Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Physical and psychophysical characterization of a novel clinical system for digital mammography

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light. In these detectors the readout is usually achieved through arrays of thin film transistors (TFTs). However, TFT readout tends to display noise characteristics worse than those from indirect detectors. To address this problem, a novel clinical system for digital mammography has been recently marketed based on direct-conversion detector and optical readout. This unit, named AMULET and manufactured by FUJIFILM, is based on a dual layer of amorphous selenium that acts both as a converter of x rays (first layer) and as an optical switch for the readout of signals (second layer) powered by a line light source. The optical readout is expected to improve the noise characteristics of the detector. The aim is to obtain images with high resolution and low noise, thanks to the combination of optical switching technology and direct conversion with amorphous selenium. In this article, the authors present a characterization of an AMULET system. Methods: The characterization was achieved in terms of physical figures as modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and contrast-detail analysis. The clinical unit was tested by exposing it to two different beams: 28 kV Mo/Mo (namely, RQA-M2) and 28 kV W/Rh (namely, W/Rh). Results: MTF values of the system are slightly worse than those recorded from other direct-conversion flat panels but still within the range of those from indirect flat panels: The MTF values of the AMULET system are about 45% and 15% at 5 and 8 lp/mm, respectively. On the other hand, however, AMULET NNPS results are consistently better than those from direct-conversion flat panels (up to two to three times lower) and flat panels based on scintillation phosphors. DQE results lie around 70% when RQA-M2 beams are used and approaches 80% in the case of W/Rh beams. Contrast-detail analysis, when performed by human observers on the AMULET system, results in values better than those published for other full-field digital mammography systems. Conclusions: The novel clinical unit based on direct-conversion detector and optical reading presents great results in terms of both physical and psychophysical characterizations. The good spatial resolution, combined with excellent noise properties, allows the achievement of very good DQE, better than those published for clinical FFDM systems. The psychophysical analysis confirms the excellent behavior of the AMULET unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a clinical unit for digital radiography based on irradiation side sampling technology

Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). For both scintillation screens the authors accomplished the measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.Results: At the Nyquist frequency (3.33 lp/mm) the MTF is about 35% and 25% for CsI and GOS detectors, respectively. The CsI scintillator has better noise properties than the GOS screen in almost all the conditions. This is particularly true for low-energy beams, where the noise for the GOS system can go up to a factor 2 greater than that found for CsI. The DQE of the CsI detector reaches a peak of 60%, 60%, 58%, and 50% for the RQA3, RQA5, RQA7, and RQA9 beams, respectively, whereas for the GOS screen the maximum DQE is 40%, 44%, 44%, and 35%. The contrast-detail analysis confirms that in the majority of cases the CsI scintillator is able to provide improved outcomes to those obtained with the GOS screen.Conclusions: The limited diffusion of light produced by the ISS reading makes possible the achievement of very good spatial resolution. In fact, the MTF of the unit with the CsI panel is only slightly lower to that achieved with direct conversion detectors. The combination of very good spatial resolution, together with the good noise properties reached with the CsI screen, allows achieving DQE on average about 1.5 times greater than that obtained with GOS. In fact, the DQE of unit equipped with CsI is comparable to the best alternative methods available which are based on the same technology, and similar to others based on an a-Se direct conversion detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging

Purpose: High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.

60 APPLIED LIFE SCIENCES↗

Bifacial Photovoltaic Module Degradation Dynamics

In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.

bifacial↗

Communication: Engineered tunable decay rate and controllable dissipative dynamics

We investigate the steering dissipative dynamics of a two-level system (qubit) by means of the modulation of an assisted tunneling degree of freedom which is described by a quantum-oscillator spin-boson model. Our results reveal that the decoherence rate of the qubit can be significantly suppressed and simultaneously its quality factor is enhanced. Moreover, the modulated dynamical susceptibility exhibits a multi-peak feature which is indicative of the underlying structure and measurable in experiment. Our findings demonstrate that the interplay between the combined degrees of freedom and the qubit is crucial for reducing the dissipation of qubit and expanding the coherent regime of quantum operation much large. The strategy might be used to fight against deterioration of quantum coherence in quantum information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of 'Resonant' lattices for synchrotrons with negative momentum compaction factor

