Search NASA⌕ Search

SEARCH · Search NASA

Results for “orientation distribution function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Temperature-dependent photon scattering in blue-detuned optical traps

We have observed time-varying spin relaxation of trapped cold atoms due to photon scattering in blue-detuned, crossed, hollow Laguerre-Gaussian beams. These beams are formed by imparting an azimuthal phase of l{phi} to a Gaussian beam, where l is an integer, and have an intensity distribution that scales with r{sup 2l} to the lowest order. For all degrees of anharmonicity, we observe a time-varying spin-relaxation rate due to energy-dependent photon scattering. For l=8, we directly measure temperature-dependent scattering rates and show that by removing the most energetic atoms from the trap, a more purely spin-polarized sample remains. The results agree well with Monte Carlo simulations, and we present a simple functional form for the spin-relaxation curves.

74 ATOMIC AND MOLECULAR PHYSICS↗

Supporting 64-bit global indices in Epetra and other Trilinos packages :

The Trilinos Project is an effort to facilitate the design, development, integration and ongoing support of mathematical software libraries within an object-oriented framework. It is intended for large-scale, complex multiphysics engineering and scientific applications [2, 4, 3]. Epetra is one of its basic packages. It provides serial and parallel linear algebra capabilities. Before Trilinos version 11.0, released in 2012, Epetra used the C++ int data-type for storing global and local indices for degrees of freedom (DOFs). Since int is typically 32-bit, this limited the largest problem size to be smaller than approximately two billion DOFs. This was true even if a distributed memory machine could handle larger problems. We have added optional support for C++ long long data-type, which is at least 64-bit wide, for global indices. To save memory, maintain the speed of memory-bound operations, and reduce further changes to the code, the local indices are still 32-bit. We document the changes required to achieve this feature and how the new functionality can be used. We also report on the lessons learned in modifying a mature and popular package from various perspectives design goals, backward compatibility, engineering decisions, C++ language features, effects on existing users and other packages, and build integration.

Jhurani, Chetan↗

Chitosan Molecular Structure as a Function of N-Acetylation

Molecular dynamics simulations have been carried out to characterize the structure and solubility of chitosan nanoparticle-like structures as a function of the deacetylation level (0, 40, 60, and 100%) and the spatial distribution of the N-acetyl groups in the particles. The polysaccharide chains of highly N-deacetylated particles where the N-acetyl groups are uniformly distributed present a high flexibility and preference for the relaxed two-fold helix and five-fold helix motifs. When these groups are confined to a given region of the particle, the chains adopt preferentially a two-fold helix with f and w values close to crystalline chitin. Nanoparticles with up to 40% acetylation are moderately soluble, forming stable aggregates when the N-acetyl groups are unevenly distributed. Systems with 60% or higher N-acetylation levels are insoluble and present similar degrees of swelling regardless the distribution of their N-acetyl groups. Overall particle solvation is highly affected by electrostatic forces resulting from the degree of acetylation. The water mobility and orientation around the polysaccharide chains affects the stability of the intramolecular O3- HO3(n) ... O5(n+ 1) hydrogen bond, which in turn controls particle aggregation.

08 HYDROGEN↗

SEGUID v2: Extending SEGUID checksums for circular, linear, single- and double-stranded biological sequences

Background Synthetic biology involves combining different DNA fragments, each containing functional biological parts, to address specific problems. Fundamental gene-function research often requires cloning and propagating DNA fragments, such as those from the iGEM Parts Registry or Addgene, typically distributed as circular plasmids. Addgene’s repository alone offers around 150,000 plasmids. To ensure data integrity, cryptographic checksums can be calculated for the sequences. Each sequence has a unique checksum, making checksums useful for validation and quick lookups of associated annotations. For example, the SEGUID checksum uniquely identifies protein sequences with a 27-character string. Objectives The original SEGUID, while effective for protein sequences and single-stranded DNA (ssDNA), is not suitable for circular DNA since there is no natural starting position nor for double-stranded DNA (dsDNA) since two separate sequences are present. Challenges include how to uniquely represent linear dsDNA, circular ssDNA, and circular dsDNA. To meet these needs, we propose SEGUID v2, which extends the original SEGUID to handle additional types of sequences. Conclusions SEGUID v2 produces orientation and rotation invariant checksums for single-stranded, double-stranded, possibly staggered, linear, and circular DNA and RNA sequences. Customizable alphabets allow for other types of sequences. In contrast to the original SEGUID, which uses Base64, SEGUID v2 uses Base64url to encode the SHA-1 hash. This ensures SEGUID v2 checksums can be used as-is in filenames, regardless of platform, and in URLs, with minimal friction. Availability SEGUID v2 is readily available for major programming languages, distributed under the MIT license. JavaScript package seguid is available on npm, Python package seguid on PyPi, R package seguid on CRAN, and a Tcl script on GitHub. These tools, along with documentation, examples, and an online SEGUID Calculator , can be found at https://www.seguid.org .

