Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative phase imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A Comparison of Amplitude-Based and Phase-Based Positron Emission Tomography Gating Algorithms for Segmentation of Internal Target Volumes of Tumors Subject to Respiratory Motion

Purpose: To quantitatively compare the accuracy of tumor volume segmentation in amplitude-based and phase-based respiratory gating algorithms in respiratory-correlated positron emission tomography (PET). Methods and Materials: List-mode fluorodeoxyglucose-PET data was acquired for 10 patients with a total of 12 fluorodeoxyglucose-avid tumors and 9 lymph nodes. Additionally, a phantom experiment was performed in which 4 plastic butyrate spheres with inner diameters ranging from 1 to 4 cm were imaged as they underwent 1-dimensional motion based on 2 measured patient breathing trajectories. PET list-mode data were gated into 8 bins using 2 amplitude-based (equal amplitude bins [A1] and equal counts per bin [A2]) and 2 temporal phase-based gating algorithms. Gated images were segmented using a commercially available gradient-based technique and a fixed 40% threshold of maximum uptake. Internal target volumes (ITVs) were generated by taking the union of all 8 contours per gated image. Segmented phantom ITVs were compared with their respective ground-truth ITVs, defined as the volume subtended by the tumor model positions covering 99% of breathing amplitude. Superior-inferior distances between sphere centroids in the end-inhale and end-exhale phases were also calculated. Results: Tumor ITVs from amplitude-based methods were significantly larger than those from temporal-based techniques (P=.002). For lymph nodes, A2 resulted in ITVs that were significantly larger than either of the temporal-based techniques (P<.0323). A1 produced the largest and most accurate ITVs for spheres with diameters of ≥2 cm (P=.002). No significant difference was shown between algorithms in the 1-cm sphere data set. For phantom spheres, amplitude-based methods recovered an average of 9.5% more motion displacement than temporal-based methods under regular breathing conditions and an average of 45.7% more in the presence of baseline drift (P<.001). Conclusions: Target volumes in images generated from amplitude-based gating are larger and more accurate, at levels that are potentially clinically significant, compared with those from temporal phase-based gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Capturing the crystalline phase of two-dimensional nanocrystal superlattices in action.

Critical photonic, electronic, and magnetic applications of two-dimensional nanocrystal superlattices often require nanostructures in perfect single-crystal phases with long-range order and limited defects. Here we discovered a crystalline phase with quasi-long-range positional order for two-dimensional nanocrystal superlattice domains self-assembled at the liquid-air interface during droplet evaporation, using in situ time-resolved X-ray scattering along with rigorous theories on two dimensional crystal structures. Surprisingly, it was observed that drying these superlattice domains preserved only an orientational order but not a long-range positional order, also supported by quantitative analysis of transmission electron microscopy images.

36 MATERIALS SCIENCE↗

Creating ground truth for nanocrystal morphology: a fully automated pipeline for unbiased transmission electron microscopy analysis

Control over colloidal nanocrystal morphology (size, size distribution, and shape) is important for tailoring the functionality of individual nanocrystals and their ensemble behavior. Despite this, traditional methods to quantify nanocrystal morphology are laborious. New developments in automated morphology classification will accelerate these analyses but the assessment of machine learning models is limited by human accuracy for ground truth, causing even unsupervised machine learning models to have inherent bias. Herein, we introduce synthetic image rendering to solve the ground truth problem of nanocrystal morphology classification. By simulating 2D images of nanocrystal shapes via a function of high-dimensional parameter space, we trained a convolutional neural network to link unique morphologies to their simulated parameters, defining nanocrystal morphology quantitatively rather than qualitatively. An automated pipeline then processes, quantitatively defines, and classifies nanocrystal morphology from experimental transmission electron microscopy (TEM) images. Using improved computer vision techniques, 42,650 nanocrystals were identified, assessed, and labeled with quantitative parameters, offering a 600-fold improvement in efficiency over best-practice manual measurements. Further, a classification algorithm was trained with a prediction accuracy of 99.5%, which can successfully analyze a range of concave, convex, and irregular nanocrystal shapes. The resulting pipeline was applied to differentiating two syntheses of nominally cuboidal CsPbBr 3 nanocrystals and uniquely classifying binary nickel sulfide nanocrystal phase based on morphology. This pipeline provides a simple, efficient, and unbiased method to quantify nanocrystal morphology and represents a practical route to construct large datasets with an absolute ground truth for training unbiased morphology-based machine learning algorithms.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Semiautomatic method to identify the best phase for gated RT in lung region by 4D-PET/CT acquisitions

