Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Quantitative Evaluation of Autonomous Driving in CARLA

There has been a great deal of recent advancements in end-to-end imitation and reinforcement learning for self-driving vehicles. Despite this, there is a severe lack of standardized metrics for evaluating the performance of autonomous self-driving agents. Existing metrics are generally lacking in their ability to capture a wide range of driving behaviors and compare the severity of different failure cases. In this work, we introduce the Quantitative Evaluation for Driving metric, or QED, which assigns a quantitative score from 0-100 that captures the quality of driving for any driving agent. Our QED metric assesses different aspects of driving behavior including the ability to stay in the center of the lane, avoid weaving and erratic behavior, follow the speed limit, and avoid collisions, and it can be used under a wide range of driving scenarios. To show the effectiveness of our QED metric, we compare the scores generated by QED against scores assigned by human evaluators on a total of 30 different drivers and 6 different towns in the CARLA driving simulator. In ``easy'' evaluation scenarios, where it is relatively straightforward to distinguish better drivers from worse drivers, QED attains an average Pearson correlation of 0.96 and average Spearman correlation of 0.97 when compared against human evaluators. In ``hard'' evaluation scenarios, where it is far more ambiguous how to rank/score different types of bad driving behavior, QED attains an average Pearson correlation of 0.82 and average Spearman correlation of 0.75 when compared against human evaluators, which are both slighter higher than when we compare human evaluators against each other. While QED may not capture every characteristic that defines good driving, we consider it an important foundation for reproducibility and standardization in the community.

Gao, Shang↗

Quantitative Assessment of Transportation Network Vulnerability with Dynamic Traffic Simulation Methods

Transportation networks are critical to the social and economic function of nations. Given the continuing increase in the populations of cities throughout the world, the criticality of transportation infrastructure is expected to increase. Thus, it is ever more important to mitigate congestion as well as to assess the impact disruptions would have on individuals who depend on transportation for their work and livelihood. Moreover, several government organizations are responsible for ensuring transportation networks are available despite the constant threat of natural disasters and terrorist activities. Most of the previous transportation network vulnerability research has been performed in the context of static traffic models, many of which are formulated as traditional optimization problems. However, transportation networks are dynamic because their usage varies over time. Thus, more appropriate methods to characterize the vulnerability of transportation networks should consider their dynamic properties. This paper presents a quantitative approach to assess the vulnerability of a transportation network to disruptions with methods from traffic simulation. Our approach can prioritize the critical links over time and is generalizable to the case where both link and node disruptions are of concern. We illustrate the approach through a series of examples. Our results demonstrate that the approach provides quantitative insight into the time varying criticality of links. Such an approach could be used as the objective function of less traditional optimization methods that use simulation and other techniques to evaluate the relative utility of a particular network defense to reduce vulnerability and increase resilience.

Shekar, Venkateswaran↗

Optimal Nested Test Plan for Combinatorial Quantitative Group Testing

We consider the quantitative group testing problem where the objective is to identify defective items in a given population based on results of tests performed on subsets of the population. Under the quantitative group testing model, the result of each test reveals the number of defective items in the tested group. The minimum number of tests achievable by nested test plans was established by Aigner and Schughart in 1985 within a minimax framework. Furthermore, the optimal nested test plan offering this performance, however, was not obtained. In this paper, we establish the optimal nested test plan in a closed form. This optimal nested test plan is also order optimal among all test plans as the population size approaches infinity. Using heavy-hitter detection as a case study, we show via simulation examples orders of magnitude improvement of the group testing approach over two prevailing sampling-based approaches in detection accuracy and counter consumption. Other applications include anomaly detection and wideband spectrum sensing in cognitive radio systems.

97 MATHEMATICS AND COMPUTING↗

How state transitions balance photosynthetic electron transport in plants – a quantitative study

In plants, the process of state transition regulates the allocation of sunlight energy between Photosystem II (PSII) and PSI. However, the implications of state transitions for harmonizing electron transport rates between photosystems, and a full quantitative picture of this process, remain underexplored. We integrated quantitative biology (biochemical and biophysical approaches) with in vivo spectroscopy on wild-type Arabidopsis and protein phosphorylation mutants. This combination facilitated monitoring of Chl redistribution and its functional implications for light harvesting and electron transport. Our findings demonstrate the reallocation of 12% of highly phosphorylated ‘extra’ light-harvesting complex II under state 2 from stacked to unstacked thylakoids. This reduces the number of Chls per PSII from 216 to 182, while increasing the number in PSI from 187 to 223. Such Chl redistribution compensates for differences in photosystem stoichiometry and photochemical quantum efficiencies, thereby precisely synchronizing electron transport rates in both photosystems. Mutant analyses corroborate that this regulatory mechanism involves reversible phosphorylation. We inferred that state transitions optimize linear electron transport, leaving no additional capacity for cyclic electron transport. Furthermore, the results suggest that the controversies about long-range migration of LHCII from stacked to unstacked thylakoid domains arise from differences in phosphorylation levels.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Risk Assessment of Norovirus Transmission in Food Establishments: Evaluating the Impact of Intervention Strategies and Food Employee Behavior on the Risk Associated with Norovirus in Foods