Pereira, Humberto↗

A simple geometric algorithm to predict optimal starting gantry angles using equiangular-spaced beams for intensity modulated radiation therapy of prostate cancer

A fast, geometric beam angle optimization (BAO) algorithm for clinical intensity-modulated radiation therapy (IMRT) was implemented on ten localized prostate cancer patients on the Radiation Therapy Oncology Group (RTOG) 0126 protocol. The BAO algorithm computed the beam intersection volume (BIV) within the rectum and bladder using five and seven equiangular-spaced beams as a function of starting gantry angle for comparison to the V 75 Gy and V 70 Gy. A mathematical theory was presented to explain the correlation of BIV with dose and dose-volume metrics. The class solution 'W' pattern in the rectal V 75 Gy and V 70 Gy as a function of starting gantry angle using five equiangular-spaced beams (with two separate minima centered near 20 deg. and 50 deg. ) was reproduced by the 5 BIV within the rectum. A strong correlation was found between the rectal 5 BIV and the rectal V 75 Gy and V 70 Gy as a function of starting gantry angle. The BAO algorithm predicted the location of the two dosimetric minima in rectal V 75 Gy and V 70 Gy (optimal starting gantry angles) to within 5 deg. . It was demonstrated that the BIV geometric variations for seven equiangular-spaced beams were too small to translate into a strong dosimetric effect in the rectal V 75 Gy and V 70 Gy. The relatively flat distribution with starting gantry angle of the bladder V 75 Gy and V 70 Gy was reproduced by the bladder five and seven BIV for each patient. A geometric BAO method based on BIV has the advantage over dosimetric BAO methods of simplicity and rapid computation time. This algorithm can be used as a standalone optimization method or act as a rapid calculation filter to reduce the search space for a dosimetric BAO method. Given the clinically infeasible computation times of many dosimetric beam orientation optimization algorithms, this robust geometric BIV algorithm has the potential to facilitate beam angle selection for prostate IMRT in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

Peeling back the layers: Investigating the effects of polyelectrolyte layering on surface structure and stability of oil-in-water nanoemulsions

Layer-by-layer deposition of polyelectrolytes is a useful technique for modifying surface functionalities. For drug delivery systems, alternating layers of biopolymers coat nanoemulsions, which house and protect the cargo until the time and destination of delivery. In this report we investigate molecular factors contributing to the stability and interfacial properties of nanoemulsions prepared by a co-adsorption of polymers poly(styrene sulfonate) and polyethylenimine (PEI), and surfactant dodecyltrimethylammonium bromide. We hypothesize the interplay between electrosteric and hydrophobic effects upon multi-polymer co-adsorption contributes to both macroscopic and molecular-level interfacial properties of nanoemulsions. To probe interfacial layering properties, we use vibrational sum frequency scattering spectroscopy with ζ -potential measurements to determine the adsorptive behavior and molecular conformational arrangement of the polymer layers. Complementing these interfacial studies are dynamic light scattering experiments measuring the nanoemulsion size distribution and polydispersity index over a 30-day period. Our light scattering, ζ -potential, and spectroscopic results of the nanoemulsion surface show that the duration of droplet stability and the degree of molecular orientation of adsorbed polymers can be tuned by surfactant concentration, PEI concentration, and pH. These results illustrate how molecular surface properties of multi-polymer coated nanoemulsions contribute to synergistic effects and droplet stability, enabling advancements in applications surrounding biopharmaceuticals, cosmetics, and food sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosion-resistant polyurethane coatings from structure-homogenized biorefinery lignin through fractionation and oxypropylation

