Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Large-scale structure effects on the gravitational lens image positions and time delay

We compute the fluctuations in gravitational lens image positions and time delay caused by large-scale structure correlations. We show that these fluctuations can be expressed as a simple integral over the density power spectrum. Using the Cosmic Background Explorer (COBE) normalization we find that positions of objects at cosmological distances are expected to deviate from their true positions by few arcminutes. These deflections are not directly observable. The positions of the images relative to one another fluctuate by a few percent of the relative separation, implying that one does not expect multiple images to be produced by large-scale structure. Nevertheless, the fluctuations are larger than the observational errors on the positions and affect reconstructions of the lens potential. The time delay fluctuations have a geometrical and a gravitational contribution. Both are much larger than the expected time delay from the primary lens, but partially cancel each other. We find that large-scale structure weakly affects the time delay and time delay measurements can be used as a probe of the distance scale in the universe.

Seljak, Uros↗

Simultaneous imaging of the ferromagnetic and ferroelectric structure in multiferroic heterostructures

By measuring the spin polarization of secondary electrons and the intensity of backscattered electrons generated in a scanning electron microscope, we are able to simultaneously image the ferromagnetic domain structure of a ferromagnetic thin film and the ferroelectric domain structure of the underlying ferroelectric substrate upon which it is grown. Simultaneous imaging allows straightforward, quantitative measurements of the correlations in these complex multiferroic systems. We have successfully imaged domains in CoFe/BFO and Fe/BTO, two systems with very different ferromagnet/ferroelectric coupling mechanisms, demonstrating how this technique provides a new local probe of magneto electric/strictive effects in multiferroic heterostructures.

36 MATERIALS SCIENCE↗

Constrained Reference Star Differential Imaging: Enabling High-fidelity Imagery of Highly Structured Circumstellar Disks

High-contrast imaging presents us with the opportunity to study circumstellar disks and the planets still embedded within them, providing key insights into the formation and evolution of planetary systems. However, the postprocessing techniques that are often needed to suppress stellar halo light typically result in significant and variable loss of circumstellar light, even when using relatively conservative approaches like reference star differential imaging (RDI). We introduce “constrained reference star differential imaging” (constrained RDI), a new class of RDI point-spread-function (PSF) subtraction techniques for systems with circumstellar disks. Constrained RDI utilizes either high-resolution polarized-intensity (PI) images or disk models to severely limit or even eliminate the signal loss due to oversubtraction that is common to RDI. We demonstrate the ability of constrained RDI utilizing polarimetric data to yield an oversubtraction-free detection of the AB Aurigae protoplanetary disk in total intensity. PI-constrained RDI allows us to decisively recover the spectral signature of the confirmed, recently discovered protoplanet, AB Aurigae b. We further demonstrate that constrained RDI can be a powerful analysis tool for soon-to-be-acquired James Webb Space Telescope coronagraphic imaging of disks. In both cases, constrained RDI provides analysis-ready products that enable more detailed studies of disks and more robust verification of embedded exoplanets.

Kellen Lawson↗

The Extracellular Architecture of Adherens Junctions Revealed by Crystal Structures of Type I Cadherins

Adherens junctions, which play a central role in intercellular adhesion, comprise clusters of type I classical cadherins that bind via extracellular domains extended from opposing cell surfaces. We show that a molecular layer seen in crystal structures of E- and N-cadherin ectodomains reported here and in a previous C-cadherin structure corresponds to the extracellular architecture of adherens junctions. In all three ectodomain crystals, cadherins dimerize through a trans adhesive interface and are connected by a second, cis, interface. Assemblies formed by E-cadherin ectodomains coated on liposomes also appear to adopt this structure. Fluorescent imaging of junctions formed from wild-type and mutant E-cadherins in cultured cells confirm conclusions derived from structural evidence. Mutations that interfere with the trans interface ablate adhesion, whereas cis interface mutations disrupt stable junction formation. Our observations are consistent with a model for junction assembly involving strong trans and weak cis interactions localized in the ectodomain.

