Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

HDSense: An efficient method for ranking observable sensitivity

Identifying which observables most effectively constrain model parameters can be computationally prohibitive when considering full likelihoods of many correlated observables. This is especially important for, e.g., hadronization models, where high precision is required to interpret the results of collider experiments. We introduce the High-Dimensional Sensitivity (HDSense) score, a computationally efficient metric for ranking observable sets using only one-dimensional histograms. Derived by profiling over unknown correlations in the Fisher information framework, the score balances total information content against redundancy between observables. We apply HDSense to rank a set observables in terms of their constraining power with respect to five parameters of the Lund string model of hadronization implemented in Pythia using simulated leptonic collider events at the $Z$ pole. Validation against machine-learning--based full-likelihood approximations demonstrates that HDSense successfully identifies near-optimal observable subsets. The framework naturally handles data from multiple experiments with different acceptances and incorporates detector effects. While demonstrated on hadronization models, the methodology applies broadly to generic parameter estimation problems where correlations are unknown or difficult to model.

Assi, Benoît [Cincinnati U.] (ORCID:00000003092433↗

Continuous-energy eigenvalue sensitivity coefficient calculations in TSUNAMI-3D

Two methods for calculating eigenvalue sensitivity coefficients in continuous-energy Monte Carlo applications were implemented in the KENO code within the SCALE code package. The methods were used to calculate sensitivity coefficients for several test problems and produced sensitivity coefficients that agreed well with both reference sensitivities and multigroup TSUNAMI-3D sensitivity coefficients. The newly developed CLUTCH method was observed to produce sensitivity coefficients with high figures of merit and a low memory footprint, and both continuous-energy sensitivity methods met or exceeded the accuracy of the multigroup TSUNAMI-3D calculations. (authors)

97 MATHEMATICS AND COMPUTING↗

Least Squares Shadowing sensitivity analysis of chaotic limit cycle oscillations

The adjoint method, among other sensitivity analysis methods, can fail in chaotic dynamical systems. The result from these methods can be too large, often by orders of magnitude, when the result is the derivative of a long time averaged quantity. This failure is known to be caused by ill-conditioned initial value problems. This paper overcomes this failure by replacing the initial value problem with the well-conditioned “least squares shadowing (LSS) problem”. The LSS problem is then linearized in our sensitivity analysis algorithm, which computes a derivative that converges to the derivative of the infinitely long time average. We demonstrate our algorithm in several dynamical systems exhibiting both periodic and chaotic oscillations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Assessment of Multiple Monitoring Methods for Detection of Brine and CO2 Leakage

We assess the effectiveness of four surface-based geophysical methods and in situ monitoring of pressure and chemical changes for detecting brine and CO2 leakage from legacy wells into underground sources of drinking water (USDW) overlying a CO2 storage reservoir. This is the first such effort to evaluate and compare six monitoring methods for detection of CO2 leakage. This assessment, conducted in support of the USDOE National Risk Assessment Partnership (NRAP), utilizes 3000 synthetic data sets, generated in an uncertainty quantification (UQ) model framework. This framework combines the results of (1) a CO2 storage reservoir model of a hypothetical storage operation of 5 MT/yr for 50 years into the 1700-m deep Vedder Fm. at a site near Kimberlina, California with (2) wellbore leakage models of a legacy well and (3) multi-phase flow and reactive transport models of brine and CO2 plume migration in aquifer layers overlying the storage reservoir. Leakage drives subsurface changes, quantified by pressure plumes, CO2-saturation plumes, and total dissolved solids (TDS) plumes, the latter being related to changes in pH and species concentrations. Depending on the depth of leakage, aquifer permeability, and regional groundwater gradient, pressure plume volumes can become larger than the CO2 and TDS plumes; however, reaching detectable thresholds may take too long to be useful. For a single monitoring well located 500 m downgradient of a leaky legacy well, a depth of 570 m is found to be optimal for sampling pressure and chemical changes. We assess four surface-based geophysical monitoring methods: electrical resistivity tomography (ERT), magnetotellurics (MT), gravity, and seismic methods. Sensors cover a 4-km × 2-km area. Both ERT and MT methods are sensitive to changes in CO2 saturation and TDS concentration, whereas gravity and seismic methods detect changes in CO2 saturation. The six monitoring methods complement each other in space and time, and we find that a minimum of 20 kT of CO2 leakage is required for the leakage plume to be detected. Of the four surface-based geophysical methods, gravity monitoring appears to be the most sensitive to CO2 leaks, while the usefulness of in situ pressure and chemical monitoring will depend on the level of unfilterable background noise. Geophysical monitoring methods may detect a leak anywhere in a large area and in a large depth range, but the effectiveness of pressure and chemical monitoring depends on the number of monitoring wells, where those wells are located, and the depth of sampling. Surface-based geophysical monitoring methods are cost-effective alternatives to in situ pressure and chemical monitoring methods.