Using lignin for polyurethane (PU) synthesis is challenging because of its heterogeneous structure, i.e., broad molecule weight (MW) distribution and diverse hydroxyl (OH) functionality. This complexity influences the crosslinking reaction between lignin and isocyanate and affects the quality of PU products. Here, we propose a two-step strategy for lignin structure homogenization by lowering its MW and uniforming OH functionality (step 2). Step 1 involves a bioethanol fractionation process, yielding fractionated lignin with one order lower MW than the raw lignin while exhibiting better processability for the subsequent process. Step 2 is performed by an oxyalkylation process using fractionated lignin that converts phenolic and carboxylic OHs to aliphatic OHs. As a result, we obtained structure-homogenized lignin with good compatibility and crosslinking with hexamethylene diisocyanate for PU coating synthesis. Moreover, PU coatings prepared from structure-homogenized lignin display a defect-free microscopic structure and show better corrosion resistance than coatings fabricated from its raw lignin alternative. Overall, the structure homogenization process is a beneficial way of using lignin as biopolyol in PU synthesis toward the application-oriented design of corrosion-resistant lignin-based PU coatings.

36 MATERIALS SCIENCE↗

Development of Lightweight Structural Materials with Improved Properties for Fission Batteries

The notion of a “fission battery” conveys a vision focused on realizing very simple “plug-and-play” nuclear systems that can be integrated into a variety of applications requiring affordable, reliable energy in the form of electricity and/or heat and function without operations and maintenance staff. Fission batteries require lightweight structural materials to increase their mobility, and the lightweight materials must demonstrate structural resilience under various conditions. The objective of this work is to develop lightweight structural material featuring a good combination of mechanical properties using advanced modeling and simulation together with an advanced additive manufacturing technique such as laser powder bed fusion. The preliminary results show that different lattice structures and types can be successfully meshed using nTopology software, and the lattice structure data can be successfully transformed to Multiphysics Object-Oriented Simulation Environment (MOOSE) input. Finite Element Analysis (FEA) displays that, at macro/engineering scale simulation, the weight saving design has an obvious effect on tensile behavior such as effective elastic modulus and yield stress. The novel approaches of this work are (1) development of optimized lattice structures for improved mechanical properties using advanced simulation and modeling techniques; and (2) model predictions of the mechanical properties (e.g., strength and stress distribution) of macroscopic materials in order to preliminarily select a lattice structure for additive manufacturing.

36 MATERIALS SCIENCE↗

Reaction Kinetics of Water Molecules with Oxygen Vacancies on Rutile TiO 2 (110)

The formation of bridging hydroxyls (OHb) via reactions of water molecules with oxygen vacancies (VO) on reduced TiO 2 (110) surfaces is studied using infrared reflection-absorption spectroscopy (IRAS), electron-stimulated desorption (ESD), and photon-stimulated desorption (PSD). Narrow IRAS peaks at 2737 cm-1 and 3711 cm -1 are observed for stretching vibrations of OD b and OH b on TiO 2 (110), respectively. IRAS measurements with s- and p-polarized light demonstrate that the bridging hydroxyls are oriented normal to the (110) surface. The IR peaks disappear after the sample is exposed to O 2 or annealed in the temperature range of 400 – 600 K (correlating with the temperature at which pairs of OHb’s reform water and then desorb), which is consistent with their identification as bridging hydroxyls. We have studied the kinetics of water reacting with the vacancies by monitoring the formation of bridging hydroxyls (using IRAS) as a function of the annealing temperature for a small amount of water initially dosed on the TiO 2 (110) at low temperature. Separate experiments have also monitored the loss of water molecules (using water ESD) and vacancies (using the CO photooxidation reaction) due to the reactions of water molecules with the vacancies. All three techniques show that the reaction rate becomes appreciable for T > 150 K and that the reactions largely complete for T > 250 K. The temperature-dependent water-VO reaction kinetics are consistent with a Gaussian distribution of activation energies with E a = 0.545 eV, ΔE a (FWHM) = 0.125 eV, and a “normal” prefactor, v = 10 12 s -1 . In contrast, a single activation energy with a physically reasonable prefactor does not fit the data well. Our experimental activation energy is close to theoretical estimates for the diffusion of water molecules along the Ti 5c rows on the reduced TiO 2 (110) surface, which suggests that the diffusion of water controls the water – V O reaction rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of Lightweight Structural Materials with Improved Properties for Fission Batteries

