Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Advanced X-ray Astrophysics Facility (AXAF) science instruments

The overall AXAF program is summarized, with particular emphasis given to its science instruments. The science objectives established for AXAF are to determine the nature of celestial objects, from normal stars to quasars, to elucidate the nature of the physical processes which take place in and between astronomical objects, and to shed light on the history and evolution of the universe. Attention is given to the AXAF CCD imaging spectrometer, which is to provide spectrally and temporally resolved imaging, or, in conjunction with transmission grating, high-resolution dispersed spectral images of celestial sources. A high-resolution camera, an X-ray spectrometer, and the Bragg Crystal Spectrometer are also discussed.

Winkler, Carl E.↗

Image sharpening for mixed spatial and spectral resolution satellite systems

Two methods of image sharpening (reconstruction) are compared. The first, a spatial filtering technique, extrapolates edge information from a high spatial resolution panchromatic band at 10 meters and adds it to the low spatial resolution narrow spectral bands. The second method, a color normalizing technique, is based on the ability to separate image hue and brightness components in spectral data. Using both techniques, multispectral images are sharpened from 30, 50, 70, and 90 meter resolutions. Error rates are calculated for the two methods and all sharpened resolutions. The results indicate that the color normalizing method is superior to the spatial filtering technique.

Hallada, W. A.↗

GIFTS SM EDU Radiometric and Spectral Calibrations

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

Tian, J.↗

Automatic method of material identification for computed tomography

A method is provided for isolating and labeling discrete features in a spectral radiographic image recorded as a set of images in different energy channels. The disclosed method involves creating a profile for each of at least some pixels in the spectral radiographic image. The profiles are sequences of pixel values, in which each pixel value is a photon count or a similar radiographic exposure value indicative of the attenuation of a portion of the scanning beam in a respective energy channel. Iterative hierarchical clustering is used to cluster the pixels on the basis of their respective profiles. Labels are assigned to one or more of the resulting clusters. In implementations, each label can be associated with an inferred material composition or with an inference that the material composition is unknown.

Jimenez, Jr., Edward Steven↗

Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

Vane, Gregg↗

Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

Vane, Gregg↗

Single-lens computed tomography imaging spectrometer and method of capturing spatial and spectral information

Computed tomography imaging spectrometers ("CTISs") employing a single lens are provided. The CTISs may be either transmissive or reflective, and the single lens is either configured to transmit and receive uncollimated light (in transmissive systems), or is configured to reflect and receive uncollimated light (in reflective systems). An exemplary transmissive CTIS includes a focal plane array detector, a single lens configured to transmit and receive uncollimated light, a two-dimensional grating, and a field stop aperture. An exemplary reflective CTIS includes a focal plane array detector, a single mirror configured to reflect and receive uncollimated light, a two-dimensional grating, and a field stop aperture.

Wilson, Daniel W.↗

IPL Processing of the Viking Orbiter Images of Mars

The Viking orbiter cameras returned over 9000 images of Mars during the 6-month nominal mission. Digital image processing was required to produce products suitable for quantitative and qualitative scientific interpretation. Processing included the production of surface elevation data using computer stereophotogrammetric techniques, crater classification based on geomorphological characteristics, and the generation of color products using multiple black-and-white images recorded through spectral filters. The Image Processing Laboratory of the Jet Propulsion Laboratory was responsible for the design, development, and application of the software required to produce these 'second-order' products.

Ruiz, R. M.↗

Remote sensing of canopy chemistry and nitrogen cycling in temperate forest ecosystems

The use of images acquired by the Airborne Imaging Spectrometer, an experimental high-spectral resolution imaging sensor developed by NASA, to estimate the lignin concentration of whole forest canopies in Wisconsin is reported. The observed strong relationship between canopy lignin concentration and nitrogen availability in seven undisturbed forest ecosystems on Blackhawk Island, Wisconsin, suggests that canopy lignin may serve as an index for site nitrogen status. This predictive relationship presents the opportunity to estimate nitrogen-cycling rates across forested landscapes through remote sensing.

