Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

High-energy X-ray spectra of Cygnus XR-1 observed from OSO 8

X-ray spectra of Cygnus XR-1 were measured with the scintillation spectrometer aboard the OSO 8 satellite during a period of one-and-one-half to three weeks in each of the years from 1975 to 1977. Typical spectra of the source between 15 and 250 keV are presented and the spectra are found to be well represented by a single power-law expression whose photon number spectral index is different for the two intensity states that were considered. The observed pivoting effect is consistent with two-temperature accretion disk models of the X-ray emitting region.

Dolan, J. F.↗

Compressional behavior of omphacite to 47 GPa

Omphacite is an important mineral component of eclogite. Single crystal synchrotron X-ray diffraction data on natural (Ca,Na)(Mg,Fe,Al)Si 2 O 6 omphacite have been collected at the Advanced Photon Source beamlines 13-BM-C and 13-ID-D up to 47 GPa at ambient temperature. Unit cell parameter and crystal structure refinements were carried out to constrain the isothermal equation of state and compression mechanism. The 3rd order Birch-Murnaghan equation of state (BM3) fit of all data gives V o = 423.9(3) Å3, K To = 116(2) GPa and K To ’ = 4.3(2). These elastic parameters are consistent with the general trend of the diopside-jadeite join. The eight-coordinated polyhedra (M2 and M21) are the most compressible, and contribute to majority of the unit cell compression, while the SiO 4 tetrahedra (Si1 and Si2) behave as rigid structural units and are the most incompressible. Axial compressibilities are determined by fitting linearized BM 3 equation of state to pressure dependences of unit cell parameters. Throughout the investigated pressure range, the b-axis is more compressible than the c-axis. Here, the axial compressibility of the α-axis is the largest among the three axes at 0 GPa, yet it quickly drops to the smallest at pressures above 5 GPa, which is explained by the rotation of the stiffest compression axis toward the a-axis with the increase of pressure.

36 MATERIALS SCIENCE↗

High flux coherent super-continuum soft X-ray source driven by a single-stage, 10mJ, Ti:sapphire amplifier-pumped OPA

We demonstrate the highest flux tabletop source of coherent soft X-rays to date, driven by a single-stage 10 mJ Ti:sapphire regenerative amplifier at 1 kHz. We first down-convert the laser to 1.3 µm using a parametric amplifier, before up-converting it to soft X-rays using high harmonic generation in a high-pressure, phase matched, hollow waveguide geometry. The resulting optimally phase matched broadband spectrum extends to 200 eV, with a soft X-ray photon flux of > 10 6 photons/pulse/1% bandwidth at 1 kHz, corresponding to > 10 9 photons/s/1% bandwidth, or approximately a three order-of-magnitude increase compared with past work. Finally, using this broad bandwidth X-ray source, we demonstrate X-ray absorption spectroscopy of multiple elements and transitions in molecules in a single spectrum, with a spectral resolution of 0.25 eV, and with the ability to resolve the near edge fine structure.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pair Production and Annihilation in Strong Magnetic Fields

Electromagnetic phenomena occurring in the presence of strong magnetic fields are currently of great interest in high-energy astrophysics. In particular, the process of pair production by single photons in the presence of fields of order 10 to the 12th power Gauss is of importance in cascade models of pulsar gamma ray emission, and may also become significant in theories of other radiation phenomena whose sources may be neutron stars (e.g., gamma ray bursts). In addition to pair production, the inverse process of pair annihilation is greatly affected by the presence of superstrong magnetic fields. The most significant departures from annihilation processes in free space are a reduction in the total rate for annihilation into two photons, a broadening of the familiar 511-keV line for annihilation at rest, and the possibility for annihilation into a single photon (which dominates the two-photon annihilation for B ( 10 the 13th power Gauss). The physics of these pair conversion processes, which is reviewed briefly, can become quite complex in the teragauss regime, and can involve calculations which are technically difficult to incorporate into models of emission mechanisms in neutron star magnetospheres. However, theoretical work, especially the case of pair annihilation, also suggests potential techniques for more direct measurements of field strengths near the stellar surface.

Daugherty, J. K.↗

Pair production and annihilation in strong magnetic fields

Electromagnetic phenomena occurring in the presence of strong magnetic fields are currently of great interest in high-energy astrophysics. In particular, the process of pair production by single photons in the presence of fields of order 10 to the 12th power Gauss is of importance in cascade models of pulsar gamma ray emission, and may also become significant in theories of other radiation phenomena whose sources may be neutron stars (e.g., gamma ray bursts). In addition to pair production, the inverse process of pair annihilation is greatly affected by the presence of superstrong magnetic fields. The most significant departures from annihilation processes in free space are a reduction in the total rate for annihilation into two photons, a broadening of the familiar 511-keV line for annihilation at rest, and the possibility for annihilation into a single photon which dominates the two-photon annihilation for B (10 to 13th power Gauss) The physics of these pair conversion processes, which is reviewed briefly, can become quite complex in the teragauss regime, and can involve calculations which are technically difficult to incorporate into models of emission mechanisms in neutron star magnetospheres. However, theoretical work, especially the case of pair annihilation, also suggests potential techniques for more direct measurements of field strengths near the stellar surface.

