Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Spectral and dynamical analysis of a single vortex ring in anisotropic harmonically trapped three-dimensional Bose-Einstein condensates

Here in the present work, motivated by numerous recent experimental developments we revisit the dynamics of a single vortex ring in anisotropic harmonic traps. At the theoretical level, we start from a general Lagrangian dynamically capturing the evolution of a vortex ring and not only consider its spectrum of linearized excitations, but also explore the full nonlinear dynamical evolution of the ring as a vortical filament. The theory predicts that the ring is stable for 1 ≤ λ ≤ 2, where λ = ω z /ω r is the ratio of the trapping frequencies along the z and r axes, i.e., for spherical to slightly oblate condensates. We compare this prediction with direct numerical simulations of the full three-dimensional Gross-Pitaevskii equation (GPE) capturing the linearization spectrum of the ring for different values of the chemical potential and as a function of the anisotropy parameter λ . We identify this result as being only asymptotically valid as the chemical potential μ → ∞, revealing how the stability interval narrows and, in particular, its upper bound decreases for finite μ. Finally, we compare at the dynamical level the results of the GPE with the ones effectively capturing the ring dynamics, revealing the unstable evolution for different values of λ, as well as the good agreement between the two.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mass Spectral Detection of Forward- and Reverse-Hydrogen/Deuterium Exchange Resulting from Residual Solvent Vapors in Electrospray Sources

Characterizing glycans is analytically challenging since glycans are heterogeneous, branched polymers with different three-dimensional conformations. Hydrogen/deuterium exchange-mass spectrometry (HDX-MS) has been used to analyze native conformations and dynamics of biomolecules by measuring the mass increase of analytes as labile protons are replaced with deuterium following exposure to deuterated solvents. The rate of exchange is dependent on the chemical functional group, the presence of hydrogen bonds, pH, temperature, charge, and solvent accessibility. HDX-MS of carbohydrates is challenging due to the rapid exchange rate of hydroxyls. Here, we describe an observed HDX reaction associated with residual solvent vapors saturating electrospray sources. When undeuterated melezitose was infused after infusing D{sub 2}O, samples with up to 73% deuterium exchange were detected. This residual solvent HDX was observed for both carbohydrates and peptides in multiple instruments and dependent on sample infusion rate, infusion time, and deuterium content of the solvent. This residual solvent HDX was observed over several minutes of sample analysis and persisted long enough to alter the measured deuterium labeling and possibly change the interpretation of the results. This work illustrates that residual solvent HDX competes with in-solution HDX for rapidly exchanging functional groups. Thus, we propose conditions to minimize this effect, specifically for top-down, in-electrospray ionization, and quench-flow HDX experiments. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UHECR ESCAPE MECHANISMS FOR PROTONS AND NEUTRONS FROM GAMMA-RAY BURSTS, AND THE COSMIC-RAY-NEUTRINO CONNECTION

The paradigm that gamma-ray burst fireballs are the sources of the ultra-high energy cosmic rays (UHECRs) is being probed by neutrino observations. Very stringent bounds can be obtained from the cosmic-ray (proton)-neutrino connection, assuming that the UHECRs escape as neutrons. In this study, we identify three different regimes as a function of the fireball parameters: the standard ''one neutrino per cosmic ray'' case, the optically thick (to neutron escape) case, and the case where leakage of protons from the boundaries of the shells (direct escape) dominates. In the optically thick regime, the photomeson production is very efficient, and more neutrinos will be emitted per cosmic ray than in the standard case, whereas in the direct escape-dominated regime, more cosmic rays than neutrinos will be emitted. We demonstrate that, for efficient proton acceleration, which is required to describe the observed UHECR spectrum, the standard case only applies to a very narrow region of the fireball parameter space. We illustrate with several observed examples that conclusions on the cosmic-ray-neutrino connection will depend on the actual burst parameters. We also show that the definition of the pion production efficiency currently used by the IceCube collaboration underestimates the neutrino production in the optically thick case. Finally, we point out that the direct escape component leads to a spectral break in the cosmic-ray spectrum emitted from a single source. The resulting ''two-component model'' can be used to even more strongly pronounce the spectral features of the observed UHECR spectrum than the dip model.

