Search NASA⌕ Search

SEARCH · Search NASA

Results for “power converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Modeling and Harmonic Stability of MMC-HVDC With Passive Circulating Current Filters

A modular multilevel converter (MMC) is an emerging converter technology widely used in wind power applications using high-voltage direct current (HVDC) transmission, and it has been largely investigated in medium-voltage solar harvesting as well as electric motor drives. Different from studies dealing with active circulating current control loops, this paper focuses on impedance modeling and harmonic stability studies for MMCs with passive circulating current filters (PCCFs). A power stage circuit including a PCCF is transformed and remodeled to obtain small-signal formulations. This transformation leads to additional high-order matrix computing complexity due to the added impedance subnetwork matrix from the PCCF as well as relevant crossed-frequency impacts. To simplify the computational burden, the proposed model aims to solve one arm equation instead of all six MMC arm equations. To achieve this result, additional challenges occur when the MMC is connected to a renewable energy source instead of the grid voltage, where low-level zero-sequence components might exist in the neutral point of three phases, especially in the case of no integrated advanced modular voltage balancing control, which prevents computational simplification. To overcome this challenge, further impedance matrix adjustments are conducted in this paper to theoretically suppress the impact of zero-sequence harmonics when obtaining small-signal impedance, taking into account the frequency coupling effect. Finally, simulations are carried out to validate the developed impedance model under different operating scenarios. Harmonic stability case studies of MMCs with PCCFs connected to renewable energy current sources are also presented, where frequency-domain stability analyses based on Bode diagrams are compared to time-domain simulation waveforms and FFTs, which validate the effectiveness of the proposed impedance model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 1MHz Oak Ridge AC / DC Converter for UAV Contactless Charger Implementation

In this paper, a 1 MHz single-phase Oak Ridge Converter (ORC) AC/DC wireless power transfer (WPT) system is introduced for unmanned air vehicle (UAV) charging applications. The proposed advanced solution eliminates the design, weight, volume, and the cost of the power factor correcting (PFC) front-end rectifier compared to the conventional practices. Additionally, grid power quality requirements can be achieved with the presented innovative idea. With this method, single stage WPT primary side uses the hybrid grid frequency and high frequency (60 Hz and 1 MHZ) from ac source through the coupler coils and to UAV battery with GaN FETs. Experimental results of the single-phase system is presented to confirm the mathematical analyses with the source voltage of 110 VAC, RMS and output voltage of 40 VDC at 1 kW power with 6 inches air gap between couplers. The primary coupler consists of a ferrite-backed single-turn coil with a radius of 1.5 ft, and the secondary coupler is made with an air-core single-turn coil with radius of 1.2 ft. The system overall ac to dc efficiency is measured 77 % acquiring 0.99 power factor (PF) and 3.3 % current total harmonic distortion (THD) at 1 kW power.

Asa, Erdem↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Charge-Based Droop Control Addressing Control Saturation for Low-Inertia Converters

With bulky dc-link capacitors/inductors, traditional voltage-source converters (VSCs) and current-source converters (CSCs) feature a large inertia to facilitate the converter control under large transients. To achieve high power density with reduced cost, low-inertia converters (LICs) featuring significantly reduced dc-link capacitors/inductors have attracted growing attention. However, without bulky dc-link energy buffer, LICs are prone to control saturation under large transients, resulting in undesired oscillation and instability. This issue cannot be managed by traditional proportional-integral based control due to the low inertia. And it will deteriorate when several LICs are connected in series. To address this challenge in LICs, a model-predictive control (MPC) with a computation-inexpensive feed-forward compensation method has been proposed to provide fast dynamic responses. But it would suffer control saturation under larger transients that degrades the control performance. In this article, a charge-based droop control (CDC) is proposed to address this remaining challenge. This paper firstly analyzes the control saturation challenge in LICs by using a tri-port soft-switching solid-state transformer as an example. Next, the operating principle of the proposed CDC are introduced. Two different implementation approaches are discussed in detail. Lastly, the proposed scheme is validated in simulation with a high-fidelity model of hardware prototype. As a result, the proposed CDC eliminated the 2 kHz oscillation and reduced the dc-link ripple and overshoot due to control saturation by 75% and 50%, respectively.

