Search NASA⌕ Search

SEARCH · Search NASA

Results for “test case”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Effect of Strength of Soluble and Solid Acid Catalysts on Selectivity in Aldol Reactions

Aldol reactions can follow the classical condensation path and produce an α,β-unsaturated carbonyl compound and water, however in some cases, aldol chemistry may be steered towards a fission that gives an olefin and a carboxylic acid. This investigation examines how the strength of Brønsted acid sites—both in homogeneous and heterogeneous catalysis—controls these two pathways and their kinetics. The cross-aldol reaction between benzaldehyde and 3-pentanone served as test case. Batch reactions, conducted in toluene as solvent at a temperature of 140 °C under autogenous pressure, were analyzed by GC and in situ ATR-FTIR spectroscopy to determine product distributions and rate constants for condensation and fission pathways. A series of soluble acids including a family of sulfonic acids mostly favored the condensation pathway, with formic acid as the weakest in the series by its pKa being inactive for aldol chemistry. Significant amounts of fission products were rare except for the known selectivity of phosphoric acid, and the circumstances were difficult to delineate. For the sulfonic acid family, the logarithm of the first-order condensation rate constants scaled only roughly with pKa (water) values, whereas a good correlation was obtained with calculated deprotonation Gibbs energies in toluene. A series of H-forms of isomorphously substituted beta zeolites, HESiBEA with E = Al, Ga, Fe, or B, favored the fission pathway. Site density and site strength were characterized by calorimetric measurements of the heats of adsorption of isopropylamine, which decreased in the order Al > Ga, Fe > B. The logarithm of the site-normalized first-order fission rate constants scaled roughly with the heats of adsorption and correlated excellently with reported deprotonation energies. In conclusion, acid strength mainly affects activity and can be seen as a pre-requisite for either aldol condensation or fission chemistry, whereas additional, yet to be full clarified catalyst properties and reaction conditions are required to steer aldol chemistry towards fission selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bonneville Powerhouse 2 Fish Guidance Efficiency Studies: CFD Model of the Forebay

In ongoing work, U.S. Army Corps of Engineers, Portland District (CENWP) is seeking to better understand and improve the conditions within the Bonneville Powerhouse 2 (B2) turbine intakes to improve survival of downstream migrant salmonid smolt. In this study, the existing B2 forebay computational fluid dynamics (CFD) model was modified to include a more detailed representation of all B2 turbine intakes. The modified model was validated to existing field-measured forebay ADCP velocities. The initial CFD model scenarios tested a single project operation and the impact of adding the Behavior Guidance System (BGS) or Corner Collector. These structures had impacts on forebay flows. Most notable was that the addition of the BGS and Corner Collector reduced the lateral extent of the recirculation areas on the Washington shore and Cascade Island and reduced the flow velocity parallel to the powerhouse in front of Units 11 and 12. For these same cases, at the turbine intakes across the powerhouse, there was very little difference in the flow volume into the gatewell for the clean forebay, and the forebay with the BGS in place and/or the Corner Collector operating. The largest differences were at Units 11 to 13. The CFD model cases testing the impact of the gatewell slot fillers showed no impact to the forebay flows, but large differences within the gatewells. With the slot fillers, the flow above the standard traveling screen and into the gatewell increased (about 100 cfs at each turbine intake) and the gap flow decreased across the powerhouse for all cases. The increased flow up the gatewell was further enhanced with only half the units operating. The flow into the gatewell slot was increased about 35 cfs for each bay of each intake across the powerhouse; this change was uniform across the powerhouse. The flows in the gatewell of Unit 12, the most impacted unit for the scenarios, was evaluated. In front of the vertical barrier screen, the CFD model with slot fillers showed reduced the maximum velocities (in spite of the increased the flow into the gatewell), and decreased the area of recirculation. The area near the VBS exceeding the normal velocity criteria of 1 ft/s was reduced and the flows were more balanced.