Abstract We developed a quantitative risk assessment model using a discrete event framework to quantify and study the risk associated with norovirus transmission to consumers through food contaminated by infected food employees in a retail food setting. This study focused on the impact of ill food workers experiencing symptoms of diarrhea and vomiting and potential control measures for the transmission of norovirus to foods. The model examined the behavior of food employees regarding exclusion from work while ill and after symptom resolution and preventive measures limiting food contamination during preparation. The mean numbers of infected customers estimated for 21 scenarios were compared to the estimate for a baseline scenario representing current practices. Results show that prevention strategies examined could not prevent norovirus transmission to food when a symptomatic employee was present in the food establishment. Compliance with exclusion from work of symptomatic food employees is thus critical, with an estimated range of 75–226% of the baseline mean for full to no compliance, respectively. Results also suggest that efficient handwashing, handwashing frequency associated with gloving compliance, and elimination of contact between hands, faucets, and door handles in restrooms reduced the mean number of infected customers to 58%, 62%, and 75% of the baseline, respectively. This study provides quantitative data to evaluate the relative efficacy of policy and practices at retail to reduce norovirus illnesses and provides new insights into the interactions and interplay of prevention strategies and compliance in reducing transmission of foodborne norovirus.

Duret, Steven↗

Tricin‐lignins: occurrence and quantitation of tricin in relation to phylogeny

Summary Tricin [5,7‐dihydroxy‐2‐(4‐hydroxy‐3,5‐dimethoxyphenyl)‐4H‐chromen‐4‐one], a flavone, was recently established as an authentic monomer in grass lignification that likely functions as a nucleation site. It is linked onto lignin as an aryl alkyl ether by radical coupling with monolignols or their acylated analogs. However, the level of tricin that incorporates into lignin remains unclear. Herein, three lignin characterization methods: acidolysis; thioacidolysis; and derivatization followed by reductive cleavage; were applied to quantitatively assess the amount of lignin‐integrated tricin. Their efficiencies at cleaving the tricin‐(4′– O– β)‐ether bonds and the degradation of tricin under the corresponding reaction conditions were evaluated. A hexadeuterated tricin analog was synthesized as an internal standard for accurate quantitation purposes. Thioacidolysis proved to be the most efficient method, liberating more than 91% of the tricin with little degradation. A survey of different seed‐plant species for the occurrence and content of tricin showed that it is widely distributed in the lignin from species in the family Poaceae (order Poales). Tricin occurs at low levels in some commelinid monocotyledon families outside the Poaceae, such as the Arecaceae (the palms, order Arecales) and Bromeliaceae (Poales), and the non‐commelinid monocotyledon family Orchidaceae (Orchidales). One eudicotyledon was found to have tricin ( Medicago sativa , Fabaceae). The content of lignin‐integrated tricin is much higher than the extractable tricin level in all cases. Lignins, including waste lignin streams from biomass processing, could therefore provide a large and alternative source of this valuable flavone, reducing the costs, and encouraging studies into its application beyond its current roles.

59 BASIC BIOLOGICAL SCIENCES↗

Surface and grain boundary scattering in nanometric Cu thin films: A quantitative analysis including twin boundaries

The relative contributions of various defects to the measured resistivity in nanocrystalline Cu were investigated, including a quantitative account of twin-boundary scattering. It has been difficult to quantitatively assess the impact twin boundary scattering has on the classical size effect of electrical resistivity, due to limitations in characterizing twin boundaries in nanocrystalline Cu. In this study, crystal orientation maps of nanocrystalline Cu films were obtained via precession-assisted electron diffraction in the transmission electron microscope. These orientation images were used to characterize grain boundaries and to measure the average grain size of a microstructure, with and without considering twin boundaries. The results of these studies indicate that the contribution from grain-boundary scattering is the dominant factor (as compared to surface scattering) leading to enhanced resistivity. The resistivity data can be well-described by the combined Fuchs–Sondheimer surface scattering model and Mayadas–Shatzkes grain-boundary scattering model using Matthiessen's rule with a surface specularity coefficient of p = 0.48 and a grain-boundary reflection coefficient of R = 0.26.