Purpose: Delineating tumor motion by four-dimensional positron emission tomography/computed tomography (4D-PET/CT) is a crucial step for gated radiotherapy (RT). This article quantitatively evaluates semiautomatic algorithms for tumor shift estimation in the lung region due to patient respiration by 4D-PET/CT, in order to support the selection of the best phases for gated RT, by considering the most stable phases of the breathing cycle. Methods: Three mobile spheres and ten selected lesions were included in this study. 4D-PET/CT data were reconstructed and classified into six/ten phases. The semiautomatic algorithms required the generation of single sets of images representative of the full target motion, used as masks for segmenting the phases. For 4D-CT, a pre-established HU range was used, whereas three thresholds (100%, 80%, and 40%) were evaluated for 4D-PET. By using these segmentations, the authors estimated the lesion motion from the shifting centroids, and the phases with the least motion were also deduced including the phases with a curve slope less than 2 mm/{Delta}phase. The proposed algorithms were validated by comparing the results to those generated entirely by manual contouring. Results: In the phantom study, the mean difference between the manual contour and the semiautomatic technique was 0.1{+-}0.1 mm for 4D-CT and 0.2{+-}0.1 mm for the 4D-PET based on 40% threshold. In the patients' series, the mean difference was 0.9{+-}0.6 mm for 4D-CT and 0.8{+-}0.2 mm for the 4D-PET based on 40% threshold. Conclusions: Estimation of lesion motion by the proposed semiautomatic algorithm can be used to evaluate tumor motion due to breathing.

60 APPLIED LIFE SCIENCES↗

Step Bunch Evolution on Vicinal Faces of KDP

For in-situ studies of the formation and evolution of step patterns in solution growth, we have assembled an experimental setup based on Michelson interferometry with the growing crystal surface as one of the reflective surfaces. The device allows data collection over a relatively large area (approximately 4 sq. mm) in situ and in real time during growth. The depth resolution is improved over traditional interferometry using phase-shifted images combining by a suitable algorithm. We achieve a depth resolution of approximately 50 Angstroms. Lateral resolution, dependent on the degree of magnification, is around 0.3 to 5 microns. The crystal chosen as a model in this work is potassium dihydrogen phosphate (KDP), the optically non-linear material widely used in frequency doubling applications. Kinetics of KDP crystallization is well studied so that KDP can serve as a benchmark for our investigations. We present quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, flow rate, and flow direction. The kinetics data suggest that at low supersaturations, step bunching is caused by impurity retardation of the steps, while at higher supersaturations, we link the non-linearity during growth to interdependence of the velocity and density of the steps evidenced in independent experiments. The behavior on the surface is very dynamic, small bunches both merge and split from larger bunches as they travel across the facet. We present evidence that despite these dynamics, under steady conditions there exists a limiting value to step bunch height. This height is reached at distances between 600 and 1000 microns from the step source. In our experiments, we observed the retention of this step bunch height limit up to the path of 1500 microns.

Booth, N. A.↗

Experimental investigation of bubbling in particle beds with high solid holdup

A series of experiments on bubbling behavior in particle beds was performed to clarify three-phase flow dynamics in debris beds formed after core-disruptive accident (CDA) in sodium-cooled fast breeder reactors (FBRs). Although in the past, several experiments have been performed in packed beds to investigate flow patterns, most of these were under comparatively higher gas flow rate, which may be not expected during an early sodium boiling period in debris beds. The current experiments were conducted under two dimensional (2D) and three dimensional (3D) conditions separately, in which water was used as liquid phase, and bubbles were generated by injecting nitrogen gas from the bottom of the viewing tank. Various particle-bed parameters were varied, including particle-bed height (from 30 mm to 200 mm), particle diameter (from 0.4 mm to 6 mm) and particle type (beads made of acrylic, glass, alumina and zirconia). Under these experimental conditions, three kinds of bubbling behavior were observed for the first time using digital image analysis methods that were further verified by quantitative detailed analysis of bubbling properties including surface bubbling frequency and surface bubble size under both 2D and 3D conditions. This investigation, which hopefully provides fundamental data for a better understanding and an improved estimation of CDAs in FBRs, is expected to benefit future analysis and verification of computer models developed in advanced fast reactor safety analysis codes. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Single-shot carrier-envelope-phase-tagged ion-momentum imaging of nonsequential double ionization of argon in intense 4-fs laser fields