Bonneville↗

Ligand-Binding-Site Refinement to Generate Reliable Holo Protein Structure Conformations from Apo Structures

The first important step in a structure-based virtual screening is the judicious selection of a receptor protein. In cases where the holo protein receptor structure is unavailable, significant reduction in virtual screening performance has been reported. In this work, we present a robust method to generate reliable holo protein structure conformations from apo structures using molecular dynamics (MD) simulation with restraints derived from holo structure binding-site templates. We perform benchmark tests on two different datasets: 40 structures from a directory of useful decoy-enhanced (DUD-E) and 84 structures from the Gunasekaran dataset. Our results show successful refinement of apo binding-site structures toward holo conformations in 82% of the test cases. In addition, virtual screening performance of 40 DUD-E structures is significantly improved using our MD-refined structures as receptors with an average enrichment factor (EF), an EF1% value of 6.2 compared to apo structures with 3.5. Docking of native ligands to the refined structures shows an average ligand root mean square deviation (RMSD) of 1.97 Å (DUD-E dataset and Gunasekaran dataset) relative to ligands in the holo crystal structures, which is comparable to the self-docking (i.e., docking of the native ligand back to its crystal structure receptor) average, 1.34 Å (DUD-E dataset) and 1.36 Å (Gunasekaran dataset). On the other hand, docking to the apo structures yields an average ligand RMSD of 3.65 Å (DUD-E) and 2.90 Å (Gunasekaran). These results indicate that our method is robust and can be useful to improve virtual screening performance of apo structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

WE-F-201-03: Evaluate Clinical Cases Using Commercially Available Systems and Compare to TG-43 Dosimetry

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

E-PINNs: Epistemic Physics-Informed Neural Networks

Physics-informed neural networks (PINNs) have demonstrated promise as a framework for solving forward and inverse problems involving partial differential equations. Despite recent progress in the field, it remains challenging to quantify uncertainty in these networks. While techniques such as Bayesian PINNs (B-PINNs) provide a principled approach to capturing epistemic uncertainty through Bayesian inference, they can be computationally expensive for large-scale applications. In this work, we propose Epistemic Physics-Informed Neural Networks (E-PINNs), a framework that uses a small network, the epinet, to efficiently quantify epistemic uncertainty in PINNs. The proposed approach works as an add-on to existing, pre-trained PINNs with a small computational overhead. We demonstrate the applicability of the proposed framework in various test cases and compare the results with B-PINNs using Hamiltonian Monte Carlo (HMC) posterior estimation and dropout-equipped PINNs (Dropout-PINNs). In our experiments, E-PINNs achieve calibrated coverage with competitive sharpness at substantially lower cost. We demonstrate that when B-PINNs produce narrower bands, they under-cover in our tests. E-PINNs also show better calibration than Dropout-PINNs in these examples, indicating a favorable accuracy-efficiency trade-off.

AI for Science↗

COMPARISON OF RADIO-FREQUENCY INTERFERENCE MITIGATION STRATEGIES FOR DISPERSED PULSE DETECTION

Impulsive radio-frequency signals from astronomical sources are dispersed by the frequency-dependent index of refraction of the interstellar media and so appear as chirped signals when they reach Earth. Searches for dispersed impulses have been limited by false detections due to radio-frequency interference (RFI) and, in some cases, artifacts of the instrumentation. Many authors have discussed techniques to excise or mitigate RFI in searches for fast transients, but comparisons between different approaches are lacking. This work develops RFI mitigation techniques for use in searches for dispersed pulses, employing data recorded in a 'Fly's Eye' mode of the Allen Telescope Array as a test case. We gauge the performance of several RFI mitigation techniques by adding dispersed signals to data containing RFI and comparing false alarm rates at the observed signal-to-noise ratios of the added signals. We find that Huber filtering is most effective at removing broadband interferers, while frequency centering is most effective at removing narrow frequency interferers. Neither of these methods is effective over a broad range of interferers. A method that combines Huber filtering and adaptive interference cancelation provides the lowest number of false positives over the interferers considered here. The methods developed here have application to other searches for dispersed pulses in incoherent spectra, especially those involving multiple beam systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Screening Current Effects in a Hybrid Nb$_{3}$Sn/REBCO Superconducting Accelerator Magnet Using a T - A Formulation

