Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution (optics)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

The XMM-Newton Extended Survey of the Taurus Molecular Cloud (XEST)

The Taurus Molecular Cloud (TMC) is the nearest large star-forming region, prototypical for the distributed mode of low-mass star formation. Pre-main sequence stars are luminous X-ray sources, probably mostly owing to magnetic energy release. Aims. The XMM-Newton Extended Survey of the Taurus Molecular Cloud (EST) presented in this paper surveys the most populated =5 square degrees of the TMC, using the XMM-Newton X-ray observatory to study the thermal structure, variability, and long-term evolution of hot plasma, to investigate the magnetic dynamo, and to search for new potential members of the association. Many targets are also studied in the optical, and high-resolution X-ray grating spectroscopy has been obtained for selected bright sources. Methods. The X-ray spectra have been coherently analyzed with two different thermal models (2-component thermal model, and a continuous emission measure distribution model). We present overall correlations with fundamental stellar parameters that were derived from the previous literature. A few detections from Chandra observations have been added. Results. The present overview paper introduces the project and provides the basic results from the X-ray analysis of all sources detected in the XEST survey. Comprehensive tables summarize the stellar properties of all targets surveyed. The survey goes deeper than previous X-ray surveys of Taurus by about an order of magnitude and for the first time systematically accesses very faint and strongly absorbed TMC objects. We find a detection rate of 85% and 98% for classical and weak-line T Tau stars (CTTS resp. WTTS), and identify about half of the surveyed protostars and brown dwarfs. Overall, 136 out of 169 surveyed stellar systems are detected. We describe an X-ray luminosity vs. mass correlation, discuss the distribution of X-ray-to-bolometric luminosity ratios, and show evidence for lower X-ray luminosities in CTTS compared to WTTS. Detailed analysis (e.g., variability, rotation-activity relations, influence of accretion on X-rays) will be discussed in a series of accompanying papers.

Guedel, M.↗

The Morphology of Passively Evolving Galaxies at Z-2 from HST/WFC3 in the Hubble Ultra Deep Field

We discuss near-IR images of six passive galaxies (SSFR< 10(exp -2)/Gyr) at redshift 1.3 < z < 2.4 with stellar mass M approx 10(exp 11) solar mass, selected from the Great Observatories Origins Deep Survey (GOODS), obtained with WFC3/IR and the Hubble Space Telescope (HST). These WFC3 images provide the deepest and highest angular resolution view of the optical rest-frame morphology of such systems to date. We find that the light profile of these; galaxies is generally regular and well described by a Sersic model with index typical of today's spheroids. We confirm the existence of compact and massive early-type galaxies at z approx. 2: four out of six galaxies have T(sub e) approx. 1 kpc or less. The WFC3 images achieve limiting surface brightness mu approx. 26.5 mag/sq arcsec in the F160W bandpass; yet there is no evidence of a faint halo in the five compact galaxies of our sample, nor is a halo observed in their stacked image. We also find very weak "morphological k-correction" in the galaxies between the rest-frame UV (from the ACS z band), and the rest-frame optical (WFC3 H band): the visual classification, Sersic indices and physical sizes of these galaxies are independent or only mildly dependent on the wavelength, within the errors.

Cassata, P.↗

The Morphology of Passively Evolving Galaxies at Z approximately 2 from HST/WFC3 Deep Imaging in the Hubble Ultradeep Field

We present near-IR images of six passive galaxies (SSFR< 10(exp -2)/ Gyr) at redshift 1.3 < z < 2.4 with stellar mass M approximately 10(exp 11) solar M, selected from the Great Observatories Origins Deep Survey (GOODS), obtained with the Hubble Space Telescope (HST) and the WFC3/IR camera. These images provide the deepest and highest angular resolution view of the optical rest-frame morphology of such systems to date. We find that the light profile of these galaxies is generally regular and well described by a Sersic model with index typical of today's spheroids. We confirm the existence of compact and massive early-type galaxies at z approximately 2: four out of six galaxies have r(sub e) approximately 1 kpc or less. The images reach limiting surface brightness mu approximates 26.5 mag/square arcsec in the F160W bandpass; yet there is no evidence of a faint halo in the galaxies of our sample, even in their stacked image. We also find very weak "morphological k-correction" in the galaxies between the rest-frame UV (from the ACS z-band), and the rest-frame optical (WFC3 H-band): the visual classification, Sersic indices and physical sizes of these galaxies are independent or only mildly dependent on the wavelength, within the errors. The presence of an active nucleus is suspected in two out of six galaxies (33%), opening the intriguing possibility that a large, presently unaccounted population of AGN is hosted in these galaxies, possibly responsible for the cessation of star formation.

