Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Degradation of Beta-Cloth Covering for a Battery Orbital Replacement Unit in Low Earth Orbit

Samples from the B-cloth cover for a battery orbit replaceable unit from the International Space Station were characterized using optical and electron microscopy, UV-vis-NIR spectrophotometry, and x-ray energy dispersive spectroscopy. Results showed that in areas where the fabric was exposed to solar radiation the absorptance increased by as much as 20 percent, and the peak difference was in the ultraviolet, indicating that the increased absorptance may have been due to radiation. The emissivity of the material over a temperature range of 300 - 700 K was essentially unchanged.

Solar Physics↗

Multilfiltration Bed Replacement (MFBR) System for the International Space Station using Aquaporin Membranes and Humidity Condensate Ersatz Wastewater

The Multifiltration Bed system in the International Space Station (ISS) Water Processor Assembly (WPA) needs to be improved by reducing or eliminating the usage rate of expendable media, removing dimethylsilanediol (DMSD), and reducing the overall system mass. The WPA contains two multifiltration beds, each with a mass of approximately 50 kg. Reducing the mass of the WPA is an important part of evolving the ISS system for future exploration missions. The Multifiltration Bed Replacement (MFBR) technology is based on biomimetic membranes, which derive their unique characteristics from aquaporins, or water channel proteins. Aquaporin membranes were commercialized by the company Aquaporin AS. Tests were conducted using the Aquaporin Inside Hollow Fiber Module to determine the maximum water recovery ratio and membrane life. Samples were analyzed for total organic carbon (TOC), DMSD, acetate, ions, and volatiles such as ethanol and acetone. The results indicate that at a 97.498.1 water recovery ratio, the membrane module can reject approximately 50 of the TOC and specific conductance using the simulated ISS MSFC humidity condensate ersatz. Additionally, the life of the membrane was determined to be a minimum of 7103 hours.

humidity condensate ersatz↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive training on one platform without including a treadmill, such as the European Enhanced Exploration Exercise Device (E4D). It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40) who will partake in nominal exercise on the ISS, including running on the treadmill with vibration isolation system 2 (T2), ergometry on the cycle ergometer with vibration isolation and stabilization device (CEVIS), and strength training on the advanced resistive exercise device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. Results: Data collection for this study is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Preservation of Organic Carbon in Dolomitized Cambrian Stromatolites and Implications for Microbial Biosignatures in Diagenetically Replaced Carbonate Rock

Stromatolites have been a major focus in the search for ancient microbial life, however, the organic carbon biosignatures of dolomitized stromatolites have not yet been fully characterized or correlated with their dolomitizing conditions. Although dolomitization rarely preserves microbial morphology, the presence of organic carbon can provide valuable information for characterization of fossils’ biogenicity, syngenicity, and indigeneity to their host rock. The Cambrian Allentown Formation in New Jersey, USA, is an excellent example of dolomitized stromatolites and thrombolites containing diagenetically modified microbial biosignatures. Based on XRD and EPMA data, the dolomite composition is typically stoichiometric, with varying degrees of cationic ordering. The outcrop underwent early dolomitization in a marginal-marine setting and later burial diagenesis resulting in multi-generational dolomite formation: (1) 2 microspar dolomite formed by early diagenetic replacement at or near the surface, (2) zoned dolomite formed penecontemporaneously with the microspar phase as rhombohedral crystals by infilling primary pore spaces within the microspar matrix. The rhombic crystals continued to grow outward in alternating stages of Fe-enriched and -depleted fluids, which were preserved in zoned rims and revealed by cathodoluminescence, and (3) saddle dolomite formed during late stage deep burial with Fe- and Mn-rich fluids, and occurs as a void-filling, high-temperature phase. Organic carbon, characterized using confocal Raman microscopy, has an exclusive distribution within the microspar dolomite, and the D and G bands’ characteristics reveal similar thermal alteration to the host rock, indicating that the mapped organic carbon is indigenous and syngenetic with the Cambrian carbonates. The findings presented in this study reveal organic matter found within microspar of various dolomitized facies deriving from different source pools of organic carbon. This study sheds light on biosignatures in secondary dolostones and may aid biosignature detection in older carbonate rocks on Earth and Mars.

