Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Alternative Techniques for Treatment of Complex Below-the Knee Arterial Occlusions in Diabetic Patients With Critical Limb Ischemia

The purpose of this study was to describe alternative endovascular (EV) techniques and assess their feasibility and efficacy in minimizing failure rates in limb salvage for the treatment of complex below-the knee (BTK) occlusions that could not be crossed with a conventional antegrade access. Between December 2007 and November 2010, 1,035 patients (557 male) underwent EV treatment for critical limb ischemia in our institution. In 124 (12% [83 male], mean age 68.2 {+-} 0.5 years) patients, transfemoral antegrade revascularization attempt failed, and an alternative approach was used. Follow-up was performed at 1 and 6 months. Results were compared with 56 patients treated between November 2002 and November 2007, in whom conventional technique was unsuccessful and unconventional techniques were not adopted. Technical success was achieved in 119 (96%) patients. The limb-salvage rates were 96.8% and 83% at 1- and 6-month follow-up, respectively. Sixteen (12.9%) and 33 (26.6%) patients underwent reintervention at 1- and 6-month follow-up, respectively. Transcutaneous oxygen tension increased at 1 month (44.7 {+-} 1.1 vs. 15.7 {+-} 0.8 mmHg; p < 0.001) and remained stable at follow-up. Twenty (16.1%) patients required major amputation. Thirteen (10.4%) patients died during follow-up. In our previous experience, percutaneous transluminal angioplasty failure, amputation, and death rates were 10.9, 39.2, and 23.2%, respectively. Alternative techniques allowed a significant decrease of major amputation and death rates (p = 0.0001 and p = 0.02, respectively). The use of alternative techniques seems feasible in case of a failed antegrade BTK revascularization attempt and could minimize failure rates in the treatment of complex occlusions while providing satisfying clinical success rates at 6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Accuracy of Percutaneous Biopsy Using “Cross and Push” Technique for Patients Suspected with Malignant Biliary Strictures

PurposeVarious methods have been used to sample biliary strictures, including percutaneous fine-needle aspiration biopsy, intraluminal biliary washings, and cytological analysis of drained bile. However, none of these methods has proven to be particularly sensitive in the diagnosis of biliary tract malignancy. We report improved diagnostic accuracy using a modified technique for percutaneous transluminal biopsy in patients with this disease.Materials and MethodsFifty-two patients with obstructive jaundice due to a biliary stricture underwent transluminal forceps biopsy with a modified “cross and push” technique with the use of a flexible biopsy forceps kit commonly used for cardiac biopsies. The modification entailed crossing the stricture with a 0.038-in. wire leading all the way down into the duodenum. A standard or long sheath was subsequently advanced up to the stricture over the wire. A Cook 5.2-Fr biopsy forceps was introduced alongside the wire and the cup was opened upon exiting the sheath. With the biopsy forceps open, within the stricture the sheath was used to push and advance the biopsy cup into the stricture before the cup was closed and the sample obtained. The data were analysed retrospectively.ResultsWe report the outcomes of this modified technique used on 52 consecutive patients with obstructive jaundice secondary to a biliary stricture. The sensitivity and accuracy were 93.3 and 94.2 %, respectively. There was one procedure-related late complication.ConclusionWe propose that the modified “cross and push” technique is a feasible, safe, and more accurate option over the standard technique for sampling strictures of the biliary tree.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed the complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein

PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Restoration of Dehiscent Pancreaticojejunostomy Causing a Major Postoperative Pancreatic Fistula by Reinsertion of a Pancreatic Duct Tube Using the Rendezvous Technique

Introduction: A postoperative clinically relevant pancreatic fistula can cause severe sequelae. We aimed to describe our minimally invasive procedure (rendezvous technique) for the treatment of a pancreatic fistula resulting from pancreaticojejunal anastomosis dehiscence involving a dislodged main pancreatic duct tube. Methods: In our rendezvous technique, a guidewire is advanced into the jejunal lumen from the access site of the drainage tube and is caught by a snare catheter, which is used to replace the dislodged main pancreatic duct tube. Then, the guidewire is passed from the access site of the drainage tube to the site of the dislodged main pancreatic duct tube. A sheath is inserted along the route of the dislodged main pancreatic duct tube and is placed across the pancreaticojejunal anastomosis over the guidewire. Another guidewire is advanced into the main pancreatic duct via the sheath, and a new main pancreatic duct tube is inserted into the main pancreatic duct over the second wire. This technique was performed in two patients with a pancreatic fistula. Results: Our rendezvous technique was successfully performed in a 73-year-old man with an intractable clinically relevant pancreatic fistula and large discharge from the drain and a 74-year-old woman with a pancreatic fistula and fluid collection between the elevated jejunum and remnant pancreas. Discharge from the drain and fluid collection decreased after the procedure. Conclusion: Our rendezvous technique is an effective minimally invasive approach for a pancreatic fistula resulting from pancreaticojejunal anastomosis dehiscence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Tensile Experimental Techniques for Geomaterials: A Comprehensive Review

