Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Effect of storage and LEO cycling on manufacturing technology IPV nickel-hydrogen cells

Yardney Manufacturing Technology (MANTECH) 50 A-hr space weight individual pressure vessel nickel-hydrogen cells were evaluated. This consisted of investigating: the effect of storage and charge/discharge cycling on cell performance. For the storage test the cells were precharged with hydrogen, by the manufacturer, to a pressure of 14.5 psia. After undergoing activation and acceptance tests, the cells were discharged at C/10 rate (5A) to 0.1 V or less. The terminals were then shorted. The cells were shipped to NASA Lewis Research Center where they were stored at room temperature in the shorted condition for 1 year. After storage, the acceptance tests were repeated at NASA Lewis. A comparison of test results indicate no significant degradation in electrical performance due to 1 year storage. For the cycle life test the regime was a 90 minute low earth orbit at deep depths of discharge (80 and 60 percent). At the 80 percent DOD the three cells failed on the average at cycle 741. Failure for this test was defined to occur when the cell voltage degraded to 1 V prior to completion of the 35 min discharge. The DOD was reduced to 60 percent. The cycle life test was continued.

Smithrick, John J.↗

Effect of storage and LEO cycling on manufacturing technology IPV nickel-hydrogen cells

Yardney Manufacturing Technology (MANTECH) 50 A-hr space weight individual pressure vessel nickel-hydrogen cells were evaluated. This consisted of investigating: the effect of storage and charge/discharge cycling on cell performance. For the storage test the cells were precharged with hydrogen, by the manufacturer, to a pressure of 14.5 psia. After undergoing activation and acceptance tests, the cells were discharged at C/10 rate (5A) to 0.1 V or less. The terminals were then shorted. The cells were shipped to NASA Lewis Research Center where they were stored at room temperature in the shorted condition for 1 year. After storage, the acceptance tests were repeated at NASA Lewis. A comparison of test results indicate no significant degradation in electrical performance due to 1 year storage. For the cycle life test the regime was a 90 minute low earth orbit at deep depths of discharge (80 and 60 percent). At the 80 percent DOD the three cells failed on the average at cycle 741. Failure for this test was defined to occur when the cell voltage degraded to 1 V prior to completion of the 35 min discharge. The DOD was reduced to 60 percent. The cycle life test was continued.

Smithrick, John J.↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗

Snohomish Public Utility District: An Assessment of Battery Technical Performance

This report investigates the technical performance of the SnoPUD MESA-1 BESS facility, consisting of two battery sub-systems 1a and 1b, based on a number of baseline and use case tests. Baseline tests were intended to assess the general technical capability of the BESS (e.g., stored energy capacity, ramp rate performance, ability to track variable charge/discharge commands, direct current (DC) battery internal resistance) while the use case tests were intended to examine the performance of the BESS while engaged in specific economic services (e.g., arbitrage, power factor correction).

25 ENERGY STORAGE↗

Lustre Unveiled: Evolution, Design, Advancements, and Current Trends

The Lustre filesystem serves as a vital element in high-performance parallel storage, meeting the rising demands of scientific, research, and enterprise environments. Widely deployed across HPC environments, ranging from small-scale applications in AI/ML, to domains like oil and gas, drug discovery, and meteorology, and manufacturing, Lustre addresses the universal challenge of efficiently accessing vast and ever-increasing volumes of data. Lustre is the filesystem of choice on six out of the top 10 fastest supercomputers in the world today, over 65% of the top 100, and also for over 60% of the top 500. Despite its widespread popularity, there is a lack of a complete and up-to-date reference, covering Lustre’s evolution, design, and various advancements made over the years. In this journal, we aim to fill this gap by providing a comprehensive journey of Lustre, including its history with significant contributions to HPC, detailed architecture and design elements, exploration of advancements added through its evolution, and future directions. Additionally, we present a comparison of Lustre with other prominent storage technologies of the era. To illustrate the current state of Lustre, we analyze several filesystem trends, including utilization, performance, and usage patterns on Orion, the Lustre filesystem on the first exascale supercomputer Frontier. We hope that this journal serves as a comprehensive educational reference for the current and future generations interested in HPC filesystem storage aspects.

97 MATHEMATICS AND COMPUTING↗

Uncovering I/O demands on HPC platforms: Peeking under the hood of Santos Dumont

High-Performance Computing (HPC) platforms are required to solve the most diverse large-scale scientific problems in various research areas, such as biology, chemistry, physics, and health sciences. Researchers use a multitude of scientific softwares, which have different requirements. These include input and output operations, which directly impact performance due to the existing difference in processing and data access speeds. Thus, supercomputers must efficiently handle mixed workload when storing data from the applications. Understanding the set of applications and their performance running in a supercomputer is paramount to understanding the storage system's usage, pinpointing possible bottlenecks, and guiding optimization techniques. This research proposes a methodology and visualization tool to evaluate a supercomputer's data storage infrastructure's performance, taking into account the diverse workload and demands of the system over a long period of operation. As a study case, we focus on the Santos Dumont supercomputer, identifying inefficient usage, problematic performance factors, and providing guidelines on how to tackle those issues.

