Search NASA⌕ Search

SEARCH · Search NASA

Results for “predictive control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high-fidelity building performance simulation test bed for the development and evaluation of advanced controls

We present an open-source building performance simulation test bed, the Advanced Controls Test Bed (ACTB), that interfaces high-fidelity Spawn of EnergyPlus building models, with advanced controllers implemented in Python. Additionally, the ACTB leverages the Building Optimization Testing and Alfalfa platforms for managing simulations, providing an external clock, a representational state transfer (REST) application programming interface (API), and key performance indicators for evaluating the effectiveness of control strategies. The REST API allows the development of external controllers programmed in languages such as Python, which provides flexibility and a rich choice of scientific libraries for designing control sequences. We present three test cases based on the U.S. Department of Energy's Reference Small Office Building to demonstrate the ACTB's capabilities: (a) rule-based controls compliant with ASHRAE Guideline 36 control sequences; (b) an economic model predictive control implemented using do-mpc; and (c) a deep Q-network reinforcement learning agent implemented using OpenAI Gym.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting plug loads with occupant count data through a deep learning approach

Predictive control has gained increasing attention for its ability to reduce energy consumption and improve occupant comfort in buildings. The plug loads prediction is a key component for the predictive building controls, as plug loads is a major source of internal heat gains in buildings. This study proposed a novel method to apply the Long-Short-Term-Memory (LSTM) Network, a special form of Recurrent Neural Network, to predict plug loads. The occupant count and the time have been confirmed to drive the plug load profile and thus selected as the features for the plug load prediction. The LSTM network was trained and tested with ground truth occupant count data collected from a real office building in Berkeley, California. Results from the LSTM network markedly improve the prediction accuracy compared with traditional linear regression methods and the classical Artificial Neural Network. 95% of 1-hour predictions from LSTM network are within ±1 kW of the actual plug loads, given the average plug loads during the office hour is 8.6 kW. The CV(RMSE) of the predicted plug load is 11% for the next hour, and 20% for the next eight hours. Lastly, we compared four prediction approaches with the office building we monitored: LSTM vs. ARIMA, with occupant counts vs. without occupant counts. It was found, the prediction error of the LSTM approach is around 4% less than the ARIMA approach. Using occupant counts as an exogenous input could further reduce the prediction error by 5%-6%. The findings of this paper could shed light on the plug load prediction for building control optimizations such as model-predictive control.

Occupant count↗

Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Further Investigation of Receding Horizion-Based Controllers and Neural Network-Based Systems

This report provides a comprehensive summary of the research work performed over the entire duration of the co-operative research agreement between NASA Langley Research Center and Kansas State University. This summary briefly lists the findings and also suggests possible future directions for the continuation of the subject research in the area of Generalized Predictive Control (GPC) and Network Based Generalized Predictive Control (NGPC).

Kelkar, Atul G.↗

A Novel Secondary Frequency Regulation with Optimal Priority Selection of AGC Contributions

Automatic generation control (AGC) is used to maintain acceptable frequencies during operation owing to fluctuations in load and variable resources. In conventional industry applications, the AGC signal is allocated to each generator according to the predispatched frequency regulation capacity or the order of economic efficiency. However, with the increasing integration of inverter-based resources (IBRs), the retirement of conventional synchronous generators (SGs) has posed new challenges to frequency control schemes because fewer of them are optional for AGC regulation. In this paper, we propose a novel model predictive control (MPC)-based frequency regulation model to reduce control cost and ensure stability, by considering different critical dynamic factors when optimally selecting the AGC units. The proposed control model – developed in a general form – comprehensively embeds characteristics such as generator ramping rates, reserve capacity, and operation cost. The model predictive control–based two-timescale AGC scheme enhances the capability of immunizing the power disturbance from types of resources by coordinating the control signals between faster IBRs and slower SGs. The case study’s proposed model is verified to be effective in synergistically enforcing different dynamic properties of AGC units into the frequency regulation scheme.