In synchrotrons the transition energy W{sub tr}=m{sub 0}c{sup 2}({gamma}{sub tr}-1) is fundamentally important because it determines the maximum attainable accelerated currents. From this point of view it is desirable that the momentum compaction factor {alpha} = 1/{gamma}{sub tr}{sup 2} as small as possible or even negative, which makes {gamma}{sub tr} imaginary and accordingly rules out transition energy crossing by particles under acceleration. In this connection a theory of 'resonant' lattices with negative momentum compaction factor based on the correlation principle of simultaneous superperiodic modulation of the orbit curvature and lens gradient functions is worked out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive decoy-state quantum key distribution with practical light sources

Decoy states have been proven to be a very useful method for significantly enhancing the performance of quantum key distribution systems with practical light sources. Although active modulation of the intensity of the laser pulses is an effective way of preparing decoy states in principle, in practice passive preparation might be desirable in some scenarios. Typical passive schemes involve parametric down-conversion. More recently, it has been shown that phase-randomized weak coherent pulses (WCP) can also be used for the same purpose [M. Curty et al., Opt. Lett. 34, 3238 (2009).] This proposal requires only linear optics together with a simple threshold photon detector, which shows the practical feasibility of the method. Most importantly, the resulting secret key rate is comparable to the one delivered by an active decoy-state setup with an infinite number of decoy settings. In this article we extend these results, now showing specifically the analysis for other practical scenarios with different light sources and photodetectors. In particular, we consider sources emitting thermal states, phase-randomized WCP, and strong coherent light in combination with several types of photodetectors, like, for instance, threshold photon detectors, photon number resolving detectors, and classical photodetectors. Our analysis includes as well the effect that detection inefficiencies and noise in the form of dark counts shown by current threshold detectors might have on the final secret key rate. Moreover, we provide estimations on the effects that statistical fluctuations due to a finite data size can have in practical implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Excitation of coherent oscillations in a noisy medium

We numerically study the influence of neuronal threshold modulation on the properties of cortical traveling waves. For that reason we simplify a Wilson-Cowan-type integrodifferential equation model of propagating neocortical activity to a spatially discrete version. Further we introduce a noisy threshold. Depending on the noise level we find different states of the network activity, ranging from asynchronous oscillations, traveling waves, to synchronous oscillations. Finally, we induce the transition between these different states by an external modulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum process tomography of a Mølmer-Sørensen gate via a global beam

Here, we present a framework for quantum process tomography of two-ion interactions that leverages modulations of the trapping potential and composite pulses from a global laser beam to achieve individual-ion addressing. Tomographic analysis of identity and delay processes reveals dominant error contributions from laser decoherence and slow qubit frequency drift during the tomography experiment. We use this framework on two co-trapped 40 Ca + ions to analyze both an optimized and an overpowered Mølmer–Sørensen gate and to compare the results of this analysis to a less informative Bell-state tomography measurement and to predictions based on a simplified noise model. These results show that the technique is effective for the characterization of two-ion quantum processes and for the extraction of meaningful information about the errors present in the system. The experimental convenience of this method will allow for more widespread use of process tomography for characterizing entangling gates in trapped-ion systems.

quantum computing↗

Effects of nuclear structure and quantum interference on diffractive vector meson production in ultra-peripheral nuclear collisions

Here we study diffractive vector meson production in ultra-peripheral collisions (UPCs) of heavy nuclei, utilizing a theoretical framework based on the Color Glass Condensate (CGC) formalism. We focus on Au + Au, U + U, Ru + Ru, Zr + Zr, and Pb + Pb collisions, examining the transverse momentum dependence of vector meson production cross-sections and co s(2ΔΦ)asymmetries in the decay product distributions to explore the role of nuclear geometry. The angular modulation is due to the linear polarization of the incoming photons and quantum interference effects. We extract nuclear radii and find them to be consistent with experimental data from the STAR collaboration. The amplitudes of the cos(2ΔΦ)modulation in the cross-section and the extracted radii depend on the nuclear geometry. This dependence is dominated by the geometry-dependent variation of the minimum impact parameter required for ultra-peripheral collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature-dependent efficiency droop of blue InGaN micro-light emitting diodes

Temperature-dependent trends in radiative and Auger recombination coefficients have been determined at different injection carrier concentrations using InGaN micro-light emitting diodes 40 μm in diameter. The differential lifetime was obtained first from the measured modulation bandwidth and was then employed to calculate the carrier concentration in the quantum well active region. When the temperature increases, the carrier concentration increases, but both the radiative and Auger recombination coefficients decrease. In addition, the temperature dependence of radiative and Auger recombination coefficients is weaker at a higher injection carrier concentration, which is strongly related to phase space filling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Density fluctuations due to Raman forward scattering in quantum plasma