Single-shot carrier-envelope-phase (CEP) tagging is combined with a reaction mircoscope (REMI) to investigate CEP-dependent processes in atoms. Excellent experimental stability and data acquisition longevity are achieved. Using this approach, we study the CEP effects for nonsequential double ionization of argon in 4-fs laser fields at 750 nm and an intensity of 1.6x10{sup 14} W/cm{sup 2}. The Ar{sup 2+} ionization yield shows a pronounced CEP dependence which compares well with recent theoretical predictions employing quantitative rescattering theory [S. Micheau et al., Phys. Rev. A 79, 013417 (2009)]. Furthermore, we find strong CEP influences on the Ar{sup 2+} momentum spectra along the laser polarization axis.

74 ATOMIC AND MOLECULAR PHYSICS↗

Machine Vision for Relative Spacecraft Navigation During Approach to Docking

This paper describes a machine vision system for relative spacecraft navigation during the terminal phase of approach to docking that: 1) matches high contrast image features of the target vehicle, as seen by a camera that is bore-sighted to the docking adapter on the chase vehicle, to the corresponding features in a 3d model of the docking adapter on the target vehicle and 2) is robust to on-orbit lighting. An implementation is provided for the case of the Space Shuttle Orbiter docking to the International Space Station (ISS) with quantitative test results using a full scale, medium fidelity mock-up of the ISS docking adapter mounted on a 6-DOF motion platform at the NASA Marshall Spaceflight Center Flight Robotics Laboratory and qualitative test results using recorded video from the Orbiter Docking System Camera (ODSC) during multiple orbiter to ISS docking missions. The Natural Feature Image Registration (NFIR) system consists of two modules: 1) Tracking which tracks the target object from image to image and estimates the position and orientation (pose) of the docking camera relative to the target object and 2) Acquisition which recognizes the target object if it is in the docking camera Field-of-View and provides an approximate pose that is used to initialize tracking. Detected image edges are matched to the 3d model edges whose predicted location, based on the pose estimate and its first time derivative from the previous frame, is closest to the detected edge1 . Mismatches are eliminated using a rigid motion constraint. The remaining 2d image to 3d model matches are used to make a least squares estimate of the change in relative pose from the previous image to the current image. The changes in position and in attitude are used as data for two Kalman filters whose outputs are smoothed estimate of position and velocity plus attitude and attitude rate that are then used to predict the location of the 3d model features in the next image.

Chien, Chiun-Hong↗

A fine pore-preserved deep neural network for porosity analytics of a high burnup U-10Zr metallic fuel

Abstract U-10 wt.% Zr (U-10Zr) metallic fuel is the leading candidate for next-generation sodium-cooled fast reactors. Porosity is one of the most important factors that impacts the performance of U-10Zr metallic fuel. The pores generated by the fission gas accumulation can lead to changes in thermal conductivity, fuel swelling, Fuel-Cladding Chemical Interaction (FCCI) and Fuel-Cladding Mechanical Interaction (FCMI). Therefore, it is crucial to accurately segment and analyze porosity to understand the U-10Zr fuel system to design future fast reactors. To address the above issues, we introduce a workflow to process and analyze multi-source Scanning Electron Microscope (SEM) image data. Moreover, an encoder-decoder-based, deep fully convolutional network is proposed to segment pores accurately by integrating the residual unit and the densely-connected units. Two SEM 250 × field of view image datasets with different formats are utilized to evaluate the new proposed model’s performance. Sufficient comparison results demonstrate that our method quantitatively outperforms two popular deep fully convolutional networks. Furthermore, we conducted experiments on the third SEM 2500 × field of view image dataset, and the transfer learning results show the potential capability to transfer the knowledge from low-magnification images to high-magnification images. Finally, we use a pre-trained network to predict the pores of SEM images in the whole cross-sectional image and obtain quantitative porosity analysis. Our findings will guide the SEM microscopy data collection efficiently, provide a mechanistic understanding of the U-10Zr fuel system and bridge the gap between advanced characterization to fuel system design.