Dolomitization↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), Results: Eight subjects (2 Active [CEVIS + ARED], 6 Control) have been recruited for this study. Data collection is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Setting the Bar for the Replacement of the Probability of Collision Metric

Recent research in satellite conjunction risk assessment has levelled a number of criticisms at the probability of collision (Pc) parameter as a durable statement of satellite collision likelihood, and a number of different alternatives to this calculation have been proposed. Many of these proposals, however, stop at the outlining of the theory and do not discuss the additional philosophical and practical issues that must be confronted in evaluating such proposals for adoption. The present work seeks to outline some of these philosophical and practical considerations, and therefore the kinds of analyses and profiling that will be needed before the Pc, which is at present nearly universally adopted in the conjunction risk mitigation community, can be replaced with a new (and superior) paradigm and associated metric.

conjunction assessment↗

Building Automation System Replacement and Improvements during Concurrent Integration and Testing for the Spacecraft Systems Development and Integration Facility

The Spacecraft Systems Development and Integration Facility (SSDIF), the premier cleanroom for NASA Goddard Space Flight Center (GSFC), has gone through multiple iterations of changes to its building automation system (BAS). NASA flight projects require more stringent environmental controls for temperature, humidity, air exchange rates, and pressurization. This led to increasingly difficult circumstances with replacing and improving the BAS during Integration and Testing (I&T) operations. The SSDIF was partially transitioned to a new BAS during November and December of 2023. Transition occurred in a live environment, while regular I&T activities resumed for the Roman Space Telescope. This resulted in the development and execution of a comprehensive method of procedure. Strategies such as sequencing equipment transition, and using temporary controls for critical equipment, avoided detriments to cleanroom environment. While the new BAS was being built, data points on the previous system would become obsolete, leading to data gaps and uncertainties. Critical data points were distinguished and trended on the new system, providing key insights on equipment functionality, while the BAS was completed. Control hunting and environmental deviations were persistent cases with the SSDIF. In some instances, proportional-integral-derivative (PID) tuning was implemented on current logic to bring smooth PID loop hunting. In other situations, controls logic was completely altered by changing setpoints or sequences. This provided greater laminar flow, more stable pressurization, and improved temperature and humidity controls. This paper documents the transitionary procedure to a new BAS, the improvements made, and challenges faced when altering a BAS during I&T operations.

Cleanroom↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight on Astronaut Health and Performance

INTRODUCTION Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis missions to the Moon and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive capabilities on one platform without including a treadmill. The European Enhanced Exploration Exercise Device [E4D] is one such apparatus. It is critical to validate the efficacy of using exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the effectiveness of using nominal ISS exercise devices for an entire mission compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS Crewmembers are assigned to one of three groups: 1) Controls (n ≥ 40), who partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), cycling on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS), and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who exercise on the CEVIS and ARED only (n = 8); and 3) Active Group 2, who perform aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both Active groups are not permitted to perform treadmill exercise for the entirety of their flight. Health and performance markers, including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and after spaceflight. RESULTS Fifteen subjects (4 Active [CEVIS + ARED], 11 Control) have been recruited. Data collection is ongoing. CONCLUSIONS This study will assess the efficacy of using exploration exercise modalities, including removing the treadmill exercise capability or exclusively using the E4D, compared to the nominal ISS exercise regimen across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions. Supported by the NASA Human Research Program and NASA Exploration Capabilities

A N Varanoske↗

Performance properties of formulations containing diaminozoxyfurazan as replacements for PBXN-7