59 BASIC BIOLOGICAL SCIENCES↗

Disentangling multiple scattering with deep learning: application to strain mapping from electron diffraction patterns

Abstract A fast, robust pipeline for strain mapping of crystalline materials is important for many technological applications. Scanning electron nanodiffraction allows us to calculate strain maps with high accuracy and spatial resolutions, but this technique is limited when the electron beam undergoes multiple scattering. Deep-learning methods have the potential to invert these complex signals, but require a large number of training examples. We implement a Fourier space, complex-valued deep-neural network, FCU-Net, to invert highly nonlinear electron diffraction patterns into the corresponding quantitative structure factor images. FCU-Net was trained using over 200,000 unique simulated dynamical diffraction patterns from different combinations of crystal structures, orientations, thicknesses, and microscope parameters, which are augmented with experimental artifacts. We evaluated FCU-Net against simulated and experimental datasets, where it substantially outperforms conventional analysis methods. Our code, models, and training library are open-source and may be adapted to different diffraction measurement problems.

36 MATERIALS SCIENCE↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

The HR 4796A Debris System: Discovery of Extensive Exo-Ring Dust Material

The optically and IR-bright and starlight-scattering HR 4796A ringlike debris disk is one of the most- (and best-) studied exoplanetary debris systems. The presence of a yet-undetected planet has been inferred (or suggested) from the narrow width and inner/outer truncation radii of its r = 1farcs05 (77 au) debris ring. We present new, highly sensitive Hubble Space Telescope (HST) visible-light images of the HR 4796A circumstellar debris system and its environment over a very wide range of stellocentric angles from 0farcs32 (23 au) to ≈15'' (1100 au). These very high-contrast images were obtained with the Space Telescope Imaging Spectrograph (STIS) using six-roll PSF template–subtracted coronagraphy suppressing the primary light of HR 4796A, with three image-plane occulters, and simultaneously subtracting the background light from its close angular proximity M2.5V companion. The resulting images unambiguously reveal the debris ring embedded within a much larger, morphologically complex, and biaxially asymmetric exo-ring scattering structure. These images at visible wavelengths are sensitive to and map the spatial distribution, brightness, and radial surface density of micron-size particles over 5 dex in surface brightness. These particles in the exo-ring environment may be unbound from the system and interacting with the local ISM. Herein, we present a new morphological and photometric view of the larger-than-prior-seen HR 4796A exoplanetary debris system with sensitivity to small particles at stellocentric distances an order of magnitude greater than has previously been observed.

starlight-scattering HR 4796A↗

A survey of soft X-ray limb flare images - The relation between their structure in the corona and other physical parameters

The data used in the investigation were obtained by the American Science and Engineering S-054 experiment on board Skylab. The instrument employed was a grazing incidence X-ray telescope which records images of the sun on film. The morphology of limb flares is investigated and the observed spatial structure is related with the other physical parameters of the region (temperature, density, characteristic times, and energy density). It is concluded that two physically distinct classes of flares exist that differ both in their morphology and in the physical properties which characterize the emitting regions.

Pallavicini, R.↗

Optical properties of WO{sub 3} thin films using surface plasmon resonance technique