To explore the feasibility of using high-temperature superconducting (HTS) REBCO coated conductors in future accelerator magnets, two REBCO flat racetrack coils were fabricated using 4-mm wide EuBCO tapes at the High Energy Accelerator Research Organization (KEK). These coils were tested as an insert inside a Nb$_{3}$Sn common-coil dipole magnet, which provides a background field of up to $\sim$ 9.5T, at the Brookhaven National Laboratory (BNL). REBCO tapes offer exceptionally high critical current density under strong magnetic fields; however, they also exhibit significant magnetization due to screening currents, leading to magnetic field errors. Here, this study presents a 2D finite element model of screening current-induced fields (SCIF) in REBCO coils using the T-A formulation, along with the results obtained. Simulations were then performed for two KEK test cases: one where the REBCO conductors were oriented with the HTS tapes parallel to the background field, and another where the tapes were perpendicular to it. Since screening currents also influence the stress distribution and increase the peak stress in the coils, the mechanical effects of these currents were analyzed. The implications of these simulation and test results for the design of Nb$_{3}$Sn/REBCO superconducting accelerator magnets are discussed.

Accelerator magnets↗

Automated extraction of interfacial dislocations and disconnections from atomistic data

Here we introduce Interfacial Line Defect Analysis (ILDA), a method for identifying and extracting interfacial dislocations and disconnections with little-to-no input from the user on the nature of the interface. By simply providing the orientations and coherency strains for the crystals in a coherent reference state of the interface, ILDA provides exact Burgers vectors. Alternatively, these orientations and strains can be estimated using local atomic deformation gradients, making ILDA fully automated and providing estimated Burgers vectors. ILDA also determines the step height associated with each defect line segment, in case the associated defect is a disconnection. The heart of the method is the identification of atoms residing at co-incidence sites between the two crystals and the construction of a surface mesh connecting these sites that is used to compose Burgers circuits and insert defect line segments. We demonstrate the performance of ILDA in two test cases: a twist grain boundary and a phase boundary.

36 MATERIALS SCIENCE↗

Hermite WENO limiting for multi-moment finite-volume methods using the ADER-DT time discretization for 1-D systems of conservation laws

New Hermite Weighted Essentially Non-Oscillatory (HWENO) interpolants are developed and investigated within the Multi-Moment Finite-Volume (MMFV) formulation using the ADER-DT time discretization. Whereas traditional WENO methods interpolate pointwise, function-based WENO methods explicitly form a non-oscillatory, high-order polynomial over the cell in question. This study chooses a function-based approach and details how fast convergence to optimal weights for smooth flow is ensured. Methods of sixth-, eighth-, and tenth-order accuracy are developed. We compare these against traditional single-moment WENO methods of fifth-, seventh-, ninth-, and eleventh-order accuracy to compare against more familiar methods from literature. The new HWENO methods improve upon existing HWENO methods (1) by giving a better resolution of unreinforced contact discontinuities and (2) by only needing a single HWENO polynomial to update both the cell mean value and cell mean derivative. Test cases to validate and assess these methods include 1-D linear transport, the 1-D inviscid Burger's equation, and the 1-D inviscid Euler equations. Smooth and non-smooth flows are used for evaluation. These HWENO methods performed better than comparable literature-standard WENO methods for all regimes of discontinuity and smoothness in all tests herein. They exhibit improved optimal accuracy due to the use of derivatives, and they collapse to solutions similar to typical WENO methods when limiting is required. The study concludes that the new HWENO methods are robust and effective when used in the ADER-DT MMFV framework. Finally, these results are intended to demonstrate capability rather than exhaust all possible implementations.

97 MATHEMATICS AND COMPUTING↗

Experimental Evaluation of Multi-spacecraft Data Analysis Techniques in a Laboratory Plasma

