Prompt-delayed $\gamma$-ray spectroscopy with AGATA, EXOGAM and VAMOS++

Here, a new experimental setup to measure prompt-delayed γ-ray coincidences from isotopically identified fission fragments, over a wide time range of 100ns-200μ s, is presented. The fission fragments were isotopically identified, on an event-by-event basis, using the VAMOS++ large acceptance spectrometer. The prompt γ rays emitted at the target position and corresponding delayed γ rays emitted at the focal plane of the spectrometer were detected using, respectively, thirty two crystals of the AGATA γ-ray tracking array and seven EXOGAM HPGe Clover detectors. Finally, fission fragments produced in fusion and transfer-induced fission reactions, using a 238 U beam at an energy of 6.2 MeV/u impinging on a 9 Be target, were used to characterize and qualify the performance of the detection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-mass Star Formation in the Outer Scutum–Centaurus Arm

The Outer Scutum–Centaurus (OSC) spiral arm is the most distant molecular spiral arm in the Milky Way, but until recently little was known about this structure. Discovered by Dame and Thaddeus, the OSC lies ∼15 kpc from the Galactic Center. Due to the Galactic warp, it rises to nearly 4° above the Galactic Plane in the first Galactic quadrant, leaving it unsampled by most Galactic plane surveys. Here we observe H ii region candidates spatially coincident with the OSC using the Very Large Array to image radio continuum emission from 65 targets and the Green Bank Telescope to search for ammonia and water maser emission from 75 targets. This sample, drawn from the Wide-field Infrared Survey Explorer Catalog of Galactic H ii Regions, represents every H ii region candidate near the longitude–latitude (ℓ,b) locus of the OSC. Coupled with their characteristic mid-infrared morphologies, detection of radio continuum emission strongly suggests that a target is a bona fide H ii region. Detections of associated ammonia or water maser emission allow us to derive a kinematic distance and determine if the velocity of the region is consistent with that of the OSC. Nearly 60% of the observed sources were detected in radio continuum, and more than 20% have ammonia or water maser detections. The velocities of these sources mainly place them beyond the Solar orbit. These very distant high-mass stars have stellar spectral types as early as O4. We associate high-mass star formation at 2 new locations with the OSC, increasing the total number of detected H ii regions in the OSC to 12.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-Assembly of Nanostructured, Complex, Multi-cation Films via Spontaneous Phase Separation and Strain-driven Ordering

Spontaneous self-assembly of a multi-cation nanophase in another multi-cation matrix phase is a promising bottom-up approach to fabricate novel, nanocomposite structures for a range of applications. In an effort to understand the mechanisms for such self-assembly, we report on complimentary experimental and theoretical studies to first understand and then control or guide the self-assembly of insulating BaZrO3 (BZO) nanodots within REBa2Cu3O7- (RE=rare earth elements including Y, REBCO) superconducting films. It was determined that the strain field developed around BZO nanodots embedded in REBCO matrix is a key driving force dictating the self-assembly of BZO nanodots along REBCO c-axis. The size selection and spatial ordering of BZO self-assembly were simulated using thermodynamic and kinetic models. The BZO self-assembly was controllable by tuning the interphase strain field. REBCO superconducting films with BZO defects arrays self-assembled to align in both vertical (REBCO c-axis) and horizontal (REBCO ab-planes) directions, resulted in the maximized pinning and Jc performance for all field angles with smaller angular Jc anisotropy. The work has broad implications for fabrication of controlled self-assembled nanostructures for a range of applications via strain-tuning.

Nanomaterials↗

Magnetoelectric memory cells with domain-wall-mediated switching

A magnetoelectric memory cell with domain-wall-mediated switching is implemented using a split gate architecture. The split gate architecture allows a domain wall to be trapped within a magnetoelectric antiferromagnetic (MEAF) active layer. An extension of this architecture applies to multiple-gate linear arrays that can offer advantages in memory density, programmability, and logic functionality. Applying a small anisotropic in-plane shear strain to the MEAF can block domain wall precession to improve reliability and speed of switching.

42 ENGINEERING↗

Simple orientational control over cylindrical organic-inorganic block copolymer domains for etch mask applications.

Bottom-up patterning methodologies, predicated on chemical self-assembly, have the potential to transcend limitations associated with more traditional lithographies. By controlling the domain orientation of a cylinder-forming organic-inorganic block copolymer, poly(styrene-block-ferrocenyldimethylsilane), it is possible to straightforwardly fabricate massive arrays of either nanoscale dots or wires out of a film composed of a wide variety of materials. In the work reported here, orientational control is achieved by manipulating the polymer film thickness in concert with the annealing treatment. For films much thinner than the equilibrium periodicity of the microdomains, the cylinders spontaneously orient themselves perpendicular to the substrate. Films with thickness close to the equilibrium periodicity exhibit the more common in-plane orientation following thermal annealing. Solvent annealing leads to an in-plane orientation for the full range of film thicknesses studied. As a demonstration of the effectiveness of this method, semiconductor substrates were patterned with arrays of posts and wires, respectively, using the same starting polymeric material as the etch mask. Compatibility of this polymer with various substrate materials is also demonstrated.

