Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid-state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Thermal effects of insolation propagation into the regoliths of airless bodies

The planetary surface thermal models used in the present study are composed of particles which, while bright and optically thin in the visual, are dark and opaque in the thermal IR. It is assumed that insolation is absorbed over a finite regolith distance whose scale length relative to diurnal skin depth for thermal diffusion can be substantial. Attention is given to the lower daytime and higher nighttime temperatures predicted by comparison with models assuming absorption only at the surface. It is noted that, with sufficiently deep penetration of insulation and high thermal IR particle opacity, a solid-state greenhouse can result.

Brown, Robert Hamilton↗

Phase equilibria in the iron oxide-cobalt oxide-phosphorus oxide system

Two novel ternary compounds are noted in the present study of 1000 C solid-state equilibria in the Fe-Co-P-O system's Fe2O3-FePO4-Co3(Po4)2-CoO region: CoFe(PO4)O, which undergoes incongruent melting at 1130 C, and Co3Fe4(PO4)6, whose incongruent melting occurs at 1080 C. The liquidus behavior-related consequences of rapidly solidified cobalt ferrite formation from cobalt ferrite-phosphate melts are discussed with a view to spinel formation. It is suggested that quenching from within the spinel-plus-liquid region may furnish an alternative to quenching a homogeneous melt.

De Guire, Mark R.↗

A solid state laser development program for remote atmospheric sensors

The current status of NASA Langley efforts to develop solid-state lasers for use in the Lidar Atmospheric Sounder and Altimeter (LASA) of the Space Station Earth Observing System is surveyed. The types of observations to be performed with LASA are listed, and the parameters of presently available lasers are compared with the LASA baseline goals: 2 kW output power; 500 kg weight; tunability to 727, 760, and 943 nm to within 500 fm; high spectral purity; efficiency greater than 3 percent; energy about 1 J/pulse, pulse length less than 100 nsec, and lifetime greater than 108 shots. The use of sensitized flashlamp-pumped laser materials or diode-laser pumping to improve performance is discussed, and particular attention is given to materials research on Ti:sapphire lasers, studies of higher-efficiency detectors, and the LASE and LITE airborne lidar and DIAL experiments.

Newcomb, A. L.↗

A digital video model deformation system

The use of solid-state array cameras and a PC-controlled image acquisition system to measure model deformation in a wind tunnel is discussed. This digital system improves an earlier video model deformation system that used high-resolution tube cameras and required the manual measurement of targets on video hardcopy images. The new system eliminates both the vibration-induced distortion associated with tube cameras and the manual readup of video images necessary in the earlier version. Camera calibration and data reduction procedures necessary to convert pixel image plane data from two cameras into wing deflections are presented. Laboratory tests to establish the uncertainty of the system with the geometry to be used are described.

Burner, A. W.↗

Semiconductor lasers for space sensor applications

Despite their intrinsic power limitations, semiconductor laser diodes are essential for laser-based spaceborne sensor systems covering a wide spectral range, fulfilling such roles as pumping and injection-locking. They may also be used as direct sources in shorter-range operations. AlGaAs laser arrays have been developed for 810-nm band pumping in Nd:YAG lasers otherwise emitting at 1.064 nm. Additional roles include their use as low-power injection seeds, locking a solid-state laser into a specific desired wavelength.

Katz, Joseph↗

Stable-relaxation-oscillation Nd lasers for long-pulse generation

A simple method to produce high-energy neodymium (Nd) laser pulses with durations on the order of 1 microsec is described. Solid-state lasers can be pumped by relatively short flashlamp pulses to produce well-behaved relaxation oscillations in a diffraction-limited beam. Under the right conditons, each output laser pulse consists of a series of discrete subpulses that are ideally suited to efficient, high-energy amplification. Experimental results for an Nd:LiYF4 oscillator/amplifier system are presented along with numerical simulations. These demonstrate that the system operation is predictable and well behaved. Data are also included for a Nd:glass tunable oscillator based on this concept.

Harrison, James↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

Performance of efficient Q-switched diode-laser-pumped Nd:YAG and Ho:YLF lasers for space applications

Solid-state lasers pumped by continuous-wave diode lasers can be Q-switched to obtain high peak power output pulses. The dependence of laser-pulse energy, average output power, peak power, and pulse width on pulse-repetition frequency in Q-switched Nd:YAG and Ho:YLF lasers is determined and compared. At low pulse repetition rates, the much longer upper-stage lifetime in Ho:YLF gives a distinct advantage. At higher pulse rates, the overall laser efficiency and the stimulated emission cross section are more important parameters, leading to an advantage for Nd:YAG. The results are of significance for designing lasers for use in space optical communications and remote sensing systems.

Marshall, W. K.↗

Advanced solidstate array spectroradiometer - Sensor and calibration improvements

The advanced solid-state array spectroradiometer (ASAS), an airborne imaging spectrometer with 30 spectral channels extending from 450-880 nm, is described. Modifications to the sensor mounting technique changed the ASAS from a fixed nadir viewing instrument to a sensor capable of multiple direction observations of surface bidirectional reflectance distribution functions. The system was flown on the NASA Ames C130 aircraft to obtain surface bidirectional reflectance measurements of vegetation; it demonstrated excellent reliability and radiometric stability.

