Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

Markham, Brian↗

Prelaunch absolute radiometric calibration of LANDSAT-4 protoflight Thematic Mapper

Results are summarized and analyzed from several prelaunch tests with a 122 cm integrating sphere used as part of the absolute radiometric calibration experiments for the protoflight TM sensor carried on the LANDSAT-4 satellite. The calibration procedure is presented and the radiometric sensitivity of the TM is assessed. The internal calibrator and dynamic range after calibration are considered. Tables show dynamic range after ground processing, spectral radiance to digital number and digital number to spectral radiance values for TM bands 1, 2, 3, 4, 5, 7 and for channel 4 of band 6.

Barker, J. L.↗

Ocean Color Optical Property Data Derived from OCTS and POLDER: A Comparison Study

We describe our efforts in studying and comparing the ocean color data derived from the Japanese Ocean Color and Temperature Scanner (OCTS) and the French Polarization and Directionality of the Earth's Reflectances (POLDER). OCTS and POLDER were both on board Japan's Sun-synchronous Advanced Earth Observing Satellite (ADEOS-1) from August 1996 to June 1997, collecting about 10 months of global ocean color data. This provides a unique opportunity for developing methods and strategies for the merging of ocean color data from multiple ocean color sensors. In this paper, we describe our approach in developing consistent data processing algorithms for both OCTS and POLDER and using a common in situ data set to vicariously calibrate the two sensors. Therefore, the OCTS and POLDER-measured radiances are effectively bridged through common in situ measurements. With this approach in processing data from two different sensors, the only differences in the derived products from OCTS and POLDER are the differences inherited from the instrument characteristics. Results show that there are no obvious bias differences between the OCTS and POLDER-derived ocean color products, whereas the differences due to noise, which stem from variations in sensor characteristics, are difficult to correct. It is possible, however, to reduce noise differences with some data averaging schemes. The ocean color data from OCTS and POLDER can therefore be compared and merged in the sense that there is no significant bias between two.

Wang, Menghua↗

Overview of Terra and Aqua MODIS Status

This presentation will consist of two one-hour lectures. The first lecture will review the characteristics of the MODIS instrument and how it responds to the performance specifications. The pre-launch and on-orbit procedures and results to characterize and maintain instrument output so as to allow the prescribed science to be done will also be outlined. This will include defining the equations used to account for gain changes and any degradation in the optics of the instrument or the on-board calibration devices themselves. The changes in the solar diffuser and the radiance versus scan angle performance of the scan mirror will also be reviewed. Overall it will be shown that the instrument has and is meeting specifications of 2% reflectance relative to the sun, 5% in the radiance observed in the reflected solar radiation bands, and 0.5-1% in the thermal bands. The second lecture will review and describe highlights in the geophysical products and related science results. There are approximately 40 geophysical products related to observations of land, ocean and atmosphere features. Many of the results are unprecedented and offer considerable advances over those achievable with heritage instruments such as the NOAA Advanced Very High Resolution Radiometer (AVHRR). The literature is showing a steady growth of publications in scientific journals using MODIS data or products. The future is also bright in that a follow-on instrument based on the MODIS will be flown on the National Polar-Orbiting Environmental Satellite Series (NPOESS) starting around 2010.

Salomonson, Vincent V.↗

Global Long-Term SeaWiFS Deep Blue Aerosol Products available at NASA GES DISC

Long-term climate data records about aerosols are needed in order to improve understanding of air quality, radiative forcing, and for many other applications. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) provides a global well-calibrated 13- year (1997-2010) record of top-of-atmosphere radiance, suitable for use in retrieval of atmospheric aerosol optical depth (AOD). Recently, global aerosol products derived from SeaWiFS with Deep Blue algorithm (SWDB) have become available for the entire mission, as part of the NASA Making Earth Science data records for Use in Research for Earth Science (MEaSUREs) program. The latest Deep Blue algorithm retrieves aerosol properties not only over bright desert surfaces, but also vegetated surfaces, oceans, and inland water bodies. Comparisons with AERONET observations have shown that the data are suitable for quantitative scientific use [1],[2]. The resolution of Level 2 pixels is 13.5x13.5 km2 at the center of the swath. Level 3 daily and monthly data are composed by using best quality level 2 pixels at resolution of both 0.5ox0.5o and 1.0ox1.0o. Focusing on the southwest Asia region, this presentation shows seasonal variations of AOD, and the result of comparisons of 5-years (2003- 2007) of AOD from SWDB (Version 3) and MODIS Aqua (Version 5.1) for Dark Target (MYD-DT) and Deep Blue (MYD-DB) algorithms.