79 ASTRONOMY AND ASTROPHYSICS↗

Robotic reconnaissance platform. I. Spectroscopic instruments with rangefinders

In this paper, basic principles of the design and implementation of a portable, multi-functional scientific instrument, operating from a robotic reconnaissance mobile platform are discussed. The current version of the instrument includes a multi-gas laser sensor, multi-functional spectrometer, isotopes identifier, cameras, and rangefinder. An additional set of sensors monitors temperature, pressure, humidity, and background radiation. All components are installed on a mini-robotic platform, which provides data acquisition, processing, and transmittance. The design focuses on the development of calibration-free, reliable, low power-consumption devices. To create a highly survivable, accurate, and reliable instrument, a concept of an inhomogeneous sensory network has been developed. Such a network combines non-identical sensors and provides cross-use of information received from different sensors to describe environmental conditions, to choose appropriate algorithms of data processing, and to achieve high accuracy gas-concentration measurements. The system uses the same lasers to operate different optical devices such as sensors, rangefinders, spectrometers, and isotopes identifiers. Among the innovative elements described in this paper, are a calibration-free, laser multi-gas sensor with range-finding option; a high signal/noise ratio transmittance spectrometer; a single-frequency laser with nano-selector; and low repetition-rate femtosecond fiber lasers operating in near- and middle- infrared spectral ranges. New detailed analyses of absorption spectroscopy theoretical approximations made it possible to achieve high-accuracy gas-concentration measurements with miniature optical sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient thermal stress wave and vibrational analyses of a thin diamond crystal for X-ray free-electron lasers under high-repetition-rate operation

High-brightness X-ray free-electron lasers (FELs) are perceived as fourth-generation light sources providing unprecedented capabilities for frontier scientific researches in many fields. Thin crystals are important to generate coherent seeds in the self-seeding configuration, provide precise spectral measurements, and split X-ray FEL pulses, etc . In all of these applications a high-intensity X-ray FEL pulse impinges on the thin crystal and deposits a certain amount of heat load, potentially impairing the performance. In the present paper, transient thermal stress wave and vibrational analyses as well as transient thermal analysis are carried out to address the thermomechanical issues for thin diamond crystals, especially under high-repetition-rate operation of an X-ray FEL. The material properties at elevated temperatures are considered. It is shown that, for a typical FEL pulse depositing tens of microjoules energy over a spot of tens of micrometers in radius, the stress wave emission is completed on the tens of nanoseconds scale. The amount of kinetic energy converted from a FEL pulse can reach up to ~10 nJ depending on the layer thickness. Natural frequencies of a diamond plate are also computed. The potential vibrational amplitude is estimated as a function of frequency. Here, due to the decreasing heat conductivity with increasing temperature, a runaway temperature rise is predicted for high repetition rates where the temperature rises abruptly after ratcheting up to a point of trivial heat damping rate relative to heat deposition rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Packaging Certification program Methodology for Determining Dose Rates for Small Gram Quantities in Shipping Packagings

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials, under both normal and accident conditions, to perform the essential functions of material containment, subcriticality, and maintain external radiation levels within the specified limits. By placing the contents in a helium leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large dose rate outside the package. Quantifying the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings provides bounding shielding calculations that define mass limits compliant with 10 CFR 71.47 for a set of proposed SGQ isotopes. The approach is based on energy superposition with dose response calculated for a set of spectral groups for a baseline physical packaging configuration. The methodology includes using the MCNP radiation transport code to evaluate a family of neutron and photon spectral groups using the 9977 shipping package and its associated shielded containers as the base case. This results in a set of multipliers for 'dose per particle' for each spectral group. For a given isotope, the source spectrum is folded with the response for each group. The summed contribution from all isotopes determines the total dose from the RAM in the container.

42 ENGINEERING↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replica symmetry breaking for the integrable two-site Sachdev–Ye–Kitaev model

We analyze a two-body non-Hermitian two-site Sachdev–Ye–Kitaev (SYK) model with the couplings of one site complex conjugated to the other site. This model, with no explicit coupling between the sites, shows an infinite number of second-order phase transitions, which is a consequence of the factorization of the partition function into a product over Matsubara frequencies. We calculate the quenched free energy in two different ways: first in terms of the single-particle energies and second by solving the Schwinger–Dyson equations of the two-site model. The first calculation can be done entirely in terms of a one-site model. The conjugate replica enters due to non-analyticities when Matsubara frequencies enter the spectral support of the coupling matrix. The second calculation is based on the replica trick of the two-site partition function. Both methods give the same result. The free-fermion partition function can also be rephrased as a matrix model for the coupling matrix. Up to minor details, this model is the random matrix model that describes the chiral phase transition of QCD, and the order parameter of the two-body model corresponds to the chiral condensate of QCD. Comparing to the corresponding four-body model, we are able to determine which features of the free energy are due to the chaotic nature of the four-body model. The high-temperature phase of both models is entropy dominated, and in both cases, the free energy is determined by the spectral density. The chaotic four-body SYK model has a low-temperature phase whose free energy is almost temperature-independent, signaling an effective gap of the theory even though the actual spectrum does not exhibit a gap. On the other hand, the low-temperature free energy of the two-body SYK model is not flat; in fact, it oscillates to arbitrarily low temperature. This indicates a less desirable feature that the entropy of the two-body model is not always positive in the low-temperature phase, which most likely is a consequence of the non-hermiticity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvements to the three-color optical CCD-based pyrometer system