Huegel, Frederick G.↗

Spectroscopic analysis of insulating crystal fibers

A new technique is described for investigating the optical properties of solid-state laser materials using single-crystal fibers grown by a laser-heated pedestal-growth technique. Single-crystal fiber samples can be prepared more rapidly and less expensively than crystals grown by more conventional methods; however, they are smaller and less uniform, making spectroscopic measurements difficult. A simple procedure for extracting the optical absorption and emission spectra of insulating crystal fibers is demonstrated with a titanium-doped sapphire fiber sample; results are comparable to those from Czochralski-grown material.

Buoncristiani, A. M.↗

Monolithic watt-level millimeter-wave diode-grid frequency tripler array

In order to provide watt-level CW output power throughout the millimeter and submillimeter wave region, thousands of solid-state diodes have been monolithically integrated using a metal grid to produce a highly efficient frequency multiplier. Devices considered include GaAs Schottky diodes, thin MOS diodes, and GaAs Barrier-Intrinsic-N(+)diodes. The performance of the present compact low-cost device has been theoretically and experimentally validated.

Hwu, R. J.↗

Observation of an Excess Current Noise Resulting from Oxygen Absorption onto Iron Films

This paper reports on measurements that demonstrate that oxygen absorbed on clean polycrystalline Fe films can produce an excess current noise. The noise is indicative of dynamic processes occurring in the surface region of the film. We propose that the noise results from the dynamics of a reversible reaction between absorbed states. The measurements are accurately modeled with a single correlation time implying that surface heterogeneity is not important to the reaction. In addition to offering promise for future states of solid-state surface reactions, these measurements also have implications for the origin of 1/f current noise in conductors.

Shanabarger, M. R.↗

Pressure Measurement

Pressure Systems, Inc.'s DPT 6400 is a system designed to increase productivity in industrial processes where there is a need for making multiple pressure measurements quickly and with high accuracy. It is applicable in controlling industrial processes in plants that are being upgraded to automated status. In order to automate such plants the pressures at the many loops must be measured, converted to digital information and transmitted to the plant's process control computer. The DPT 6400 serves that function. By employing solid-state pressure sensing transducers whose errors are automatically corrected by a microprocessor, it is capable of highly accurate pressure measurements. Basic DPT 6400 has 64 channels, but the system can be expanded to 256 channels by the addition of "slave" units.

Source record↗

Emergency/Night Lightning

UDEC's highly efficient lighting system is finding wide acceptance among industrial and commercial firms as an energy savings means of providing emergency and night lighting. Originating from Skylab, the system consists of small high frequency fluorescent light fixtures powered by solar cells. Advantages of UDEC's lighting system stem from high reliability and high light output with very low energy drain. Principal components of system are long life fluorescent lamps operated by electronic circuitry, a sealed gelatine cell battery that needs no maintenance for eight years and a solid-state automatic battery charger. Installation of UDEC lighting in a company's six-and-a-half acre warehouse office cut the annual night lighting electric bill from $8,000 a year to $300 per year.

Source record↗

Emergency Lighting

A lighting system originally developed for NASA's Apollo and Skylab manned spacecraft resulted in a industrial spinoff and creation of a whole new company to produce and market the product line. The company is UDEC Corp., Waltham, Mass. UDEC's "Multi-Mode" electronic lighting systems are designed for plant emergency and supplemental use, such as night lighting, "always-on" stairwell lights and illuminated exit signs. Their advantages stem from the qualities demanded for spacecraft installation: extremely high fight output with very low energy drain, compactness, light weight, and high reliability. The Multi-Mode system includes long-life fluorescent lamps operated by electronic circuitry, a sealed battery that needs no maintenance for 10 years, and a solid-state battery charger. A typical emergency installation consists of a master module with battery and an eight watt lamp, together with four remote "Satellight" modules powered by the master's battery. As a night lighting system for maintenance or I security, UDEC fixtures can bypass the battery and 1 operate on normal current at a fraction of the energy 1 demand of conventional night lighting. Industrial customers have realized savings of better than ninety percent with UDEC night lights. UDEC started as a basement industry in 1972 but the company has already sold more than 1,000 lighting systems to building operators.

Source record↗

Breadboard Facility

In the sixties, Chrysler was NASA's prime contractor for the Saturn I and IB test launch vehicles. The company installed and operated at Huntsville what was known as the Saturn I/IB Development Breadboard Facility. "Breadboard," means an array of electrical and electronic equipment for performing a variety of development and test functions. This work gave Chrysler a broad capability in computerized testing to assure quality control in development of solid-state electronic systems. Today that division is manufacturing many products not destined for NASA, most of them being associated with the company's automotive line. A major project is production and quality-control testing of the "lean-burn" engine, one that has a built-in Computer to control emission timing, and allow the engine to run on a leaner mixture of fuel and air. Other environment-related products include vehicle emission analyzers. The newest of the line is an accurate, portable solid state instrument for testing auto exhaust gases. The exhaust analyzers, now being produced for company dealers and for service

Source record↗