The Magnetic Reconnection Experiment (MRX)[1] has been utilized to assess the effectiveness of minimum variance analysis on the magnetic field (MVAB) and boundary-crossing time analysis (BCTA). The neutral sheet is swept, or jogged, in a controlled manner with respect to the stationary probes by pulsed internal coil currents. Magnetic field data from measurement points resembling data from multi-spacecraft flying though a reconnecting current sheet is used to check both techniques to deduce a proper normal vector. We examine discharges with the two-dimensional (2-D) X-line structure as well as cases in which a flux rope forms within the layer. All discharges are in a two-fluid regime in which electrons are magnetized but not ions. Boundary-crossing time analysis with four sample measurement points forming a tetrahedron generates a reasonable unit normal vector and relative velocity along the normal vector for all of the tested cases. On the other hand, MVAB sometimes fails to predict a proper normal direction. This is because the X-line magnetic geometry is fundamentally 2-D or 3-D. However, the direction along the reconnecting field determined by MVAB does not deviate much from the real magnetic geometry documented by 2-D magnetic probe arrays and one additional probe at a different toroidal location. Based on these observations, we suggest a procedure for determining a local coordinate system for data from the Magnetospheric Multi-Scale (MMS) mission when spacecraft passes through a reconnecting current sheet. The distance between measurement points on the order of the ion skin depth ($c/\omega_{pi}$) is pertinent to determination of the magnetic geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Exascale Earth System Model v2.0.1

First patch release of v2.0.0 Changes since v2.0.0 [Important change] Fix ocean threading bug seen in debug cases on Chrysalis with Intel 20.0.4. Was introduced around time of v2.0.0 tag. Does not change v2.0.0 answers on Chrysalis because those didn't use threading or debugging. [EAM] Add semi-lagrangian tracer transport for theta-l (F90 and C++), add new algorithm for finding tropopause, add DSCREAM to allow v2 and SCREAM settings in same code such as adjust_ps [EAM-MMF] 60L default, allow C++ back end of RRTMGP (EAM too). [EAMxx] add nu-top functionality, fix forcing functor, add ttype9 and dcmip2012 tests 2.1, 2.2, and 3 HOMME: remove obsolete remap algs, option to specify dynamics alg indep of tracer, new sponge layer, add imex tests [ELM] Add topography-based subgrid (topounits), add FATES-ELM Nitro., Phos. and CH4 coupling, add land-use ts for NARRM, add lulc for SSP3 RCP7, Fix nutrient fertilization exp test and carbon isotope flux, Fix xactive lnd dry deposition, add lake water storage option, fix plant hydraulics 2d params, fix carbon budget calc, fix soil nutrient conc. bug, fix mosart dam bug, add test for new ELM, MOSART features, fix bug in O3 dry dep stomatal resistances, fix plant hydraulics restart BFB error, update mkmapdata. [MOSART] fix bug for reading the latitude from an unstructured input file, fix oversat in bubble test. [MPAS-ocean] Add CFC11, CFC12 tracers, add 2D spherical transport tests, fix del4 tracer mixing, add MARBL ocean tracer mixing, modify harmonic analysis options, add GPU port of vmix routines, fix calc of ML-averaged BV freq. [MPAS-seaice] Change extents of initial polar disks for oRRS18to6v3 grid, fix ice BGC with MARBL, update spherical test cases, fix DON coupling, Remove Cf from sea ice constants. [MPAS-landice] add CRYO1850-4xCO2 compset [CIME] add GCP, ANL GCE, Spock, Perlmutter, deprecate config_compilers.xml, fix and clean-up cmake macros, fix slurm bindings, refactor CIME internal testing, cleanup SCORPIO perf data, allow position independent compset naming, [also] update v2 benchmarking suite, extend e3sm_prod with throughput and memory checks

E3SM Project, DOE↗

Reaction Path Optimization with Holonomic Constraints and Kinetic Energy Potentials

Two methods are developed to enhance the stability, efficiency, and robustness of reaction path optimization using a chain of replicas. First, distances between replicas are kept equal during path optimization via holonomic constraints. Finding a reaction path is, thus, transformed into a constrained optimization problem. This approach avoids force projections for finding minimum energy paths (MEPs), and fast-converging schemes such as quasi-Newton methods can be readily applied. Second, we define a new objective function - the total Hamiltonian - for reaction path optimization, by combining the kinetic energy potential of each replica with its potential energy function. Minimizing the total Hamiltonian of a chain determines a minimum Hamiltonian path (MHP). If the distances between replicas are kept equal and a consistent force constant is used, then the kinetic energy potentials of all replicas have the same value. The MHP in this case is the most probable isokinetic path. Our results indicate that low-temperature kinetic energy potentials (<5 K) can be used to prevent the development of kinks during path optimization and can significantly reduce the required steps of minimization by 2-3 times without causing noticeable differences between a MHP and MEP. These methods are applied to three test cases, the C₇eq-to-Cax isomerization of an alanine dipeptide, the ⁴C₁- to-¹C₄ transition of an α-D-glucopyranose, and the helix-to-sheet transition of a GNNQQNY heptapeptide. By applying the methods developed in this work, convergence of reaction path optimization can be achieved for these complex transitions, involving full atomic details and a large number of replicas (>100). For the case of helix-to-sheet transition, we identify pathways whose energy barriers are consistent with experimental measurements. Further, we develop a method based on the work energy theorem to quantify the accuracy of reaction paths and to determine whether the atoms used to define a path are enough to provide quantitative estimation of energy barriers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification & Validation of High-Order Short-Characteristics-Based Deterministic Transport Methodology on Unstructured Grids

