements have been carried out at the PTB accelerator facility with 14 MeV neutrons at total count rates over 400 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray imaging of subsurface dynamics in high-Z materials at the Diamond Light Source

In this paper, we describe a new approach enabling study of subsurface dynamics in high-Z materials using the unique combination of high-energy synchrotron X-rays, a hybrid bunch structure, and a new dynamic loading platform. We detail the design and operation of the purpose-built, portable small bore gas-gun, which was installed on the I12 high-energy beamline at the Diamond Light Source and used to drive compression waves into solid and porous metal targets. Using a hybrid bunch structure and broadband X-ray pulses of up to 300 keV, radiographic snapshots were captured during various dynamic deformation processes in cm-scale specimens, thereby contributing to a more complete understanding of the evolution of mesoscale damage. Importantly, we highlight strategies for overcoming the challenges associated with using high-energy X-rays, and suggest areas for improvement needed to advance dynamic imaging through large-scale samples of relevance to engineering scenarios. These preliminary measurements demonstrate the feasibility of probing highly transient phenomena using the presented methodology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic scintillators with high loading of one or more metal carboxylates

In one embodiment, a material includes at least one metal compound incorporated into a polymeric matrix, where the metal compound includes a metal and one or more carboxylate ligands, where at least one of the one or more carboxylate ligands includes a tertiary butyl group, and where the material is optically transparent. In another embodiment, a method includes: processing pulse traces corresponding to light pulses from a scintillator material; and outputting a result of the processing, where the scintillator material comprises at least one metal compound incorporated into a polymeric matrix, the at least one metal compound including a metal and one or more carboxylate ligands, where at least one of the one or more carboxylate ligands has a tertiary butyl group, and where the scintillator material is optically transparent and has an energy resolution at 662 keV of less than about 20%.

36 MATERIALS SCIENCE↗

Positron annihilation lifetime spectroscopy using fast scintillators and digital electronics

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron lifetime in a material sample under investigation. The positron trapping at vacancies in the material results in an increased positron lifetime. In this work, we have developed and optimized a PALS experimental setup using organic scintillators, fast digitizers, and advanced pulse processing algorithms. We tested three pairs of different organic scintillators: EJ-309 liquid, EJ-276 newly developed plastic, and BC- 418 plastic, and optimized the data processing parameters for each pair separately. Our high-throughput data analysis method is based on single-pulse interpolation and a constant fraction discrimination (CFD) algorithm. The setup based on the BC-418 detector achieved the best time resolution of 198.3 ± 0.8 ps. We used such optimized setup to analyze two single-crystal quartz samples and found lifetimes of 161 ± 4 ps, 343 ± 12 ps and 1.34 ± 0.05 ns, in good agreement with the characteristic time constants of this material. The proposed experimental set up achieves a time resolution comparable to the minimum positron lifetime in quartz, which makes it possible to accurately characterize material vacancies by discriminating between the lifetimes of either the spin singlet or triplet states of positronium. The optimized data processing algorithms are relevant to all the applications where fast timing is important, such as nuclear medicine and radiation imaging

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIF and OMEGA X-Ray Environments Summary

The National Ignition Facility (NIF) is a 192-beam laser system at Lawrence Livermore National Laboratory in California. The facility can deliver up to 1.8 MJ of ultraviolet energy to a target in shaped pulses that range from 1 – 20 ns in duration. The facility offers a 10 m diameter target chamber at high vacuum (10 -5 – 10 -4 torr) in which objects under test can be located. There are three diagnostic instrument manipulators (DIMs) that can be used for precise positioning of test objects or quick service and refurbishment of diagnostic systems. The facility plans to add two more DIMs by the end of calendar year 2016. The NIF currently pursues research into inertially confined fusion processes, high-energy-density science for the U.S. stockpile stewardship program, fundamental science research, and other national security applications such as radiation effects on materials, devices and systems, and weapons effects phenomena as well as issues relating to counter nuclear terrorism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Residual Stress Measurements in Extreme Environments for Hazardous, Layered Specimens

In nuclear fuel plates of low-enriched U-10Mo (LEU) clad with aluminum by hot isostatic pressing (HIP), post-irradiation stresses arising during reactor shutdown are a major concern for safe reactor operations. Measurement of those residual stresses has not previously been possible because the high radioactivity of the plates requires handling only by remote manipulation in a hot cell. The incremental slitting method for measuring through-thickness stress profiles was modified, and a system for automated, remote operation was built and tested. Experimental modifications consisted of replacing electric-discharge machining (EDM) with a small end mill and strain-gauge measurements with cantilever displacement measurements. The inverse method used to calculate stresses was the pulse-regularization method modified to allow discontinuities across material interfaces. The new system was validated by comparing with conventional slitting on a depleted U-10Mo (DU) fuel plate. The new system was applied to two measurements each on six as-fabricated (pre-irradiation) LEU miniature fuel plates. Variations between the measurements at two locations in the same plate were strongly correlated with measured geometrical heterogeneity in the plate—a tilt in the fuel foil. Compressive stresses in the U-10Mo were shown to increase from 20 to 250 MPa as the ratio of aluminum thickness to U-10Mo thickness increased causing increased constraint during cooling. Faster cooling rates during processing also increased stress magnitudes. The measurements trends agreed with data in the literature from similar plates made with DU, which further validates the method. Because other methods are impractical in a hot cell, the modified slitting method is now poised for the first measurements of post-irradiation stresses.