Shen, Suhung↗

In-Flight Performance of the Ozone Monitoring Instrument

The Dutch-Finnish Ozone Monitoring Instrument (OMI) is an imaging spectrograph flying on NASA's EOS Aura satellite since 15 July 2004. OMI is primarily used to map trace-gas concentrations in the Earth's atmosphere, obtaining mid-resolution (0.4-0.6 nm) ultraviolet-visible (UV- VIS; 264-504 nm) spectra at multiple (30-60) simultaneous fields of view. Assessed via various approaches that include monitoring of radiances from selected ocean, land ice and cloud areas, as well as measurements of line profiles in the solar spectra, the instrument shows low optical degradation and high wavelength stability over the mission lifetime. In the regions relatively free from the slowly unraveling "row anomaly" (RA) the OMI irradiances have degraded by 3- 8 %, while radiances have changed by 1-2 %. The long-term wavelength calibration of the instrument remains stable to 0.005-0.020 nm.

ultraviolet↗

Optical Sensors for Planetary Radiant Energy (OSPREy): Calibration and Validation of Current and Next-Generation NASA Missions

A principal objective of the Optical Sensors for Planetary Radiance Energy (OSPREy) activity is to establish an above-water radiometer system as a lower-cost alternative to existing in-water systems for the collection of ground-truth observations. The goal is to be able to make high-quality measurements satisfying the accuracy requirements for the vicarious calibration and algorithm validation of next-generation satellites that make ocean color and atmospheric measurements. This means the measurements will have a documented uncertainty satisfying the established performance metrics for producing climate-quality data records. The OSPREy approach is based on enhancing commercial-off-the-shelf fixed-wavelength and hyperspectral sensors to create hybridspectral instruments with an improved accuracy and spectral resolution, as well as a dynamic range permitting sea, Sun, sky, and Moon observations. Greater spectral diversity in the ultraviolet (UV) will be exploited to separate the living and nonliving components of marine ecosystems; UV bands will also be used to flag and improve atmospheric correction algorithms in the presence of absorbing aerosols. The short-wave infrared (SWIR) is expected to improve atmospheric correction, because the ocean is radiometrically blacker at these wavelengths. This report describes the development of the sensors, including unique capabilities like three-axis polarimetry; the documented uncertainty will be presented in a subsequent report.

Hooker, Stanford B.↗

Radiometric Assessment of the First Three Years of the NOAA-20 VIIRS Reflective Solar Bands Calibration

NASA’s Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg Ed4.1 product utilizes geostationary (GEO) satellite measured radiances and retrieved cloud properties to account for the regional diurnal fluctuations in the Earth’s radiant broadband fluxes for times between the CERES measurements gathered from the Aqua (1:30 PM) and Terra (10:30 AM) sun-synchronous satellites. In CERES Edition 4 products, a global uniformity in the cloud properties and computed surface fluxes across the GEO satellite domains is maintained by scaling the radiance observations from more than twenty GEO visible imagers in the CERES record to a common radiometric reference scale, i.e., Aqua-MODIS. With the new-generation GEO (Himawari-8/9 and GOES-16/17) imagers having multiple reflective solar bands (RSB) that are spectrally similar to those of VIIRS, the CERES Imager and Geostationary Calibration Group (IGCG) is preparing to use NOAA-20 VIIRS as the reference imager for maintaining the radiometric uniformity across the GEO imager constellation. Given the recent Aqua satellite anomaly, this transition may happen sooner than the projected date of Aqua’s de-orbit. This paper presents an independent performance evaluation of the first three years of the NOAA-20 VIIRS RSB calibration in the NASA VIIRS Land Science Investigator-led Processing System (Land SIPS) L1b Collection 2 dataset. The temporal radiometric stability is assessed using multiple invariant Earth targets, including tropical deep convective clouds and the Saharan desert. The invariant target anisotropic reflectance at the top of atmosphere was modeled using five years of stable satellite observations acquired from the previous VIIRS instrument onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. The anisotropic corrections are essential for detecting temporal trends with a high statistical confidence. In addition, the radiometric consistency between the RSB of the two VIIRS instruments will be evaluated.