NRAP, CCS, monitoring, geophysical methods, gravit↗

Global sensitivity analysis in stochastic simulators of uncertain reaction networks

Stochastic models of chemical systems are often subjected to uncertainties in kinetic parameters in addition to the inherent random nature of their dynamics. Uncertainty quantification in such systems is generally achieved by means of sensitivity analyses in which one characterizes the variability with the uncertain kinetic parameters of the first statistical moments of model predictions. In this work, we propose an original global sensitivity analysis method where the parametric and inherent variability sources are both treated through Sobol’s decomposition of the variance into contributions from arbitrary subset of uncertain parameters and stochastic reaction channels. The conceptual development only assumes that the inherent and parametric sources are independent, and considers the Poisson processes in the random-time-change representation of the state dynamics as the fundamental objects governing the inherent stochasticity. Here, a sampling algorithm is proposed to perform the global sensitivity analysis, and to estimate the partial variances and sensitivity indices characterizing the importance of the various sources of variability and their interactions. The birth-death and Schlögl models are used to illustrate both the implementation of the algorithm and the richness of the proposed analysis method. The output of the proposed sensitivity analysis is also contrasted with a local derivative-based sensitivity analysis method classically used for this type of systems.

97 MATHEMATICS AND COMPUTING↗

Adjoint methods for aerodynamic wing design

A model inverse design problem is used to investigate the effect of flow discontinuities on the optimization process. The optimization involves finding the cross-sectional area distribution of a duct that produces velocities that closely match a targeted velocity distribution. Quasi-one-dimensional flow theory is used, and the target is chosen to have a shock wave in its distribution. The objective function which quantifies the difference between the targeted and calculated velocity distributions may become non-smooth due to the interaction between the shock and the discretization of the flowfield. This paper offers two techniques to resolve the resulting problems for the optimization algorithms. The first, shock-fitting, involves careful integration of the objective function through the shock wave. The second, coordinate straining with shock penalty, uses a coordinate transformation to align the calculated shock with the target and then adds a penalty proportional to the square of the distance between the shocks. The techniques are tested using several popular sensitivity and optimization methods, including finite-differences, and direct and adjoint discrete sensitivity methods. Two optimization strategies, Gauss-Newton and sequential quadratic programming (SQP), are used to drive the objective function to a minimum.

Grossman, Bernard↗

Preliminary Structural Sensitivity Study of Hypersonic Inflatable Aerodynamic Decelerator Using Probabilistic Methods

Acceptance of new spacecraft structural architectures and concepts requires validated design methods to minimize the expense involved with technology validation via flighttesting. This paper explores the implementation of probabilistic methods in the sensitivity analysis of the structural response of a Hypersonic Inflatable Aerodynamic Decelerator (HIAD). HIAD architectures are attractive for spacecraft deceleration because they are lightweight, store compactly, and utilize the atmosphere to decelerate a spacecraft during re-entry. However, designers are hesitant to include these inflatable approaches for large payloads or spacecraft because of the lack of flight validation. In the example presented here, the structural parameters of an existing HIAD model have been varied to illustrate the design approach utilizing uncertainty-based methods. Surrogate models have been used to reduce computational expense several orders of magnitude. The suitability of the design is based on assessing variation in the resulting cone angle. The acceptable cone angle variation would rely on the aerodynamic requirements.