Cassata, P.↗

Mirror Technology Development for The International X-Ray Observatory Mission

Presentation slides include: International X-ray Observatory (IXO), Lightweight and High Resolution X-ray Optics is Needed; Modular Design of Mirror Assembly, IXO Mirror Technology Development Objectives, Focus of Technology Development, Slumping - Status, Mirror Fabrication Progress, Temporary Bonding - Status, Alignment - Status, Permanent Bonding - Status, Mirror Housing Simulator (MHS) - TRL-4, Mini-Module (TRL-5), Flight-Like Module (TRL-6), Mirror Technology Development Team, Outlook, and Small Technology Firms that Have Made Direct Contributions to IXO Mirror Technology Development.

Zhang, Will↗

Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX

Singh, Jagdish P.↗

A l% and 1cm Perspective Leads to a Novel CDOM Absorption Algorithm

A next-generation in-water profiler designed to measure the apparent optical properties of seawater was developed and validated across a wide dynamic range of water properties. This new Compact-Optical Profiling System (C-OPS) design uses a novel, kite-shaped, free-falling backplane with adjustable buoyancy and is based on 19 state-of-the-art microradiometers, spanning 320-780 nm. Data collected as part of the field commissioning were of a previously unachievable quality and showed that systematic uncertainties in the sampling protocols were discernible at the 1% optical and 1cm depth resolution levels. A sensitivity analysis as a function of three water types, established by the peak in the remote sensing reflectance spectra, revealed which water types and spectral domains were the most indicative of data acquisition uncertainties. The unprecedented vertical resolution of C-OPS measurements provided near-surface data products at the spectral endpoints with a quality level that has not been obtainable. The improved data allowed development of an algorithm for predicting the spectral absorption due to chromophoric dissolved organic matter (CDOM) using ratios of diffuse attenuation coefficients with over 99% of the variance in the data explained.

Morrow, J. H.↗

PE-46 The Design of the Lynx X-Ray Microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be the next astrophysics flagship mission after WFIRST. One of Lynx's three instruments is an imaging spectrometer consisting of an x-ray microcalorimeter behind an X-ray optic with an angular resolution of 0.5 arc-seconds and approximately 3 sq m of area at 1 keV. This instrument will provide unparalleled diagnostics of distant extended structures and in particular will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the design and read-out of the of the array configuration including a number of sub-array options for increasing the capabilities to maximize the scientific return of the Lynx observatory.

Bandler, Simon↗

Flight Readiness of Mochii ISS-NL Portable Spectroscopic Electron Microscope

Electron microscopes (EM’s), are workhorse tools serving diverse fields such as materials science, biological science, and engineering. Scanning EM’s (SEM’s) in particular enable high magnification study and pinpoint chemical analyses of structures down to the nanoscale by providing a powerful blend of strong optical scattering, high native resolution, large depth of focus, and energy-dispersive X-ray spectroscopy (EDS). Mochii is the world’s smallest production electron microscope, scheduled to travel to the International Space Station (ISS) this spring where it will serve as an ISS National Laboratory (ISSNL) microgravity facility on successful demonstration. We previously reported on progress preparing Mochii for space flight, in particular flight integration verifications and science application testing. These included standard integration testing such as electromagnetic interference and flight vibration, and extend to unique functional testing such as magnetic susceptibility and extreme analog environment testing under the sea. Presently, Mochii payload flight hardware has completed testing and was handed over to NASA’s ISS payload processing facility in Houston. It will make its way to the the east coast for launch currently scheduled on Space-X CRS-20 for Mission increment 62 in March 2020.