Indigenously assembled surface plasmon resonance (SPR) technique has been exploited to study the thickness dependent dielectric properties of WO{sub 3} thin films. WO{sub 3} thin films (80 nm to 200 nm) have been deposited onto gold (Au) coated glass prism by sputtering technique. The structural, optical properties and surface morphology of the deposited WO{sub 3} thin films were studied using X-ray diffraction, UV-visible spectrophotometer, Raman spectroscopy, and Scanning electron microscopy (SEM). XRD analysis shows that all the deposited WO{sub 3} thin films are exhibiting preferred (020) orientation and Raman data indicates that the films possess single phase monoclinic structure. SEM images reveal the variation in grain size with increase in thickness. The SPR reflectance curves of the WO{sub 3}/Au/prism structure were utilized to estimate the dielectric properties of WO{sub 3} thin films at optical frequency (λ = 633 nm). As the thickness of WO{sub 3} thin film increases from 80 nm to 200 nm, the dielectric constant is seen to be decreasing from 5.76 to 3.42, while the dielectric loss reduces from 0.098 to 0.01. The estimated value of refractive index of WO{sub 3} film is in agreement to that obtained from UV-visible spectroscopy studies. The strong dispersion in refractive index is observed with wavelength of incident laser light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-410: Evaluation of Treatment Modalities for Stereotactic Lung Radiation Therapy: A Phantom Study

Purpose: To evaluate and verify the accuracy of alternative treatment modalities for stereotactic lung therapy with end-to-end testing. We compared three dimensional conformal therapy (3DCRT), dynamic conformal arc therapy (DCAT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment using 6 MV, 6 MV flattening filter free (FFF) and 10 MV FFF photons. Methods: A QUASAR respiratory motion phantom was utilized with custom ion chamber and gafchromatic EBT2 film inserts. The phantom contained a low density lung medium with a cylindrical polystyrene tumor (35 cc). Pseudo representative structures for various organs at risk (OAR) were created. All treatment plans were created using Eclipse ver. 11 using the same image and structure sets, and delivered via Varian TrueBeam STx linear accelerator equipped with high definition MLC. Evaluation of plan quality followed ROTG 0813 criterion for conformity index (CI100%), high dose spillage, D2cm, and R50%. Results: All treatment plans met the OAR dose constraints per protocol and could be delivered without any beam hold offs or other interlocks and hence were deemed clinically safe. For equivalent beam energies, target conformity was improved for all modalities when switching to FFF mode. Treatment efficiency increased for VMAT FFF by a factor of 3–4 over IMRT, and up to factor of 7 when compared to 3DCRT. Pass rates were > 97% for all treatment using gamma criteria of 3%, 3mm. Absolute dose at iso-center was verified with ion chamber, and found to be within 2% of the treatment planning system. Conclusion: The higher dose rate associated with FFF not only reduces delivery times, but in most cases enhances plan quality. The one modality with succeeding best results for all RTOG criterions was VMAT 6 MV FFF. This end-to-end testing provides necessary confidence in the entire dose delivery chain for lung SBRT patients.

43 PARTICLE ACCELERATORS↗

Cardiovascular Imaging and Image Processing: Theory and Practice - 1975

Ultrasonography was examined in regard to the developmental highlights and present applicatons of cardiac ultrasound. Doppler ultrasonic techniques and the technology of miniature acoustic element arrays were reported. X-ray angiography was discussed with special considerations on quantitative three dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body. Nuclear cardiography and scintigraphy, three--dimensional imaging of the myocardium with isotopes, and the commercialization of the echocardioscope were studied.

Harrison, Donald C.↗

Structural and elemental changes in glioblastoma cells in situ : complementary imaging with high resolution visible light- and X-ray microscopy

The glioblastoma (GBM) is characterized by a short median survival and an almost 100% tumor related mortality. GBM cells exhibit highly invasive behavior whose mechanisms are not yet fully understood. The present study explores application of X-ray and visible light microscopy to display the elemental and structural images of cells from 3 patient derived GMB samples and an established GMB cell line. Slight differences in elemental concentrations, in actin cytoskeleton organization and cell morphology were noted between all cells types by X-ray fluorescence and full field soft X-ray microscopy, as well as the Structured Illumination Super-resolution Microscope (SIM). Different sample preparation approaches were used to match each imaging technique. While preparation for SIM included cell fixation and staining, intact frozen hydrated cells were used for the trace element imaging by hard X-ray fluorescence and exploration of the structural features by soft X-ray absorption tomography. In conclusion, each technique documented differences between samples with regard to morphology and elemental composition and underscored the importance of use of multiple patient derived samples for detailed GBM study.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution Crack Imaging Reveals Degradation Processes in Nuclear Reactor Structural Materials