Lyle, Karen H.↗

Results of an integrated structure/control law design sensitivity analysis

A design sensitivity analysis method for Linear Quadratic Cost, Gaussian (LQG) optimal control laws, which predicts change in the optimal control law due to changes in fixed problem parameters using analytical sensitivity equations is discussed. Numerical results of a design sensitivity analysis for a realistic aeroservoelastic aircraft example are presented. In this example, the sensitivity of the optimally controlled aircraft's response to various problem formulation and physical aircraft parameters is determined. These results are used to predict the aircraft's new optimally controlled response if the parameter was to have some other nominal value during the control law design process. The sensitivity results are validated by recomputing the optimal control law for discrete variations in parameters, computing the new actual aircraft response, and comparing with the predicted response. These results show an improvement in sensitivity accuracy for integrated design purposes over methods which do not include changes in the optimal control law. Use of the analytical LQG sensitivity expressions is also shown to be more efficient than finite difference methods for the computation of the equivalent sensitivity information.

Gilbert, Michael G.↗

On the characterization of biases arising from methods and approximations used for sensitivity analyses

The preliminary assessment of the performance and safety of advanced reactors, as well as the identification of research and development needs, rely on computer simulations due to the lack of operational experience. Those simulations should be based on verified and validated computational tools, calculation schemes, and nuclear data libraries, and should be accompanied of a proper characterization of the involved uncertainties, providing confidence in the computational-based predictions. Thus, sensitivity and uncertainty studies, together with integral experiments, play an essential role in that process. Sensitivities are then a critical element and guidelines about how to produce accurate enough sensitivities depending on the subsequent analyses to be performed are of interest. The present study addresses the sensitivities biases arising from the use of different nuclear data libraries, computational methods and the assumption of modelling simplifications. Not only sensitivities for multiplication factor but also for safety-relevant reactivity responses have been analyzed. In the study, propagated uncertainties are also included for the considered parameters to illustrate the impact of the sensitivity profiles obtained for each case on the final uncertainty. Then, relevant recommendations are given for sensitivity analyses of highly complex systems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Bayesian Networks for Sensitivity Analysis of Complex Biogeochemical Models

Sensitivity analysis is a vital tool in numerical modeling to identify important parameters and processes that contribute to the overall uncertainty in model outputs. We developed a new sensitivity analysis method to quantify the relative importance of uncertain model processes that contain multiple uncertain parameters. The method is based on the concepts of Bayesian networks (BNs) to account for complex hierarchical uncertainty structure of a model system. We derived a new set of sensitivity indices using the methodology of variance-based global sensitivity analysis with the Bayesian inference. The framework is capable of representing the detailed uncertainty information of a complex model system using BNs and affords flexible grouping of different uncertain inputs given their characteristics and dependency structures. We have implemented the method on a real-world biogeochemical model at the groundwater-surface water interface within the Hanford Site’s 300 Area. The uncertainty sources of the model were first grouped into forcing scenario and three different processes based on our understanding of the complex system. The sensitivity analysis results indicate that both the reactive transport and groundwater flow processes are important sources of uncertainty for carbon-consumption predictions. Within the groundwater flow process, the structure of geological formations is more important than the permeability heterogeneity within a given geological formation. Our new sensitivity analysis framework based on BNs offers substantial flexibility for investigating the importance of combinations of interacting uncertainty sources in a hierarchical order, and it is expected to be applicable to a wide range of multi-physics models for complex systems.