Own, C. S.↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler↗

Deletion of Cdkn1a in Mice Rescues Reduced Osteogenesis in Microgravity and Increases Coupled Osteoclastic Bone Degenerative Activity and Bone Loss

Elevated Cdkn1a/p21 levels in mouse bone during spaceflight have led us to hypothesize that this cell cycle inhibitor could regulate osteogenesis in response to mechanical unloading in microgravity. Cdkn1a interacts with cyclins CDK1/2/4,6 during G1 and S phases, and suppression of its expression by mechanical stretch enhances proliferation and mineralization in osteoblastic cell cultures. To test this hypothesis in a whole-organism model, we used C57BL/J6 WT/Cdkn1a-null mice in the NASA RR-10, 30-day ISS microgravity experiment. To quantify active mineralization in microgravity mice were injected with Calcein seven and two days before euthanasia on-orbit, followed by high-resolution confocal imaging of optically cleared femoral endosteal surfaces. To quantify cortical and cancellous bone parameters we conducted microCT analyses of the femur and tibia. Confocal imaging revealed a population of mineralizing calcein-positive single osteoblasts, and multicellular surfaces of mineralization by osteocytes in lacunae. The Cdkn1a-null genotype shows a greater ratio of early-osteoblasts to late-osteocytes and reduced mineralization versus WT. Additionally, in microgravity WT bones have a large (80%) decrease in active mineralization, but remarkably Cdkn1a deletion fully rescued mineralized surface loss. MicroCT shows trends for moderate spaceflight bone loss in WT femurs, and significant losses in the tibia, while Cdkn1a-null femurs showed much larger significant tissue losses, including 25% thinner trabeculae (p < 0.01),40% thinner cortical bone (p < 0.005), and 10% lower percent cortical bone area (p < 0.05). These results indicate that endogenous bone Cdkn1a plays a key role in mechanosensitive downregulation of osteoprecursor proliferation and promotes osteocytic differentiation. In microgravity however, while Cdkn1a deletion rescues mineralization, bone loss quantified by microCT is greatly increased, likely due to the molecular coupling of osteogenesis and osteoclastogenesis. This molecular mechanism opens the possibility for potential pharmacological approaches to mitigate bone loss in space simultaneously targeting Cdkn1a and osteoclast inhibition.

Eduardo A.C. Almeida↗

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler↗

Seasonal Monitoring and Estimation of Regional Aerosol Distribution over Po Valley, Northern Italy, Using a High-Resolution MAIAC Product

In this work, the new 1-km-resolved Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm is employed to characterize seasonal AOD-PM10 correlations over northern Italy. The accuracy of the new dataset is assessed versus the widely used Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 5.1 Aerosol Optical Depth (AOD) data, retrieved at 0.55 microns with spatial resolution of 10 km (MYD04). We focused on evaluating the ability of these two products to characterize both temporal and spatial distributions of aerosols within urban and suburban areas. Ground PM10 measurements were obtained from 73 of the Italian Regional Agency for Environmental Protection (ARPA) monitoring stations, spread across northern Italy, for a three-year period from 2010 to 2012. The Po Valley area (northern Italy) was chosen as the study domain because of severe urban air pollution, resulting from the highest population and industrial manufacturing density in the country, being located in a valley where two surrounding mountain chains favor the stagnation of pollutants. We found that the global correlations between PM10 and AOD are R(sup 2) = 0.83 and R(sup 2) = 0.44 for MYD04_L2 and for MAIAC, respectively, suggesting for a greater sensitiveness of the high-resolution product to small-scale deviations. However, the introduction of Relative Humidity (RH) and Planetary Boundary Layer (PBL) depth corrections gave a significant improvement to the PM AOD correlation, which led to similar performance: R(sup 2) = 0.96 for MODIS and R(sup 2) = 0.95 for MAIAC. Furthermore, the introduction of the PBL information in the corrected AOD values was found to be crucial in order to capture the clear seasonal cycle shown by measured PM10 values. The study allowed us to define four seasonal linear correlations that estimate PM10 concentrations satisfactorily from the remotely sensed MAIAC AOD retrieval. Overall, the results show that the high resolution provided by MAIAC retrieval data is much more relevant than 10km MODIS data to characterize PM10 in this region of Italy which has a pretty limited geographical domain, but a broad variety of land usages and consequent particulate concentrations.