Here, this review article is dedicated to the Dynamic Behavior of Materials Technical Division for celebrating the 75th anniversary of the Society for Experimental Mechanics (SEM). Understanding dynamic behavior of geomaterials is critical for analyzing and solving engineering problems of various applications related to underground explosions, seismic, airblast, and penetration events. Determining the dynamic tensile response of geomaterials has been a great challenge in experiments due to the nature of relatively low tensile strength and high brittleness. Various experimental approaches have been made in the past century, especially in the most recent half century, to understand the dynamic behavior of geomaterials in tension. In this review paper, we summarized the dynamic tensile experimental techniques for geomaterials that have been developed. The major dynamic tensile experimental techniques include dynamic direct tension, dynamic split tension, and spall tension. All three of the experimental techniques are based on Hopkinson or split Hopkinson (also known as Kolsky) bar techniques and principles. Finally, uniqueness and limitations for each experimental technique are also discussed.

36 MATERIALS SCIENCE↗

Advances in in situ/operando techniques for catalysis research: enhancing insights and discoveries

Abstract Catalysis research has witnessed remarkable progress with the advent of in situ and operando techniques. These methods enable the study of catalysts under actual operating conditions, providing unprecedented insights into catalytic mechanisms and dynamic catalyst behavior. This review discusses key in situ techniques and their applications in catalysis research. Advances in in situ electron microscopy allow direct visualization of catalysts at the atomic scale under reaction conditions. In situ spectroscopy techniques like X-ray absorption spectroscopy and nuclear magnetic resonance spectroscopy can track chemical states and reveal transient intermediates. Synchrotron-based techniques offer enhanced capabilities for in situ studies. The integration of in situ methods with machine learning and computational modeling provides a powerful approach to accelerate catalyst optimization. However, challenges remain regarding radiation damage, instrumentation limitations, and data interpretation. Overall, continued development of multi-modal in situ techniques is pivotal for addressing emerging challenges and opportunities in catalysis research and technology.

Chen, Linfeng↗

Application of materials informatics to vapor-grown carbon nanofiber/vinyl ester nanocomposites through self-organizing maps and clustering techniques

Data mining and knowledge discovery techniques were employed herein to acquire new information on the viscoelastic, flexural, compressive, and tensile properties of vapor-grown carbon nanofiber (VGCNF)/vinyl ester (VE) nanocomposites. Formulation and processing factors (curing environment, presence or absence of dispersing agent, mixing method, VGCNF weight fraction, VGCNF type, high-shear mixing time, and sonication time) and testing temperature were utilized as inputs and the true ultimate strength, true yield strength, engineering elastic modulus, engineering ultimate strength, flexural modulus, flexural strength, storage modulus, loss modulus, and tan delta were selected as outputs. The data mining and knowledge discovery algorithms used in this study include self-organizing maps (SOMs) and clustering techniques. SOMs demonstrated that temperature and tan delta had the most significant effects on the output responses followed by the VGCNF high-shear mixing time, and sonication time. SOMs were also used to produce optimal responses using certain combination(s) of inputs. Fuzzy C-means algorithm (FCM) was also applied to discover patterns in the nanocomposite behavior subsequent to a principal component analysis (PCA), which is a dimensionality reduction technique. Utilizing these techniques, the nanocomposite specimens were separated into different clusters based on the testing temperature (30 °C and 120 °C being the most dominant responses), tan delta, high-shear mixing time, and sonication time. Furthermore, the VGCNF/VE specimens were separated into a cluster based on their viscoelastic responses (storage and loss moduli) at the same temperature. The FCM results indicate that, while all nanocomposite properties in the new framework are essential, the viscoelastic responses of the VGCNF/VE specimens are the most significant. Here this work highlights the utility of data mining and knowledge discovery techniques in the context of materials informatics for the discovery of patterns and trends in the material behavior that are not immediately known.