Corrosion and cracking represent critical failure mechanisms for structural materials in many applications. Although a crack can often be seen with the unaided eye, higher resolution imaging techniques are required to understand the nature of the crack tips and underlying degradation processes. Researchers at Pacific Northwest National Laboratory (PNNL) employ a suite of microscopy techniques and site-specific material sampling to analyze corrosion and crack structures, producing images and compositional analyses with near-atomic spatial resolution. The samples are cracked components removed from commercial light-water reactor service or laboratory samples tested in simulated reactor environments.

36 MATERIALS SCIENCE↗

Structural investigation of the Grenville Province by radar and other imaging and nonimaging sensors

The structural investigation of the Canadian Shield by orbital radar and LANDSAT, is outlined. The area includes parts of the central metasedimentary belt and the Ontario gneiss belt, and major structures as well-expressed topographically. The primary objective is to apply SIR-B data to the mapping of this key part of the Grenville orogen, specifically ductile fold structures and associated features, and igneous, metamorphic, and sedimentary rock (including glacial and recent sediments). Secondary objectives are to support the Canadian RADARSAT project by evaluating the baseline parameters of a Canadian imaging radar satellite planned for late in the decade. The baseline parameters include optimum incidence and azimuth angles. The experiment is to develop techniques for the use of multiple data sets.

Lowman, P. D., Jr.↗

Learning from Imperfections: Predicting Structure and Thermodynamics from Atomic Imaging of Fluctuations

In materials characterization, traditionally a single experimental sample is used to derive information about a single point in the composition space, while the imperfections, impurities, and stochastic details of material structure are deemed irrelevant or complicating factors in the analysis. Here we demonstrate that atomic-scale studies of a single nominal composition can provide information about microstructures and thermodynamic response over a finite area of chemical space. Using the principles of statistical inference, we develop a framework for incorporating structural fluctuations into statistical mechanical models and use it to solve the inverse problem of deriving effective interatomic interactions responsible for elemental segregation in a La 5/8 Ca 3/8 MnO 3 thin film. Here, the results are further analyzed by a variational autoencoder to detect anomalous behavior in the composition phase diagram. This study provides a framework for creating generative models from a combination of multiple experimental data and provides direct insight into the driving forces for cation segregation in manganites.

36 MATERIALS SCIENCE↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

TUNABLE TENSOR VOTING FOR REGULARIZING PUNCTATE PATTERNS OFMEMBRANE-BOUND PROTEIN SIGNALS

Membrane-bound protein, expressed in the basal-lateral region, is heterogeneous and an important endpoint for understanding biological processes. At the optical resolution, membrane-bound protein can be visualized as being diffused (e.g., E-cadherin), punctate (e.g., connexin), or simultaneously diffused and punctate as a result of sample preparation or conditioning. Furthermore, there is a significant amount of heterogeneity as a result of technical and biological variations. This paper aims at enhancing membrane-bound proteins that are expressed between epithelial cells so that quantitative analysis can be enabled on a cell-by-cell basis. We propose a method to detect and enhance membrane-bound protein signal from noisy images. More precisely, we build upon the tensor voting framework in order to produce an efficient method to detect and refine perceptually interesting linear structures in images. The novelty of the proposed method is in its iterative tuning of the tensor voting fields, which allows the concentration of the votes only over areas of interest. The method is shown to produce high quality enhancements of membrane-bound protein signals with combined punctate and diffused characteristics. Experimental results demonstrate the benefits of using tunable tensor voting for enhancing and differentiating cell-cell adhesion mediated by integral cell membrane protein.

60 APPLIED LIFE SCIENCES↗