Density fluctuations due Raman forward scattering (RFS) is analysed in the interaction of a high intensity laser pulse with high density quantum plasma. The interaction model is developed using the quantum hydrodynamic (QHD) model which consist of a set of equations describing the transport of charge, density, momentum and energy of a charged particle system interacting through a self-consistent electrostatic potential. The nonlinear source current has been obtained incorporating the effects of quantum Bohm potential, Fermi pressure and electron spin. The laser spectrum is strongly modulated by the interaction, showing sidebands at the plasma frequency. Furthermore, as the quiver velocity of the electrons in the high electric field of the laser beam is quit large, various quantum effects are observed which can be attributed to the variation of electron mass with laser intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency modulation and compression of optical pulses in an optical fibre with a travelling refractive-index wave

We have studied the conditions for spectral broadening, frequency modulation and compression (both temporal and spectral) of Gaussian pulses propagating in a fibre with a travelling refractive-index wave. Analytical expressions have been derived for the dependences of pulse duration, chirp and spectral width on the distance travelled through the fibre, parameters of the fibre and radiation launched into it. Based on the numerical analysis we have studied the behaviour of these characteristics by changing the coefficient of the refractive-index modulation and other parameters of the travelling refractive-index wave. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active 2D materials for on-chip nanophotonics and quantum optics

Two-dimensional materials have emerged as promising candidates to augment existing optical networks for metrology, sensing, and telecommunication, both in the classical and quantum mechanical regimes. Here, we review the development of several on-chip photonic components ranging from electro-optic modulators, photodetectors, bolometers, and light sources that are essential building blocks for a fully integrated nanophotonic and quantum photonic circuit.

2D materials↗

Simulating Dirac fermions with Abelian and non-Abelian gauge fields in optical lattices

In this work we present an optical lattice setup to realize a full Dirac Hamiltonian in 2+1 dimensions. We show how all possible external potentials coupled to the Dirac field can arise from perturbations of the existing couplings of the honeycomb lattice pattern. This greatly simplifies the proposed implementations, requiring only spatial modulations of the intensity of the laser beams to induce complex non-Abelian potentials. We finally suggest several experiments to observe the properties of the quantum field theory in the setup. - Highlights: Black-Right-Pointing-Pointer This work provides a very flexible setup for simulating Dirac fermions. Black-Right-Pointing-Pointer The manuscript contains a detailed study of optical lattice deformations. Black-Right-Pointing-Pointer The link between lattice deformations and effective gauge Hamiltonians is studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interacting dark states with enhanced nonlinearity in an ideal four-level tripod atomic system

We present an experimental system to generate large cross-phase modulation (XPM) in cold rubidium atoms. By using an efficient state-preparation technique in the {sup 87}Rb D1 line, an ideal four-level tripod-type atomic system is formed, which generates large cross-Kerr nonlinearity via interacting dark states in this system. The induced phase shift due to XPM for the probe beam is measured for different trigger beam intensities, which is the key to achieving conditional quantum phase gates and many other applications in quantum information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response to dynamical modulation of the optical lattice for fermions in the Hubbard model

Fermionic atoms in a periodic optical lattice provide a realization of the single-band Hubbard model. Using quantum Monte Carlo simulations along with the maximum-entropy method, we evaluate the effect of a time-dependent perturbative modulation of the optical lattice amplitude on atomic correlations, revealed in the fraction of doubly occupied sites. We find that the effect of modulation depends strongly on the filling--the response of the double occupation is significantly different in the half-filled Mott insulator from that in the doped Fermi liquid region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical Creation of Fractionalized Vortices and Vortex Lattices

We investigate the dynamic creation of fractionalized half-quantum vortices in Bose-Einstein condensates of sodium atoms. Our simulations show that both individual half-quantum vortices and vortex lattices can be created in rotating optical traps when additional pulsed magnetic trapping potentials are applied. We also find that a distinct periodically modulated spin-density-wave spatial structure is always embedded in square half-quantum vortex lattices. This structure can be conveniently probed by taking absorption images of ballistically expanding cold atoms in a Stern-Gerlach field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