36 MATERIALS SCIENCE↗

The effect of loading direction on the fracture behaviors of cortical bone at a dynamic loading rate

Here, the dynamic cracking processes in porcine cortical bone were visualized in real-time using the high-speed synchrotron X-ray phase-contrast imaging (PCI) technique in three osteon orientations: in-plane transverse, out-of-plane transverse and in-plane longitudinal. The dynamic flexural loading applied on the pre-notched bone specimens was introduced by a modified Kolsky compression bar. High-speed X-ray images of the entire loading events were documented with a high-speed camera. Three-dimensional X-ray micro-computed tomography was conducted to examine the intact microstructures and obtain the basic material properties of the bone material used for mechanical characterizations. The onset location, where crack initiated, and the subsequent direction, along which the incipient crack propagated, were measured quantitatively using the high-speed X-ray images and the latter was found dependent on the osteon direction significantly. The crack propagation velocities were dependent on crack extension over the entire crack path significantly for all the three directions while the initial velocity for in-plane longitudinal direction was lower than the other two directions. Straight-through crack paths were observed for in-plane longitudinal specimens while the cracks were deflected and twisted in the in-plane transverse direction. For out-of-plane transverse direction, the cracks follow paths with tortuosity fall in between the other two directions, showing a mixed mode of fractures of the former two extreme cases. The toughening mechanisms, visualized by the high-speed X-ray images, and the corresponding fracture toughness, evaluated in terms of fracture initiation toughness and crack growth resistance curve (R-curve), were also found significantly different among the three osteon directions, suggesting an overall transition from brittle to ductile-like fracture behaviors at the dynamic displacement rate (5.4 m/s) as the osteon orientation varies from in-plane longitudinal to out-of-plane transverse, and to in-plane transverse eventually.

42 ENGINEERING↗

In Situ Synchrotron X-ray Study of Ultrasound Cavitation and Its Effect on Solidification Microstructures

Considerable progress has been made in studying the mechanism and effectiveness of using ultrasound waves to manipulate the solidification microstructures of metallic alloys. However, uncertainties remain in both the underlying physics of how microstructures evolve under ultrasonic waves, and the best technological approach to control the final microstructures and properties. We used the ultrafast synchrotron X-ray phase contrast imaging facility housed at the Advanced Photon Source, Argonne National Laboratory, US to study in situ the highly transient and dynamic interactions between the liquid metal and ultrasonic waves/bubbles. The dynamics of ultrasonic bubbles in liquid metal and their interactions with the solidifying phases in a transparent alloy were captured in situ. The experiments were complemented by the simulations of the acoustic pressure field, the pulsing of the bubbles, and the associated forces acting onto the solidifying dendrites. The study provides more quantitative understanding on how ultrasonic waves/bubbles influence the growth of dendritic grains and promote the grain multiplication effect for grain refinement.

36 MATERIALS SCIENCE↗

A Phase Locked High Speed Real-Time Interferometry System for Large Amplitude Unsteady Flows

A high speed phase locked interferometry system has been designed and developed for real-time measurements of the dynamic stall flow over a pitching airfoil. Point diffraction interferograms of incipient flow separation over a sinusoidally oscillating airfoil have been obtained at rates of up to 20 KHz and for free stream Mach numbers of 0.3 and 0.45. The images were recorded on ASA 125 and ASA 400 film using a drum camera. Special electronic timing and synchronizing circuits were developed to trigger the laser light source from the camera, and to initiate acquisition of the interferogram sequence from any desired phase angle of oscillation. The airfoil instantaneous angle of attack data provided by an optical encoder was recorded via a FIFO and in EPROM into a microcomputer. The interferograms have been analyzed using software developed in-house to get quantitative flow density and pressure distributions.