97 MATHEMATICS AND COMPUTING↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Features, Events and Processes for the Used Fuel Disposition Campaign

The Used Fuel Disposition (UFD) Campaign within DOE-NE is evaluating storage and disposal options for a range of waste forms and a range of geologic environments. To assess the potential performance of conceptual repository designs for the combinations of waste form and geologic environment, a master set of Features, Events, and Processes (FEPs) has been developed and evaluated. These FEPs are based on prior lists developed by the Yucca Mountain Project (YMP) and the international repository community. The objective of the UFD FEPs activity is to identify and categorize FEPs that are important to disposal system performance for a variety of disposal alternatives (i.e., combinations of waste forms, disposal concepts, and geologic environments). FEP analysis provides guidance for the identification of (1) important considerations in disposal system design, and (2) gaps in the technical bases. The UFD FEPs also support the development of performance assessment (PA) models to evaluate the long-term performance of waste forms in the engineered and geologic environments of candidate disposal system alternatives. For the UFD FEP development, five waste form groups and seven geologic settings are being considered. A total of 208 FEPs have been identified, categorized by the physical components of the waste disposal system as well as cross-cutting physical phenomena. The combination of 35 waste-form/geologic environments and 208 FEPs is large; however, some FEP evaluations can cut across multiple waste/environment combinations, and other FEPs can be categorized as not-applicable for some waste/environment combinations, making the task of FEP evaluation more tractable. A FEP status tool has been developed to document progress. The tool emphasizes three major areas that can be statused numerically. FEP Applicability documents whether the FEP is pertinent to a waste/environment combination. FEP Completion Status documents the progress of the evaluation for the FEP/waste/environment combination. FEP Importance documents the potential importance for the FEP/waste/environment combination to repository performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lessons Learned in Deploying the World s Largest Scale Lustre File System

The Spider system at the Oak Ridge National Laboratory's Leadership Computing Facility (OLCF) is the world's largest scale Lustre parallel file system. Envisioned as a shared parallel file system capable of delivering both the bandwidth and capacity requirements of the OLCF's diverse computational environment, the project had a number of ambitious goals. To support the workloads of the OLCF's diverse computational platforms, the aggregate performance and storage capacity of Spider exceed that of our previously deployed systems by a factor of 6x - 240 GB/sec, and 17x - 10 Petabytes, respectively. Furthermore, Spider supports over 26,000 clients concurrently accessing the file system, which exceeds our previously deployed systems by nearly 4x. In addition to these scalability challenges, moving to a center-wide shared file system required dramatically improved resiliency and fault-tolerance mechanisms. This paper details our efforts in designing, deploying, and operating Spider. Through a phased approach of research and development, prototyping, deployment, and transition to operations, this work has resulted in a number of insights into large-scale parallel file system architectures, from both the design and the operational perspectives. We present in this paper our solutions to issues such as network congestion, performance baselining and evaluation, file system journaling overheads, and high availability in a system with tens of thousands of components. We also discuss areas of continued challenges, such as stressed metadata performance and the need for file system quality of service alongside with our efforts to address them. Finally, operational aspects of managing a system of this scale are discussed along with real-world data and observations.

99 GENERAL AND MISCELLANEOUS↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

Two-dimensional heterostructures for energy storage

Two-dimensional (2D) materials provide slit-shaped ion diffusion channels that enable fast movement of lithium and other ions. However, electronic conductivity, the number of intercalation sites, and stability during extended cycling are also crucial for building high-performance energy storage devices. While individual 2D materials, such as graphene, show some of the required properties, none of them can offer all properties needed to maximize energy density, power density, and cycle life. Here we argue that stacking different 2D materials into heterostructured architectures opens an opportunity to construct electrodes that would combine the advantages of the individual building blocks while eliminating the associated shortcomings. We discuss characteristics of common 2D materials and provide examples of 2D heterostructured electrodes that showed new phenomena leading to superior electrochemical performance. As a result, we also consider electrode fabrication approaches and finally outline future steps to create 2D heterostructured electrodes that could greatly expand current energy storage technologies.