30 DIRECT ENERGY CONVERSION↗

Coupled-DC Module-Based Photovoltaic System With Power Mismatch-Tolerated Modulation

Here, this article presents a coupled-DC power module-based cascaded multilevel converter integrating utility-scale photovoltaic (PV) generations (coupled-DC-link power module (CDPM)-PV). CDPM-PV inherits merits such as modular structure, distributed maximum power point tracking (MPPT), direct distribution grid access, from cascaded H-bridge-based PV (CHB-PV) system. But, it supplies more flexible power routes than CHB-PV, through coupling different DC-links. Power routes are intended for enlarging the entire operating range including conditions of active power mismatch arising from nonideal elements such as partial shading and parameter variations. The system construction with its self-balancing principle is first introduced. Switching states for different operating regions are then derived based on the principle of easing implementation. Based on these, a modulation strategy including initial switching pattern selection and coordinated power routing is proposed to allow module-mismatches. Operating ranges are also analyzed and compared with conventional CHB-PV. Simulation results of a 3-MW/13.8-kV system developed in MATLAB/Simulink platform, and experiment results based on a 2.4-kW/311-V setup are presented and have demonstrated that the CDPM-PV topology with proposed modulation strategy can not only ride through a larger range of module mismatches, but also improve solar power utilization and system efficiency owing to noncompromised MPPT.

14 SOLAR ENERGY↗

Evaluation of Pozzolan-substituted Cast Stone for Pretreated Hanford Tank Waste

Portland cement. The future availability of quality Class F fly ash has come into question as coal-fired power plants are being converted to gas or taken offline. Consequently, alternative pozzolanic reagents are being evaluated for fly ash replacement in cementitious matrices for treating radioactive waste and debris. In 2023 and 2024, Savannah River National Laboratory (SRNL) was funded to evaluate natural pozzolans for the replacement of Class F fly in the Savannah River Site (SRS) Saltstone formulation. Based on the promising results and uncertain availability of Class F fly ash in the northwestern US, Hanford Tank Waste Operations & Closure, LLC (H2C) requested SRNL to evaluate the potential for substituting natural pozzolans in the Hanford West Area Pretreated Low Activity Tank Waste (PTW/LAW) Cast Stone formulation1 . Task 1 in this request was to determine the change in Cast Stone volume resulting from stabilization/solidification of 1 L of PTW/LAW tank waste. The densities of three (Hess Pumice, tephra pumice, and clinoptilolite zeolite) pozzolan-substituted Baseline Cast Stone mixes were determined, and volume changes relative to the fly ash-Baseline Mix with a water-to-dry mix = 0.40 were calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗

WEC-GRID

WEC-GRID is an open-source Python library crafted to simulate the integration of Wave Energy Converters (WECs) and Current Energy Converters (CECs) into renowned power grid simulators like PSS®E & PyPSA.

Barajas-Ritchie, Alexander↗

H3 Final Design and Technical Report

The goal of this Project was to develop a standards-compliant, fabrication-ready design of Columbia Power Technologies’ (C·Power) next-generation wave energy converter (WEC), the StingRAY H3p. The H3p is a design iteration of C·Power’s StingRAY WEC and is intended for electrical power generation suitable for micro-grids or remote loads. The H3p was designed for grid-connection and at least two years of continuous testing and operation at the proposed PacWave-South (PWS) test site.

16 TIDAL AND WAVE POWER↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

Fueling the Future: The Emergence of Self-Powered Enzymatic Biofuel Cell Biosensors

Self-powered biosensors are innovative devices that can detect and analyze biological or chemical substances without the need for an external power source. These biosensors can convert energy from the surrounding environment or the analyte itself into electrical signals for sensing and data transmission. The self-powered nature of these biosensors offers several advantages, such as portability, autonomy, and reduced waste generation from disposable batteries. They find applications in various fields, including healthcare, environmental monitoring, food safety, and wearable devices. While self-powered biosensors are a promising technology, there are still challenges to address, such as improving energy efficiency, sensitivity, and stability to make them more practical and widely adopted. This review article focuses on exploring the evolving trends in self-powered biosensor design, outlining potential advantages and limitations. With a focal point on enzymatic biofuel cell power generation, this article describes various sensing mechanisms that employ the analyte as substrate or fuel for the biocatalyst’s ability to generate current. Technical aspects of biofuel cells are also examined. Research and development in the field of self-powered biosensors is ongoing, and this review describes promising areas for further exploration within the field, identifying underexplored areas that could benefit from further investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biconjugate Impedance Matching Control of the HERO WEC: Preprint