Chandrasekhara, M. S.↗

Evaluation of 134 Ce/ 134 La as a PET Imaging Theranostic Pair for 225 Ac α-Radiotherapeutics

225 Ac-targeted α-radiotherapy is a promising approach to treating malignancies, including prostate cancer. However, α-emitting isotopes are difficult to image because of low administered activities and a low fraction of suitable γ-emissions. The in vivo generator 134 Ce/ 134 La has been proposed as a potential PET imaging surrogate for the therapeutic nuclides 225 Ac and 227 Th. In this report, we detail efficient radiolabeling methods using the 225 Ac-chelators DOTA and MACROPA. These methods were applied to radiolabeling of prostate cancer imaging agents, including PSMA-617 and MACROPA-PEG 4 -YS5, for evaluation of their in vivo pharmacokinetic characteristics and comparison to the corresponding 225 Ac analogs. Methods: Radiolabeling was performed by mixing DOTA/MACROPA chelates with 134 Ce/ 134 La in NH 4 OAc, pH 8.0, at room temperature, and radiochemical yields were monitored by radio–thin-layer chromatography. In vivo biodistributions of 134 Ce-DOTA/MACROPA.NH 2 complexes were assayed through dynamic small-animal PET/CT imaging and ex vivo biodistribution studies over 1 h in healthy C57BL/6 mice, compared with free 134 CeCl 3 . In vivo, preclinical imaging of 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5 was performed on 22Rv1 tumor–bearing male nu/nu-mice. Ex vivo biodistribution was performed for 134 Ce/ 225 Ac-MACROPA-PEG 4 -YS5 conjugates. Results: 134 Ce-MACROPA.NH 2 demonstrated near-quantitative labeling with 1:1 ligand-to-metal ratios at room temperature, whereas a 10:1 ligand-to-metal ratio and elevated temperatures were required for DOTA. Rapid urinary excretion and low liver and bone uptake were seen for 134 Ce/ 225 Ac-DOTA/MACROPA. NH 2 conjugates in comparison to free 134 CeCl 3 confirmed high in vivo stability. An interesting observation during the radiolabeling of tumor-targeting vectors PSMA-617 and MACROPA-PEG 4 -YS5—that the daughter 134 La was expelled from the chelate after the decay of parent 134 Ce—was confirmed through radio–thin-layer chromatography and reverse-phase high-performance liquid chromatography. Both conjugates, 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5, displayed tumor uptake in 22Rv1 tumor–bearing mice. The ex vivo biodistribution of 134 Ce-MACROPA.NH 2 , 134 Ce-DOTA and 134 Ce-MACROPA-PEG 4 -YS5 corroborated well with the respective 225 Ac-conjugates. Conclusion: These results demonstrate the PET imaging potential for 134 Ce/ 134 La-labeled small-molecule and antibody agents. The similar 225 Ac and 134 Ce/ 134 La-chemical and pharmacokinetic characteristics suggest that the 134 Ce/ 134 La pair may act as a PET imaging surrogate for 225 Ac-based radioligand therapies.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-172: A Quantitative Assessment of Lung Tumor Motion Using 4DCT Imaging Under Conditions of Controlled Breathing in the Management of Non-Small Cell Lung Cancer (NSCLC) Using Stereotactic Body Radiation Therapy (SBRT)

Purpose: To study breathing related tumor motion amplitudes by lung lobe location under controlled breathing conditions used in Stereotactic Body Radiation Therapy (SBRT) for NSCLC. Methods: Sixty-five NSCLC SBRT patients since 2009 were investigated. Patients were categorized based on tumor anatomic location (RUL-17, RML-7, RLL-18, LUL-14, LLL-9). A 16-slice CT scanner [GE RT16 Pro] along with Varian Realtime Position Management (RPM) software was used to acquire the 4DCT data set using 1.25 mm slice width. Images were binned in 10 phases, T00 being at maximum inspiration ' T50 at maximum expiration phase. Tumor volume was segmented in T50 using the CT-lung window and its displacement were measured from phase to phase in all three axes; superiorinferior, anterior-posterior ' medial-lateral at the centroid level of the tumor. Results: The median tumor movement in each lobe was as follows: RUL= 3.8±2.0 mm (mean ITV: 9.5 cm{sup 3}), RML= 4.7±2.8 mm (mean ITV: 9.2 cm{sup 3}), RLL=6.6±2.6 mm (mean ITV: 12.3 cm{sup 3}), LUL=3.8±2.4 mm (mean ITV: 18.5 cm{sup 3}), ' LLL=4.7±2.5 mm (mean ITV: 11.9 cm{sup 3}). The median respiratory cycle for all patients was found to be 3.81 ± 1.08 seconds [minimum 2.50 seconds, maximum 7.07 seconds]. The tumor mobility incorporating breathing cycle was RUL = 0.95±0.49 mm/s, RML = 1.35±0.62 mm/s, RLL = 1.83±0.71 mm/s, LUL = 0.98 ±0.50 mm/s, and LLL = 1.15 ±0.53 mm/s. Conclusion: Our results show that tumor displacement is location dependent. The range of motion and mobility increases as the location of the tumor nears the diaphragm. Under abdominal compression, the magnitude of tumor motion is reduced by as much as a factor of 2 in comparison to reported tumor magnitudes under conventional free breathing conditions. This study demonstrates the utility of abdominal compression in reducing the tumor motion leading to reduced ITV and planning tumor volumes (PTV)