36 MATERIALS SCIENCE↗

Quantitative imaging of trace B in Si and SiO{sub 2} using ToF-SIMS

Changes in the oxidation state of an element can result in significant changes in the ionization efficiency and hence signal intensity during secondary ion mass spectrometry (SIMS) analysis; this is referred to as the SIMS matrix effect [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. The SIMS matrix effect complicates quantitative analysis. Quantification of SIMS data requires the determination of relative sensitivity factors (RSFs), which can be used to convert the as measured intensity into concentration units [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. In this manuscript, the authors report both: RSFs which were determined for quantification of B in Si and SiO{sub 2} matrices using a dual beam time of flight secondary ion mass spectrometry (ToF-SIMS) instrument and the protocol they are using to provide quantitative ToF-SIMS images and line scan traces. The authors also compare RSF values that were determined using oxygen and Ar ion beams for erosion, discuss the problems that can be encountered when bulk calibration samples are used to determine RSFs, and remind the reader that errors in molecular details of the matrix (density, volume, etc.) that are used to convert from atoms/cm{sup 3} to other concentration units will propagate into errors in the determined concentrations.

42 ENGINEERING↗

Implementation and validation of an ultrasonic tissue characterization technique for quantitative assessment of normal-tissue toxicity in radiation therapy

The goal of this study was to implement and validate a noninvasive, quantitative ultrasonic technique for accurate and reproducible measurement of normal-tissue toxicity in radiation therapy. The authors adapted an existing ultrasonic tissue characterization (UTC) technique that used a calibrated 1D spectrum based on region-of-interest analysis. They modified the calibration procedure by using a reference phantom instead of a planar reflector. This UTC method utilized ultrasonic radio-frequency echo signals to generate spectral parameters related to the physical properties (e.g., size, shape, and relative acoustic impedance) of tissue microstructures. Three spectral parameters were investigated for quantification of normal-tissue injury: Spectral slope, intercept, and midband fit. They conducted a tissue-mimicking phantom study to verify the reproducibility of UTC measurements and initiated a clinical study of radiation-induced breast-tissue toxicity. Spectral parameter values from measurements on two phantoms were reproducible within 1% of each other. Eleven postradiation breast-cancer patients were studied and significant differences between the irradiated and untreated (contralateral) breasts were observed for spectral intercept (p=0.003) and midband fit (p<0.001) but not for slope (p=0.14). In comparison to the untreated breast, the average difference in the spectral intercept was 2.99{+-}0.75 dB and the average difference in the midband fit was 3.99{+-}0.65 dB. The preliminary clinical study demonstrated the feasibility of using the quantitative ultrasonic method to evaluate normal-tissue toxicity in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: A cardiac phantom study

Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative method which corrects for the influences of these parameters using a linear moving cardiac phantom. Methods: On a robotic arm with artificial arteries with four calcifications of increasing density, a linear movement was applied between 0 and 120 mm/s (step of 10 mm/s). The phantom was scanned five times on 64-slice MDCT, DSCT, and EBT using a standard acquisition protocol. The average Agatston, volume, and mass scores were determined for each velocity, calcification, and scanner. Susceptibility to motion was quantified using a cardiac motion susceptibility (CMS) index. Resemblance to EBT and physical volume and mass was quantified using a {Delta} index. Results: Increasing motion artifacts were observed at increasing velocities on all scanners, with increasing severity from EBT to DSCT to 64-slice MDCT. The calcium score showed a linear dependency on motion from which a correction factor could be derived. This correction factor showed a linear dependency on the mean calcification density with a good fit for all three scoring methods and all three scanners (0.73{<=}R{sup 2}{<=}0.95). The slope and offset of this correction factor showed a linear dependency on temporal resolution with a good fit for all three scoring methods and all three scanners (0.83{<=}R{sup 2}{<=}0.98). CMS was minimal for EBT and increasing values were observed for DSCT and highest values for 64-slice MDCT. CMS was minimal for mass score and increasing values were observed for volume score and highest values for Agatston score. For all densities and scoring methods DSCT showed on average the closest resemblance to EBT calcium scores. When using the correction factor, CMS index decreased on average by 15% and {Delta} index decreased by 35%. Conclusions: Calcium scores determined on DSCT and 64-slice MDCT are highly susceptible to motion as compared to EBT. The mass score is less susceptible to motion compared to volume and Agatston score. Calcium scores determined on DSCT bear a closer resemblance to EBT obtained calcium scores than 64-slice MDCT. In addition, the calcium score is highly dependent on the average density of individual calcifications and the dependency of the calcium score on motion showed a linear behavior on calcification density. From these relations, a quantitative method could be derived which corrects the measured calcium score for the influence of linear motion, mean calcification density, and temporal resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative comparison of noise texture across CT scanners from different manufacturers

Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

60 APPLIED LIFE SCIENCES↗

Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy

Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-229: Quantitative Assessment for Timely Adaptive Re-Planning Using Weekly Dose Monitoring for Head and Neck Cancer

Purpose: For patients with head and neck (HN) cancer, mid-course adaptive radiation therapy (ART) is a common practice in our institution to accommodate anatomic changes. The aim of the study is to evaluate whether dose re-calculation on weekly verification images can provide quantitative assessment for timely adaptive re-planning with daily image-guided intensity modulated radiotherapy (IMRT). Methods: We retrospectively selected sixty daily verification images acquired on CT-on-rail/CBCT from ten HN patients. These image sets were typically a week apart. Among these patients, six patients received a mid-course ART. Contours of the tumors and organ-at-risks (OARs) were manually delineated by a physician on each verification CT. After placing the treatment iso-center on the verification CTs according to the recorded clinical shifts, daily dose was re-calculated with the same beam configuration as the original plan. For the purpose of this study, electron densities for both verification CTs and planning CTs were set to 1.0 g/cm3. Results: Two patients had D99 of the CTV < 97% of the planned dose for more than three fractions due to remarkable tumor volume shrinkages. D-max of the spinal cord exceeded a tolerance of 45 Gy for four fractions in additional two patients. D-mean of the parotid increased within 25% of the planned value. D-max of the brainstem and D-mean of the oral cavity did not show significant variation. If the re-planning criteria included D99 of the CTV < 97% of the planned dose and D-max of the spinal cord > 45 Gy, two out ten patients required ART at week 2 and two patients required ART at week 3, respectively. Conclusion: Weekly dose monitoring with re-calculation on verification images can provide quantitative dose guidance for timely adaptive re-planning. Future work will include accumulative dose analysis for the decision of adaptive re-planning. The study is supported in part by Siemens Medical Solutions.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-16: Reproducibility of Computed Tomography Quantitative Structural Features Using the FDA Thoracic Phantom Image Database

Purpose: To assess the reproducibility of quantitative structural features using images from the computed tomography thoracic FDA phantom database under different scanning conditions. Methods: Development of quantitative image features to describe lesion shape and size, beyond conventional RECIST measures, is an evolving area of research in need of benchmarking standards. Gavrielides et al. (2010) scanned a FDA-developed thoracic phantom with nodules of various Hounsfield units (HU) values, shapes and sizes close to vascular structures using several scanners and varying scanning conditions/parameters; these images are in the public domain. We tested six structural features, namely, Convexity, Perimeter, Major Axis, Minor Axis, Extent Mean and Eccentricity, to characterize lung nodules. Convexity measures lesion irregularity referenced to a convex surface. Previously, we showed it to have prognostic value in lung adenocarcinoma. The above metrics and RECIST measures were evaluated on three spiculated (8mm/-300HU, 12mm/+30HU and 15mm/+30HU) and two non-spiculated (8mm/+100HU and 10mm/+100HU) nodules (from layout 2) imaged at three different mAs values: 25, 100 and 200 mAs; on a Phillips scanner (16-slice Mx8000-IDT; 3mm slice thickness). The nodules were segmented semi-automatically using a commercial software tool; the same HU range was used for all nodules. Results: Analysis showed convexity having the lowest maximum coefficient of variation (MCV): 1.1% and 0.6% for spiculated and non-spiculated nodules, respectively, much lower compared to RECIST Major and Minor axes whose MCV were 10.1% and 13.4% for spiculated, and 1.9% and 2.3% for non-spiculated nodules, respectively, across the various mAs. MCVs were consistently larger for speculated nodules. In general, the dependence of structural features on mAs (noise) was low. Conclusion: The FDA phantom CT database may be used for benchmarking of structural features for various scanners and scanning conditions; we used only a small fraction of available data. Our feature convexity outperformed other structural features including RECIST measures.