36 MATERIALS SCIENCE↗

Melting and phase relations of Fe-Ni-Si determined by a multi-technique approach

Many studies have suggested silicon as a candidate light element for the cores of Earth and Mercury. However, the effect of silicon on the melting temperatures of core materials and thermal profiles of cores is poorly understood, due to disagreements among melt detection techniques, uncertainties in sample pressure evolution during heating, and sparsity of studies investigating the combined effects of nickel and silicon on the phase diagram of iron. Here, in this study we develop a multi-technique approach for measuring the high-pressure melting and solid phase relations of iron alloys and apply it to Fe 0.8 Ni 0.1 Si 0.1 (Fe-11wt%Ni-5.3wt%Si), a composition compatible with recent estimates for the cores of Earth and Mercury. This approach combines results (20-83 GPa) from two atomic-level techniques: synchrotron Mossbauer spectroscopy (SMS) and synchrotron x-ray diffraction (XRD). Melting is independently detected by the loss of the Mossbauer signal, produced exclusively by solid-bound iron nuclei, and the onset of a liquid diffuse x-ray scattering signal. The use of a burst heating and background updating method for quantifying changes in the reference background during heating facilitates the determination of liquid diffuse signal onsets and leads to strong reproducibility and excellent agreement in melting temperatures determined separately by the two techniques. XRD measurements additionally constrain the hcp-fcc phase boundary and in-situ pressure evolution of the samples during heating. We apply our updated thermal pressure model to published SMS melting data on fcc-Fe and fcc-Fe 0.9 Ni 0.1 to precisely evaluate the effect of silicon on melting temperatures. We find that the addition of 10 mol% Si to Fe 0.9 Ni 0.1 reduces melting temperatures by ~250 K at low pressures (<60 GPa) and flattens the hcp-fcc phase boundary. Extrapolating our results, we constrain the location of the hcp-fcc-liquid quasi-triple point at 147±14 GPa and 3140±90 K, which implies a melting temperature reduction of 500 K compared with Fe 0.9 Ni 0.1 . The results demonstrate the advantages of combining complementary experimental techniques in investigations of melting under extreme conditions.

36 MATERIALS SCIENCE↗

Evaluation of macrozone dimensions by ultrasound and EBSD techniques

Titanium alloys are known to have texture heterogeneities, i.e. regions much larger than the grain dimensions, where the local orientation distribution of the grains differs from one region to the next. The electron backscattering diffraction (EBSD) technique is the method of choice to characterize these macro regions, which are called macrozones. Qualitatively, the images obtained by EBSD show that these macrozones may be larger or smaller, elongated or equiaxed. However, often no well-defined boundaries are observed between the macrozones and it is very hard to obtain objective and quantitative estimates of the macrozone dimensions from these data. In the present work, we present a novel, non-destructive ultrasonic technique that provides objective and quantitative characteristic dimensions of the macrozones. The obtained dimensions are based on the spatial autocorrelation function of fluctuations in the sound velocity. Thus, a pragmatic definition of macrozone dimensions naturally arises from the ultrasonic measurement. This paper has three objectives: 1) to disclose the novel, non-destructive ultrasonic technique to measure macrozone dimensions, 2) to propose a quantitative and objective definition of macrozone dimensions adapted to and arising from the ultrasonic measurement, and which is also applicable to the orientation data obtained by EBSD, and 3) to compare the macrozone dimensions obtained using the two techniques on two samples of the near-alpha titanium alloy IMI834. In addition, it was observed that macrozones may present a semi-periodical arrangement. - Highlights: Black-Right-Pointing-Pointer Discloses a novel, ultrasonic NDT technique to measure macrozone dimensions Black-Right-Pointing-Pointer Proposes a quantitative and objective definition of macrozone dimensions Black-Right-Pointing-Pointer Compares macrozone dimensions obtained using EBSD and ultrasonics on 2 Ti samples Black-Right-Pointing-Pointer Observes that macrozones may have a semi-periodical arrangement.