60 APPLIED LIFE SCIENCES↗

Application of ECH to the study of transport in ITER baseline scenario-like discharges in DIII-D

Recent DIII-D experiments in the ITER Baseline Scenario (IBS) have shown strong increases in fluctuations and correlated reduction of confinement associated with entering the electron-heating-dominated regime with strong electron cyclotron heating (ECH). The addition of 3.2 MW of 110 GHz EC power deposited at ρ~0.42 to IBS discharges with ~3 MW of neutral beam injection causes large increases in low-k and medium-k turbulent density fluctuations observed with Doppler backscatter (DBS), beam emission spectroscopy (BES) and phase-contrast imaging (PCI) diagnostics, correlated with decreases in the energy, particle, and momentum confinement times. Power balance calculations show the electron heat diffusivity χ e increases significantly in the mid-radius region 0.4<ρ<0.8, which is roughly the same region where the DBS and BES diagnostics show the increases in turbulent density fluctuations. Confinement of angular momentum is also reduced during ECH. Studies with the TGYRO transport solver show that the model of turbulent transport embodied in the TGLF code quantitatively reproduces the measured transport in both the neutral beam (NB)-only and in the NB plus EC cases. A simple model of the decrease in toroidal rotation with EC power is set forth, which exhibits a bifurcation in the rotational state of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying the thermal effect and methyl radical production in nanosecond repetitively pulsed glow discharges applied to a methane-air flame

In this work, we investigated non-equilibrium plasma produced by nanosecond repetitively pulsed glow discharges applied across a lean premixed methane-air flame. The flame is stationary, axisymmetric, and laminar. The discharges are applied on the symmetry axis crossing the reactant gases, flame front, and product gases, allowing phase-locked averaged measurements and comparisons with axisymmetric numerical simulations. The thermal effect and methyl radical production are quantified in the discharge in the reactant gas region. One-dimensional, two-beam, hybrid, femtosecond-picosecond, coherent anti-Stokes Raman scattering is used to acquire spatial and temporal profiles of temperature and oxygen-to-nitrogen concentration ratio. Photo-fragmentation laser-induced fluorescence is used to acquire quantitative two-dimensional profiles of methyl radicals in the discharge providing the first quantitative imaging of methyl produced ahead of a flame by plasma-induced methane dissociation. The spatial profiles of temperature and oxygen-to-nitrogen concentration ratio are in steady state, indicating that individual discharges have an insignificant heating effect. Upper and lower bounds of the produced mole fraction of methyl radicals in the plasma are obtained due to uncertainties in the collisional quenching rates of excited state methylidyne radicals in the plasma. The discharges produce a maximum of 600–1100 ppm of methyl radicals upstream of the flame front within 25 ns. This amount is similar to the predicted methyl mole fraction for the flame without plasma and thus represents a significant chemical perturbation to the reactants upstream of the flame front. The produced methyl follows an exponential decay in the first microsecond after the discharge with a decay constant of 8 µs close to the flame, and 0.8 µs further from the flame. The decay then deviates from the exponential curve and the methyl persists for tens of microseconds. The results suggest that for the tested configuration, the thermal effect of individual discharges through fast gas heating is negligible, while active chemical species are produced in large quantities in the reactant gases, upstream of the flame front.

hybrid fs-ps CARS↗