In an effort to increase safety and take advantage of extremely insensitive explosives like TATB, PBXN-7 was developed. It is an integral part of the insensitive munition (IM) effort and has contributed significantly to improvements seen in slow cook-off (SCO). Other explosives exist, while not as insensitive as TATB, which show promise in performance while maintaining insensitivity to common insults. Furazan chemistry developments over the past 30 years have yielded several, and Diaminoazoxyfurazan (DAAF) is one of the forerunners. DAAF has many intriguing properties, which indicated it might be a good fit in formulations designed to replace PBXN-7. A project funded through the Joint Insensitive Munitions Technology Program was launched in 2009 to develop and test formulations containing DAAF and RDX, DAAF and HMX, DAAF and TATB, and DAAF (by itself). All used the same binder, Viton, in 5 weight percent. The testing included performance testing with rate stick, shock sensitivity testing with the IHE gap test, and cold temperature performance testing with rate sticks and front curvature measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Programmatic mission capabilities - chemistry and metallurgy research replacement (CMRR) project

CMRR will have analysis capabilities that support all the nuclear-material programs and national security needs. CMRR will replace the aging CMR Building and provide a key component responsive infrastructure necessary to sustain all nuclear programs and the nuclear-weapons complex. Material characterization capabilities - evaluate the microstructures and properties of nuclear materials and provide experimental data to validate process and performance models. Analytical chemistry capabilities - provide expertise in chemical and radiochemical analysis of materials where actinide elements make up a significant portion of the sample.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design and development of a 3He replacement safeguards neutron counter based on 10B-lined proportional detector technology

This presentation represents an overview of the experimental evaluation of a boron-lined proportional technology performed within an NA-241 sponsored project on testing of boron-lined proportional counters for the purpose of replacement of {sup 3}He technologies. The presented boron-lined technology will be utilized in a design of a full scale safeguards neutron coincidence counter. The design considerations and the Monte Carlo performance predictions for the counter are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design Tools to Assess Hydro-Turbine Biological Performance: Priest Rapids Dam Turbine Replacement Project

Over the past two decades, there have been many studies describing injury mechanisms associated with turbine passage, the response of various fish species to these mechanisms, and the probability of survival through dams. Although developing tools to design turbines that improve passage survival has been difficult and slow, a more robust quantification of the turbine environment has emerged through integrating physical model data, fish survival data, and computational fluid dynamics (CFD) studies. Grant County Public Utility District (GCPUD) operates the Priest Rapids Dam (PRD), a hydroelectric facility on the Columbia River in Washington State. The dam contains 10 Kaplan-type turbine units that are now almost 50 years old. The Utility District plans to refit all of these aging turbines with new turbines. The Columbia River at PRD is a migratory pathway for several species of juvenile and adult salmonids, so passage of fish through the dam is a major consideration when replacing the turbines. In this presentation, a method for turbine biological performance assessment (BioPA) is introduced. Using this method, a suite of biological performance indicators is computed based on simulated data from a CFD model of a proposed turbine design. Each performance indicator is a measure of the probability of exposure to a certain dose of an injury mechanism. Using known relationships between the dose of an injury mechanism and frequency of injury (dose–response) from laboratory or field studies, the likelihood of fish injury for a turbine design can be computed from the performance indicator. By comparing the values of the indicators from proposed designs, the engineer can identify the more-promising alternatives. We will present application of the BioPA method for baseline risk assessment calculations for the existing Kaplan turbines at PRD that will be used as the minimum biological performance that a proposed new design must achieve.

CFD↗

Conceptual Design for Replacement of the DTL and CCL with Superconducting RF Cavities in the Spallation Neutron Source Linac

The Spallation Neutron Source Linac utilizes normal conducting RF cavities in the low energy section from 2.5 MeV to 186 MeV. Six Drift Tube Linac (DTL) structures accelerate the beam to 87 MeV, and four Coupled Cavity Linac (CCL) structures provide further acceleration to 186 MeV. The remainder of the Linac is comprised of 81 superconducting cavities packaged in 23 cryomodules to provide final beam energy of approximately 1 GeV. The superconducting Linac has proven to be substantially more reliable than the normal conducting Linac despite the greater number of stations and the complexity associated with the cryogenic plant and distribution. A conceptual design has been initiated on a replacement of the DTL and CCL with superconducting RF cavities. The motivation, constraints, and conceptual design are presented.

Champion, Mark S↗