We put forward an improved three-color measurement scheme with a color CCD sensor using the combination of effective wavelengths and blackbody calibrations. The process of effective wavelengths realizes the separation of the emissivity function from the measurement integral equation. This improved method not only effectively avoids errors arising from the traditional process adopting the basic wavelengths, but also simplifies the complex integral calculations. For a blackbody or graybody, the measurement performance of the pyrometer was experimentally investigated from the point of the temperature sensitivity. The results show that narrowing the spectrum bandwidth with different bandpass spectral filters may improve the temperature sensitivities. The spectrum adjustment not only makes the linear emissivity more suitable in the narrower waveband, but also reduces the numerical uncertainty of the effective wavelengths. For nongray objects, the effects of the numerical uncertainty of the effective wavelengths to measurements were quantificationally evaluated at different measurement conditions (different temperatures, emissivities, and spectrums). The results indicate that the reference values of 584, 555, and 511nm or 607, 560, and 506nm of the effective wavelengths are reasonable for the present system with the modified spectral response using Filter 1 or Filter 2. The maximum calculation errors arising from the reference effective wavelengths are less than 1.6%. In this paper, the technical realization steps of the improved method are also described. The measurement experiments of a metal sample in hot environments were carried out to further verify the applicability of this improved CCD-based pyrometer. The results agreed well with the spectrometer-based results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A calibration of NICMOS Camera 2 for low count rates

NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z>1 SNe Ia. Unlike conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count rates. However, observations at faint count rates rely on extrapolations. Here instead, we provide a new zero-point calibration directly applicable to faint sources. This is obtained via inter-calibration of NIC2 F110W/F160W with the Wide Field Camera 3 (WFC3) in the low count-rate regime using z∼1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR spectral energy distributions, uniform colors, and their extended nature gives a superior signal-to-noise ratio at the same count rate than would stars. The use of extended objects also allows greater tolerances on point-spread function profiles. We find space telescope magnitude zero points (after the installation of the NICMOS cooling system, NCS) of 25.296 ±0.022 for F110W and 25.803 ±0.023 for F160W, both in agreement with the calibration extrapolated from count rates ≳1000 times larger (25.262 and 25.799). Before the installation of the NCS, we find 24.843 ±0.025 for F110W and 25.498 ±0.021 for F160W, also in agreement with the high-count-rate calibration (24.815 and 25.470). We also check the standard bandpasses of WFC3 and NICMOS 2 using a range of stars and galaxies at different colors and find mild tension for WFC3, limiting the accuracy of the zero points. To avoid human bias, our cross-calibration was “blinded” in that the fitted zero-point differences were hidden until the analysis was finalized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FRAM Version 6.1’s Bias

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. For FRAM version 4 and earlier, the reported uncertainties of the results come from the propagation of the statistics in the peak areas only. No systematic error components are included in the reported uncertainties. We did several studies with FRAM v.4 and found that FRAM’s statistical precision can be reasonably represented by its reported uncertainties. FRAM’s biases or systematic uncertainties can come from a variety of sources and can be difficult to determine. For FRAM version 5, we carefully examined the FRAM analytical results of both the archival plutonium data and the data specifically acquired for the isotopic uncertainty analysis project and found the relationship between the bias and other parameters. We then worked out the equations representing the biases of the measured isotopes from each measurement using internal spectral parameters, such as peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium). The resulting biases were included in the reported uncertainties of FRAM v.5. For the upcoming FRAM version 6.1, we are doing the same study that we did for FRAM v.5. The resulting biases will be included in its reported uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shape evolution in yttrium and niobium neutron-rich isotopes