Rajendra Bhatt↗

Radiometric Assessment of the First Three Years of the NOAA-20 VIIRS Reflective Solar Bands Calibration

NASA’s Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg Ed4.1 product utilizes geostationary (GEO) satellite measured radiances and retrieved cloud properties to account for the regional diurnal fluctuations in the Earth’s radiant broadband fluxes for times between the CERES measurements gathered from the Aqua (1:30 PM) and Terra (10:30 AM) sun-synchronous satellites. In CERES Edition 4 products, a global uniformity in the cloud properties and computed surface fluxes across the GEO satellite domains is maintained by scaling the radiance observations from more than twenty GEO visible imagers in the CERES record to a common radiometric reference scale, i.e., Aqua-MODIS. With the new-generation GEO (Himawari-8/9 and GOES-16/17) imagers having multiple reflective solar bands (RSB) that are spectrally similar to those of VIIRS, the CERES Imager and Geostationary Calibration Group (IGCG) is preparing to use NOAA-20 VIIRS as the reference imager for maintaining the radiometric uniformity across the GEO imager constellation. Given the recent Aqua satellite anomaly, this transition may happen sooner than the projected date of Aqua’s de-orbit. This paper presents an independent performance evaluation of the first three years of the NOAA-20 VIIRS RSB calibration in the NASA VIIRS Land Science Investigator-led Processing System (Land SIPS) L1b Collection 2 dataset. The temporal radiometric stability is assessed using multiple invariant Earth targets, including tropical deep convective clouds and the Saharan desert. The invariant target anisotropic reflectance at the top of the atmosphere was modeled using five years of stable satellite observations acquired from the previous VIIRS instrument onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. The anisotropic corrections are essential for detecting temporal trends with high statistical confidence. In addition, the radiometric consistency between the RSB of the two VIIRS instruments will be evaluated.

Rajendra Bhatt↗

Consistency in long-term observations of oceans and ice from space

Satellite remote sensing has provided powerful tools for constructing long-term records of observations of many of Earth's geophysical processes. Geophysicists studying climage change would like to construct time series of data which are as long, accurate, and consistent as possible. While technological advances continue to improve the quality of observations from space, they also present consistency problems. The scanning multichannel microwave radiometer (SMMR), which operated from October 1978 to August 1987, and the special sensor microwave imager (SSMI), which overlapped with the SMMR for nearly two months in 1987, have provided microwave radiances which have been used to monitor long-term changes in sea ice concentration and snow accumulation, among other things. Inspection has shown, however, that brightness temperatures from the two sensors over the same polar firn-covered scene can differ by as much as 14 K. Calibration corrections for polar firn have been derived; in this paper, we present calculations addressing the physics of the small frequency and viewing angle differences between the SMMR and the SSMI on microwave emission from polar scenes containing free water. We focus here only on surface emission. We use a surface scattering model and study the effects of surface roughness, snow wetness, snow density, and young sea ice concentration. We also compare data from Antarctica with our modeled results. We find that for most scenes, surface roughness dominates over the effects of frequency and viewing angle differences, but that for open long-term times series, data must be calibrated and constructed at the geophysical product level rather than at the level of measured radiances.

Zabel, I. H. H.↗

Surface and aerosol models for use in radiative transfer codes

Absolute reflectance-based radiometric calibrations of Landsat-5 Thematic Mapper (TM) are improved with the inclusion of a method to invert optical-depth measurements to obtain aerosol-particle size distributions, and a non-Lambertian surface reflectance model. The inverted size distributions can predict radiances varying from the previously assumed jungian distributions by as much as 5 percent, though the reduction in the estimated error is less than one percent. Comparison with measured diffuse-to-global ratios show that neither distribution consistently predicts the ratio accurately, and this is shown to be a large contributor to calibration uncertainties. An empirical model for the surface reflectance of White Sands, using a two-degree polynomial fit as a function of scattering angle, was employed. The model reduced estimated errors in radiance predictions by up to one percent. Satellite calibrations dating from October, 1984 were reprocessed using the improved methods and linear estimations of satellite counts per unit radiance versus time since launch were determined which showed a decrease over time for the first four bands.

Hart, Quinn J.↗

Cirrus cloud statistics: Temperatures and optical depths

Measurements of the upwelling infrared radiance at 10.5 and 6.5 microns were obtained during the FIRE cirrus Intensive Field Observations using a radiometer with a 15 deg cone nadir field-of-view flown on the NASA Ames ER-2. Data are recorded at a frequency of 1 Hz and the radiometer is continuously calibrated with a liquid nitrogen blackbody source, thereby providing a large number of very accurate radiance values during the course of a several hour flight. For this study, the focus is on the statistical properties of the cirrus deck as deduced from the radiance data. The data acquired on 28 October 1986 is stressed, but some data from the other flights are also shown for comparison purposes.