Wessman, Carol A.↗

Astronomical data analysis software and systems I; Proceedings of the 1st Annual Conference, Tucson, AZ, Nov. 6-8, 1991

Consideration is given to a definition of a distribution format for X-ray data, the Einstein on-line system, the NASA/IPAC extragalactic database, COBE astronomical databases, Cosmic Background Explorer astronomical databases, the ADAM software environment, the Groningen Image Processing System, search for a common data model for astronomical data analysis systems, deconvolution for real and synthetic apertures, pitfalls in image reconstruction, a direct method for spectral and image restoration, and a discription of a Poisson imagery super resolution algorithm. Also discussed are multivariate statistics on HI and IRAS images, a faint object classification using neural networks, a matched filter for improving SNR of radio maps, automated aperture photometry of CCD images, interactive graphics interpreter, the ROSAT extreme ultra-violet sky survey, a quantitative study of optimal extraction, an automated analysis of spectra, applications of synthetic photometry, an algorithm for extra-solar planet system detection and data reduction facilities for the William Herschel telescope.

Worrall, Diana M.↗

Plasma Treatment to Remove Carbon from Indium UV Filters

The sounding rocket experiment FIRE (Far-ultraviolet Imaging Rocket Experiment) will improve the science community fs ability to image a spectral region hitherto unexplored astronomically. The imaging band of FIRE (.900 to 1,100 Angstroms) will help fill the current wavelength imaging observation hole existing from approximately equal to 620 Angstroms to the GALEX band near 1,350 Angstroms. FIRE is a single-optic prime focus telescope with a 1.75-m focal length. The bandpass of 900 to 1100 Angstroms is set by a combination of the mirror coating, the indium filter in front of the detector, and the salt coating on the front of the detector fs microchannel plates. Critical to this is the indium filter that must reduce the flux from Lymanalpha at 1,216 Angstroms by a minimum factor of 10(exp -4). The cost of this Lyman-alpha removal is that the filter is not fully transparent at the desired wavelengths of 900 to 1,100 Angstroms. Recently, in a project to improve the performance of optical and solar blind detectors, JPL developed a plasma process capable of removing carbon contamination from indium metal. In this work, a low-power, low-temperature hydrogen plasma reacts with the carbon contaminants in the indium to form methane, but leaves the indium metal surface undisturbed. This process was recently tested in a proof-of-concept experiment with a filter provided by the University of Colorado. This initial test on a test filter showed improvement in transmission from 7 to 9 percent near 900 with no process optimization applied. Further improvements in this performance were readily achieved to bring the total transmission to 12% with optimization to JPL's existing process.

Greer, Harold F.↗

Airborne Remote Sensing for Earth Science Applications

Topics covered include: Passive Remote Sensing Methods, Imaging Spectroscopy Approach, Remote Measurement via Spectral Fitting, Imaging Spectroscopy Mapping Wetland Dominants 2010 LA (AVIRIS), Deepwater Horizon Response I, Deepwater Horizon Response II, AVIRIS Ocean Color Studies.

AVIRIS: Airborne Imaging Spectrometer↗

The Focal Plane Assembly for the Athena X-Ray Integral Field Unit Instrument

This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off-line coincidence detection to identify and reject events caused by the in-orbit high-energy particle background. The detectors, operating at 55 mK, or less, will be thermally isolated from the instrument cryostat's 2 K stage, while shielding and filtering within the FPA will allow the instrument's sensitive sensor array to be operated in the expected environment during both on-ground testing and in-flight operation, including stray light from the cryostat environment, low-energy photons entering through the X-ray aperture, low-frequency magnetic fields, and high-frequency electric fields.

SQUID amplifier↗

Pan-sharpening for microscopy

Techniques for generating full-spatial resolution, full spectral resolution image(s) from a 3D spectral-data cube for any spectral value within a given spectral range are provided without requiring the acquisition of all full-spatial resolution, full spectral resolution data by an instrument. The 3D spectral-data cube is generated from a limited number of full-spatial resolution, sparse spectral resolution data and a sparse-spatial resolution, full-spectral resolution data of the same area of the sample. The use of the 3D spectral-data cube reduces the data acquisition time.