The notion of a “fission battery” conveys a vision focused on realizing very simple “plug-and-play” nuclear systems that can be integrated into a variety of applications requiring affordable, reliable energy in the form of electricity and/or heat and function without operations and maintenance staff. Fission batteries require lightweight structural materials to increase their mobility, and the lightweight materials must demonstrate structural resilience under various conditions. The objective of this work is to develop lattice structured lightweight structural material featuring a good combination of mechanical properties using advanced modeling and simulation together with an advanced additive manufacturing technique such as laser powder bed fusion. The preliminary results show that different lattice structures and types can be successfully meshed using nTopology software, and the lattice structure data can be successfully transformed to Multiphysics Object-Oriented Simulation (MOOSE) Environment input. Finite Element Analysis (FEA) displays that, at macro/engineering scale simulation, the weight saving design has an obvious effect on tensile behavior such as effective elastic modulus and yield stress. The novel approaches of this work are (1) development of lattice structures for improved mechanical properties using advanced simulation and modeling techniques; and (2) model predictions of the mechanical properties (e.g., strength and stress distribution) of macroscopic materials in order to preliminarily select a lattice structure for additive manufacturing.

36 MATERIALS SCIENCE↗

COMPUTER-AIDED LATTICE DESIGN AND ADVANCED MODELING FOR THE DEVELOPMENT OF LIGHTWEIGHT STRUCTURAL MATERIALS

The notion of a “fission battery” conveys a vision focused on realizing very simple “plug-and-play” nuclear systems that can be integrated into a variety of applications requiring affordable, reliable energy in the form of electricity and/or heat and function without operations and maintenance staff. Fission batteries require lightweight structural materials to increase their mobility, and the lightweight materials must demonstrate structural resilience under various conditions. The objective of this work is to develop lattice structured lightweight structural material featuring a good combination of mechanical properties using advanced modeling and simulation together with an advanced additive manufacturing technique such as laser powder bed fusion. The preliminary results show that different lattice structures and types can be successfully meshed using nTopology software, and the lattice structure data can be successfully transformed to Multiphysics Object-Oriented Simulation (MOOSE) Environment input. Finite Element Analysis (FEA) displays that, at macro/engineering scale simulation, the weight saving design has an obvious effect on tensile behavior such as effective elastic modulus and yield stress. The novel approaches of this work are (1) development of lattice structures for improved mechanical properties using advanced simulation and modeling techniques; and (2) model predictions of the mechanical properties (e.g., strength and stress distribution) of macroscopic materials in order to preliminarily select a lattice structure for additive manufacturing.

36 MATERIALS SCIENCE↗

On the ultimate tensile strength of tantalum

Strain rate, temperature, and microstructure play a significant role in the mechanical response of materials. By using non-equilibrium molecular dynamics simulations, we characterize the ductile tensile failure of a model body-centered cubic metal, tantalum, over six orders of magnitude in strain rate. Molecular dynamics calculations combined with reported experimental measurements show power-law kinetic relationships that vary as a function of dominant defect mechanism and grain size. The maximum sustained tensile stress, or spall strength, increases with increasing strain rate, before ultimately saturating at ultra-high strain rates, i.e. those approaching or exceeding the Debye frequency. The upper limit of tensile strength can be well estimated by the cohesive energy, or the energy required to separate atoms from one another. At strain rates below the Debye frequency, the spall strength of nanocrystalline Ta is less than single crystalline tantalum. This occurs in part due to the decreased flow stress of the grain boundaries; stress concentrations at grain boundaries that arise due to compatibility requirements; and the growing fraction of grain-boundary atoms as grain size is decreased into the nanocrystalline regime. In the present cases, voids nucleate at defect structures present in the microstructure. The exact makeup and distribution of defects is controlled by the initial microstructure and the plastic deformation during both compression and expansion, where grain boundaries and grain orientation play critical roles.

36 MATERIALS SCIENCE↗