The isotopic evolution of the ground-state nuclear shapes and the systematics of one-quasiproton configurations are studied in neutron-rich odd-A yttrium and niobium isotopes. We use a self-consistent Hartree-Fock-Bogoliubov formalism based on the Gogny energy density functional with two parametrizations, D1S and D1M. The equal-filling approximation is used to describe odd-A nuclei preserving both axial and time-reversal symmetries. Shape-transition signatures are identified in the N=60 isotopes in both the charge radii and spin parities of the ground states. These signatures are a common characteristic for nuclei in the whole mass region. The nuclear deformation and shape coexistence inherent to this mass region are shown to play a relevant role in the understanding of the spectroscopic features of the ground and low-lying one-quasiproton states. Finally, a global picture of the neutron-rich A{approx}100 mass region from krypton up to molybdenum isotopes is illustrated with the systematics of the nuclear charge radii isotopic shifts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiscale deformable registration for dual-energy x-ray imaging

Dual-energy (DE) imaging of the chest improves the conspicuity of subtle lung nodules through the removal of overlying anatomical noise. Recent work has shown double-shot DE imaging (i.e., successive acquisition of low- and high-energy projections) to provide detective quantum efficiency, spectral separation (and therefore contrast), and radiation dose superior to single-shot DE imaging configurations (e.g., with a CR cassette). However, the temporal separation between high-energy (HE) and low-energy (LE) image acquisition can result in motion artifacts in the DE images, reducing image quality and diminishing diagnostic performance. This has motivated the development of a deformable registration technique that aligns the HE image onto the LE image before DE decomposition. The algorithm reported here operates in multiple passes at progressively smaller scales and increasing resolution. The first pass addresses large-scale motion by means of mutual information optimization, while successive passes (2-4) correct misregistration at finer scales by means of normalized cross correlation. Evaluation of registration performance in 129 patients imaged using an experimental DE imaging prototype demonstrated a statistically significant improvement in image alignment. Specific to the cardiac region, the registration algorithm was found to outperform a simple cardiac-gating system designed to trigger both HE and LE exposures during diastole. Modulation transfer function (MTF) analysis reveals additional advantages in DE image quality in terms of noise reduction and edge enhancement. This algorithm could offer an important tool in enhancing DE image quality and potentially improving diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photosphere emission in the X-ray flares of swift gamma-ray bursts and implications for the fireball properties

X-ray flares of gamma-ray bursts (GRBs) are usually observed in the soft X-ray range and the spectral coverage is limited. In this paper, we present an analysis of 32 GRB X-ray flares that are simultaneously observed by both Burst Alert Telescope and X-Ray Telescope on board the Swift mission, so that a joint spectral analysis with a wider spectral coverage is possible. Our results show that the joint spectra of 19 flares are fitted with the absorbed single power law or the Band function models. More interestingly, the joint spectra of the other 13 X-ray flares are fitted with the absorbed single power-law model plus a blackbody component. Phenomenally, the observed spectra of these 13 flares are analogous to several GRBs with a thermal component, but only with a much lower temperature of kT = 1 ∼ 3 keV. Assuming that the thermal emission is the photosphere emission of the GRB fireball, we derive the fireball properties of the 13 flares that have redshift measurements, such as the bulk Lorentz factor Γ{sub ph} of the outflow. The derived Γ{sub ph} range from 50 to 150 and a relation of Γ{sub ph} to the thermal emission luminosity is found. It is consistent with the Γ{sub 0} – L {sub iso} relations that are derived for the prompt gamma-ray emission. We discuss the physical implications of these results within the content of jet composition and the radiation mechanism of GRBs and X-ray flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Detector Response Function and Directional Gamma-Ray Source Calculations for Polaris

A Directional Unfolded Source Term (DUST) method was developed to compute directionally resolved gamma-ray source terms based on back-projection spectra synthesized by Compton Cameras. Spectral features in the unprocessed spectra are indistinct primarily because the rotational angles for the conical projections cannot be determined, so probability distributions are constructed from overlapping cones. The DUST method uses an angular response function to compute a covariance matrix, which is used to process count rates in back-projection spectra by linear regression to partition the gamma-rays among several spatial regions. This method was applied to analyze data collected by the Polaris detector during an evaluation that was conducted at Oak Ridge National Laboratory (ORNL). The evaluation includes measurements of calibration sources with angular separations ranging from 1° to more than 50°. Measurements were also performed for cylindrical depleted uranium castings and a 137 Cs source inside a large polyethylene sphere. The DUST algorithm was able to differentiate gamma-rays emitted by 137 Cs and 60 Co when the sources were separated by less than 2°, but separation greater than 10° was required to isolate the 133 Ba emission from gamma-rays emitted by the other sources. The computed source terms were consistent with emission profiles from the calibration sources and from models of the spatially-extended sources. Methods for viewing radiation profiles were also evaluated because user input is required to select spatial regions of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