36 MATERIALS SCIENCE↗

Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period was 5 s, with the resulting average motion speed of 1.45 cm/s. The motion-perturbed high resolution (2 mm voxel) volumetric dose grids on the MC2 phantom were generated for each beam. From each grid, a coronal dose plane at the detector level was extracted and compared to the corresponding moving MC2 measurement, using gamma analysis with both global (G) and local (L) dose-error normalization. Results: Using the TG-119 criteria of (3%G/3 mm), per beam average gamma analysis passing rates exceeded 95% in all cases. No individual beam had a passing rate below 91%. LDVE correction eliminated systematic disagreement patterns at the beams’ aperture edges. In a representative example, application of LDVE correction improved (2%L/2 mm) gamma analysis passing rate for an IMRT beam from 74% to 98%. Conclusions: The effect of motion on the moving region-of-interest IMRT dose can be estimated with a standard, static phantom QA measurement, provided the motion characteristics are independently known from 4D CT or otherwise. The motion-perturbed absolute dose estimates were validated by the direct planar diode array measurements, and were found to reliably agree with them in a homogeneous phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From Molecular to Macroscopic via the Rational Design of a Self-Assembled 3D DNA Crystal

We live in a macroscopic three-dimensional (3D) world, but our best description of the structure of matter is at the atomic and molecular scale. Understanding the relationship between the two scales requires a bridge from the molecular world to the macroscopic world. Connecting these two domains with atomic precision is a central goal of the natural sciences, but it requires high spatial control of the 3D structure of matter1. The simplest practical route to producing precisely designed 3D macroscopic objects is to form a crystalline arrangement by self-assembly, because such a periodic array has only conceptually simple requirements: a motif that has a robust 3D structure, dominant affinity interactions between parts of the motif when it self-associates, and predictable structures for these affinity interactions. Fulfilling these three criteria to produce a 3D periodic system is not easy, but should readily be achieved with well-structured branched DNA motifs tailed by sticky ends2. Complementary sticky ends associate with each other preferentially and assume the well-known B-DNA structure when they do so3; the helically repeating nature of DNA facilitates the construction of a periodic array. It is essential that the directions of propagation associated with the sticky ends do not share the same plane, but extend to form a 3D arrangement of matter. Here we report the crystal structure at 4?Angstroms resolution of a designed, self-assembled, 3D crystal based on the DNA tensegrity triangle4. The data demonstrate clearly that it is possible to design and self-assemble a well-ordered macromolecular 3D crystalline lattice with precise control.

36 MATERIALS SCIENCE↗

Spectroscopy of odd-proton nuclei in the region of {sup 254}No

Two rotational bands have been found in the transfermium nuclei {sup 251}Md and {sup 255}Lr, the latter being the heaviest nucleus so far studied in-beam. Both are assigned to a [521]1/2{sup -} Nilsson state by comparison to theory. The experiments have been carried out in the Accelerator Laboratory of the University of Jyvaeskylae (JYFL), where the array of germanium detectors JUROGAM was used in conjunction with the recoil-seperator RITU and the focal-plane setup GREAT for gamma-spectroscopic studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic and dielectric properties of one-dimensional array of S = 1/2 linear trimer system Na{sub 2}Cu{sub 3}Ge{sub 4}O{sub 12}

Magnetic susceptibility χ, specific heat C, capacitance C{sub p}, and {sup 23}Na-NMR measurements have been carried out on polycrystalline samples of quantum spin linear trimer system Na{sub 2}Cu{sub 3}Ge{sub 4}O{sub 12}, which has the one-dimensional array of Cu{sub 3}O{sub 8} trimers formed of edge-sharing three CuO{sub 4} square planes. The exchange interactions between the Cu{sup 2+} (S = 1/2) spins have been determined by analyzing χ-T and C-T curves. By employing the isolated S = 1/2 Heisenberg trimer model above 70 K, the nearest-neighbor exchange couplings J{sub 1} and the second-neighbor one J{sub 2} in trimer have been evaluated to J{sub 1}/k{sub B} = 30 ± 20 K (antiferromagnetic) and J{sub 2}/k{sub B} = 340 ± 20 K. At low temperature region, two spins of the edge in the Cu{sub 3}O{sub 8} trimers form a nonmagnetic singlet by strong antiferromagnetic interaction J{sub 2}, and the spin left in the center of the Cu{sub 3}O{sub 8} trimer forms one-dimensional chains by the exchange interaction J{sub 3} between the trimers. By employing the S = 1/2 uniform Heisenberg chain model below 70 K, we have evaluated to J{sub 3}/k{sub B} = 18 ± 1 K. The mechanism of multiferroic behavior at T{sub c} = 2 K is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single Channel Infrasound Detection Using Machine Learning