36 MATERIALS SCIENCE↗

Analysis of the energy distribution of interface traps related to tunnel oxide degradation using charge pumping techniques for 3D NAND flash applications

Graphical abstract: The degradation tendency extracted by CP technique was almost the same in both the bulk-type and TFT-type cells. - Highlights: • D{sub it} is directly investigated from bulk-type and TFT-type CTF memory. • Charge pumping technique was employed to analyze the D{sub it} information. • To apply the CP technique to monitor the reliability of the 3D NAND flash. - Abstract: The energy distribution and density of interface traps (D{sub it}) are directly investigated from bulk-type and thin-film transistor (TFT)-type charge trap flash memory cells with tunnel oxide degradation, under program/erase (P/E) cycling using a charge pumping (CP) technique, in view of application in a 3-demension stackable NAND flash memory cell. After P/E cycling in bulk-type devices, the interface trap density gradually increased from 1.55 × 10{sup 12} cm{sup −2} eV{sup −1} to 3.66 × 10{sup 13} cm{sup −2} eV{sup −1} due to tunnel oxide damage, which was consistent with the subthreshold swing and transconductance degradation after P/E cycling. Its distribution moved toward shallow energy levels with increasing cycling numbers, which coincided with the decay rate degradation with short-term retention time. The tendency extracted with the CP technique for D{sub it} of the TFT-type cells was similar to those of bulk-type cells.

36 MATERIALS SCIENCE↗

Dosimetric Comparison of Split Field and Fixed Jaw Techniques for Large IMRT Target Volumes in the Head and Neck

Some treatment planning systems (TPSs), when used for large-field (>14 cm) intensity-modulated radiation therapy (IMRT), create split fields that produce excessive multiple-leaf collimator segments, match-line dose inhomogeneity, and higher treatment times than nonsplit fields. A new method using a fixed-jaw technique (FJT) forces the jaw to stay at a fixed position during optimization and is proposed to reduce problems associated with split fields. Dosimetric comparisons between split-field technique (SFT) and FJT used for IMRT treatment is presented. Five patients with head and neck malignancies and regional target volumes were studied and compared with both techniques. Treatment planning was performed on an Eclipse TPS using beam data generated for Varian 2100C linear accelerator. A standard beam arrangement consisting of nine coplanar fields, equally spaced, was used in both techniques. Institutional dose-volume constraints used in head and neck cancer were kept the same for both techniques. The dosimetric coverage for the target volumes between SFT and FJT for head and neck IMRT plan is identical within {+-}1% up to 90% dose. Similarly, the organs at risk (OARs) have dose-volume coverage nearly identical for all patients. When the total monitor unit (MU) and segments were analyzed, SFT produces statistically significant higher segments (17.3 {+-} 6.3%) and higher MU (13.7 {+-} 4.4%) than the FJT. There is no match line in FJT and hence dose uniformity in the target volume is superior to the SFT. Dosimetrically, SFT and FJT are similar for dose-volume coverage; however, the FJT method provides better logistics, lower MU, shorter treatment time, and better dose uniformity. The number of segments and MU also has been correlated with the whole body radiation dose with long-term complications. Thus, FJT should be the preferred option over SFT for large target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of metastatic spinal photon treatment techniques

Traditional palliative treatment of metastatic cancer to the vertebral bodies often results in doses to the spinal cord that are higher than the dose prescribed to the target, or gross tumor volume (GTV). This study compares traditional techniques of spine palliation with intensity-modulated radiation therapy (IMRT). The purpose of the study is 2-fold: first, the study demonstrates the benefits of using IMRT to lower the dose to the organs at risk (OAR), particularly for the spinal cord and other nonspecified normal tissues; second, the article provides information regarding the advantages and disadvantages of commonly used conventional techniques for treating the vertebral bodies based on patient anatomy. Because the use of IMRT or other advanced techniques may be prohibitive because of insurance issues, treatment plans were created that compared optimal coverage vs. optimal sparing for single-field, wedged-pair, and opposed-beam arrangements. Fifty-five patients were selected and divided by location of target (cervical, thoracic, and lumbar spine) and also by the measured separation between the anterior and posterior surface of the patient at the level of mid-GTV. Within each anatomic category the patients again were divided into the categories of small, medium, and large based on separation. The patient dataset that most closely represented the average separation within each category was selected, resulting in a total of 9 patients, and the appropriate treatment plan techniques were calculated for each of the 9 patients. The results of the study do show that the use of IMRT is far superior when compared with other techniques, both for coverage and for sparing of the surrounding tissue, regardless of patient size and the section of spine being treated. Based on a combination of both target coverage and sparing of normal tissues, the conventional plan of choice may vary by both the section of spine to be treated and by the size of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