36 MATERIALS SCIENCE↗

Fibreoptic distributed temperature sensor with spectral filtration by directional fibre couplers

We demonstrate a Raman-based all-fibre temperature sensor utilising a pulsed erbium fibre laser. The sensor is made of a standard single-mode telecom fibre, SMF-28, and includes a number of directional couplers as band-pass filters. The temperature profile along a 7-km fibreoptic line is measured with an accuracy of 2{sup o}C and a spatial resolution of 10 m. In data processing, we take into account the difference in attenuation between the spectral components of the backscatter signal. (optical fibres and fibreoptic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microcontroller-based aerosol jet printer control software

This software is used with a microcontroller to control an aerosol jet printing system. It was written for a 32-bit ARM microcontroller, providing greater processing speed and complexity relative to more conventional low-cost printer controllers. The microcontroller software was written using a real-time operating system (FreeRTOS), which simplifies parallel operation of multiple functions and further customization. It supports simultaneous motion planning, pulse generation for stepper motors, reading encoder feedback, communicating with multiple mass flow controllers, controlling solid state relays, handling a software-based emergency stop, and sending data to the client PC. The program is written in C and communicates with the client PC via USB connection. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-0436 O

Secor, EthanBenjamin↗

Multiple-Input Data Acquisition System (MIDAS) for Measuring the Carbon Content in Soil Using Inelastic Neutron Scattering

This report describes work funder under STTR grants Phase I and II and carried out jointly by XIA LLC and Brookhaven National Laboratory (BNL). The project goal was to develop a mobile nuclear activation analysis instrument that could be towed behind a tractor to document soil carbon levels in agricultural lands for carbon credit certification. XIA developed large NaI(Tl) detectors with integrated digital pulse processors controlled over USB 2.0 and delivered 16 of these units to BNL for integration into the prototype instrument, together with the necessary software to calibrate them and collect data. For reasons that are unknown to XIA, the BNL participants never completed the prototype vehicle, performed system integration, or carried out the proposed qualification and field tests, leaving the project incomplete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser produced streams of Ge ions accelerated and optimized in the electric fields for implantation into SiO{sub 2} substrates

Ge crystals were prepared by means of laser-induced ion implantation technique. A Nd:YAG pulsed laser (repetition rate: 10 Hz; pulse duration: 3.5 ns; pulse energy: {approx}0.5 J) was used both as an ion source and to carry out the ablation processes. The optimization of the laser-generated ion beam parameters in a broad energy and current density range has been obtained controlling the electrostatic field parameters. Numerical simulations of the focusing system, performed adopting an OPERA 3D code, and an investigation of the ion characteristics, using the ion time-of-flight method, have allowed to optimize the preparation parameters. The structural properties of the samples were investigated by means of x-ray photoelectron, micro-Raman spectroscopies, and scanning electron microscopy techniques. Experimental results show that, by appropriately varying the ion implantation parameters and by a post-preparation annealing treatment, it is possible to achieve the development of a micrometer-sized crystalline Ge phase and/or an amorphous one.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Need for a New LLNL Pulsed Sphere Neutron Leakage Spectra Series

Here, it is shown that spectra measured as part of the Lawrence Livermore National Laboratory Pulsed Sphere (LPS) program offer decisive information to locate formatting or physics issues in nuclear data of key interest for fusion reactor simulations. However, experiments from this measurement series are not benchmarks. For instance, their uncertainties are incomplete. There are also many open questions—e.g., on the setup, the detector response, and whether LPS are accurately modeled—that cannot be answered anymore given the limited documentation and that many of the experimenters are no longer actively working. This limited knowledge has implications when one tries to adjust nuclear data to LPS spectra. Usually, one adjusts to benchmarks representing an application with the hope to get more precise nuclear data for the application of interest where differential data might be scarce and/or to reduce nuclear data uncertainties in the application simulations. However, it is demonstrated that adjustment with LPS spectra without accounting for missing uncertainties and modeling potential biases in the experimental data leads to adjusted data that are highly unphysical. That means adjusted data differ significantly from evaluated data based on information from differential experiments; also, application quantities predicted with the adjusted data deviate distinctly from experimental ones. While we can approximate our limited knowledge on these experiments with Gaussian processes in the adjustment process, this modeling of bias is arbitrary rather than based on a physics explanation, calling into doubt the validity of resulting adjusted data. Thus, we discuss here the need for a new measurement series, learning from the strengths and weaknesses of the LPS program, to yield decisive and well-benchmarked integral experiments to support fusion reactor research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