Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study

Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics robotics stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning patients to isocenter with high 6DOF accuracy.

60 APPLIED LIFE SCIENCES↗

Poster - 44: Development and implementation of a comprehensive end-to-end testing methodology for linac-based frameless SRS QA using a modified commercial stereotactic anthropomorphic phantom

Purpose: An end-to-end testing methodology was designed to evaluate the overall SRS treatment fidelity, incorporating all steps in the linac-based frameless radiosurgery treatment delivery process. The study details our commissioning experience of the Steev (CIRS, Norfolk, VA) stereotactic anthropomorphic head phantom including modification, test design, and baseline measurements. Methods: Repeated MR and CT scans were performed with interchanging inserts. MR-CT fusion accuracy was evaluated and the insert spatial coincidence was verified on CT. Five non-coplanar arcs delivered a prescription dose to a 15 mm spherical CTV with 2 mm PTV margin. Following setup, CBCT-based shifts were applied as per protocol. Sequential measurements were performed by interchanging inserts without disturbing the setup. Spatial and dosimetric accuracy was assessed by a combination of CBCT hidden target, radiochromic film, and ion chamber measurements. To facilitate film registration, the film insert was modified in-house by etching marks. Results: MR fusion error and insert spatial coincidences were within 0.3 mm. Both CBCT and film measurements showed spatial displacements of 1.0 mm in similar directions. Both coronal and sagittal films reported 2.3 % higher target dose relative to the treatment plan. The corrected ion chamber measurement was similarly greater by 1.0 %. The 3 %/2 mm gamma pass rate was 99% for both films Conclusions: A comprehensive end-to-end testing methodology was implemented for our SRS QA program. The Steev phantom enabled realistic evaluation of the entire treatment process. Overall spatial and dosimetric accuracy of the delivery were 1 mm and 3 % respectively.

60 APPLIED LIFE SCIENCES↗

Relaxation measurements of an MRI system phantom at low magnetic field strengths

Abstract Objective Temperature controlled T 1 and T 2 relaxation times are measured on NiCl 2 and MnCl 2 solutions from the ISMRM/NIST system phantom at low magnetic field strengths of 6.5 mT, 64 mT and 550 mT. Materials and methods The T 1 and T 2 were measured of five samples with increasing concentrations of NiCl 2 and five samples with increasing concentrations of MnCl 2 . All samples were scanned at 6.5 mT, 64 mT and 550 mT, at sample temperatures ranging from 10 °C to 37 °C. Results The NiCl 2 solutions showed little change in T 1 and T 2 with magnetic field strength, and both relaxation times decreased with increasing temperature. The MnCl 2 solutions showed an increase in T 1 and a decrease in T 2 with increasing magnetic field strength, and both T 1 and T 2 increased with increasing temperature. Discussion The low field relaxation rates of the NiCl 2 and MnCl 2 arrays in the ISMRM/NIST system phantom are investigated and compared to results from clinical field strengths of 1.5 T and 3.0 T. The measurements can be used as a benchmark for MRI system functionality and stability, especially when MRI systems are taken out of the radiology suite or laboratory and into less traditional environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crossing the phantom divide line in a Dvali-Gabadadze-Porrati-inspired F(R,{phi}) gravity

We study possible crossing of the phantom divide line in a Dvali-Gabadadze-Porrati-inspired F(R,{phi}) braneworld scenario where the scalar field and curvature quintessence are treated in a unified framework. With a specific form of F(R,{phi}) and by adopting a suitable ansatz, we show that there are appropriate regions of the parameter space which account for late-time acceleration and admit crossing of the phantom divide line.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase-space analysis of interacting phantom cosmology

We perform a detailed phase-space analysis of various phantom cosmological models, where the dark energy sector interacts with the dark matter one. We examine whether there exist late-time scaling attractors, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. We find that all the examined models, although accepting stable late-time accelerated solutions, cannot alleviate the coincidence problem, unless one imposes a form of fine-tuning in the model parameters. It seems that interacting phantom cosmology cannot fulfill the basic requirement that led to its construction.