A survey on processing-in-memory techniques: Advances and challenges

Processing-in-memory (PIM) techniques have gained much attention from computer architecture researchers, and significant research effort has been invested in exploring and developing such techniques. Increasing the research activity dedicated to improving PIM techniques will hopefully help deliver PIM’s promise to solve or significantly reduce memory access bottleneck problems for memory-intensive applications. We also believe it is imperative to track the advances made in PIM research to identify open challenges and enable the research community to make informed decisions and adjust future research directions. In this survey, we analyze recent studies that explored PIM techniques, summarize the advances made, compare recent PIM architectures, and identify target application domains and suitable memory technologies. We also discuss proposals that address unresolved issues of PIM designs (e.g., address translation/mapping of operands, workload analysis to identify application segments that can be accelerated with PIM, OS/runtime support, and coherency issues that must be resolved to incorporate PIM). We believe this work can serve as a useful reference for researchers exploring PIM techniques.

97 MATHEMATICS AND COMPUTING↗

Survey of Cyber Risk Analysis Techniques for Use in the Nuclear Industry

Using traditional probabilistic risk analysis methods for severe accident safety risk management on non-digital systems, structures, and components at nuclear power plants is well-established. In contrast, cyber risk analysis of digital assets is still an immature field with unproven techniques due, in part, to the continuously changing threat environment and the challenge of digital assets failing in unexpected ways. As the nuclear fleet continues to adopt digital instrumentation and control systems, it is increasingly important to have effective and efficient cyber risk analysis techniques to support risk management decisions, such as risk elimination by system redesign or risk mitigation by implementation of prioritized security controls. To understand the state of the art in cyber risk analysis for future research, we surveyed 36 publications across ten application domains. We describe our survey methodology and rate each technique based upon scope, adoptability, and repeatability. In this work, we examine the unique constraints of the nuclear industry and outline the strengths and weaknesses of using the cyber risk analysis techniques in the industry, highlighting gaps with current techniques. We also discuss challenges and potential research directions for advancing the science for both existing and new advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Brownian bridge-based speed imputation technique for truck energy consumption and emissions estimation

The available truck Global Positioning System (GPS) data, typically collected with large time gaps, rely on imputation techniques to obtain second-by-second data that are required in models for estimating truck energy consumption and emissions. However, existing speed imputation techniques either require a large amount of high-resolution data for model training or rely on special movement assumptions. Here, to fill the gap and effectively apply the low-resolution truck GPS datasets, this paper proposes a simple imputation technique that adopts the Brownian bridge structure to impute missing speed data. The proposed technique introduces a feasible imputation region and a combined drift into the imputation procedure to capture vehicle acceleration constraint, travel distance constraint, and speed volatility. The calibrated model is applied to a set of low-resolution truck GPS data. The results demonstrate the robustness of the proposed technique in enhancing estimation accuracy when using low-resolution GPS data to estimate fuel consumption and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging nanofabrication and quantum confinement techniques for 2D materials beyond graphene

Abstract Recent advances in growth techniques have enabled the synthesis of high-quality large area films of 2D materials beyond graphene. As a result, nanofabrication methods must be developed for high-resolution and precise processing of these atomically thin materials. These developments are critical both for the integration of 2D materials in complex, integrated circuitry, as well as the creation of sub-wavelength and quantum-confined nanostructures and devices which allow the study of novel physical phenomena. In this review, we summarize recent advances in post-synthesis nanopatterning and nanofabrication techniques of 2D materials which include (1) etching techniques, (2) atomic modification, and (3) emerging nanopatterning techniques. We detail novel phenomena and devices which have been enabled by the recent advancement in nanofabrication techniques and comment on future outlook of 2D materials beyond graphene.

Stanford, Michael G.↗

On the Applications of IBA Techniques to Biological Samples Analysis: PIXE and RBS

The analytical techniques based on ion beams or IBA techniques give quantitative information on elemental concentration in samples of a wide variety of nature. In this work, we focus on PIXE technique, analyzing thick target biological specimens (TTPIXE), using 3 MeV protons produced by an electrostatic accelerator. A nuclear microprobe was used performing PIXE and RBS simultaneously, in order to solve the uncertainties produced in the absolute PIXE quantifying. The advantages of using both techniques and a nuclear microprobe are discussed. Quantitative results are shown to illustrate the multielemental resolution of the PIXE technique; for this, a blood standard was used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