60 APPLIED LIFE SCIENCES↗

MO-E-12A-01: Quantitative Imaging: Techniques, Applications, and Challenges

The first symposium in the Quantitative Imaging Track focused on the introduction of quantitative imaging (QI) by illustrating the potential of QI in diagnostic and therapeutic applications in research and patient care, highlighting key challenges in implementation of such QI applications, and reviewing QI efforts of selected national and international agencies and organizations, including the FDA, NCI, NIST, and RSNA. This second QI symposium will focus more specifically on the techniques, applications, and challenges of QI. The first talk of the session will focus on modalityagnostic challenges of QI, beginning with challenges of the development and implementation of QI applications in single-center, single-vendor settings and progressing to the challenges encountered in the most general setting of multi-center, multi-vendor settings. The subsequent three talks will focus on specific QI challenges and opportunities in the modalityspecific settings of CT, PET/CT, and MR. Each talk will provide information on modality-specific QI techniques, applications, and challenges, including current efforts focused on solutions to such challenges. Learning Objectives: Understand key general challenges of QI application development and implementation, regardless of modality. Understand selected QI techniques and applications in CT, PET/CT, and MR. Understand challenges, and potential solutions for such challenges, for the applications presented for each modality.

60 APPLIED LIFE SCIENCES↗

MO-G-17A-08: Applications of Quantitative PET/CT Imaging of Yttrium-90: A Tool for Improving Radioembolization

Purpose: Yttrium-90 (Y90) PET/CT post-treatment imaging of radioembolization has fostered significant interest from both the interventional radiology and nuclear medicine communities over the past few years. Recent literature has demonstrated high quantitative accuracy of Y90 PET at the activity concentrations common in radioembolization. However, few have explored methods in which this information can be clinically applied toward improving patient care. Methods: IRB approval and informed consent was obtained for over 35 Y90 post-treatment imaging studies, performed under 2 distinct protocols. In protocol 1, Y90 PET/CT provided quantitative post-treatment imaging, which was then converted into 3D maps of absorbed-dose. Both images and absorbed dose maps were used to manage patient care. In protocol 2, tumor absorbed-dose measurements from Y90 PET/CT were compared to known tumoricidal thresholds. If insufficient absorbed dose was delivered to the tumor, the patient would have an additional Y90 infusion the same day, providing truly patient-specific Y90 PET/CT based treatment-planning. Results: Y90 PET/CT allowed for a superior post-radioembolization evaluation of technical success compared with conventional Y90 bremsstrahlung SPECT. Due to the exceptional resolution of PET, a direct comparison between the distribution of radioembolization and pre-treatment planning intentions can be made. Further, quantification of tumor absorbed-dose directly from PET/CT imaging allows for the prediction of treatment efficacy based on a comparison with known tumoricidal thresholds. This immediate evaluation allowed treating physicians to consider additional or alternate therapies before discovering clinical failure weeks later. One protocol 2 patient was found to have a subtumoricidal absorbed dose following radioembolization. This patient received a same-day infusion of additional Y90 with identical catheter placement to the first infusion. A robust treatment response was seen on follow-up imaging. Conclusion: Y90 PET/CT produces quantifiable image sets, which can be transformed into 3D maps of absorbed dose. This information can be utilized to improve patient care. SIRTeX Medical, Surefire Medical.

60 APPLIED LIFE SCIENCES↗

MO-G-12A-01: Quantitative Imaging Metrology: What Should Be Assessed and How?

The first two symposia in the Quantitative Imaging Track focused on 1) the introduction of quantitative imaging (QI) challenges and opportunities, and QI efforts of agencies and organizations such as the RSNA, NCI, FDA, and NIST, and 2) the techniques, applications, and challenges of QI, with specific examples from CT, PET/CT, and MR. This third symposium in the QI Track will focus on metrology and its importance in successfully advancing the QI field. While the specific focus will be on QI, many of the concepts presented are more broadly applicable to many areas of medical physics research and applications. As such, the topics discussed should be of interest to medical physicists involved in imaging as well as therapy. The first talk of the session will focus on the introduction to metrology and why it is critically important in QI. The second talk will focus on appropriate methods for technical performance assessment. The third talk will address statistically valid methods for algorithm comparison, a common problem not only in QI but also in other areas of medical physics. The final talk in the session will address strategies for publication of results that will allow statistically valid meta-analyses, which is critical for combining results of individual studies with typically small sample sizes in a manner that can best inform decisions and advance the field. Learning Objectives: Understand the importance of metrology in the QI efforts. Understand appropriate methods for technical performance assessment. Understand methods for comparing algorithms with or without reference data (i.e., “ground truth”). Understand the challenges and importance of reporting results in a manner that allows for statistically valid meta-analyses.

60 APPLIED LIFE SCIENCES↗