Ovchinnikova, Olga S.↗

Vegetation species composition and canopy architecture information expressed in leaf water absorption measured in the 1000 nm and 2200 spectral region by an imaging spectrometer

Plant species composition and plant architectural attributes are critical parameters required for the measuring, monitoring, and modeling of terrestrial ecosystems. Remote sensing is commonly cited as an important tool for deriving vegetation properties at an appropriate scale for ecosystem studies, ranging from local to regional and even synoptic scales. Classical approaches rely on vegetation indices such as the normalized difference vegetation index (NDVI) to estimate biophysical parameters such as leaf area index or intercepted photosynthetically active radiation (IPAR). Another approach is to apply a variety of classification schemes to map vegetation and thus extrapolate fine-scale information about specific sites to larger areas of similar composition. Imaging spectrometry provides additional information that is not obtainable through broad-band sensors and that may provide improved inputs both to direct biophysical estimates as well as classification schemes. Some of this capability has been demonstrated through improved discrimination of vegetation, estimates of canopy biochemistry, and liquid water estimates from vegetation. We investigate further the potential of leaf water absorption estimated from Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data as a means for discriminating vegetation types and deriving canopy architectural information. We expand our analysis to incorporate liquid water estimates from two spectral regions, the 1000-nm region and the 2200-nm region. The study was conducted in the vicinity of Jasper Ridge, California, which is located on the San Francisco peninsula to the west of the Stanford University campus. AVIRIS data were acquired over Jasper Ridge, CA, on June 2, 1992, at 19:31 UTC. Spectra from three sites in this image were analyzed. These data are from an area of healthy grass, oak woodland, and redwood forest, respectively. For these analyses, the AVIRIS-measured upwelling radiance spectra for the entire Jasper Ridge scene were transformed to apparent surface reflectance using a radiative transfer code-based inversion algorithm.

Green, Robert O.↗

Tunable mid-wave infrared spectral filters based on GexSbyTez for multispectral imaging

The mid-wave infrared (MWIR) spectrum contains a wealth of invaluable information including the spectral ‘fingerprint’ of many chemical species and has applications in remote sensing and astronomical imaging. Traditionally, filtering for the MWIR is achieved by means of passive multilayer interference (dichroic) filters, Fabry-Perot-based micro-electro-mechanical system (MEMS) filters, liquid crystal tunable filters, and focal plane array (FPA) filters. For accurate multispectral imaging applications, these approaches suffer from various limitations such as: having moving parts; exhibiting slow response times, and; having limited spectral bandwidth / resolution. Recently, there has been significant interest toward ‘active’ spectral imaging technologies, whereby the ability to provide electrically tunable narrowband filtering—spanning the entire MWIR—is highly desirable. In this work we introduce a new spectral imaging technology, namely actively tunable optical transmission filters using the phase-change material (PCM) GexSbyTez (GST). The GST exhibits a large, reversible change in its refractive index across the MWIR upon a phase transition (from amorphous to crystalline). This refractive index modulation governs the filter’s optical characteristics. Through an optical stimulus or applied voltage—which changes the GST state from amorphous to crystalline—one can actively tune the filter with MHz speed. We incorporate GST into optimized guided mode resonance (GMR) and plasmonic nanohole array (PNA) device architectures, enabling <10nm spectral resolution and tunable operation across 3~5µm. Our proposed PCM-MWIR filter will be able to extract the maximum amount of ‘useful’ information within the atmosphere for remote Earth sensing measurements at operational speeds orders of magnitude faster than current airborne-based sensors. Moreover, it may enable affordable SmallSat-based MWIR instrumentation which is complimentary to other observation systems. The MISSE (Materials International Space Station Experiment-Flight Facility) experiment has been proposed as a testbed for a PCM-based tunable MWIR filter module to allow exposure of the module to the low Earth orbit space environment. This will provide valuable data regarding the robustness of the filter to withstand the radiation and atomic oxygen environment and allow assessment of the technology for use in space applications.

Kim, Hyun Jung↗

Quantitative subpixel spectral detection of targets in multispectral images

The conditions that affect the spectral detection of target materials at the subpixel scale are examined. Two levels of spectral mixture analysis for determining threshold detection limits of target materials in a spectral mixture are presented, the cases where the target is detected as: (1) a component of a spectral mixture (continuum threshold analysis) and (2) residuals (residual threshold analysis). The results of these two analyses are compared under various measurement conditions. The examples illustrate the general approach that can be used for evaluating the spectral detectability of terrestrial and planetary targets at the subpixel scale.

Sabol, Donald E., Jr.↗