Jiang, Sufan [The University of North Carolina at ↗

Advanced Control Systems for Wave Energy Converters

This submission contains several papers, a final report, descriptions of a theoretical framework for two types of control systems, and descriptions of eight real-time flap load control policies with the objective of assessing the potential improvement of annual average capture efficiency at a reference site on an MHK device developed by Resolute Marine Energy, Inc. (RME). The submission also contains an LCOE model that estimates the performance and related energy cost improvements that each advanced control system might provide and recommendations for improving DOE's LCOE model. The two types of control systems are for wave energy converters which transform data into commands that, in the case of RME's OWSC wave energy converter, provide real-time adjustments to damping forces applied to the prime mover via the power take-off system (PTO). The control theories developed were: 1) Model Predictive Control (MPC) or so-called "non-causal" control whereby sensors deployed seaward of a wave energy converter measure incoming wave characteristics and transmit that information to a data processor which issues commands to the PTO to adjust the damping force to an optimal value; and 2) "Causal" control which utilizes local sensors on the wave energy converter itself to transmit information to a data processor which then issues appropriate commands to the PTO. The two advanced control policies developed by Scruggs and Re Vision were then compared to a simple control policy, Coulomb damping, which was utilized by RME during the two rounds of ocean trials it had conducted prior to the commencement of this project. The project work plan initially included a provision for RME to conduct hardware-in-the-loop (HIL) testing of the data processors and configurations of valves, sensors and rectifiers needed to implement the two advanced control systems developed by Scruggs and Re Vision Consulting but the funding for that aspect of the project was cut at the conclusion of Budget Period 1. Accordingly, more work needs to be done to determine: a) means and feasibility of implementing real-time control; and b) added costs associated with such implementation taking into account estimated effects on system availability in addition to component costs.

16 TIDAL AND WAVE POWER↗

Hierarchical multi-time-scale predictive thermal management and fuel optimization for heavy-duty compression ignition engines

For heavy-duty diesel engines, NO X emissions reduction is strongly constrained by fuel efficiency. This paper presents a hierarchical model predictive controller (H-MPC) for coordinated control of tailpipe NO X emissions and fuel consumption. The H-MPC uses the separation of slow and fast dynamics that exist in the engine and its aftertreatment system. The controller is synthesized with an architecture in which a high-level MPC uses a longer prediction horizon compared to the low-level predictive controller which tracks the high-level controller command and manages the thermal dynamics of the aftertreatment system. Engine load preview enables the high-level controller to estimate the desired catalyst temperature ahead of time and addresses the selective catalytic reduction (SCR) slow thermal dynamics. Calculated by the high-level controller, the intake manifold pressure, and the start of injection (SOI) crank angle is used as reference trajectories in the low-level controller that regulates fast dynamical behaviors such as engine out NO X emissions. Hardware-in-the-loop (HIL) validation of this integrated H-MPC on a rapid prototype controller shows that when the SCR catalyst temperature is above light-off temperature (warmed-up condition), the engine operation is shifted to operate with the best fuel economy since the warmed-up SCR can efficiently reduce the engine-out NO X emissions. Results indicate that up to 0.8% benefit in cycle averaged BSFC along with a 13% reduction in tailpipe NO X compared to a stock engine calibration can be achieved with the coordinated engine and aftertreatment system through H-MPC.

Engineering↗

Hybrid zero-voltage switching (ZVS) control for power inverters

A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictions of Control Inputs, Periodic Responses and Damping Levels of an Isolated Experimental Rotor in Trimmed Flight

Since the early 1990s the Aeroflightdynamics Directorate at the Ames Research Center has been conducting tests on isolated hingeless rotors in hover and forward flight. The primary objective is to generate a database on aeroelastic stability in trimmed flight for torsionally soft rotors at realistic tip speeds. The rotor test model has four soft inplane blades of NACA 0012 airfoil section with low torsional stiffness. The collective pitch and shaft tilt are set prior to each test run, and then the rotor is trimmed in the following sense: the longitudinal and lateral cyclic pitch controls are adjusted through a swashplate to minimize the 1/rev flapping moment at the 12 percent radial station. In hover, the database comprises lag regressive-mode damping with pitch variations. In forward flight the database comprises cyclic pitch controls, root flap moment and lag regressive-mode damping with advance ratio, shaft angle and pitch variations. This report presents the predictions and their correlation with the database. A modal analysis is used, in which nonrotating modes in flap bending, lag bending and torsion are computed from the measured blade mass and stiffness distributions. The airfoil aerodynamics is represented by the ONERA dynamic stall models of lift, drag and pitching moment, and the wake dynamics is represented by a state-space wake model. The trim analysis of finding, the cyclic controls and the corresponding, periodic responses is based on periodic shooting with damped Newton iteration; the Floquet transition matrix (FTM) comes out as a byproduct. The stabillty analysis of finding the frequencies and damping levels is based on the eigenvalue-eigenvector analysis of the FTM. All the structural and aerodynamic states are included from modeling to trim analysis. A major finding is that dynamic wake dramatically improves the correlation for the lateral cyclic pitch control. Overall, the correlation is fairly good.