Dai, Heng↗

A novel method to evaluate gamma camera rotational uniformity and sensitivity variation

An alternative to the conventional method of performing the AAPM Report 52 rotational uniformity and sensitivity test has been developed. In contrast to the conventional method in which a Co-57 sheet source is fastened to the collimator, this new point-source method acquires the images intrinsically using a Tc-99m point source placed near the isocenter of gantry rotation. As with the conventional method, the point-source method acquires 5x10{sup 6} count flood images at four distinct gantry positions to calculate the maximum sensitivity variation (MSV)--a quantitative metric of rotational uniformity and sensitivity variation. The point-source method incorporates corrections for the decay of Tc-99m between acquisitions, the curvature in the image intensity due to variation in photon flux across the detector from a near-field source, and the source-to-detector distance variations between views. The raw point-source images were fitted with an analytic function in order to compute curvature- and distance-corrected images prior to analysis. Five independent MSV measurements were performed using both conventional and point-source methods on a single detector of a dual-headed SPECT system to estimate the precision of each method. The precision of the point-source method was further investigated by performing ten independent measurements of MSV on six different detectors. Correlation between the MSV calculated by the two methods was investigated by performing the test on nine different detectors using both methods. Different levels of sensitivity variations were also simulated on four detectors to generate 40 additional paired points for correlation analysis. The effect of the total image counts on the MSV estimated with the new method was evaluated by acquiring image sequences with 5x10{sup 6}, 10x10{sup 6}, and 20x10{sup 6} count images. The MSV calculated using the conventional and point-source methods exhibited a high degree of correlation and consistency with equivalence. The precision of the point-source method (0.145%) is lower than the conventional method (0.04%) but sufficient to test MSV. No statistically significant dependence of MSV with the point-source method on the total image counts over a range of (5-20)x10{sup 6} counts was observed. Curvature correction of the images prior to the generation of difference images renders images more conducive to qualitative inspection for structured, nonrandom patterns. The advantages of the new methodology are that multiple detectors of a gamma camera can be evaluated simultaneously which substantially reduces the time required for MSV testing and the reduced risk of accidental damage to the collimators and patient proximity detection system from having to mount a sheet source on each of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-contact, thermal noise based method for the calibration of lateral deflection sensitivity in atomic force microscopy

Calibration of lateral forces and displacements has been a long standing problem in lateral force microscopies. Recently, it was shown by Wagner et al. that the thermal noise spectrum of the first torsional mode may be used to calibrate the deflection sensitivity of the detector. This method is quick, non-destructive and may be performed in situ in air or liquid. Here we make a full quantitative comparison of the lateral inverse optical lever sensitivity obtained by the lateral thermal noise method and the shape independent method developed by Anderson et al. We find that the thermal method provides accurate results for a wide variety of rectangular cantilevers, provided that the geometry of the cantilever is suitable for torsional stiffness calibration by the torsional Sader method, in-plane bending of the cantilever may be eliminated or accounted for and that any scaling of the lateral deflection signal between the measurement of the lateral thermal noise and the measurement of the lateral deflection is eliminated or corrected for. We also demonstrate that the thermal method may be used to characterize the linearity of the detector signal as a function of position, and find a deviation of less than 8% for the instrument used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shape optimization of single- and two-element airfoils on multiblock grids

A multiblock, discrete sensitivity analysis method is used to couple a direct optimization method and a flow analysis method. The domain is divided into smaller subdomains for which the sensitivities are obtained separately. Then, an effective sensitivity equation is solved to complete the coupling of all the sensitivity information. The flow analysis is based on the thin-layer Navier-Stokes equations solved by an implicit, upwind-biased, finite-volume method. The method of feasible directions is used for the present gradient-based optimization approach. First, a transonic airfoil is optimized to investigate the behavior of the method in highly nonlinear flows as well as the effect of different blocking strategies on the procedure. A supercritical airfoil is produced from an initially symmetric airfoil with multiblocking affecting the path but not the final shape. Secondly, a two-element airfoil is shape optimized in subsonic flow to demonstrate the present method's capability of shaping aerodynamically interfering elements simultaneously. For a very low and a very high Reynolds number cases, the shape of the main airfoil and the flap are optimized to yield improved lift-to-drag ratios.

Lacasse, James M.↗

A Simple and Sensitive LC-MS/MS Method for the Determination of Free 8-Hydroxy-2'-Deoxyguanosine in Human Urine

Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.

Wang, Zuwei↗