Search NASA⌕ Search

SEARCH · Search NASA

Results for “renewable heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermomagnetic generators for ultra-low-grade marine thermal energy harvesting

Low-grade thermal gradients in marine environments represent an underexploited energy source for autonomous sensing and monitoring. Converting such small temperature differences into usable electrical power remains a key challenge for ocean-deployed systems. We present a deployable thermomagnetic generator thoroughly characterized for marine-relevant energy harvesting. The device powers an internet-connected sensor and harvests ultra-low temperature differences akin to those at the ocean surface. It draws heat from water and rejects it to ambient air, operating optimally at a temperature difference (ΔT) of ~7.5 °C. Laboratory prototypes generated up to 6.7 mW at ΔT ~ 10 °C with gentle airflow (~1 m s -1 ). A separate controlled wave-tank demonstration validated stable operation and sensor powering under marine-like boundary conditions. Given its voltage and power margins, the generator could sustain multiple sensor nodes. Scalability and material assessments identify modular deployment and non-rare-earth alternatives as pathways toward practical marine energy harvesting and low-grade waste-heat recovery.

16 TIDAL AND WAVE POWER↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Numerical Investigation of Susceptor-Catalyst Design for Ethylene Generation in Radio Frequency Based Reactors

Ethylene is the most widely produced petrochemical component in the world. Whether reactors are heated directly or indirectly via steam, manufacturers use economies of scale to overcome inherent thermodynamic inefficiencies when burning fossil fuels. While allowing large-scale operations to use alternative sources of energy and raw materials, new methods of supplying energy to chemical reactor systems can reduce the energy waste produced by conventional processes. One viable method for effectively supplying energy to reactor systems is electromagnetic (EM) induction heating. Using the properties of radio frequency (RF) waves, heterogeneous catalysts can be precisely targeted for heating inside reactors. Site-selective heating can greatly lower the energy requirements of the process by supplying heat to reaction sites while reducing needless heat transfer elsewhere. In this study, a microscale model was used to help create guidelines for susceptors and catalysts to improve ethylene production. The oxidative dehydrogenation of ethane is investigated by utilizing several catalysts and potential catalyst/susceptor combinations, with heat provided by an EM susceptor. Having the susceptors and catalyst function separately results in higher gradients in both heat and mass transfer, which drives transport through the catalyst region, while still providing adequate heating for endothermic reactions. However, using a susceptive core with a catalyst covering produces the maximum ethylene concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passive radiative thermal management using phase-change metasurfaces

Abstract Realizing innovative composite materials with passive thermal management capabilities and minimal ecological footprints is a challenging but much sought-after goal that would have a transformative effect on renewable energy sciences. We demonstrate an environmentally friendly metasurface utilizing vanadium dioxide (VO 2 ) that offers responsiveness to ambient temperature and potentially long-term stability. The metasurface enables passive thermal management by self-adjusting its absorptivity and emissivity response over a broad bandwidth ranging from visible to mid-infrared (IR) wavelengths. Above the VO 2 phase transition the metasurface exhibits increased mid-IR emissivity and reduced visible/near-IR absorptivity, creating an efficient radiative emission channel in the first atmospheric transparency window with reduced absorption of solar radiation. In contrast, below VO 2 ’s transition temperature, the metasurface increasingly absorbs sun light while minimizing mid-IR radiative heat losses. Moreover, a functional silicon layer eliminates the need for an additional capping layer commonly employed to protect VO 2 from environmental degradation. The additional protective layer often impedes the use and performance of VO 2 based devices in terrestrial as well as spacecraft applications. Therefore, the proposed durable and eco-friendly metasurface will be an excellent candidate for essential passive thermal regulation systems across residential and terrestrial applications.

42 ENGINEERING↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities: Preprint

A wide range of utility applications require controllable switches with features such as high-voltage (HV) blocking and high-current carrying capacity especially at high pulse width modulation (PWM) frequency. Low and medium voltage utility applications such as motor drives and flexible AC transmission systems (FACTS) as well as solid state transformers (SST) could also benefit from a low-cost HV switching module. Wide band gap (WBG) semiconductors such as SiC and GaN MOSFETs are considered to be the present and next generation device choices, although they have their own limitations. For relatively HV applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low voltage regime. This manuscript proposes a new half bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in HV applications. Constructed from bare SiC dies, this half bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold and cooling, (3) integrated gate driver module with PWM over wi-fi to eliminate the need for low voltage signals, (4) wireless power transfer (WPT) enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state of health (SOH) estimator module onboard. The entire architecture has been designed and built at National Renewable Energy Laboratory (NREL), Golden, CO.

baseplate design↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Challenges and Roadmap for Solar-Thermal Desalination

Decarbonizing desalination systems requires combining renewable energy technologies with desalination systems. Solar thermal desalination, which combines a thermal desalination system (e.g., distillation, multistage flash, etc.) with a concentrated solar system is attractive in geographic regions with an abundance of saline water and solar energy. However, the high economic cost and low efficiency limits its adoption. This review provides an overview of the techno-economic, materials, and performance challenges that need to be overcome to realize solar-desalination. The review describes the four most prominent pathways for overcoming thermodynamic and cost limitations present in current systems. Specifically, methodologies and approaches such as direct solar evaporation structures, low-cost thermal energy storage, solar cogeneration schemes for power and desalination, and solar hybrid desalination are discussed. Furthermore, these strategies can enable solar thermal desalination technologies that are resilient to intermittent solar energy.