Infrasound, low frequency sound less than 20 Hz, is generated by both natural and anthropogenic sources. Infrasound sensors measure pressure fluctuations only in the vertical plane and are single channel. However, the most robust infrasound signal detection methods rely on stations with multiple sensors (arrays), despite the fact that these are sparse. Automated methods developed for seismic data, such as short-term average to long-term average ratio (STA/LTA), often have a high false alarm rate when applied to infrasound data. Leveraging single channel infrasound stations has the potential to decrease signal detection limits, though this cannot be done without a reliable detection method. Therefore, this report presents initial results using (1) a convolutional neural network (CNN) to detect infrasound signals and (2) unsupervised learning to gain insight into source type.

47 OTHER INSTRUMENTATION↗

New results near {sup 100}Sn : observation of single-neutron states in {sup 101}Sn.

A search for in-beam {gamma}-ray transitions in {sup 101}Sn, which contains only one neutron outside the {sup 100}Sn core, using a novel approach was carried out at the Argonne Tandem-Linac System. {sup 101}Sn nuclei were produced using the {sup 46}Ti({sup 58}Ni, 3n){sup 101}Sn fusion-evaporation reaction. Beta-delayed protons with energies and decay times consistent with previous {sup 101}Sn decay studies were observed at the focal plane of the Fragment Mass Analyzer. In-beam {gamma} rays were detected in the Gammasphere Ge-detector array and were correlated with the {sup 101}Sn {beta}-delayed protons using the Recoil-Decay Tagging method. As a result, a {gamma}-ray transition between the single-neutron {nu}g{sub 7/2} and {nu}d{sub 5/2} states situated at the Fermi surface was identified. The measured {nu}g{sub 7/2}-{nu}d{sub 5/2} energy splitting was compared with predictions corresponding to various mean-field potentials and was used to calculate multi-neutron configurations in light Sn isotopes. Similar approach can be used to study core excitations in {sup 101}Sn and other exotic nuclei near {sup 100}Sn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPTpol: an instrument for CMB polarization.

SPTpol will consist of an 850 element polarization sensitive bolometric camera deployed to the South Pole Telescope in late 2011. This camera is optimized for measurement of the polarization of the cosmic microwave background with arcminute resolution. These measurements will be used to constrain neutrino masses and to constrain the amplitude of gravitational waves from inflation. The camera includes two detector architectures that observe in two different frequency bands. At 150 GHz, SPTpol will use 650 feedhorn-coupled TES polarimeters fabricated at NIST. At 90 GHz, it will use 200 absorber-coupled polarimeters developed at Argonne National Lab. The NIST pixels will be coupled to the telescope using a monolithic array of corrugated feeds and the Argonne devices will be coupled with individually machined contoured feeds. The entire focal plane will be readout using a digital frequency-domain multiplexer system. We provide an overview of the project, describe the detectors and discuss the design of this system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A CLASS I AND CLASS II CH{sub 3}OH MASER SURVEY OF EGOs FROM THE GLIMPSE SURVEY

We present the results of a high angular resolution Very Large Array (VLA) Class I 44 GHz and Class II 6.7 GHz CH{sub 3}OH maser survey of a sample of {approx}20 massive young stellar object (MYSO) outflow candidates selected on the basis of extended 4.5 {mu}m emission in Spitzer Galactic Legacy Infrared Mid-Plane Survey Extraordinaire images. These 4.5 {mu}m selected candidates are referred to as extended green objects (EGOs), for the common coding of this band as green in three-color Infrared Array Camera images. The detection rate of 6.7 GHz Class II CH{sub 3}OH masers, which are associated exclusively with massive YSOs, toward EGOs is {approx}>64%-nearly double the detection rate of surveys using other MYSO selection criteria. The detection rate of Class I 44 GHz CH{sub 3}OH masers, which trace molecular outflows, is {approx}89% toward EGOs associated with 6.7 GHz CH{sub 3}OH masers. The two types of CH{sub 3}OH masers exhibit different spatial distributions: 6.7 GHz masers are centrally concentrated and usually coincide with 24 {mu}m emission, while 44 GHz masers are widely distributed and generally trace diffuse 4.5 {mu}m features. We also present results of a complementary James Clerk Maxwell Telescope (JCMT) single-pointing molecular line survey of EGOs in the outflow tracers HCO{sup +}(3-2) and SiO(5-4). The HCO{sup +} line profiles and high SiO detection rate (90%) are indicative of the presence of active outflows. No 44 GHz continuum emission is detected at the 5 mJy beam{sup -1} (5{sigma}) level toward 95% of EGOs surveyed, excluding bright ultracompact H II regions as powering sources for the 4.5 {mu}m outflows. The results of our surveys constitute strong evidence that EGOs are young, massive YSOs, with active outflows, presumably powered by ongoing accretion.