MODIS↗

Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation

A common problem in optical detection is determining the arrival time of a weak optical pulse that may comprise only one to a few photons. Currently, this problem is solved by using a photodetector to convert the optical signal to an electronic signal. The timing of the electrical signal is used to infer the timing of the optical pulse, but error is introduced by random delay between the absorption of the optical pulse and the creation of the electrical one. To eliminate this error, a time-to-space converter separates a sequence of optical pulses and sends them to different photodetectors, depending on their arrival time. The random delay, called jitter, is at least 20 picoseconds for the best detectors capable of detecting the weakest optical pulses, a single photon, and can be as great as 500 picoseconds. This limits the resolution with which the timing of the optical pulse can be measured. The time-to-space converter overcomes this limitation. Generally, the time-to-space converter imparts a time-dependent momentum shift to the incoming optical pulses, followed by an optical system that separates photons of different momenta. As an example, an electro-optic phase modulator can be used to apply longitudinal momentum changes (frequency changes) that vary in time, followed by an optical spectrometer (such as a diffraction grating), which separates photons with different momenta into different paths and directs them to impinge upon an array of photodetectors. The pulse arrival time is then inferred by measuring which photodetector receives the pulse. The use of a time-to-space converter mitigates detector jitter and improves the resolution with which the timing of an optical pulse is determined. Also, the application of the converter enables the demodulation of a pulse position modulated signal (PPM) at higher bandwidths than using previous photodetector technology. This allows the creation of a receiver for a communication system with high bandwidth and high bits/photon efficiency.

Birnbaum, Kevin↗

Optical analysis of a compound quasi-microscope for planetary landers

A quasi-microscope concept, consisting of facsimile camera augmented with an auxiliary lens as a magnifier, was introduced and analyzed. The performance achievable with this concept was primarily limited by a trade-off between resolution and object field; this approach leads to a limiting resolution of 20 microns when used with the Viking lander camera (which has an angular resolution of 0.04 deg). An optical system is analyzed which includes a field lens between camera and auxiliary lens to overcome this limitation. It is found that this system, referred to as a compound quasi-microscope, can provide improved resolution (to about 2 microns ) and a larger object field. However, this improvement is at the expense of increased complexity, special camera design requirements, and tighter tolerances on the distances between optical components.

Wall, S. D.↗

Environmental Public Health Surveillance for Exposure to Respiratory Health Hazards: A Joint NASA/CDC Project to Use Remote Sensing Data for Estimating Airborne Particulate Matter Over the Atlanta, Georgia Metropolitan Area

As part of the National Environmental Public Health Tracking Network (EPHTN) the National Center for Environmental Health (NCEH) at the Centers for Disease Control and Prevention (CDC) is leading a project called Health and Environment Linked for Information Exchange (HELiX-Atlanta). The goal of developing the National Environmental Public Health Tracking Network is to improve the health of communities. Currently, few systems exist at the state or national level to concurrently track many of the exposures and health effects that might be associated with environmental hazards. An additional challenge is estimating exposure to environmental hazards such as particulate matter whose aerodynamic diameter is less than or equal to 2.5 micrometers (PM2.5). HELIX-Atlanta's goal is to examine the feasibility of building an integrated electronic health and environmental data network in five counties of Metropolitan Atlanta, GA. NASA Marshall Space Flight Center (NASA/MSFC) is collaborating with CDC to combine NASA earth science satellite observations related to air quality and environmental monitoring data to model surface estimates of PM2.5 concentrations that can be linked with clinic visits for asthma. While use of the Air Quality System (AQS) PM2.5 data alone could meet HELIX-Atlanta specifications, there are only five AQS sites in the Atlanta area, thus the spatial coverage is not ideal. We are using NASA Moderate Resolution Imaging Spectroradiometer (MODIS) satellite Aerosol Optical Depth (AOD) data for estimating daily ground level PM2.5 at 10 km resolution over the metropolitan Atlanta area supplementing the AQS ground observations and filling their spatial and temporal gaps.