Daugherty, J. K.↗

THE HIGH-ENERGY EMISSION OF THE CRAB NEBULA FROM 20 keV TO 6 MeV WITH INTEGRAL SPI

The SPI spectrometer aboard the International Gamma-Ray Astrophysics Laboratory mission regularly observes the Crab Nebula since 2003. We report on observations distributed over 5.5 years and investigate the variability of the intensity and spectral shape of this remarkable source in the hard X-rays domain up to a few MeV. While single power-law models give a good description in the X-ray domain (mean photon index approx 2.05) and MeV domain (photon index approx 2.23), crucial information is contained in the evolution of the slope with energy between these two values. This study has been carried out through individual observations and long duration (approx 400 ks) averaged spectra. The stability of the emission is remarkable and excludes a single power-law model. The slopes measured below and above 100 keV agree perfectly with the last values reported in the X-ray and MeV regions, respectively, but without indication of a localized break point. This suggests a gradual softening in the emission around 100 keV and thus a continuous evolution rather than an actual change in the mechanism parameters. In the MeV region, no significant deviation from the proposed power-law model is visible up to 5-6 MeV. Finally, we take advantage of the spectroscopic capability of the instrument to seek for previously reported spectral features in the covered energy range with negative results for any significant cyclotron or annihilation emission on 400 ks timescales. Beyond the scientific results, the performance and reliability of the SPI instrument is explicitly demonstrated, with some details about the most appropriate analysis method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduction of spectral interferences and noise effects in laser ablation molecular isotopic spectrometry with partial least square regression – a computer simulation study

The fundamental analytical accuracies and precisions attainable by laser ablation molecular isotopic spectrometry (LAMIS), with emphasis on the impacts from spectral interferences and measurement noise, were investigated by means of computer simulation. The study focused on the analysis of a minor isotope at sub- to single-percentage abundance level. With a natural abundance about 1.1% for 13 C, the C 2 Swan band (d 3 II g - a 3 II u ) with Δν = + 1 was selected as a representative system. The characteristics (e.g., noise amplitude and distribution, signal strength, and signal-to-background ratio) of the simulated spectra were experimentally characterized. Partial least square (PLS) regression was used to extract isotopic information from the simulated molecular spectra. In the absence of any spectral interference and with the use of a calibration set consisting of eleven isotopic standards, the theoretical accuracies and precisions with signal accumulation from 100 laser shots are about 0.002% and 0.001%, respectively, in absolute percentage abundance of 13 C. The theoretical analytical accuracies slightly degrade, but are adequate for many applications, to 0.004% and 0.008% respectively, for calibrations involving only three and two isotopic standards. It was found that PLS regression is not only immune to both source-flicker and photon-shot noise, but is also effective in differentiating the spectral patterns from the analyte against those from spectral interferences. The influences of spectral interference from single or multiple atomic emission lines were simulated, and new ways to minimize their impacts were formulated and demonstrated. It was found that the wavelength range selected for the computation of the normalization factor should not contain any spectral-interfering peak, and a properly chosen wavelength range increases the tolerance of spectral interference by at least one order of magnitude. With matrix-matched calibration standards, the precisions (expressed as RSDs of the determined 13 C isotopic abundances) degrade from ~ 1% in the absence of spectral interference, to ~ 3&#8240, 10&#8240 and 20&#8240 with multiple spectral-interfering peaks that are 10 ×, 100 × and 1000 ×, respectively, stronger than the molecular bandhead of the analyte. The study concluded that PLS regression is a powerful and indispensable tool for extraction of isotopic information from LAMIS spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-F-18A-09: CT Number Stability Across Patient Sizes Using Virtual-Monoenergetic Dual-Energy CT