Valero, Francisco P. J.↗

RSP Data Status, Updates and Plans from the Team

•All radiance (L1C), aerosol and cloud (L2) products are in the archive. •Revised calibration performed at GSFC in July 2021 applied to reprocessing. •Clouds have smaller drops and higher optical depths (larger droplet number concentrations) in winter than in summer. Cloud top droplet size distributions tend to be narrow with roughly 80% having an effective variance of less than 0.07. This is relevant to how well bulk auto-conversion parameterizations are likely to work at cloud top (order of magnitude effects) and also to assumptions used in the remote sensing of droplet number (~ 10% effect). Real refractive index and effective radius retrievals are consistent with hygroscopic growth of aerosols Real refractive index and effective variance retrievals imply the presence of an insoluble fraction of aerosols Future work on clouds will look at differences in cloud top drizzle formation and auto-conversion rates between the different campaigns and at how well mixed phase clouds can be detected (if at all) from sensors such as VIIRS and PACE OCI.

Research Scanning Polarimeter↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

Ground Calibrations of the Clouds and the Earth's Radiant Energy System (CERES) Tropical Rainfall Measuring Mission Spacecraft Thermistor Bolometers

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft scanning thermistor bolometers will measure earth-reflected solar and earth-emmitted,longwave radiances, at the top-of-the-atmosphere. The measurements are performed in the broadband shortwave (0.3-5.0 micron) and longwave (5.0 - >100 micron) spectral regions as well as in the 8 -12 micron water vapor window over geographical footprints as small as 10 kilometers at the nadir. The CERES measurements are designed to improve our knowledge of the earth's natural climate processes, in particular those related to clouds, and man's impact upon climate as indicated by atmospheric temperature. November 1997, the first set of CERES bolometers is scheduled for launch on the Tropical Rainfall Measuring Mission (TRMM) Spacecraft. The CERES bolometers were calibrated radiometrically in a vacuum ground facility using absolute reference sources, tied to the International Temperature Scale of 1990. Accurate bolometer calibrations are dependent upon the derivations of the radiances from the spectral properties [reflectance, transmittance, emittance, etc.] of both the sources and bolometers. In this paper, the overall calibration approaches are discussed for the longwave and shortwave calibrations. The spectral responses for the TRMM bolometer units are presented and applied to the bolometer ground calibrations in order to determine pre-launch calibration gains.

Lee, Robert B., III↗

Determination of the in-flight spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

AVIRIS is a science research imaging spectrometer that measures radiance in 224 channels between 400 to 2450 nm in the electromagnetic spectrum. To determine the inflight spectral and radiometric characteristics of AVIRIS a validation and calibration experiment was performed. Five data sets were acquired over a calibration site on the homogeneous playa of Rogers Dry Lake, California, U.S. Surface reflectance, atmospheric optical depths, and atmospheric water vapor measurements were acquired concurrently with the overflights. These in situ measurements were used to constrain the LOWTRAN 7 radiative transfer code to predict the total spectral radiance incident at the AVIRIS aperture. These predicted radiances and the AVIRIS measured radiances were analyzed to validate the inflight characteristics. Inflight spectral channel positions and response functions over the AVIRIS spectral range were derived. Radiometric calibration coefficients were calculated for each channel as well as radiometric accuracy, intraflight stability, and noise equivalent delta radiance.

Green, Robert O.↗

NASA IKONOS Multispectral Radiometric Calibration and 3-Year Temporal Stability Assessment

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other system. In addition, the user community has little or no insight into the design and operation of commercial sensors or into the methods involved in generating commercial products. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) Directorate established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA, SSC,ESA, the University of Arizona Remote Sensing Group, and South Dacota State University. Each group determined the absolute radiometric calibration coefficients of the Space Imaging IKONOS 4-band, 4 m multispectral product covering the visible through near-infrared spectral region. For a three year period beginning in 2000, each team employed some variant of a reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with IKONOS image acquisitions and radiative transfer calculations. Several study sites throughout the United States were employed that covered nearly the entire dynamic range of the IKONOS sensor. IKONOS at-sensor radiance values were compared to those estimated by each independent group to determine the IKONOS sensor's radiometric accuracy and stability. Over 10 individual vicariously determined at-sensor radiance estimates were used each year. When combined, these estimates provided a high-precision radiometric gain calibration coefficient. No significant calibration offset was observed. The results of this evaluation provide the scientific community with an independent assessment of the IKONOS sensor's absolute calibration and temporal stability over the 3-year period. While the techniques and method described in this paper reflect those developed at the NASA SSC, the results of the entire team are included.

Pagnutti, Mary↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