Gaonkar, G. H.↗

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC↗

WE-E-17A-03: FDG-PET-Based Radiomics to Predict Local Control and Survival Following Radiotherapy

Purpose: An exploding field in cancer research is “radiomics,” based on the hypothesis that there is statistical (hidden) information in medical images that is prognostic or predictive of outcomes. Our group has developed an efficient pipeline to extract and analyze quantitative image features from medical images as related to outcomes or diagnosis. In this work, we summarize our previous studies with positron emission tomography (PET) images and show the potential of the use of radiomics for outcomes research. Methods: We analyzed two cancer datasets, each consisting of pre-radiotherapy-treatment PET scans: 163 T1-2N0M0 non-small cell lung cancer (NSCLC) patients and 174 head and neck (H and N) cancer patients with stage III–IV. The PET scans were converted to Computational Environment for Radiological Research (CERR) format, and CERR was used to generate 24 shape, texture, and intensity-histogram based image features. Data-mining and logistic regression methods were then used to model local failure (LF) and overall survival (OS). Unbiased estimates of performance were generated using leave-one-out cross-validation (LOOCV). Results: For predicting LF, the models with biologically equivalent dose (BED) and TLG (metabolic tumor volume (MTV) x SUVmean) in NSCLC, and skewness and MTV in H and N, achieved the best performance with AUC=0.818 (p<0.0001) and AUC=0.826 (p=0.0002), respectively. For predicting OS, the models with kurtosis and volume in NSCLC and SUVmax and homogeneity in H and N achieved the best performance with AUC=0.706 (p<0.0001) and AUC=0.656 (p=0.0003), respectively. On LOOCV, all these models retained significant predictive power. Interestingly, MTV was highly correlated with LF in both sites. Conclusion: PET-based imaged features are promising tools for improving treatment management decision making. Much more research is needed to identify optimal radiomics metrics and to correlate imaging phenotype with other clinical or genomic information.

60 APPLIED LIFE SCIENCES↗

Coordination and Control of Building HVAC Systems to Provide Frequency Regulation to the Electric Grid

Buildings consume 73% of electricity produced in the United States and, currently, they are largely passive participants in the electric grid. However, the flexibility in building loads can be exploited to provide ancillary services to enhance the grid reliability. In this paper, we investigate two control strategies that allow Heating, Ventilation and Air-Conditioning (HVAC) systems in commercial and residential buildings to provide frequency regulation services to the grid while maintaining occupants comfort. The first optimal control strategy is based on model predictive control acting on a variable air volume HVAC system (continuously variable HVAC load), which is available in large commercial buildings. The second strategy is rule-based control acting on an aggregate of on/off HVAC systems, which are available in residential buildings in addition to many small to medium size commercial buildings. Hardware constraints that include limiting the switching between the different states for on/off HVAC units to maintain their lifetimes are considered. Furthermore, simulations illustrate that the proposed control strategies provide frequency regulation to the grid, without affecting the indoor climate significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Diagnostic Suite for Electron Beam Prediction and Control at FACET-II

We discuss the implementation of a suite of virtual diagnostics at the FACET-II facility currently under commissioning at SLAC National Accelerator Laboratory. The diagnostics will be used for the prediction of the longitudinal phase space along the linac, spectral reconstruction of the bunch profile, and non-destructive inference of transverse beam quality (emittance) while using edge radiation at the injector dogleg and bunch compressor locations. These measurements will be folded into adaptive feedbacks and Machine Learning (ML)-based reinforcement learning controls to improve the stability and optimize the performance of the machine for different experimental configurations. In this paper we describe each of these diagnostics with expected measurement results that are based on simulation data and discuss progress towards implementation in regular operations.

Emma, Claudio (ORCID:0000000247191831)↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Additional Degree of Freedom for WEC Model

'Additional Degree of Freedom for WEC' - WEC-Sim numerical model from RFTS 1 TEAMER project. An increase in wave energy converter (WEC) efficiency requires not only consideration of the nonlinear effects in the WEC dynamics and the power take-off (PTO) mechanisms, but also more integrated treatment of the whole system, i.e., the buoy dynamics, the PTO system, and the control strategy. It results in an optimization formulation that has a nonquadratic and nonstandard cost functional. This model presents the application of real-time nonlinear model predictive controller (NMPC) to two degrees of freedom point absorber type WEC with highly nonlinear PTO characteristics. The nonlinear effects, such as the fluid viscous drag, are also included in the plant dynamics. The controller may be implemented on a real-time target machine, and the WEC device is emulated in real-time using the WECSIM toolbox. Please see the ‘ReadMe’ within the root directory for an explanation of how to set-up and run the model. An article covering the development of this model is attached as "Real-Time Nonlinear Model Predictive Controller for Multiple Degrees of Freedom Wave Energy Converters with Non-Ideal Power Take-Off"

16 TIDAL AND WAVE POWER↗