The research team has developed a practical, high-order, discrete-ordinates, short characteristics neutron transport code for three-dimensional configurations represented on unstructured tetrahedral grids that can be used for realistic reactor physics applications at both the assembly and core levels. This project will perform a comprehensive verification and validation of this new computational tool against both a continuous-energy Monte Carlo simulation (e.g. MCNP) and experimentally measured data, an essential prerequisite for its deployment in reactor core modeling. Verification is divided into three phases. The team will first conduct spatial mesh and expansion order refinement studies to monitor convergence of the numerical solution to reference solutions. This is quantified by convergence rates that are based on integral error norms computed from the cell-by-cell difference between the code’s numerical solution and its reference counterpart. The latter is either analytic or very fine- mesh numerical solutions from independent computational tools. For the second phase, the team will create a suite of code-independent benchmark configurations to enable testing the theoretical order of accuracy of any particular discretization of the discrete ordinates approximation of the transport equation. For each tested case (i.e. mesh and spatial approximation order), researchers will execute the code and compare the resulting numerical solution to the exact solution on a per cell basis to determine the distribution of the numerical error. The final activity comprises a comparison to continuous-energy Monte Carlo solutions for zero-power critical configuration measurements at Idaho National Laboratory’s Advanced Test Reactor (ATR). Results of this comparison will allow the investigators to distinguish between modeling errors and the above-listed discretization errors introduced by the deterministic method, and to separate the sources of uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on FY 2020 creep, fatigue and creep fatigue testing of Alloy 709 base metal at ORNL

The testing activities and research in support of ASME Code qualification of Alloy 709, an advanced austenitic steel, are being carried out at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory, and Idaho National Laboratory. This report summarizes the status and results of FY 2020 planned testing at ORNL. Uniaxial tensile tests on the electroslag remelt (ESR) solution-annealed plate (heat number 58776-3RBC) with additional heat treatment were performed for the baseline mechanical properties evaluation for ASME code qualification of Alloy 709. The tensile properties were found to meet ASME SA-213 specifications and were comparable to the Nippon Steel NF709 data generated for an ASME Section I Code Case for seamless tubing. ORNL was tasked to carry out a subset of the Code Case testing for creep rupture. Creep rupture data from 18 tests were generated on a solution-annealed ESR plate with a solution annealing temperature of 1100°C. There are total of 19 intermediate and long-term creep rupture tests of Alloy 709 ongoing at ORNL. A preliminary fatigue design curve at 760°C was developed for Alloy 709, and the results show that the fatigue design curve of Alloy 709 is comparable to that of Alloy 800H at 760°C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

COMPARISON OF RESPONSE OF 9977 TEST PACKAGES TO ANALYTICAL RESULTS

Each of the hypothetical accident test cases for the 9977 prototypes was included in the battery of finite element structural analyses performed for the package. Comparison of the experimental and analytical results provides a means of confirming that the analytical model correctly represents the physical behavior of the package. The ability of the analytical model to correctly predict the performance of the foam overpack material for the crush test is of particular interest. The dissipation of energy in the crushing process determines the deceleration of the package upon impact and the duration of the impact. In addition, if the analytical model correctly models the foam behavior, the predicted deformation of the package will match that measured on the test articles. This study compares the deformations of the test packages with the analytical predictions. In addition, the impact acceleration and impact duration for the test articles are compared with those predicted by the analyses.

42 ENGINEERING↗

Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix at multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