14 SOLAR ENERGY↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Supply and Demand Drivers of Global Hydrogen Deployment in the Transition toward a Decarbonized Energy System

The role of hydrogen in energy system decarbonization is being actively examined by the research and policy communities. We evaluate the potential ‘hydrogen economy’ in global climate change mitigation scenarios using the Global Change Analysis Model (GCAM). We consider major hydrogen production methods in conjunction with delivery options to understand how hydrogen infrastructure affects its deployment. We also consider a rich set of hydrogen end-use technologies and vary their costs to understand how demand technologies affect deployment. We find that the availability of hydrogen transmission and distribution infrastructure primarily affects the hydrogen production mix, particularly the share produced centrally versus onsite, whereas assumptions about end-use technology primarily affect the scale of hydrogen deployment. In effect, hydrogen can be a distributed energy vector, enabled by onsite renewable electrolysis and, to a lesser extent, by onsite industrial production using natural gas with carbon capture and storage (CCS). While the share of hydrogen in final energy is small relative to the share of other major energy carriers in our scenarios, hydrogen enables decarbonization in difficult-to-electrify end uses such as industrial high-temperature heat. Its contribution to greenhouse gas mitigation increases as the climate objective is tightened.

54 ENVIRONMENTAL SCIENCES↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of heat transfer enhancement techniques in two-phase flows for highly efficient and sustainable cooling

We show that two-phase internal flow is ubiquitous to many systems due to its ability to transfer large amounts of heat effectively. Recent advances motivated by sustainability have pushed towards augmenting the heat transfer between the tube and the two-phase working fluid. Augmenting heat transfer in two-phase flows enables process intensification, and compactness leading to reduced cost and material consumption. This review investigates the effect of heat transfer enhancement techniques on different fluids including R134a, R407C, R22, etc … The techniques are categorized into passive and active and focus on durable enhancement methods which do not include surface structuring or coating. Passive techniques utilize geometrical and surface modifications to induce better mixing. Several passive techniques are analyzed including fins, inserts, and more. In analyzing these techniques, the effect of changing geometric parameters is studied, and the limitations are highlighted. Further, active techniques that enable heat transfer enhancement through applying power are also investigated. Electrohydrodynamic approaches are analyzed and compared to passive techniques. Additionally, the implications of heat exchange enhancement in the context of global energy are discussed. An energy analysis discretized by the use sector is conducted, with an emphasis on predicting the future potential for renewable and sustainable development. Moreover, although active approaches provide the highest heat transfer enhancement, due to implementation difficulties, passive techniques are more frequently adopted. The review ends with discussion of next-generation heat exchangers which will rely more on additive manufacturing due to its flexibility and reduced cost per part as the technology matures.

Nusselt number↗

Insights Into Thermal Runaway Mechanisms: Fast Tomography Analysis of Metal Agglomerates in Lithium-Ion Batteries

Thermal Runaway (TR) in lithium-ion batteries (LIB) is a critical technological and social concern. Whilst such events are rare, TR is characterized by uncontrollable heating leading to catastrophic failures. To deepen the understanding of the failure process and subsequently develop more accurate TR prediction models and as a result safer battery systems, we present in this work high-speed X-ray tomography for in-depth investigations of the copper current collector melting and agglomeration during TR. The melting process presents valuable real-time internal information about heat evolution during TR, previously challenging to access but crucially important for validating TR models. In this work, controlled failure studies combined with high-speed X-ray tomography were performed on two different commercial LIB models, subjecting them to both external heating and nail penetration to induce TR. Through real-time observation via high-speed tomography, followed by segmentation, rendering, and analysis, the formation of copper agglomerates was qualitatively and quantitatively characterized and visualized for the first time. Agglomerates tended to form either from the battery's outermost layers or centrally, depending on the method of TR initiation, and gives an indirect insight into the internal temperature evolution and distribution. Moreover, an initial comparative analysis between the battery models also revealed differences in agglomerate size, which has been linked to the thicker copper current collectors of one of the cell models. We further discuss the impact of larger copper agglomerates on heat distribution and safety. This study not only sheds light on the intricate dynamics of TR in LIBs but also underscores the pivotal role of 'gold-standard' imaging techniques in advancing battery safety, crucial for the robust modeling of TR and the future design of electric vehicle safety systems.

25 ENERGY STORAGE↗

Life cycle assessment of a novel gas switching reforming for sustainable hydrogen production with CO2 capture

Gas switching reforming for hydrogen production (GSR-H2) presents an efficient, low-carbon hydrogen production method that incorporates integrated carbon capture, offering efficiency gains over traditional methods such as proton exchange membrane (PEM) electrolysis, steam methane reforming (SMR) and the newer method of chemical looping reforming (CLR). GSR-H2 has been demonstrated in lab scale which operates as an exothermic process that eliminates the need for additional natural gas combustion, using its own waste heat to generate process steam and partially offset energy usage through electricity production. Beyond its thermal self-sufficiency, GSR-H2 advances upon CLR by integrating all reaction stages within a single reactor cluster, eliminating the complexities of solid circulation, reducing capital costs, and enhancing overall process efficiency. This streamlined design simplifies scale-up and enables inherent CO2 separation with minimal energy penalty, making GSR-H2 a highly competitive pathway for low-carbon hydrogen production. This study presents the first life cycle assessment (LCA) of GSR-H2, offering a novel evaluation of this new process’s environmental impacts across diverse energy scenarios. Key findings reveal that in the renewables-powered scenario, GSR-H2 achieves a GWP of 2.77 kg CO2 eq per kg H2, a substantial improvement over SMR’s 10.4 kg CO2 eq and close to the low emissions of CLR (1.84 kg CO2 eq) and PEM electrolysis (1.85 kg CO2 eq). These results demonstrate GSR-H2’s competitive advantage as a lower-emission alternative, combining design simplicity and efficiency gains, especially in renewable-integrated systems. These results establish GSR-H2 as a competitive, scalable option for hydrogen production, particularly in decarbonization efforts.

03 NATURAL GAS↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