Search NASASearch

SEARCH · Search NASA

Results for “structural color”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

472 records · Page 27

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology

DESI 2024 II: sample definitions, characteristics, and two-point clustering statistics

We present the samples of galaxies and quasars used for DESI 2024 cosmological analyses, drawn from the DESI Data Release 1 (DR1). We describe the construction of largescale structure (LSS) catalogs from these samples, which include matched sets of synthetic reference ‘randoms’ and weights that account for variations in the observed density of the samples due to experimental design and varying instrument performance. We detail how we correct for variations in observational completeness, the input ‘target’ densities due to imaging systematics, and the ability to confidently measure redshifts from DESI spectra. We then summarize how remaining uncertainties in the corrections can be translated to systematic uncertainties for particular analyses. We describe the weights added to maximize the signalto-noise of DESI DR1 2-point clustering measurements. We detail measurement pipelines applied to the LSS catalogs that obtain 2-point clustering measurements in configuration and Fourier space. The resulting 2-point measurements depend on window functions and normalization constraints particular to each sample, and we present the corrections required to match models to the data. We compare the configuration- and Fourier-space 2-point clustering of the data samples to that recovered from simulations of DESI DR1 and find they are, generally, in statistical agreement to within 2% in the inferred real-space over-density field. The LSS catalogs, 2-point measurements, and their covariance matrices will be released publicly with DESI DR1.

79 ASTRONOMY AND ASTROPHYSICS

Influence of Powder Characteristics and Processing Methods on Creep Performance of Powder Metallurgy Hot Isostatic Pressed SS316

The U.S. nuclear energy expansion goals are driving the demand for manufacturing routes that can rapidly produce large, complex, near net shape components. Powder metallurgy hot isostatic pressing (PM HIP) is an advanced manufacturing technique that can be economically scaled-up, while alleviating the supply chain challenges that forging and casting face in terms of cost and lead time constraints. This makes PM-HIP a viable technology to aid and accelerate large-scale part manufacturing for nuclear applications. However, large-scale qualification and deployment of this technology require a thorough understanding of the influence of powder feedstock quality, powder handling history, hot isostatic pressing (HIP) parameters, and subsequent heat treatment on microstructural evolution and elevated temperature mechanical performance. The present work focusses on 316 austenitic stainless steel (SS316) which is most commonly used in high temperature environments for nuclear applications Results from this study show that PM HIPed SS316 meets ASME tensile requirements at room temperature and at elevated temperature. However, creep performance of PM-HIPed SS316 remains inferior to its wrought counterpart, demonstrating that tensile performance alone is not a reliable metric for long duration high temperature integrity. Further, this report delineates powder derived microstructural features that govern creep damage, with key evidences pointing to “microstructural inheritance” from gas atomized powder feedstocks. Commercial SS316 powders of varying chemical compositions and recycling histories were studies, and the results showed large differences in elemental segregation, oxide surface layers and secondary phase distributions. Multi-scale characterization revealed segregation of chromium, molybdenum, manganese and silicon at the boundaries and the precipitation of manganese-, silicon-, and molybdenum-oxides. During HIP consolidation, these surface oxides transform into decorated prior particle boundaries (PPBs) and grain boundary inclusions that persist through conventional post-HIP solution annealing treatment. The retained oxides in post-HIP microstructures were found to influence grain growth, precipitation behavior, and ultimately creep cavitation and fracture. Such post-HIP heat treatments are therefore limited by a complex trade-off between grain growth, and oxide coarsening which aggravate creep damage by acting as nucleation sites for cavities. The objective of this work is to establish an integrated processing–structure–property framework for PM-HIP 316 stainless steel by investigating the influence of powder feedstock characteristics in pre- and post-HIP processing as well as to understand the significance of post-HIP heat treatment on microstructural evolution and creep properties. The results from this report emphasize the significance of powder feedstock integrity in improving creep performance of PM-HIPed SS316, by highlight the effect of rapid solidification, elemental segregation, oxide formation and powder recycling on microstructural defect inheritance following HIP consolidation. Rather than considering HIP processing, solution annealing, and mechanical performance independently, this report treats powder production, HIP consolidation, post-HIP thermal processing, and creep deformation as interconnected stages within a continuous metallurgical process. The resulting framework will provide a scientific basis for developing feedstock engineering strategies capable of improving long-term reliability of PM-HIP stainless steels and accelerating their qualification for advanced nuclear applications.

Ajjarapu, Pavan [Oak Ridge National Laboratory (OR

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science