Effective control strategies are essential for maximizing the power output of wave energy converters (WECs). In this study, we explore the methodology of port-based modelling which can be used for bi-conjugate impedance matching, a type of reactive control that involves maximizing power transfer by setting the load (PTO) impedance to be the complex conjugate of the source impedance (WEC). Despite its foundational role in electrical engineering, this method has seen limited application in wave energy and has not yet been demonstrated in wave-powered desalination systems. We represent our complex multidisciplinary system as an equivalent circuit to explore frequency-based relations. The HERO WEC, a small-scale, modular point absorber (PA) designed for reverse osmosis desalination is used as a case study to demonstrate port-based modelling for control applications. Improving the performance of wave-powered water desalination systems could play a critical role in addressing freshwater scarcity for coastal communities, especially those in remote or disaster-prone regions.

16 TIDAL AND WAVE POWER↗

Power capture and power take-off load of a self-balanced dual-flap oscillating surge wave energy converter

Wave energy converters are an important part of future renewable energy infrastructure. Predicting their power matrix, capture width ratio, and power take-off loads at a targeted site is required for performance assessment before deployment. Because their testing is very expensive, numerical modeling and simulations play a significant role in those assessments. Linear potential flow theory has limited accuracy under large amplitude wave forcing. More accurate predictions can be obtained by using higher-fidelity models, which are computationally expensive. We present a framework for multi-fidelity numerical simulations to determine the hydrodynamic response, wave capture capability, and power take-off load of a full-scale dual-flap oscillating surge wave energy converter. This design exploits out-of-phase motion by setting the distance between the flaps to half the wavelength of the most occurring wave. The simulations are validated using a 1:10 model experiments in a wave tank. Based on these validations, it was determined that Euler simulations provide an acceptable prediction with 90% reduction in computational time with only 11% error. Utilizing Euler simulations at full-scale, the results demonstrate that the annual electrical energy output is 1.79 GWh under regular wave conditions. Here, one significant improvement over single-flap designs is the capture width ratio which exceeds unity.

16 TIDAL AND WAVE POWER↗

Powering the Blue Economy: Marine Energy at Kelp Farm Sites

Marine energy (ME) has the potential to power businesses in the blue economy. Kelp farms are an emerging maritime market of the blue economy and are predicted to grow, but they are not currently using ME for their power needs. As the number and size of kelp farms increase, more offshore power will be needed onsite for operations, monitoring, and harvesting. ME devices such as tidal current energy converters and wave energy converters (WECs) may be used to supply power for these needs. This article assesses the status of kelp farming in the continental United States, investigates the electricity needs of kelp farms, and examinesthe feasibility of generating the required electricity from wave and tidal current energy. The United States currently has 165 kelp farms that have either active or pending permits. The farms use electricity for boat operations, kelp drying, environmental monitoring, offshore lighting, and the raising and lowering of lines. Most kelp farms are in protected, nearshore waters that do not have significant wave energy resources. The limited available wave energy could be used to power small devices, but WECs have not yet been developed for that application. Some kelp farms are in locations that feature significant tidal energy resources, but small tidal current energy converters that are compatible with existing farm operations are not yet commercially available. As low-power WECs and tidal current energy converters are developed, kelp farms could be research partners and early adopters of the new technologies, which would encourage their broader use by other blue economy businesses.

16 TIDAL AND WAVE POWER↗

Low-cost connectors for inverters and converters and methods of manufacturing and using the same

In some embodiments, systems and methods for connector assembly for use with an AC or DC power interface of a power conversion device, such as a converter and an inverter, are provided. The connector assembly can include a circuit board, a power connector, and a pin. The power connector can have a base configured to be secured relative to the circuit board and define a first channel extending through the power connector along a first channel axis. The first pin can have a first pin body that extends along a first pin axis and a first connection element that extends along the first pin axis from the first pin body to a first terminal end that is skewed relative to the first pin axis.

Khaligh, Alireza↗