25 ENERGY STORAGE↗

Hydrogen storage adsorbent systems acceptability envelope

A methodology was developed here to determine the range of coupled material parameters and operating conditions that allow an adsorbent based hydrogen storage system to meet performance targets. The range of acceptable parameters forms a multi-dimensional volume, or envelope. For this reason, the methodology is referred to as the Adsorbent Acceptability Envelope. The model evaluates the performance of the overall storage tank, comprised of the adsorbent material, the heat transfer system and the pressure vessel. Two cases were analyzed, both based on the flow-through cooling approach providing the cooling power required to charge hydrogen, with results presented and discussed. The first application (the forward problem) analyzed the gravimetric and volumetric performance of MOF-5 ® based hydrogen storage beds, under various operating conditions. Results demonstrated that the system can reach a gravimetric capacity of approximately 4 wt% and volumetric capacity of about 20 g/L within 200 s during the absorption process. The second application (the inverse problem) identified the range of selected material parameters, required to meet the U.S. Department of Energy targets for gravimetric and volumetric capacity. Results showed that the most important parameters are the maximum capacity and the density of the material. Adsorbents having a density on the order of twice that of nominal powder form MOF-5 ® can meet the 2020 DOE targets (i.e. system gravimetric capacity of 0.045 kg H2 /kg System and system volumetric capacity of 0.030 kg H2 /L System ). A density of about 3–4.5 times the nominal value is required to meet the DOE 2025 targets (i.e. system gravimetric capacity of 0.055 kg H2 /kg System and system volumetric capacity of 0.040 kg H2 /L System ). Likewise, a material with a maximum adsorption capacity approximately equal to three times that of nominal MOF-5 ® can meet the 2020 DOE targets, while a maximum capacity about 4.5 times the nominal value is required to meet the 2025 DOE targets.

08 HYDROGEN↗

An Efficient Storage-Driven Machine Learning Model for Performance in the Era of Multimodal Scientific Data

Scientific workflows are increasingly relying on machine learning (ML), simulation, and hybrid techniques to predict, understand, and optimize the behavior of complex experiments. High-performance computing has greatly improved researchers’ ability to acquire diverse data modalities in these workflows. Recent studies suggest that the performance of machine learning models can be improved by integrating data from various sources. Unfortunately, these workloads pose unprecedent pressure on the network storage to meet the demands associated with accessing these multimodal data. To mitigate the impact of intensive IO, we propose a solution that utilizes a multi-tier High-Performance Computing (HPC) distributed storage and data processing framework, placing computation where the data resides for better performance. By adopting this project, the scientific community will gain new opportunities to explore multimodal storage-driven possibilities, integrating multiple scientific data sources with advanced streaming frameworks. Additionally, our framework effectively utilizes computing resources and bridges the gaps identified by HPC experts. Our proposed approach tackles scalability and persistence challenges by leveraging native persistency, which has posed difficulties in traditional approaches. Furthermore, we seek to enhance fault-tolerance and load-balance of computations by leveraging real-time streaming in diverse scientific computing environments, thereby propelling advanced scientific computing research into the next generation.

97 MATHEMATICS AND COMPUTING↗

The SERI solar energy storage program

In support of the DOE thermal and chemical energy storage program, the solar energy storage program (SERI) provides research on advanced technologies, systems analyses, and assessments of thermal energy storage for solar applications in support of the Thermal and Chemical Energy Storage Program of the DOE Division of Energy Storage Systems. Currently, research is in progress on direct contact latent heat storage and thermochemical energy storage and transport. Systems analyses are being performed of thermal energy storage for solar thermal applications, and surveys and assessments are being prepared of thermal energy storage in solar applications. A ranking methodology for comparing thermal storage systems (performance and cost) is presented. Research in latent heat storage and thermochemical storage and transport is reported.

Copeland, R. J.↗

DuoModel: Leveraging Reduced Model for Data Reduction and Re-Computation on HPC Storage

High-performance computing (HPC) applications generate large amounts of floating-point data that need to be stored and analyzed efficiently to extract the insights and advance knowledge discovery. With the growing disparities between compute and I/O, optimizing the storage stack alone may not suffice to cure the I/O problem. There has been a strong push in the HPC communities to perform data reduction before data is transmitted to storage in order to lower the I/O cost. However, as of now, neither lossless nor lossy compressors can achieve the adequate reduction ratio that is desired by applications. This paper proposes DuoModel, a new approach that leverages the similarity between the full and reduced application models, and further improve the data reduction ratio. DouModel further improves the compression ratio of state-of-the-art compressors via compressing the differences (termed as delta) between the data products of the two models. For data analytics, the high fidelity data can be re-computed by launching the reduced model and applying the compressed delta. Our evaluations confirm that DuoModel can further push the limit of data reduction while the high fidelity of data is maintained.

Luo, Huizhang (ORCID:0000000323920267)↗

High performance network and channel-based storage

In the traditional mainframe-centered view of a computer system, storage devices are coupled to the system through complex hardware subsystems called input/output (I/O) channels. With the dramatic shift towards workstation-based computing, and its associated client/server model of computation, storage facilities are now found attached to file servers and distributed throughout the network. We discuss the underlying technology trends that are leading to high performance network-based storage, namely advances in networks, storage devices, and I/O controller and server architectures. We review several commercial systems and research prototypes that are leading to a new approach to high performance computing based on network-attached storage.

Katz, Randy H.↗