Quattrochi, Dale A.↗

High-resolution CCD imagers using area-array CCD's for sensing spectral components of an optical line image

CCD imagers with a novel replicated-line-imager architecture are abutted to form an extended line sensor. The sensor is preceded by optics having a slit aperture and having an optical beam splitter or astigmatic lens for projecting multiple line images through an optical color-discriminating stripe filter to the CCD imagers. A very high resolution camera suitable for use in a satellite, for example, is thus provided. The replicated-line architecture of the imager comprises an area-array CCD, successive rows of which are illuminated by replications of the same line segment, as transmitted by respective color filter stripes. The charge packets formed by accumulation of photoresponsive charge in the area-array CCD are read out row by row. Each successive row of charge packets is then converted from parallel to serial format in a CCD line register and its amplitude sensed to generate a line of output signal.

Elabd, Hammam↗

Low-Mass Planar Photonic Imaging Sensor

Continuing on the successful progress of NIAC (NASA Innovative Advanced Concepts) Phase I, this report summarizes the technical progress achieved under NIAC Phase II during the performance period September 19, 2014 to June 18, 2017. During this period, the research team has made the following accomplishments: designed and layout a silica photonic integrated circuit (PIC) as a two baselineinterferometric imager; constructed an experiment to utilize the two baselines for complex visibility measurementon a point source and a variable width slit; analyzed and studied the testbed results (in collaboration with Lockheed Martin); designed and layout Si3N4 PICs for the low-resolution and high-resolution SPIDER (Segmented Planar Imaging Detector for Electro-Optical Reconnaissance) telescope; fabricated the multi-layer Si3N4 PIC for low and high resolution SPIDER telescope; characterized the optical throughput and heater response for Si3N4 PIC for low and highresolution SPIDER telescopes; carried out imaging experiments using the Si3N4 PIC low-resolution version (in collaboration with Lockheed Martin); investigated signal-to-noise (SNR) ratio of SPIDER imager compared to the conventional panchromatic imager (in collaboration with Lockheed Martin); fulfilled the SNR simulation upon SPIDER imager (in collaboration with Lockheed Martin).

Yoo, S. J. Ben↗

Grazing Incidence Optics Technology

This project is to demonstrate the capability to directly fabricate lightweight, high-resolution, grazing-incidence x-ray optics using a commercially available robotic polishing machine. Typical x-ray optics production at NASA Marshall Space Flight Center (MSFC) uses a replication process in which metal mirrors are electroformed on to figured and polished mandrels from which they are later removed. The attraction of this process is that multiple copies can be made from a single master. The drawback is that the replication process limits the angular resolution that can be attained. By directly fabricating each shell, errors inherent in the replication process are removed. The principal challenge now becomes how to support the mirror shell during all aspects of fabrication, including the necessary metrology to converge on the required mirror performance specifications. This program makes use of a Zeeko seven-axis computer-controlled polishing machine (see fig. 1) and supporting fabrication, metrology, and test equipment at MSFC. The overall development plan calls for proof-of-concept demonstration with relatively thick mirror shells (5-6 mm, fig. 2) which are straightforward to support and then a transition to much thinner shells (2-3 mm), which are an order of magnitude thinner than those used for Chandra. Both glass and metal substrates are being investigated. Currently, a thick glass shell is being figured. This has enabled experience to be gained with programming and operating the polishing machine without worrying about shell distortions or breakage. It has also allowed time for more complex support mechanisms for figuring/ polishing and metrology to be designed for the more challenging thinner shells. These are now in fabrication. Figure 1: Zeeko polishing machine.

Ramsey, Brian↗