79 ASTRONOMY AND ASTROPHYSICS↗

Roughness of Ti Substrates for Control of the Preferred Orientation of TiO 2 Nanotube Arrays as a New Orientation Factor

We report the surface roughness of a Ti substrate as a critical factor for controlling the degree of the preferred orientation of anatase TiO2 nanotube arrays (NTAs) which are synthesized by anodization and a subsequent annealing process. The degree of the preferred orientation to the (004) plane of the anatase crystal structure has a strong dependency on the root-mean-square roughness (Sq) of the initial Ti substrate when the roughness-controlled substrates are anodized in an ethylene glycol-based electrolyte containing ~2 wt % of water. Highly preferred oriented NTAs were obtained from low-Sq (<10 nm) substrates, which were accompanied by uniform pore distribution and low concentration of hydroxyl ions in as-anodized amorphous NTAs. The mechanism of the preferred oriented crystallization of nanometer-scaled tube walls is explained considering the microscopic geometrical uniformity of the oxide barrier and nanopores at the early stage of anodization, which affected the local electric field and thus the insertion of the hydroxyl group into the amorphous TiO2 tube walls.

14 SOLAR ENERGY↗

SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes. The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.

60 APPLIED LIFE SCIENCES↗

The Synthesis, Structures, and Chemical Properties of Macrocyclic Ligands Covalently Bonded into Layered Arrays

In this part of the proposal we have concentrated on the surface functionalization of α-zirconium phosphate of composition Zr(O3POH)2•H2O. It is a layered compound that can be prepared as particles as small as 30 nm to single crystals in the range of cm. This compound is an ion exchanger with a capacity of 6.64 meq per gram. It finds use as a catalyst, proton conductor, sensors, biosensors, in kidney dialysis and drug delivery. By functionalizing the surface additional uses are contemplated as will be described. The layers consist of the metal, with 4+ charge, that is positioned slightly above and below the mean layer plane and bridged by three of the four phosphate oxygens. The remaining POH groups point into the interlayer space creating double rows of POH groups but single arrays on the surface layers. The surface groups are reactive and we were able to bond silanes, isocyanates, epoxides, acrylates ` and phosphates to the surface POH groups. The layers are easily exfoliated or filled with ions by ion exchange or molecules by intercalation reactions. Highlights of our work include, in addition to direct functionalization of the surfaces, replacement of the protons on the surface with ions of different charge. This allows us to bond phosphates, biophosphates, phosphonic acids and alcohols to the surface. By variation of the ion charge of the ions that replace the surface protons, different surface structures are obtained. We have already shown that polymer fillers, catalysts and Janus particles may be prepared. The combination of surface functionalization with the ability to insert molecules and ions between the layers allow for a rich development of numerous useful other applications as well as nano-surface chemistry.

36 MATERIALS SCIENCE↗

BATATA: a buried muon hodoscope

Muon hodoscopes have several applications, ranging from astrophysics to fundamental particle physics. In this work, we present a detector dedicated to the study, at ground level, of the main signals of cosmic-ray induced showers above 6 PeV. The whole detector is composed by a set of three parallel dual-layer scintillator planes buried at fix depths ranging from 120 g/cm{sup 2} to 600 g/cm{sup 2} and by a triangular array of water cerenkov detectors located nearby on ground.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron field parameter measurements on the JET tokamak by means of super-heated fluid detectors

The neutron field parameters (fluence and energy distribution) at a specific location outside the JET Torus Hall have been measured by means of super-heated fluid detectors (or 'bubble detectors') in combination with an independent, time-of-flight, technique. The bubble detector assemblies were placed at the end of a vertical line of sight at about 16 m from the tokamak mid plane. Spatial distributions of the neutron fluence along the radial and toroidal directions have been obtained using two-dimensional arrays of bubble detectors. Using a set of three bubble detector spectrometers the neutron energy distribution was determined over a broad energy range, from about 10 keV to above 10 MeV, with an energy resolution of about 30% at 2.5 MeV. The very broad energy response allowed for the identification of energy features far from the main fusion component (around 2.45 MeV for deuterium discharges).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