Purpose: Virtual-monoenergetic imaging uses dual-energy CT data to synthesize images corresponding to a single photon energy, thereby reducing beam-hardening artifacts. This work evaluated the ability of a commercial virtual-monoenergetic algorithm to achieve stable CT numbers across patient sizes. Methods: Test objects containing a range of iodine and calcium hydroxyapatite concentrations were placed inside 8 torso-shaped water phantoms, ranging in lateral width from 15 to 50 cm, and scanned on a dual-source CT system (Siemens Somatom Force). Single-energy scans were acquired from 70-150 kV in 10 kV increments; dual-energy scans were acquired using 4 energy pairs (low energy: 70, 80, 90, and 100 kV; high energy: 150 kV + 0.6 mm Sn). CTDIvol was matched for all single- and dual-energy scans for a given phantom size. All scans used 128×0.6 mm collimation and were reconstructed with 1-mm thickness at 0.8-mm increment and a medium smooth body kernel. Monoenergetic images were generated using commercial software (syngo Via Dual Energy, VA30). Iodine contrast was calculated as the difference in mean iodine and water CT numbers from respective regions-of-interest in 10 consecutive images. Results: CT numbers remained stable as phantom width varied from 15 to 50 cm for all dual-energy data sets (except for at 50 cm using 70/150Sn due to photon starvation effects). Relative to the 15 cm phantom, iodine contrast was within 5.2% of the 70 keV value for phantom sizes up to 45 cm. At 90/150Sn, photon starvation did not occur at 50 cm, and iodine contrast in the 50-cm phantom was within 1.4% of the 15-cm phantom. Conclusion: Monoenergetic imaging, as implemented in the evaluated commercial system, eliminated the variation in CT numbers due to patient size, and may provide more accurate data for quantitative tasks, including radiation therapy treatment planning. Siemens Healthcare.

07 ISOTOPE AND RADIATION SOURCES↗

A Simple and Portable Multi-Channel Pyrometer allowing temperature measurements down to 800 K on the microsecond scale

The measurement of transient temperatures less than 1000 K for samples in laser-heated diamond anvil cells remains a challenge. Here we present a design and performance characteristics for a multi-channel pyrometer that works in the NIR from 1200 to 2000 nm. It has a relatively small footprint, is portable, only requires low voltage power supplies and can report temperatures down to 800 K on the millisecond scale or faster. A single data point without averaging can be acquired in 14 microseconds (sampling rate of 70'000 times/s). In conjunction with a diamond anvil cell, the system still works down to about 830 K. The pyrometer has been interfaced several times with the laser heating system at the High Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source in Chicago with good results.

Montgomery, Jeffrey M.↗

Photoionization of tungsten ions: experiment and theory for ${{\rm{W}}}^{2+}$ and ${{\rm{W}}}^{3+}$

Experimental and theoretical results are reported for single-photon single ionization of W 2+ and W 3+ tungsten ions. Experiments were performed at the photon-ion merged-beam setup of the Advanced Light Source in Berkeley. Absolute cross sections and detailed energy scans were measured over an energy range 20-90 eV at a bandwidth of 100 meV. Broad peak features with widths typically around 5 eV have been observed with almost no narrow resonances present in the investigated energy range. Theoretical results were obtained from a Dirac-Coulomb R-matrix approach. The calculations were carried out for the lowest-energy terms of the investigated tungsten ions with levels 5s 2 5p 6 5d 4 5 D J J = 0, 1, 2, 3, 4 for W 2+ and 5s 2 5p 6 5d 3 4 F J ' J ' = 3/2, 5/2, 7/2, 9/2 for W 3+ . Assuming a statistically weighted distribution of ions in the initial ground-term levels there is good agreement of theory and experiment for W 3+ ions. However, for W 2+ ions at higher energies there is a factor of approximately two difference between experimental and theoretical cross sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trace: a high-throughput tomographic reconstruction engine for large-scale datasets

Abstract Background Modern synchrotron light sources and detectors produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used imaging techniques that generates data at tens of gigabytes per second is computed tomography (CT). Although CT experiments result in rapid data generation, the analysis and reconstruction of the collected data may require hours or even days of computation time with a medium-sized workstation, which hinders the scientific progress that relies on the results of analysis. Methods We present Trace, a data-intensive computing engine that we have developed to enable high-performance implementation of iterative tomographic reconstruction algorithms for parallel computers. Trace provides fine-grained reconstruction of tomography datasets using both (thread-level) shared memory and (process-level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations that we apply to the replicated reconstruction objects and evaluate them using tomography datasets collected at the Advanced Photon Source. Results Our experimental evaluations show that our optimizations and parallelization techniques can provide 158× speedup using 32 compute nodes (384 cores) over a single-core configuration and decrease the end-to-end processing time of a large sinogram (with 4501 × 1 × 22,400 dimensions) from 12.5 h to <5 min per iteration. Conclusion The proposed tomographic reconstruction engine can efficiently process large-scale tomographic data using many compute nodes and minimize reconstruction times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Measurements of Fuel Spray Specific Surface Area and Sauter Mean Diameter for Cavitating and Non-Cavitating Diesel Sprays

Specific surface area measurements of diesel sprays were performed using ultra-small-angle x-ray scattering at the 9-ID beamline of the Advanced Photon Source at Argonne National Laboratory. Injector orifice type, rail pressure, and ambient pressure effects were explored. The targeted sprays were created by three different single-hole nozzles fitted with duplicate light-duty common rail diesel injector bodies. One of the nozzles has been designed to cavitate under typical diesel operating conditions, while the other two nozzles are its non-cavitating analogues with nominally identical geometries. Measurements were conducted in the near-nozzle region along the spray axis as well as across the width of the jet. These data provide information with regard to not only the rate of shear-driven atomization, but also the radial dispersion of the fuel droplets at each of the measured conditions. In addition, when coupled with complementary measurements of the projected density, the data quantify the Sauter mean diameter of the fuel droplets in the probe volume. Here, these specific surface area and Sauter mean diameter measurements can be used to inform computational models of spray breakup that rely on droplet information in the near-nozzle region, where optical diagnostics have proven challenging.