79 ASTRONOMY AND ASTROPHYSICS↗

Trabecula: A Random Generator of Computational Phantoms for Bone Marrow Dosimetry

This study was motivated by the efforts on evaluation of radiation risk for leukemia incidence in the Techa River Cohort, where the main bone marrow dose contributors were 89,90Sr (bone-seeking beta emitters). Energy deposition in bone marrow targets was evaluated by simulating radiation particle transport using computational phantoms. The present paper describes the computer program “Trabecula” implementing an algorithm for parametric generation of computational phantoms, which serve as the basis for calculating bone marrow doses. “Trabecula” is a user-friendly tool that automatically converts analytical models into voxelized representations that are directly compatible as input to MCNP.

Shishkina, Elena A.↗

Quantum fields near phantom-energy ''sudden'' singularities

This paper is committed to calculations near a type of future singularity driven by phantom energy. At the singularities considered, the scale factor remains finite but its derivative diverges. The general behavior of barotropic phantom energy producing this singularity is calculated under the assumption that near the singularity such fluid is the dominant contributor. We use the semiclassical formula for renormalized stress tensors of conformally invariant fields in conformally flat spacetimes and analyze the softening/enhancing of the singularity due to quantum vacuum contributions. This dynamical analysis is then compared to results from thermodynamical considerations. In both cases, the vacuum states of quantized scalar and spinor fields strengthen the accelerating expansion near the singularity whereas the vacuum states of vector fields weaken it.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Noether symmetry approach in phantom quintessence cosmology

In the framework of phantom quintessence cosmology, we use the Noether Symmetry Approach to obtain general exact solutions for the cosmological equations. This result is achieved by the quintessential (phantom) potential determined by the existence of the symmetry itself. A comparison between the theoretical model and observations is worked out. In particular, we use type Ia supernovae and large-scale structure parameters determined from the 2-degree Field Galaxy Redshift Survey and from the Wide part of the VIMOS-VLT Deep Survey. It turns out that the model is compatible with the presently available observational data. Moreover we extend the approach to include radiation. We show that it is compatible with data derived from recombination and it seems that quintessence do not affect nucleosynthesis results.

99 GENERAL AND MISCELLANEOUS↗

Temporal light modulation: A phantom array visibility measure

At temporal light modulation (TLM) frequencies between 80 Hz and 20 000 Hz observers may perceive a series of repeated images called the phantom array effect (PAE) when they move their eyes in large saccades across a modulating light source or across a scene lit by the modulating light source. To date, there is no well-established measure for quantifying PAE visibility, but there is growing awareness of the need for one among design professionals and sensitive populations. This paper documents a new measure, the phantom array visibility measure (PAVM), which is based on the results of recent human factors experiments. The measure follows the mathematical underpinning used by the flicker visibility measure and the stroboscopic visibility measure, where the time-domain TLM waveform is converted into its Fourier frequency components; each component is evaluated through a threshold curve of modulation depth, then summed through an equation employing a Minkowski exponent. This scales the PAVM so that a value of 1 indicates a waveform at a threshold visibility in the conditions of the underlying experiment.

Tan, J.↗

UAS remote sensing (DJI Phantom 4 RTK platform): RGB orthomosaic, digital surface and canopy height models, plant functional type map, Seward Peninsula, Alaska, 2019

Airborne remote sensing data collected using a DJI Phantom 4 RTK unoccupied aerial system (UAS) ? operated by the University of Maine Wheatland Geospatial Lab (https://wheatlandlab.org/). This package includes data from 17 flights flown over the NGEE-Arctic Council, Kougarok, Kougarok Mile80, Teller, and Teller Mile32 sites in July 2019. The Phantom 4 RTK is a drone platform that collects very high spatial resolution optical red/green/blue (RGB) imagery. Derived image products include point cloud, ortho-mosaiced RGB, a digital surface model (DSM) using the structure from motion (SfM) technique, and a canopy height model (CHM). Unprocessed and processed data products (1,000+ files) are included in this package (processing levels 0-3). Data and metadata are provided as text (*.txt, *.json, *hdr,), ENVI image file (*.dat), point cloud (*.laz) and image (*.jpg, *.tif, *png) formats. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Hot streaks and phantom cooling in a turbine rotor passage. I - Separate effects

Experimental documentation and analytical correlations demonstrating the effects of hot streak accumulation and phantom cooling on turbine rotor airfoil surface temperature. Test results are shown for a range of controlling variables to identify where streak accumulation and phantom cooling are most likely to be strongest. These variables include streak injection location, streak-to-free stream density ratio and coolant-to-free stream density and velocity ratios.