47 OTHER INSTRUMENTATION↗

Canted Undulator Upgrade for GeoSoilEnviroCARS Sector 13 at the Advanced Photon Source

Support for the beamline component of the canted undulator upgrade of Sector 13 (GeoSoilEnviroCARS; managed and operated by the University of Chicago) at the Advanced Photon Source (APS; Argonne National Laboratory) was received from three agencies (equally divided): NASA-SRLIDAP (now LARS), NSF-EAR-IF (ARRA) and DOE-Single Investigator Small Group (SISGR). The associated accelerator components (undulators, canted front end) were provided by the APS using DOE-ARRA funding. The intellectual merit of the research enabled by the upgrade lies in advancing our knowledge of the composition, structure and properties of earth materials; the processes they control; and the processes that produce them. The upgrade will facilitate scientific advances in the following areas: high pressure mineral physics and chemistry, non-crystalline and nano-crystalline materials at high pressure, chemistry of hydrothermal fluids, reactions at mineral-water interfaces, biogeochemistry, oxidation states of magmas, flow dynamics of fluids and solids, and cosmochemistry. The upgrade, allowing the microprobe to operate 100% of the time and the high pressure and surface scattering and spectroscopy instruments to receive beam time increases, will facilitate much more efficient use of the substantial investment in these instruments. The broad scientific community will benefit by the increase in the number of scientists who conduct cutting-edge research at GSECARS. The user program in stations 13ID-C (interface scattering) and 13ID-D (laser heated diamond anvil cell and large volume press) recommenced in June 2012. The operation of the 13ID-E microprobe station began in the Fall 2012 cycle (Oct.-Dec 2012). The upgraded canted beamlines double the amount of undulator beam time at Sector 13 and provide new capabilities including extended operations of the X-ray microprobe down to the sulfur K edge and enhanced brightness at high energy. The availability of the upgraded beamlines will advance the research being conducted at Sector 13.

47 OTHER INSTRUMENTATION↗

Quantum-Well Thermophotovoltaic Cells

Thermophotovoltaic cells containing multiple quantum wells have been invented as improved means of conversion of thermal to electrical energy. The semiconductor bandgaps of the quantum wells can be tailored to be narrower than those of prior thermophotovoltaic cells, thereby enabling the cells to convert energy from longer-wavelength photons that dominate the infrared-rich spectra of typical thermal sources with which these cells would be used. Moreover, in comparison with a conventional single-junction thermophotovoltaic cell, a cell containing multiple narrow-bandgap quantum wells according to the invention can convert energy from a wider range of wavelengths. Hence, the invention increases the achievable thermal-to-electrical energy-conversion efficiency. These thermophotovoltaic cells are expected to be especially useful for extracting electrical energy from combustion, waste-heat, and nuclear sources having temperatures in the approximate range from 1,000 to 1,500 C.

Freudlich, Alex↗

Quantum Hamiltonian for the surface charge density on a ring torus and radiative decay of plasmons

Photon scattering and the ensuing excitation of surface plasmons in single rings, single composite rings, and many-ring systems was recently shown to provide dispersion and field distributions [K. V. Garapati et al., J. Phys. Commun. 2, 015031 (2018)] of potential for specific applications in particle and molecular trapping [R. Alaee et al., Appl. Phys. Lett. 109, 141102 (2016); M. Salhi et al., Phys. Rev. A 92, 033416 (2015)], in addition to metamaterials and sensing. Furthermore, following photon or electron interactions with metallic nanorings, both radiative and nonradiative decay channels are important in the consideration of the nanoparticle as a photon or phonon source, and in related applications. In this work, we quantize the electronic normal modes of the ring torus and obtain the radiative decay of plasmons. Due to a geometry-related complexity, we employ a perturbation approach to obtain analytical expressions for the radiative decay channel for a vacuum bounded single solid nanoring. In quantizing the fields, the frequency spectrum of the charge density normal modes of the nanoring is obtained and shown to agree with the exact quasistatic plasmon dispersion relations. Higher-order corrections beyond the presented zero- and first-order calculations may be obtained following the presented results. The results are of potential interest in quantum sensing such as entangling photons and plasmons, or plasmons and trapped molecules.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