Roback, Richard J.↗

Hot streaks and phantom cooling in a turbine rotor passage. II - Combined effects and analytical modelling

Experimental documentation and analytical correlations demonstrating the effects of hot streak accumulation and phantom cooling on turbine rotor airfoil surface temperature are presented. Results are shown which quantify the impact of a nonuniform temperature profile at the entrance of a turbine due to combustor-generated hot and cold streaks, and cooling air discharged from the trailing edge of the upstream stator. Experimental results are shown for a range of controlling variables to identify where streak accumulation and phantom cooling were most likely to be strongest. These variables include streak-to-free stream density ratio, streak injection location, and coolant-to-free stream density and velocity ratios. Experimental results are shown for the combined effects of hot streak and stator coolant on the adiabatic recovery temperature of the rotor.

Roback, Richard J.↗

MCNPX Cosmic Ray Shielding Calculations with the NORMAN Phantom Model

The United States is planning manned lunar and interplanetary missions in the coming years. Shielding from cosmic rays is a critical aspect of manned spaceflight. These ventures will present exposure issues involving the interplanetary Galactic Cosmic Ray (GCR) environment. GCRs are comprised primarily of protons (approx.84.5%) and alpha-particles (approx.14.7%), while the remainder is comprised of massive, highly energetic nuclei. The National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) has commissioned a joint study with Los Alamos National Laboratory (LANL) to investigate the interaction of the GCR environment with humans using high-fidelity, state-of-the-art computer simulations. The simulations involve shielding and dose calculations in order to assess radiation effects in various organs. The simulations are being conducted using high-resolution voxel-phantom models and the MCNPX[1] Monte Carlo radiation-transport code. Recent advances in MCNPX physics packages now enable simulated transport over 2200 types of ions of widely varying energies in large, intricate geometries. We report here initial results obtained using a GCR spectrum and a NORMAN[3] phantom.

James, Michael R.↗

[Micron]ADS-B Detect and Avoid Flight Tests on Phantom 4 Unmanned Aircraft System

Researchers at the National Aeronautics and Space Administration Armstrong Flight Research Center in Edwards, California and Vigilant Aerospace Systems collaborated for the flight-test demonstration of an Automatic Dependent Surveillance-Broadcast based collision avoidance technology on a small unmanned aircraft system equipped with the uAvionix Automatic Dependent Surveillance-Broadcast transponder. The purpose of the testing was to demonstrate that National Aeronautics and Space Administration / Vigilant software and algorithms, commercialized as the FlightHorizon UAS"TM", are compatible with uAvionix hardware systems and the DJI Phantom 4 small unmanned aircraft system. The testing and demonstrations were necessary for both parties to further develop and certify the technology in three key areas: flights beyond visual line of sight, collision avoidance, and autonomous operations. The National Aeronautics and Space Administration and Vigilant Aerospace Systems have developed and successfully flight-tested an Automatic Dependent Surveillance-Broadcast Detect and Avoid system on the Phantom 4 small unmanned aircraft system. The Automatic Dependent Surveillance-Broadcast Detect and Avoid system architecture is especially suited for small unmanned aircraft systems because it integrates: 1) miniaturized Automatic Dependent Surveillance-Broadcast hardware; 2) radio data-link communications; 3) software algorithms for real-time Automatic Dependent Surveillance-Broadcast data integration, conflict detection, and alerting; and 4) a synthetic vision display using a fully-integrated National Aeronautics and Space Administration geobrowser for three dimensional graphical representations for ownship and air traffic situational awareness. The flight-test objectives were to evaluate the performance of Automatic Dependent Surveillance-Broadcast Detect and Avoid collision avoidance technology as installed on two small unmanned aircraft systems. In December 2016, four flight tests were conducted at Edwards Air Force Base. Researchers in the ground control station looking at displays were able to verify the Automatic Dependent Surveillance-Broadcast target detection and collision avoidance resolutions.

avoidance↗

Robotically Assisted CBCT-Guided Needle Insertions: Preliminary Results in a Phantom Model

Aim: To compare robotic-assisted needle insertions performed under CBCT guidance to standard manual needle insertions. Materials and Methods: A homemade robotic prototype was used by two operators to perform robotic and manual needle insertions on a custom-made phantom. Both the operators had no experience with the prototype before starting the trial. The primary endpoint was accuracy (i.e., the minimal distance between the needle tip and the center of the target) between robotic and manual insertions. Secondary endpoints included total procedure time and operators’ radiation exposure. The Wilcoxon test was used. A p value less than 0.05 was considered statistically significant. Results: Thirty-three (17 manual, 16 robotic) needle insertions were performed. Mean accuracy for robotic insertion was 2.3 ± 0.9 mm (median 2.1; range 0.8–4.2) versus 2.3 ± 1 mm (median 2.1; range 0.7–4.4) for manual insertion (p = 0.84). Mean procedure time was 683 ± 57 s (median 670; range 611–849) for the robotic group versus 552 ± 40 s (median 548; range 486–621) for the manual group (p = 0.0002). Mean radiation exposure was 3.25 times less for the robotic insertion on comparison to manual insertion for the operator 1 (0.4 vs 1.3 µGy); and 4.15 times less for the operator 2 (1.9 vs 7.9 µGy). Conclusion: The tested robotic prototype showed accuracy comparable to that achieved with manual punctures coupled to a significant reduction of operators’ radiation exposure. Further, in vivo studies are necessary to confirm the efficiency of the system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of small-field tissue phantom ratio data generation methods for an Elekta Agility 6 MV photon beam

Tissue-phantom ratios (TPRs) are a common dosimetric quantity used to describe the change in dose with depth in tissue. These can be challenging and time consuming to measure. The conversion of percentage depth dose (PDD) data using standard formulae is widely employed as an alternative method in generating TPR. However, the applicability of these formulae for small fields has been questioned in the literature. Functional representation has also been proposed for small-field TPR production. This article compares measured TPR data for small 6 MV photon fields against that generated by conversion of PDD using standard formulae to assess the efficacy of the conversion data. By functionally fitting the measured TPR data for square fields greater than 4 cm in length, the TPR curves for smaller fields are generated and compared with measurements. TPRs and PDDs were measured in a water tank for a range of square field sizes. The PDDs were converted to TPRs using standard formulae. TPRs for fields of 4 × 4 cm{sup 2} and larger were used to create functional fits. The parameterization coefficients were used to construct extrapolated TPR curves for 1 × 1 cm{sup 2}, 2 × 2-cm{sup 2}, and 3 × 3-cm{sup 2} fields. The TPR data generated using standard formulae were in excellent agreement with direct TPR measurements. The TPR data for 1 × 1-cm{sup 2}, 2 × 2-cm{sup 2}, and 3 × 3-cm{sup 2} fields created by extrapolation of the larger field functional fits gave inaccurate initial results. The corresponding mean differences for the 3 fields were 4.0%, 2.0%, and 0.9%. Generation of TPR data using a standard PDD-conversion methodology has been shown to give good agreement with our directly measured data for small fields. However, extrapolation of TPR data using the functional fit to fields of 4 × 4 cm{sup 2} or larger resulted in generation of TPR curves that did not compare well with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study

This study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle{sup 3}, version 9.4). Radiation treatment plans for spine were prepared using VMAT (dual-arc), 7-field IMRT (beam angles: 110°, 130°, 150°, 180°, 210°, 230°, and 250°), and 4-field 3DCRT technique. The mean and maximum doses, dose-volume histograms, and volumes receiving more than 2 and 4 Gy to organs at risk (OARs) were calculated and compared. The lifetime risk for secondary cancers was estimated according to the National Cancer Registry Programme Report 116. VMAT delivered the lowest maximum dose to the esophagus (4.03 Gy), bone (8.11 Gy), heart (2.11 Gy), spinal cord (6.45 Gy), and whole lung (5.66 Gy) as compared with other techniques (IMRT and 3DCRT). The volumes of OAR (esophagus) receiving more than 4 Gy were 0% for VMAT, 27.06% for IMRT, and up to 32.35% for 3DCRT. The estimated risk for secondary cancer in the respective OAR is considerably lower in VMAT compared with other techniques. The results of maximum doses and volumes of OARs suggest that the risk of secondary cancer induction for the spine in VMAT is lower than IMRT and 3DCRT, whereas VMAT has the best target coverage compared with the other techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